Attenuation and backscatter estimation using video signal analysis applied to B-mode images.

Abstract:

:Most methods for in vivo quantitation of ultrasound attenuation and backscatter are not available clinically because they rely upon acquiring and analyzing radio frequency (rf) echo signals. This paper describes a technique to estimate ultrasound attenuation and backscatter from B-mode image data. The video signal analysis (VSA) technique utilizes images of a reference phantom, taken using the same instrument settings used to record images from the patient or sample, to account for effects of the transducer beam, system gain and signal processing on image data. A 'gray-scale look-up table' is derived to convert image pixel value data within a region of interest to echo signal amplitudes relative to echo signals from the same depth in the reference phantom. These relative echo levels enable estimates of attenuation and backscatter in the region of interest. VSA was used to quantify acoustic properties of test phantoms using 3 different clinical scanners and various transducers. The level of agreement between results obtained with different ultrasound imaging systems was very good. VSA attenuation and backscatter levels also compare favorably with attenuation coefficients and backscatter coefficients obtained using rf analysis.

journal_name

Ultrason Imaging

journal_title

Ultrasonic imaging

authors

Knipp BS,Zagzebski JA,Wilson TA,Dong F,Madsen EL

doi

10.1177/016173469701900305

subject

Has Abstract

pub_date

1997-07-01 00:00:00

pages

221-33

issue

3

eissn

0161-7346

issn

1096-0910

journal_volume

19

pub_type

杂志文章
  • A comparison method for mean frequency estimators for Doppler ultrasound.

    abstract::Mean frequency estimators as used in pulsed Doppler ultrasound equipment should provide an accurate (quality) and consistent (robustness) estimate over a wide range of signal conditions. In a simplified signal model, the main parameters to consider are the noise level, mean frequency, bandwidth and power of both the D...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173469201400404

    authors: Brands PJ,Hoeks AP

    更新日期:1992-10-01 00:00:00

  • Rotation Elastogram Estimation Using Synthetic Transmit-aperture Technique: A Feasibility Study.

    abstract::It is well-documented in literature that benign breast lesions, such as fibroadenomas, are loosely bonded to their surrounding tissue and tend to slip under a small quasi-static compression, whereas malignant lesions being firmly bonded to their surrounding tissue do not slip. Recent developments in quasi-static ultra...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/0161734616686746

    authors: B L,Chintada BR,Thittai AK

    更新日期:2017-05-01 00:00:00

  • Digital simulation of pulsed ultrasonic waveforms.

    abstract::When modeling or simulating an ultrasonic pulse-echo system it is necessary to know the transducer waveforms that are the input to the system. In general, accurate transducer modeling is complex and waveform calculation is computationally intensive. Because of this, investigators often assume these waveforms to be sim...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173468700900405

    authors: Barber FE,Goodsitt MM

    更新日期:1987-10-01 00:00:00

  • Statistical relationship between ultrasound echo envelope and envelope peak.

    abstract::This study shows that the amplitude information of ultrasound echoes is carried mainly by the envelope peaks (EPs). It is first shown that the EPs in an A-line represent the maximum number of independent amplitude data. It is then demonstrated that the entire envelope could be approximately reconstructed from the EPs....

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173468801000403

    authors: He P

    更新日期:1988-10-01 00:00:00

  • Reduction of the clutter component in Doppler ultrasound signals based on singular value decomposition: a simulation study.

    abstract::In pulsed Doppler ultrasound systems, the ultrasound radiofrequency (RF) signals received can be employed to estimate noninvasively the time-dependent blood velocity distribution within and artery. The RF signals are composed of signals originating from clutter (e.g., vessel walls) and scatterers (e.g., red blood cell...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173469701900101

    authors: Ledoux LA,Brands PJ,Hoeks AP

    更新日期:1997-01-01 00:00:00

  • Combining the APES and Minimum-variance Beamformers for Adaptive Ultrasound Imaging.

    abstract::In recent years, adaptive minimum-variance (MV) beamforming has been successfully applied to medical ultrasound imaging, resulting in simultaneous improvement in imaging resolution and contrast. MV has high resolution and hence can provide accurate estimates of the target locations. However, the MV amplitude estimates...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/0161734615600167

    authors: Mohammadzadeh Asl B

    更新日期:2016-07-01 00:00:00

  • Classification of scattering objects by regular arrays of scatterers using Fourier analysis.

    abstract::For a class of scattering objects the mean separation between the scatterers is determined. Over a range of frequencies, ultrasonic back-scattered pressure signals are recorded. It is suggested to derive the mean spacing of an unknown scattering object by employing Fourier analysis and comparing the signal with signal...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173468300500405

    authors: Koch I

    更新日期:1983-10-01 00:00:00

  • A Review of Ultrasound Tissue Characterization with Mean Scatterer Spacing.

    abstract::Tissues exhibiting quasi-periodic structures can be modeled as a collection of diffuse scatterers and coherent scatterers. The mean scatterer spacing (MSS) of coherent and quasi-periodic components is directly related to tissue microstructure and has become an important quantitative ultrasound (QUS) parameter in the c...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章,评审

    doi:10.1177/0161734617692018

    authors: Zhou Z,Wu W,Wu S,Jia K,Tsui PH

    更新日期:2017-09-01 00:00:00

  • Quantitative assessment of in vivo backscatter enhancement from gelatin microspheres.

    abstract::Experimental work using a quantitative C-scan technique to measure in situ enhancement of hepatic backscatter resulting from the administration of gelatin microspheres to dogs is reported. We have found that reproducible enhancement of hepatic backscatter on the order of 2 dB followed the peripheral administration of ...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173468500700402

    authors: Ophir J,Gobuty A,Maklad N,Tyler T,Jaeger P,McWhirt R

    更新日期:1985-10-01 00:00:00

  • Deconvolution of in-vivo ultrasound B-mode images.

    abstract::An algorithm for deconvolution of medical ultrasound images is presented. The procedure involves estimation of the basic one-dimensional ultrasound pulse, determining the ratio of the covariance of the noise to the covariance of the reflection signal, and finally deconvolution of the rf signal from the transducer. Usi...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173469301500204

    authors: Jensen JA,Mathorne J,Gravesen T,Stage B

    更新日期:1993-04-01 00:00:00

  • Neural-network-based Motion Tracking for Breast Ultrasound Strain Elastography: An Initial Assessment of Performance and Feasibility.

    abstract::Accurate tracking of tissue motion is critically important for several ultrasound elastography methods. In this study, we investigate the feasibility of using three published convolution neural network (CNN) models built for optical flow (hereafter referred to as CNN-based tracking) by the computer vision community fo...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/0161734620902527

    authors: Peng B,Xian Y,Zhang Q,Jiang J

    更新日期:2020-03-01 00:00:00

  • Transducer characterization from pressure amplitude distribution measurements using a Kalman filter as parameter estimation algorithm.

    abstract::The amplitude and frequency contents of a received ultrasound pulse depends on the spatial pressure amplitude distribution of the sound field, as produced by the transducer in the medium, and on the position and orientation of the reflecting surface in this field. Often, the geometry of the reflecting surface and the ...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173469001200405

    authors: Linssen FM,Hoeks AP

    更新日期:1990-10-01 00:00:00

  • Adaptive imaging using an optimal receive aperture size.

    abstract::Sidelobe contribution from off-axis targets degrades image quality in a coherent array imaging system. In ultrasound imaging, focusing errors resulting from sound-velocity inhomogeneities in human tissue--also known as phase aberrations reduce the coherence of the received signals and elevate the sidelobe level. This ...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173460502700205

    authors: Li ML,Huang SW,Ustüner K,Li PC

    更新日期:2005-04-01 00:00:00

  • Shielding of piezoelectric ultrasonic probes in Hall effect imaging.

    abstract::This paper addresses significant sources of electromagnetic noise in Hall effect imaging. Hall effect imaging employs large electrical pulses for signal generation and high sensitivity ultrasonic probes for signal reception. Coherent noise arises through various coupling mechanisms between the excitation pulse and the...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173469802000305

    authors: Wen H,Bennett E,Wiesler DG

    更新日期:1998-07-01 00:00:00

  • Computerized ultrasound B-scan texture analysis of experimental fatty liver disease: influence of total lipid content and fat deposit distribution.

    abstract::Statistical pattern recognition procedures allow a quantitative description of ultrasound-B-scan image texture. According to well-established animal models, different types of fatty liver disease were induced in female Wistar rats. For the correlation of the computerized ultrasound image with its underlying histology ...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173469001200302

    authors: Layer G,Zuna I,Lorenz A,Zerban H,Haberkorn U,Bannasch P,van Kaick G,Räth U

    更新日期:1990-07-01 00:00:00

  • Ultrasound velocity in fixed human liver: empirical anova and regression modelling on histologically assessed abnormalities.

    abstract::Anova and "dummy variables" least squares regression methods are used to investigate the dependence of ultrasound propagation velocity on the presence or absence of fat and on the rank ordered level of cirrhosis in fixed human liver. Cirrhosis is found to affect velocity in a nonlinear fashion, while fat depresses the...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173468300500306

    authors: Zimmermann KP,Smith JC

    更新日期:1983-07-01 00:00:00

  • Ultrasound attenuation measurements of the liver in vivo using a commercial sector scanner.

    abstract::Attenuation measurements of various tissue mimicking phantoms and three different groups of patients were obtained using a modified commercial sector scanner. Estimates of attenuation were made using the spectral shift method with mean frequencies at different depths of a region of interest being obtained by both zero...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173468400600402

    authors: Garra BS,Shawker TH,Nassi M,Russell MA

    更新日期:1984-10-01 00:00:00

  • Real-time 3D transesophageal echocardiography.

    abstract::Transesophageal echocardiography (TEE) is an essential diagnostic tool in patients with poor transthoracic echocardiographic windows or when detailed imaging of structures distant from the chest wall is necessary. A real-time 3D TEE probe has been fabricated in our laboratory in order to increase the amount of informa...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173460402600402

    authors: Pua EC,Idriss SF,Wolf PD,Smith SW

    更新日期:2004-10-01 00:00:00

  • Ultrasonic backscatter and attenuation (11-27 MHz) variation with collagen fiber distribution in ex vivo human dermis.

    abstract::This ex vivo study explores the relationship of ultrasonic attenuation and backscatter to dermal microarchitecture by comparing ultrasonic measurements of these parameters (11-27 MHz) to a microscopic analysis of three parameters describing the collagen distribution (mean thickness and spacing of collagen bundles alon...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173460602800103

    authors: Bridal SL,Fournier C,Coron A,Leguerney I,Laugier P

    更新日期:2006-01-01 00:00:00

  • The Maltese cross processor: speckle reduction for circular transducers.

    abstract::A new online signal processing technique is described to reduce speckle noise in ultrasound images. In the imaging system, a focused piston transducer is divided into thirty-two sectors. In the receive mode, parallel signal processing arranges the sectors into eight maltese crosses. The rf signals of the perpendicular...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173468801000301

    authors: Smith SW,von Ramm OT

    更新日期:1988-07-01 00:00:00

  • Experimental Validation of ARFI Surveillance of Subcutaneous Hemorrhage (ASSH) Using Calibrated Infusions in a Tissue-Mimicking Model and Dogs.

    abstract::Acoustic radiation force impulse (ARFI) Surveillance of Subcutaneous Hemorrhage (ASSH) has been previously demonstrated to differentiate bleeding phenotype and responses to therapy in dogs and humans, but to date, the method has lacked experimental validation. This work explores experimental validation of ASSH in a po...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/0161734615617940

    authors: Geist RE,DuBois CH,Nichols TC,Caughey MC,Merricks EP,Raymer R,Gallippi CM

    更新日期:2016-09-01 00:00:00

  • Subharmonic contrast microbubble signals for noninvasive pressure estimation under static and dynamic flow conditions.

    abstract::Our group has proposed the concept of subharmonic aided pressure estimation (SHAPE) utilizing microbubble-based ultrasound contrast agent signals for the noninvasive estimation of hydrostatic blood pressures. An experimental system for in vitro SHAPE was constructed based on two single-element transducers assembled co...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173461103300301

    authors: Halldorsdottir VG,Dave JK,Leodore LM,Eisenbrey JR,Park S,Hall AL,Thomenius K,Forsberg F

    更新日期:2011-07-01 00:00:00

  • Improved Fourier-transform-based parallel receive beam formation.

    abstract::A Fourier transform (FT)-based technique for forming parallel receive beams has been previously employed to increase the imaging frame rate in ultrasonic imaging. However, the image quality in FT-based parallel reconstruction is degraded because differences in range focusing delays are ignored and a wide transmit beam...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173460302500201

    authors: Li ML,Li PC

    更新日期:2003-04-01 00:00:00

  • Observations of tissue response to acoustic radiation force: opportunities for imaging.

    abstract::Acoustic Radiation Force Impulse (ARFI) imaging is a method for characterizing local variations in tissue mechanical properties. In this method, a single ultrasonic transducer array is used to both apply temporally short localized radiation forces within tissue and to track the resulting displacements through time. In...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173460202400301

    authors: Nightingale K,Bentley R,Trahey G

    更新日期:2002-07-01 00:00:00

  • Volumetric Hall effect tomography--a feasibility study.

    abstract::Hall effect imaging is an ultrasound-based method of mapping spatial variations in the dielectric constants of an acoustically-uniform sample. This paper presents three-dimensional Hall effect images of phantoms obtained by scanning a single transducer across a two-dimensional grid, effectively simulating two-dimensio...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173469902100303

    authors: Wen H

    更新日期:1999-07-01 00:00:00

  • Variance and covariance of accumulated displacement estimates.

    abstract::Tracking large deformations in tissue using ultrasound can enable the reconstruction of nonlinear elastic parameters, but poses a challenge to displacement estimation algorithms. Such large deformations have to be broken up into steps, each of which contributes an estimation error to the final accumulated displacement...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/0161734613479246

    authors: Bayer M,Hall TJ

    更新日期:2013-04-01 00:00:00

  • Adaptive texture feature extraction with application to ultrasonic image analysis.

    abstract::Computer texture analysis methods use texture features that are traditionally chosen from a large set of fixed features known in literature. These fixed features are often not specifically designed to the problem at hand, and as a result they may have low discriminative power, and/or may be correlated. Increasing the ...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章,评审

    doi:10.1177/016173469802000204

    authors: Huisman HJ,Thijssen JM

    更新日期:1998-04-01 00:00:00

  • Breast tissue classification using diagnostic ultrasound and pattern recognition techniques: II. Experimental results.

    abstract::The methods of statistical pattern recognition have been applied to the problem of in vivo ultrasonic characterization of breast disease in humans. Backscattered A-mode signals obtained from a commercial pulse imaging system were used to generate a large set of potentially useful features. Using statistical tests, a s...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173468300500107

    authors: Finette S,Bleier AR,Swindell W,Haber K

    更新日期:1983-01-01 00:00:00

  • An efficient motion estimation and compensation method for ultrasound synthetic aperture imaging.

    abstract::This paper describes a method for overcoming motion artifacts in synthetic aperture imaging. The method is based on a computer simulation study on the influence of target motion on synthetic aperture techniques. A region-based motion compensation approach is used in which only the axial motion is estimated and compens...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173460202400202

    authors: Kim KS,Hwang JS,Jeong JS,Song TK

    更新日期:2002-04-01 00:00:00

  • Compressed Sensing for Elastography in Portable Ultrasound.

    abstract::Portable ultrasound is recently emerging as a new medical imaging modality featuring high portability, easy connectivity, and real-time on-site diagnostic ability. However, it does not yet provide ultrasound elastography function that enables the diagnosis of malignant lesions using elastic properties. This is mainly ...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/0161734617716938

    authors: Shin B,Jeon S,Ryu J,Kwon HJ

    更新日期:2017-11-01 00:00:00