Abstract:
:The potential of using the phase derivative (PD) for echographic imaging was investigated. The PD data were calculated by four methods: zero crossing (ZCS) with squelch addition, analytic signal either with squelch addition (ASS) or with employment of a Wiener kernel (ASW), and unwrapped phase (UWP). The large peaks which occur in an unprocessed PD signal were "stabilized" by some kind of smoothing algorithm. The effects of the amplitude of the squelch signal and of the degree of smoothing were systematically investigated for experimental and simulated 1-D and 2-D rf echograms. The optimal pictures obtained for all four PD estimation methods were compared to the amplitude modulated (AM) image obtained from the same rf data. It is concluded that three different PD images can be derived: AM dominated (ZCS, ASS), mixed AM-PD (ASW) and pure PD (UWP) images. Some preliminary conclusions regarding the potential of PD imaging for medical diagnostics were drawn. These conclusions were based on quantitative 1st order statistics and on a qualitative assessment of 2nd order statistics of the PD image texture.
journal_name
Ultrason Imagingjournal_title
Ultrasonic imagingauthors
Romijn RL,Oosterveld BJ,Thijssen JMdoi
10.1177/016173468700900301subject
Has Abstractpub_date
1987-07-01 00:00:00pages
147-61issue
3eissn
0161-7346issn
1096-0910journal_volume
9pub_type
杂志文章abstract::Ultrasonic waveform data from a tissue-mimicking phantom containing low contrast targets was digitized, stored and processed prior to creating and displaying ultrasonic images. Speckle reduction was performed by digital filtering of the waveform data with appropriately spaced and weighted digital filters, prior to bot...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173468700900202
更新日期:1987-04-01 00:00:00
abstract::The propagation of pressure pulses of arbitrary time form in inhomogeneous attenuating media with characteristics similar to real biological tissues is considered. A mathematical model using the quasi-optical approximation is developed to solve the wave equation. Such a model proves to be convenient for computer reali...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173469301500106
更新日期:1993-01-01 00:00:00
abstract::Conventional ultrasonic B-mode images qualitatively describe tissue structures but are unsuitable for quantitative analyses of scatterer properties. We have recently developed an ultrasonic parametric imaging technique based on the Nakagami statistical distribution that is able to quantify scatterer concentrations. Th...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173460803000202
更新日期:2008-04-01 00:00:00
abstract::Our group has proposed the concept of subharmonic aided pressure estimation (SHAPE) utilizing microbubble-based ultrasound contrast agent signals for the noninvasive estimation of hydrostatic blood pressures. An experimental system for in vitro SHAPE was constructed based on two single-element transducers assembled co...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173461103300301
更新日期:2011-07-01 00:00:00
abstract::For a class of scattering objects the mean separation between the scatterers is determined. Over a range of frequencies, ultrasonic back-scattered pressure signals are recorded. It is suggested to derive the mean spacing of an unknown scattering object by employing Fourier analysis and comparing the signal with signal...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173468300500405
更新日期:1983-10-01 00:00:00
abstract::The aim of this study was to assess whether acoustic structure quantification (ASQ) can differentiate normal from pathological thyroid parenchyma in patients with diffuse autoimmune thyroid disease (AITD). We evaluated 83 subjects (72 [87%] women and 11 [13%] men) aged 19 to 94 years with a mean age of 53 years. We pe...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/0161734615580766
更新日期:2016-03-01 00:00:00
abstract::The microbubble contrast agent destruction/replenishment technique has been widely applied to ultrasound-based blood flow estimation. The rate of increase of the time-intensity curve (TIC) due to microbubbles flowing into the region of interest as measured from B-mode images closely reflects the flow velocity. In this...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173460803000301
更新日期:2008-07-01 00:00:00
abstract::A Fourier transform (FT)-based technique for forming parallel receive beams has been previously employed to increase the imaging frame rate in ultrasonic imaging. However, the image quality in FT-based parallel reconstruction is degraded because differences in range focusing delays are ignored and a wide transmit beam...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173460302500201
更新日期:2003-04-01 00:00:00
abstract::Coherent speckle is a source of image noise in ultrasonic B-mode imaging. The use of multiple imaging frequencies has been suggested as a technique for speckle contrast reduction. This technique involves the averaging of images whose speckle patterns have been modified by a change in the spectrum of the transmitted or...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173468600800301
更新日期:1986-07-01 00:00:00
abstract::Acoustic form factors have been used to model the frequency dependence of acoustic scattering in phantoms and tissues. This work demonstrates that a broad range of scatterer sizes, individually well represented by Faran theory or a Gaussian form factor, is not accurately described by a single effective scatterer from ...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/0161734614534399
更新日期:2015-01-01 00:00:00
abstract::In this paper, quantitative tomographic reconstructions of biological tissue are presented. First, the experimental setup and a hybrid filtered backpropagation (FBP) technique are briefly described. Using this technique, which includes exact backpropagation of data prior to reconstruction by means of the classical FBP...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173469401600102
更新日期:1994-01-01 00:00:00
abstract::It may be possible to diagnose and monitor scarring, inflammation and edema in transplant kidney using reconstructive ultrasound elasticity imaging. Kidney elasticity is expected to change dramatically with scar, and to a lesser degree, with acute inflammation and edema. The hypothesis that changes in kidney elasticit...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173460002200303
更新日期:2000-07-01 00:00:00
abstract::Sidelobe contribution from off-axis targets degrades image quality in a coherent array imaging system. In ultrasound imaging, focusing errors resulting from sound-velocity inhomogeneities in human tissue--also known as phase aberrations reduce the coherence of the received signals and elevate the sidelobe level. This ...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173460502700205
更新日期:2005-04-01 00:00:00
abstract::Regional anesthesia is preferred over general anesthesia for many surgical procedures; however, challenges associated with poor image guidance limit its widespread acceptance as a viable alternative. In B-mode ultrasound images, the current standard for guidance, nerves can be difficult to visualize due to their simil...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173460903100303
更新日期:2009-07-01 00:00:00
abstract::An adaptive scan sequence is proposed for real-time ultrasound three-dimensional (3-D) imaging. Generally, the refresh rate of 3-D imaging is limited by the view window, resolution and sound speed in the human body. If the object is transformed or moved during the data set acquisition, the 3-D image will be distorted....
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173460302500401
更新日期:2003-10-01 00:00:00
abstract::Peripheral artery disease is often asymptomatic, and various imaging and nonimaging techniques have been used for assessment and monitoring treatments. This study is designed to demonstrate the ability of photoacoustic imaging to noninvasively determine changes in tissue oxygenation that occur in mice's hind limb skel...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/0161734619862287
更新日期:2019-09-01 00:00:00
abstract::The theory of diffraction tomography for two-dimensional objects within the Born approximation is presented for cases where the scattered field is measured over arbitrarily shaped boundaries surrounding the object. Reconstruction algorithms are presented for both plane wave (parallel beam) and cylindrical wave (fan be...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173468400600207
更新日期:1984-04-01 00:00:00
abstract::Anova and "dummy variables" least squares regression methods are used to investigate the dependence of ultrasound propagation velocity on the presence or absence of fat and on the rank ordered level of cirrhosis in fixed human liver. Cirrhosis is found to affect velocity in a nonlinear fashion, while fat depresses the...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173468300500306
更新日期:1983-07-01 00:00:00
abstract::Attenuation measurements of various tissue mimicking phantoms and three different groups of patients were obtained using a modified commercial sector scanner. Estimates of attenuation were made using the spectral shift method with mean frequencies at different depths of a region of interest being obtained by both zero...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173468400600402
更新日期:1984-10-01 00:00:00
abstract::A new online signal processing technique is described to reduce speckle noise in ultrasound images. In the imaging system, a focused piston transducer is divided into thirty-two sectors. In the receive mode, parallel signal processing arranges the sectors into eight maltese crosses. The rf signals of the perpendicular...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173468801000301
更新日期:1988-07-01 00:00:00
abstract::Statistical pattern recognition procedures allow a quantitative description of ultrasound-B-scan image texture. According to well-established animal models, different types of fatty liver disease were induced in female Wistar rats. For the correlation of the computerized ultrasound image with its underlying histology ...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173469001200302
更新日期:1990-07-01 00:00:00
abstract::Hall effect imaging is an ultrasound-based method of mapping spatial variations in the dielectric constants of an acoustically-uniform sample. This paper presents three-dimensional Hall effect images of phantoms obtained by scanning a single transducer across a two-dimensional grid, effectively simulating two-dimensio...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173469902100303
更新日期:1999-07-01 00:00:00
abstract::The amplitude and frequency contents of a received ultrasound pulse depends on the spatial pressure amplitude distribution of the sound field, as produced by the transducer in the medium, and on the position and orientation of the reflecting surface in this field. Often, the geometry of the reflecting surface and the ...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173469001200405
更新日期:1990-10-01 00:00:00
abstract::Tissues exhibiting quasi-periodic structures can be modeled as a collection of diffuse scatterers and coherent scatterers. The mean scatterer spacing (MSS) of coherent and quasi-periodic components is directly related to tissue microstructure and has become an important quantitative ultrasound (QUS) parameter in the c...
journal_title:Ultrasonic imaging
pub_type: 杂志文章,评审
doi:10.1177/0161734617692018
更新日期:2017-09-01 00:00:00
abstract::Behavior and limitations of the sinc basis method have been discovered during simulation studies. An iterative row-action method (ART) is compared with a full-matrix, least-squares solution (QR decomposition) and the problem of multiple solutions is discussed. Knowledge of the spatial distribution of scattered field e...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173468901100103
更新日期:1989-01-01 00:00:00
abstract::This paper describes a method for overcoming motion artifacts in synthetic aperture imaging. The method is based on a computer simulation study on the influence of target motion on synthetic aperture techniques. A region-based motion compensation approach is used in which only the axial motion is estimated and compens...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173460202400202
更新日期:2002-04-01 00:00:00
abstract::This paper presents a new beamforming technique, in which ultrasound waves are focused at the display pixels on the Cartesian coordinates, rather than sampling points located on the uniformly-separated scanlines on either the polar or Cartesian coordinates. Consequently, this method does not require a digital scan con...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173460102300101
更新日期:2001-01-01 00:00:00
abstract::Mean frequency estimators as used in pulsed Doppler ultrasound equipment should provide an accurate (quality) and consistent (robustness) estimate over a wide range of signal conditions. In a simplified signal model, the main parameters to consider are the noise level, mean frequency, bandwidth and power of both the D...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173469201400404
更新日期:1992-10-01 00:00:00
abstract::Global and local attenuation coefficient estimations were performed in a phantom using a pulse echo method based on the rate of decay of zero crossing density. Focussed and unfocussed 3.5 MHz transducers were used. It was found that good global estimates could be made with either transducer over a 2:1 range of attenua...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173468500700202
更新日期:1985-04-01 00:00:00
abstract::When modeling or simulating an ultrasonic pulse-echo system it is necessary to know the transducer waveforms that are the input to the system. In general, accurate transducer modeling is complex and waveform calculation is computationally intensive. Because of this, investigators often assume these waveforms to be sim...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173468700900405
更新日期:1987-10-01 00:00:00