Abstract:
:Muscle fatigue often occurs over a long period of exercise, and it can increase the risk of muscle injury. Evaluating the state of muscle fatigue can avoid unnecessary overtraining and injury of the muscle. Ultrasound imaging can non-invasively visualize muscle tissue in real-time. Image entropy is commonly used to characterize the texture of an image. In this study, we evaluated changes in the ultrasound image entropy (USIE) during the fatigue process. Twelve volunteers performed static sustained contractions of biceps brachii at four different intensities (20%, 30%, 40%, and 50% of maximal voluntary contraction torque). The ultrasound images and surface electromyography (sEMG) signals were acquired during exercise to fatigue. We found that (1) the root-mean-square of the sEMG signal increased, the USIE decreased significantly with time during the sustained contractions; (2) the maximum endurance time (MET) and the decline percentage of USIE were significantly different (p < .05) among the four contraction intensities; (3) the decline slope of USIE of the same volunteer was basically the same at different contraction intensities. The USIE could be a new method for the evaluation of skeletal muscle fatigue state.
journal_name
Ultrason Imagingjournal_title
Ultrasonic imagingauthors
Li P,Yang X,Yin G,Guo Jdoi
10.1177/0161734620952683subject
Has Abstractpub_date
2020-11-01 00:00:00pages
235-244issue
6eissn
0161-7346issn
1096-0910journal_volume
42pub_type
杂志文章abstract::This study shows that the amplitude information of ultrasound echoes is carried mainly by the envelope peaks (EPs). It is first shown that the EPs in an A-line represent the maximum number of independent amplitude data. It is then demonstrated that the entire envelope could be approximately reconstructed from the EPs....
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173468801000403
更新日期:1988-10-01 00:00:00
abstract::Transesophageal echocardiography (TEE) is an essential diagnostic tool in patients with poor transthoracic echocardiographic windows or when detailed imaging of structures distant from the chest wall is necessary. A real-time 3D TEE probe has been fabricated in our laboratory in order to increase the amount of informa...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173460402600402
更新日期:2004-10-01 00:00:00
abstract::Two-dimensional echocardiography (2-D echo) imaging is a more attractive clinical tool than other modalities that either involve radiation exposure or are too slow to image heart motion in real-time. Computer-aided analysis of left ventricular(LV) wall motion provides quantitative parameters for diagnosis. This study ...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173469701900204
更新日期:1997-04-01 00:00:00
abstract::An algorithm for deconvolution of medical ultrasound images is presented. The procedure involves estimation of the basic one-dimensional ultrasound pulse, determining the ratio of the covariance of the noise to the covariance of the reflection signal, and finally deconvolution of the rf signal from the transducer. Usi...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173469301500204
更新日期:1993-04-01 00:00:00
abstract::This paper presents a new beamforming technique, in which ultrasound waves are focused at the display pixels on the Cartesian coordinates, rather than sampling points located on the uniformly-separated scanlines on either the polar or Cartesian coordinates. Consequently, this method does not require a digital scan con...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173460102300101
更新日期:2001-01-01 00:00:00
abstract::Coherent speckle is a source of image noise in ultrasonic B-mode imaging. The use of multiple imaging frequencies has been suggested as a technique for speckle contrast reduction. This technique involves the averaging of images whose speckle patterns have been modified by a change in the spectrum of the transmitted or...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173468600800301
更新日期:1986-07-01 00:00:00
abstract::Hall effect imaging is an ultrasound-based method of mapping spatial variations in the dielectric constants of an acoustically-uniform sample. This paper presents three-dimensional Hall effect images of phantoms obtained by scanning a single transducer across a two-dimensional grid, effectively simulating two-dimensio...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173469902100303
更新日期:1999-07-01 00:00:00
abstract::Optimal transmit phasing has been proposed to increase contrast-to-tissue ratio (CTR) by relatively phasing the tissue and leakage harmonic components to cancel each other out for tissue-background suppression in harmonic imaging. Since most clinical systems are only equipped with a bipolar square-wave pulser, effecti...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173461003200103
更新日期:2010-01-01 00:00:00
abstract::Global and local attenuation coefficient estimations were performed in a phantom using a pulse echo method based on the rate of decay of zero crossing density. Focussed and unfocussed 3.5 MHz transducers were used. It was found that good global estimates could be made with either transducer over a 2:1 range of attenua...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173468500700202
更新日期:1985-04-01 00:00:00
abstract::Acoustic form factors have been used to model the frequency dependence of acoustic scattering in phantoms and tissues. This work demonstrates that a broad range of scatterer sizes, individually well represented by Faran theory or a Gaussian form factor, is not accurately described by a single effective scatterer from ...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/0161734614534399
更新日期:2015-01-01 00:00:00
abstract::Generation of the second harmonic signal was studied for finite amplitude distortion based harmonic imaging. Acoustic field amplitudes along the range axis of a fixed focus transducer were measured using a PVDF needle hydrophone. Results indicated that on-axis amplitudes strongly depended on the f-number at both the f...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173469902100401
更新日期:1999-10-01 00:00:00
abstract::Computer texture analysis methods use texture features that are traditionally chosen from a large set of fixed features known in literature. These fixed features are often not specifically designed to the problem at hand, and as a result they may have low discriminative power, and/or may be correlated. Increasing the ...
journal_title:Ultrasonic imaging
pub_type: 杂志文章,评审
doi:10.1177/016173469802000204
更新日期:1998-04-01 00:00:00
abstract::Acoustic Radiation Force Impulse (ARFI) imaging is a method for characterizing local variations in tissue mechanical properties. In this method, a single ultrasonic transducer array is used to both apply temporally short localized radiation forces within tissue and to track the resulting displacements through time. In...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173460202400301
更新日期:2002-07-01 00:00:00
abstract::A narrow-band ultrasonic shear-wave imaging technique for estimating phase speed was applied to fresh and thermally damaged porcine liver in vitro. Two constitutive models were applied to the measurements to represent rheological behavior of the tissue and estimate the complex shear modulus at frequencies between 50 a...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173461003200405
更新日期:2010-10-01 00:00:00
abstract::In recent years, adaptive minimum-variance (MV) beamforming has been successfully applied to medical ultrasound imaging, resulting in simultaneous improvement in imaging resolution and contrast. MV has high resolution and hence can provide accurate estimates of the target locations. However, the MV amplitude estimates...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/0161734615600167
更新日期:2016-07-01 00:00:00
abstract::Previously reported data on the temperature dependence of propagation speed in tissues generally span only temperature ranges up to 60 degrees C. However, with the emerging use of thermal ablative therapies, information on variation in this parameter over higher temperature ranges is needed. Measurements of the ultras...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173460202400404
更新日期:2002-10-01 00:00:00
abstract::Ultrasonic waveform data from a tissue-mimicking phantom containing low contrast targets was digitized, stored and processed prior to creating and displaying ultrasonic images. Speckle reduction was performed by digital filtering of the waveform data with appropriately spaced and weighted digital filters, prior to bot...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173468700900202
更新日期:1987-04-01 00:00:00
abstract::This paper describes a method for overcoming motion artifacts in synthetic aperture imaging. The method is based on a computer simulation study on the influence of target motion on synthetic aperture techniques. A region-based motion compensation approach is used in which only the axial motion is estimated and compens...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173460202400202
更新日期:2002-04-01 00:00:00
abstract::Mean frequency estimators as used in pulsed Doppler ultrasound equipment should provide an accurate (quality) and consistent (robustness) estimate over a wide range of signal conditions. In a simplified signal model, the main parameters to consider are the noise level, mean frequency, bandwidth and power of both the D...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173469201400404
更新日期:1992-10-01 00:00:00
abstract::Most methods for in vivo quantitation of ultrasound attenuation and backscatter are not available clinically because they rely upon acquiring and analyzing radio frequency (rf) echo signals. This paper describes a technique to estimate ultrasound attenuation and backscatter from B-mode image data. The video signal ana...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173469701900305
更新日期:1997-07-01 00:00:00
abstract::Tracking large deformations in tissue using ultrasound can enable the reconstruction of nonlinear elastic parameters, but poses a challenge to displacement estimation algorithms. Such large deformations have to be broken up into steps, each of which contributes an estimation error to the final accumulated displacement...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/0161734613479246
更新日期:2013-04-01 00:00:00
abstract::To perform computer-aided diagnosis of the thyroid nodules on ultrasound images, the location and boundary of nodules should be clearly defined. However, the identification of thyroid nodule boundary is a difficult issue due to the biological characteristics of the nodules, the physics and quality of ultrasound imagin...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/0161734619839648
更新日期:2019-07-01 00:00:00
abstract::It may be possible to diagnose and monitor scarring, inflammation and edema in transplant kidney using reconstructive ultrasound elasticity imaging. Kidney elasticity is expected to change dramatically with scar, and to a lesser degree, with acute inflammation and edema. The hypothesis that changes in kidney elasticit...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173460002200303
更新日期:2000-07-01 00:00:00
abstract::Acoustic radiation force impulse (ARFI) Surveillance of Subcutaneous Hemorrhage (ASSH) has been previously demonstrated to differentiate bleeding phenotype and responses to therapy in dogs and humans, but to date, the method has lacked experimental validation. This work explores experimental validation of ASSH in a po...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/0161734615617940
更新日期:2016-09-01 00:00:00
abstract::Acoustic radiation force (ARF) has become a common excitation mechanism in elasticity imaging. The high acoustic intensities and subsequent generation of harmonics, however, hamper the effectiveness of using conventional radiofrequency (rf) tracking to investigate the dynamics of tissues and catheter-based transducers...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:
更新日期:2009-01-01 00:00:00
abstract::The microbubble contrast agent destruction/replenishment technique has been widely applied to ultrasound-based blood flow estimation. The rate of increase of the time-intensity curve (TIC) due to microbubbles flowing into the region of interest as measured from B-mode images closely reflects the flow velocity. In this...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173460803000301
更新日期:2008-07-01 00:00:00
abstract::Behavior and limitations of the sinc basis method have been discovered during simulation studies. An iterative row-action method (ART) is compared with a full-matrix, least-squares solution (QR decomposition) and the problem of multiple solutions is discussed. Knowledge of the spatial distribution of scattered field e...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173468901100103
更新日期:1989-01-01 00:00:00
abstract::The amplitude and frequency contents of a received ultrasound pulse depends on the spatial pressure amplitude distribution of the sound field, as produced by the transducer in the medium, and on the position and orientation of the reflecting surface in this field. Often, the geometry of the reflecting surface and the ...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173469001200405
更新日期:1990-10-01 00:00:00
abstract::An autoregressive (AR) spectral estimation method was considered for the purpose of estimating scatterer size images. The variance and bias of the resulting estimates were compared with those using classical FFT periodograms for a range of input signal-to-noise ratios and echo-signal durations corresponding to various...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173469601800102
更新日期:1996-01-01 00:00:00
abstract::In medical ultrasound imaging, two-dimensional (2-D) array transducers are desirable to implement dynamic focusing and phase aberration correction in two dimensions as well as volumetric imaging. Unfortunately, the small size of a 2-D array element results in a small clamped capacitance and a large electrical impedanc...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173469501700202
更新日期:1995-04-01 00:00:00