Abstract:
:Most methods for in vivo quantitation of ultrasound attenuation and backscatter are not available clinically because they rely upon acquiring and analyzing radio frequency (rf) echo signals. This paper describes a technique to estimate ultrasound attenuation and backscatter from B-mode image data. The video signal analysis (VSA) technique utilizes images of a reference phantom, taken using the same instrument settings used to record images from the patient or sample, to account for effects of the transducer beam, system gain and signal processing on image data. A 'gray-scale look-up table' is derived to convert image pixel value data within a region of interest to echo signal amplitudes relative to echo signals from the same depth in the reference phantom. These relative echo levels enable estimates of attenuation and backscatter in the region of interest. VSA was used to quantify acoustic properties of test phantoms using 3 different clinical scanners and various transducers. The level of agreement between results obtained with different ultrasound imaging systems was very good. VSA attenuation and backscatter levels also compare favorably with attenuation coefficients and backscatter coefficients obtained using rf analysis.
journal_name
Ultrason Imagingjournal_title
Ultrasonic imagingauthors
Knipp BS,Zagzebski JA,Wilson TA,Dong F,Madsen ELdoi
10.1177/016173469701900305subject
Has Abstractpub_date
1997-07-01 00:00:00pages
221-33issue
3eissn
0161-7346issn
1096-0910journal_volume
19pub_type
杂志文章abstract::Mean frequency estimators as used in pulsed Doppler ultrasound equipment should provide an accurate (quality) and consistent (robustness) estimate over a wide range of signal conditions. In a simplified signal model, the main parameters to consider are the noise level, mean frequency, bandwidth and power of both the D...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173469201400404
更新日期:1992-10-01 00:00:00
abstract::It is well-documented in literature that benign breast lesions, such as fibroadenomas, are loosely bonded to their surrounding tissue and tend to slip under a small quasi-static compression, whereas malignant lesions being firmly bonded to their surrounding tissue do not slip. Recent developments in quasi-static ultra...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/0161734616686746
更新日期:2017-05-01 00:00:00
abstract::When modeling or simulating an ultrasonic pulse-echo system it is necessary to know the transducer waveforms that are the input to the system. In general, accurate transducer modeling is complex and waveform calculation is computationally intensive. Because of this, investigators often assume these waveforms to be sim...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173468700900405
更新日期:1987-10-01 00:00:00
abstract::This study shows that the amplitude information of ultrasound echoes is carried mainly by the envelope peaks (EPs). It is first shown that the EPs in an A-line represent the maximum number of independent amplitude data. It is then demonstrated that the entire envelope could be approximately reconstructed from the EPs....
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173468801000403
更新日期:1988-10-01 00:00:00
abstract::In pulsed Doppler ultrasound systems, the ultrasound radiofrequency (RF) signals received can be employed to estimate noninvasively the time-dependent blood velocity distribution within and artery. The RF signals are composed of signals originating from clutter (e.g., vessel walls) and scatterers (e.g., red blood cell...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173469701900101
更新日期:1997-01-01 00:00:00
abstract::In recent years, adaptive minimum-variance (MV) beamforming has been successfully applied to medical ultrasound imaging, resulting in simultaneous improvement in imaging resolution and contrast. MV has high resolution and hence can provide accurate estimates of the target locations. However, the MV amplitude estimates...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/0161734615600167
更新日期:2016-07-01 00:00:00
abstract::For a class of scattering objects the mean separation between the scatterers is determined. Over a range of frequencies, ultrasonic back-scattered pressure signals are recorded. It is suggested to derive the mean spacing of an unknown scattering object by employing Fourier analysis and comparing the signal with signal...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173468300500405
更新日期:1983-10-01 00:00:00
abstract::Tissues exhibiting quasi-periodic structures can be modeled as a collection of diffuse scatterers and coherent scatterers. The mean scatterer spacing (MSS) of coherent and quasi-periodic components is directly related to tissue microstructure and has become an important quantitative ultrasound (QUS) parameter in the c...
journal_title:Ultrasonic imaging
pub_type: 杂志文章,评审
doi:10.1177/0161734617692018
更新日期:2017-09-01 00:00:00
abstract::Experimental work using a quantitative C-scan technique to measure in situ enhancement of hepatic backscatter resulting from the administration of gelatin microspheres to dogs is reported. We have found that reproducible enhancement of hepatic backscatter on the order of 2 dB followed the peripheral administration of ...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173468500700402
更新日期:1985-10-01 00:00:00
abstract::An algorithm for deconvolution of medical ultrasound images is presented. The procedure involves estimation of the basic one-dimensional ultrasound pulse, determining the ratio of the covariance of the noise to the covariance of the reflection signal, and finally deconvolution of the rf signal from the transducer. Usi...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173469301500204
更新日期:1993-04-01 00:00:00
abstract::Accurate tracking of tissue motion is critically important for several ultrasound elastography methods. In this study, we investigate the feasibility of using three published convolution neural network (CNN) models built for optical flow (hereafter referred to as CNN-based tracking) by the computer vision community fo...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/0161734620902527
更新日期:2020-03-01 00:00:00
abstract::The amplitude and frequency contents of a received ultrasound pulse depends on the spatial pressure amplitude distribution of the sound field, as produced by the transducer in the medium, and on the position and orientation of the reflecting surface in this field. Often, the geometry of the reflecting surface and the ...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173469001200405
更新日期:1990-10-01 00:00:00
abstract::Sidelobe contribution from off-axis targets degrades image quality in a coherent array imaging system. In ultrasound imaging, focusing errors resulting from sound-velocity inhomogeneities in human tissue--also known as phase aberrations reduce the coherence of the received signals and elevate the sidelobe level. This ...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173460502700205
更新日期:2005-04-01 00:00:00
abstract::This paper addresses significant sources of electromagnetic noise in Hall effect imaging. Hall effect imaging employs large electrical pulses for signal generation and high sensitivity ultrasonic probes for signal reception. Coherent noise arises through various coupling mechanisms between the excitation pulse and the...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173469802000305
更新日期:1998-07-01 00:00:00
abstract::Statistical pattern recognition procedures allow a quantitative description of ultrasound-B-scan image texture. According to well-established animal models, different types of fatty liver disease were induced in female Wistar rats. For the correlation of the computerized ultrasound image with its underlying histology ...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173469001200302
更新日期:1990-07-01 00:00:00
abstract::Anova and "dummy variables" least squares regression methods are used to investigate the dependence of ultrasound propagation velocity on the presence or absence of fat and on the rank ordered level of cirrhosis in fixed human liver. Cirrhosis is found to affect velocity in a nonlinear fashion, while fat depresses the...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173468300500306
更新日期:1983-07-01 00:00:00
abstract::Attenuation measurements of various tissue mimicking phantoms and three different groups of patients were obtained using a modified commercial sector scanner. Estimates of attenuation were made using the spectral shift method with mean frequencies at different depths of a region of interest being obtained by both zero...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173468400600402
更新日期:1984-10-01 00:00:00
abstract::Transesophageal echocardiography (TEE) is an essential diagnostic tool in patients with poor transthoracic echocardiographic windows or when detailed imaging of structures distant from the chest wall is necessary. A real-time 3D TEE probe has been fabricated in our laboratory in order to increase the amount of informa...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173460402600402
更新日期:2004-10-01 00:00:00
abstract::This ex vivo study explores the relationship of ultrasonic attenuation and backscatter to dermal microarchitecture by comparing ultrasonic measurements of these parameters (11-27 MHz) to a microscopic analysis of three parameters describing the collagen distribution (mean thickness and spacing of collagen bundles alon...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173460602800103
更新日期:2006-01-01 00:00:00
abstract::A new online signal processing technique is described to reduce speckle noise in ultrasound images. In the imaging system, a focused piston transducer is divided into thirty-two sectors. In the receive mode, parallel signal processing arranges the sectors into eight maltese crosses. The rf signals of the perpendicular...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173468801000301
更新日期:1988-07-01 00:00:00
abstract::Acoustic radiation force impulse (ARFI) Surveillance of Subcutaneous Hemorrhage (ASSH) has been previously demonstrated to differentiate bleeding phenotype and responses to therapy in dogs and humans, but to date, the method has lacked experimental validation. This work explores experimental validation of ASSH in a po...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/0161734615617940
更新日期:2016-09-01 00:00:00
abstract::Our group has proposed the concept of subharmonic aided pressure estimation (SHAPE) utilizing microbubble-based ultrasound contrast agent signals for the noninvasive estimation of hydrostatic blood pressures. An experimental system for in vitro SHAPE was constructed based on two single-element transducers assembled co...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173461103300301
更新日期:2011-07-01 00:00:00
abstract::A Fourier transform (FT)-based technique for forming parallel receive beams has been previously employed to increase the imaging frame rate in ultrasonic imaging. However, the image quality in FT-based parallel reconstruction is degraded because differences in range focusing delays are ignored and a wide transmit beam...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173460302500201
更新日期:2003-04-01 00:00:00
abstract::Acoustic Radiation Force Impulse (ARFI) imaging is a method for characterizing local variations in tissue mechanical properties. In this method, a single ultrasonic transducer array is used to both apply temporally short localized radiation forces within tissue and to track the resulting displacements through time. In...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173460202400301
更新日期:2002-07-01 00:00:00
abstract::Hall effect imaging is an ultrasound-based method of mapping spatial variations in the dielectric constants of an acoustically-uniform sample. This paper presents three-dimensional Hall effect images of phantoms obtained by scanning a single transducer across a two-dimensional grid, effectively simulating two-dimensio...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173469902100303
更新日期:1999-07-01 00:00:00
abstract::Tracking large deformations in tissue using ultrasound can enable the reconstruction of nonlinear elastic parameters, but poses a challenge to displacement estimation algorithms. Such large deformations have to be broken up into steps, each of which contributes an estimation error to the final accumulated displacement...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/0161734613479246
更新日期:2013-04-01 00:00:00
abstract::Computer texture analysis methods use texture features that are traditionally chosen from a large set of fixed features known in literature. These fixed features are often not specifically designed to the problem at hand, and as a result they may have low discriminative power, and/or may be correlated. Increasing the ...
journal_title:Ultrasonic imaging
pub_type: 杂志文章,评审
doi:10.1177/016173469802000204
更新日期:1998-04-01 00:00:00
abstract::The methods of statistical pattern recognition have been applied to the problem of in vivo ultrasonic characterization of breast disease in humans. Backscattered A-mode signals obtained from a commercial pulse imaging system were used to generate a large set of potentially useful features. Using statistical tests, a s...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173468300500107
更新日期:1983-01-01 00:00:00
abstract::This paper describes a method for overcoming motion artifacts in synthetic aperture imaging. The method is based on a computer simulation study on the influence of target motion on synthetic aperture techniques. A region-based motion compensation approach is used in which only the axial motion is estimated and compens...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173460202400202
更新日期:2002-04-01 00:00:00
abstract::Portable ultrasound is recently emerging as a new medical imaging modality featuring high portability, easy connectivity, and real-time on-site diagnostic ability. However, it does not yet provide ultrasound elastography function that enables the diagnosis of malignant lesions using elastic properties. This is mainly ...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/0161734617716938
更新日期:2017-11-01 00:00:00