Phase-derivative imaging. II: Effects of beam diffraction and scatterer density.

Abstract:

:The potential of using the phase derivative (PD) of the radio-frequency echograms for producing 2-dimensional grey scale images was further investigated. The PD images were produced by five different algorithms, which according to the results described in the companion paper yield PD images dominated by the amplitude (envelope, ENV), mixed PD-AM images and pure PD images. These images are termed according to their algorithms: ZCS, zero crossing counter with squelch; ASS, analytic signal with squelch; ASW, analytic signal with Wiener kernel; UNP, unwrapped phase; and SAS, smoothed analytic signal. The rf data were obtained from simulations and from experiments with a tissue mimicking phantom. PD images were analysed by calculation of the first and second order grey level statistics: mean level, signal-to-noise ratio (SNR) and the full width at half maximum (FWHM) of the autocovariance functions (ACVF). These parameters were systematically investigated for a range of depths with respect to the transducer and a range of scatterer densities of the insonated medium. The UNP and SAS images do not suffer much from the diffraction effect but do not display much information about the scatterer density either. The ASW and ASS images qualitatively display beam diffraction effects similar to those of the AM images, with the exception of the mean value which is at the minimum in the focus, where the AM yields a sharp maximum at that depth. The mean and the SNR of the ASW and ASS images increase with increasing scatterer density and saturate at a density of 5000 cm-3. The mean value of the envelope, however, displays a square root dependency over the whole range. The axial and lateral FWHM of the ACVF of the UNP and SAS methods are not significantly dependent on the scatterer density and decrease with increasing density for the ASW and ASS images, as was observed in the envelope images. It may be concluded that ASW and ASS methods produce PD grey scale images which are equally well suited for the diagnosis of diffuse diseases of parenchymal tissues as conventional AM images. The smaller "speckle" size of the ASW images might be advantageous, for the detection of focal lesions, but the lesion contrast is found to be much lower than for the ENV.

journal_name

Ultrason Imaging

journal_title

Ultrasonic imaging

authors

Oosterveld BJ,Romijn RL,Thijssen JM

doi

10.1177/016173468901100301

subject

Has Abstract

pub_date

1989-07-01 00:00:00

pages

153-74

issue

3

eissn

0161-7346

issn

1096-0910

journal_volume

11

pub_type

杂志文章
  • A Variance-reduction Approach to Detection of the Thyroid-nodule Boundary on Ultrasound Images.

    abstract::To perform computer-aided diagnosis of the thyroid nodules on ultrasound images, the location and boundary of nodules should be clearly defined. However, the identification of thyroid nodule boundary is a difficult issue due to the biological characteristics of the nodules, the physics and quality of ultrasound imagin...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/0161734619839648

    authors: Chiu LY,Chen A

    更新日期:2019-07-01 00:00:00

  • A quantitative approach to speckle reduction via frequency compounding.

    abstract::Coherent speckle is a source of image noise in ultrasonic B-mode imaging. The use of multiple imaging frequencies has been suggested as a technique for speckle contrast reduction. This technique involves the averaging of images whose speckle patterns have been modified by a change in the spectrum of the transmitted or...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173468600800301

    authors: Trahey GE,Allison JW,Smith SW,von Ramm OT

    更新日期:1986-07-01 00:00:00

  • Characterization of tongue shape.

    abstract::Mathematical techniques are described for analyzing tongue shapes obtained with ultrasound images. The surface of the mid-sagittal section of the tongue was approximated by discrete points. In turn, these points were used to approximate position, slope and curvature of the tongue surface at a fixed time during speech....

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173468400600104

    authors: Morrish KA,Stone M,Sonies BC,Kurtz D,Shawker T

    更新日期:1984-01-01 00:00:00

  • Effective scatterer diameter estimates for broad scatterer size distributions.

    abstract::Acoustic form factors have been used to model the frequency dependence of acoustic scattering in phantoms and tissues. This work demonstrates that a broad range of scatterer sizes, individually well represented by Faran theory or a Gaussian form factor, is not accurately described by a single effective scatterer from ...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/0161734614534399

    authors: Nordberg EP,Hall TJ

    更新日期:2015-01-01 00:00:00

  • Mean scatterer spacing estimation in normal and thermally coagulated ex vivo bovine liver.

    abstract::The liver has been hypothesized to have a unique arrangement of microvasculature that presents as an arrangement of quasiperiodic scatterers to an interrogating ultrasound pulse. The mean scatterer spacing (MSS) of these quasiperiodic scatterers has been proposed as a useful quantitative ultrasound biomarker for chara...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/0161734613511232

    authors: Rubert N,Varghese T

    更新日期:2014-04-01 00:00:00

  • A comparison method for mean frequency estimators for Doppler ultrasound.

    abstract::Mean frequency estimators as used in pulsed Doppler ultrasound equipment should provide an accurate (quality) and consistent (robustness) estimate over a wide range of signal conditions. In a simplified signal model, the main parameters to consider are the noise level, mean frequency, bandwidth and power of both the D...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173469201400404

    authors: Brands PJ,Hoeks AP

    更新日期:1992-10-01 00:00:00

  • Ultrasonic backscatter and attenuation (11-27 MHz) variation with collagen fiber distribution in ex vivo human dermis.

    abstract::This ex vivo study explores the relationship of ultrasonic attenuation and backscatter to dermal microarchitecture by comparing ultrasonic measurements of these parameters (11-27 MHz) to a microscopic analysis of three parameters describing the collagen distribution (mean thickness and spacing of collagen bundles alon...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173460602800103

    authors: Bridal SL,Fournier C,Coron A,Leguerney I,Laugier P

    更新日期:2006-01-01 00:00:00

  • Variance and covariance of accumulated displacement estimates.

    abstract::Tracking large deformations in tissue using ultrasound can enable the reconstruction of nonlinear elastic parameters, but poses a challenge to displacement estimation algorithms. Such large deformations have to be broken up into steps, each of which contributes an estimation error to the final accumulated displacement...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/0161734613479246

    authors: Bayer M,Hall TJ

    更新日期:2013-04-01 00:00:00

  • Feasibility exploration of blood flow estimation by contrast-assisted Nakagami imaging.

    abstract::The microbubble contrast agent destruction/replenishment technique has been widely applied to ultrasound-based blood flow estimation. The rate of increase of the time-intensity curve (TIC) due to microbubbles flowing into the region of interest as measured from B-mode images closely reflects the flow velocity. In this...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173460803000301

    authors: Tsui PH,Yeh CK,Chang CC

    更新日期:2008-07-01 00:00:00

  • Deconvolution of in-vivo ultrasound B-mode images.

    abstract::An algorithm for deconvolution of medical ultrasound images is presented. The procedure involves estimation of the basic one-dimensional ultrasound pulse, determining the ratio of the covariance of the noise to the covariance of the reflection signal, and finally deconvolution of the rf signal from the transducer. Usi...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173469301500204

    authors: Jensen JA,Mathorne J,Gravesen T,Stage B

    更新日期:1993-04-01 00:00:00

  • Improved Fourier-transform-based parallel receive beam formation.

    abstract::A Fourier transform (FT)-based technique for forming parallel receive beams has been previously employed to increase the imaging frame rate in ultrasonic imaging. However, the image quality in FT-based parallel reconstruction is degraded because differences in range focusing delays are ignored and a wide transmit beam...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173460302500201

    authors: Li ML,Li PC

    更新日期:2003-04-01 00:00:00

  • Reconstructive ultrasound elasticity imaging for renal transplant diagnosis: kidney ex vivo results.

    abstract::It may be possible to diagnose and monitor scarring, inflammation and edema in transplant kidney using reconstructive ultrasound elasticity imaging. Kidney elasticity is expected to change dramatically with scar, and to a lesser degree, with acute inflammation and edema. The hypothesis that changes in kidney elasticit...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173460002200303

    authors: Emelianov SY,Lubinski MA,Skovoroda AR,Erkamp RQ,Leavey SF,Wiggins RC,O'Donnell M

    更新日期:2000-07-01 00:00:00

  • Autoregressive spectral estimation in ultrasonic scatterer size imaging.

    abstract::An autoregressive (AR) spectral estimation method was considered for the purpose of estimating scatterer size images. The variance and bias of the resulting estimates were compared with those using classical FFT periodograms for a range of input signal-to-noise ratios and echo-signal durations corresponding to various...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173469601800102

    authors: Chaturvedi P,Insana MF

    更新日期:1996-01-01 00:00:00

  • Assessment of Age-related Oxygenation Changes in Calf Skeletal Muscle by Photoacoustic Imaging: A Potential Tool for Peripheral Arterial Disease.

    abstract::Peripheral artery disease is often asymptomatic, and various imaging and nonimaging techniques have been used for assessment and monitoring treatments. This study is designed to demonstrate the ability of photoacoustic imaging to noninvasively determine changes in tissue oxygenation that occur in mice's hind limb skel...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/0161734619862287

    authors: Kirkham BM,Schultz SM,Ashi K,Sehgal CM

    更新日期:2019-09-01 00:00:00

  • Linear arrays for vibro-acoustography: a numerical simulation study.

    abstract::In this work, we study linear array beamforming for vibro-acoustography systems. The goal of this research is to assess the feasibility of vibro-acoustography imaging systems based on linear arrays for clinical applications. The vibro-acoustography transducer is designed with two arrays driven by two continuous-wave o...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173460402600101

    authors: Silva GT,Greenleaf JF,Fatemi M

    更新日期:2004-01-01 00:00:00

  • Diffraction tomography using arbitrary transmitter and receiver surfaces.

    abstract::The theory of diffraction tomography for two-dimensional objects within the Born approximation is presented for cases where the scattered field is measured over arbitrarily shaped boundaries surrounding the object. Reconstruction algorithms are presented for both plane wave (parallel beam) and cylindrical wave (fan be...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173468400600207

    authors: Devaney AJ,Beylkin G

    更新日期:1984-04-01 00:00:00

  • Adaptive imaging using an optimal receive aperture size.

    abstract::Sidelobe contribution from off-axis targets degrades image quality in a coherent array imaging system. In ultrasound imaging, focusing errors resulting from sound-velocity inhomogeneities in human tissue--also known as phase aberrations reduce the coherence of the received signals and elevate the sidelobe level. This ...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173460502700205

    authors: Li ML,Huang SW,Ustüner K,Li PC

    更新日期:2005-04-01 00:00:00

  • Computerized quantification analysis of left ventricular wall motion from echocardiograms.

    abstract::Two-dimensional echocardiography (2-D echo) imaging is a more attractive clinical tool than other modalities that either involve radiation exposure or are too slow to image heart motion in real-time. Computer-aided analysis of left ventricular(LV) wall motion provides quantitative parameters for diagnosis. This study ...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173469701900204

    authors: Chen T,Chen TP,Tsai LM

    更新日期:1997-04-01 00:00:00

  • Adaptive texture feature extraction with application to ultrasonic image analysis.

    abstract::Computer texture analysis methods use texture features that are traditionally chosen from a large set of fixed features known in literature. These fixed features are often not specifically designed to the problem at hand, and as a result they may have low discriminative power, and/or may be correlated. Increasing the ...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章,评审

    doi:10.1177/016173469802000204

    authors: Huisman HJ,Thijssen JM

    更新日期:1998-04-01 00:00:00

  • A method for in vitro mapping of ultrasonic speed and density in breast tissue.

    abstract::A method has been developed for mapping density and ultrasonic speed in 1 mm thick slices of soft tissue with a resolution of about 1 mm. Tests using phantom sections have verified the accuracy and resolution of the ultrasonic speed maps. The method has been applied to breast tissues of three patients including tumors...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173469101300105

    authors: Yang JN,Murphy AD,Madsen EL,Zagzebski JA,Gilchrist KW,Frank GR,Macdonald MC,Millard CA,Faraggi A,Jaramillo CA

    更新日期:1991-01-01 00:00:00

  • Observations of tissue response to acoustic radiation force: opportunities for imaging.

    abstract::Acoustic Radiation Force Impulse (ARFI) imaging is a method for characterizing local variations in tissue mechanical properties. In this method, a single ultrasonic transducer array is used to both apply temporally short localized radiation forces within tissue and to track the resulting displacements through time. In...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173460202400301

    authors: Nightingale K,Bentley R,Trahey G

    更新日期:2002-07-01 00:00:00

  • Dispersion and shear modulus measurements of porcine liver.

    abstract::A narrow-band ultrasonic shear-wave imaging technique for estimating phase speed was applied to fresh and thermally damaged porcine liver in vitro. Two constitutive models were applied to the measurements to represent rheological behavior of the tissue and estimate the complex shear modulus at frequencies between 50 a...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173461003200405

    authors: Orescanin M,Qayyum MA,Toohey KS,Insana MF

    更新日期:2010-10-01 00:00:00

  • Statistical relationship between ultrasound echo envelope and envelope peak.

    abstract::This study shows that the amplitude information of ultrasound echoes is carried mainly by the envelope peaks (EPs). It is first shown that the EPs in an A-line represent the maximum number of independent amplitude data. It is then demonstrated that the entire envelope could be approximately reconstructed from the EPs....

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173468801000403

    authors: He P

    更新日期:1988-10-01 00:00:00

  • Frequency diversity speckle processing.

    abstract::Ultrasonic waveform data from a tissue-mimicking phantom containing low contrast targets was digitized, stored and processed prior to creating and displaying ultrasonic images. Speckle reduction was performed by digital filtering of the waveform data with appropriately spaced and weighted digital filters, prior to bot...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173468700900202

    authors: Gehlbach SM,Sommer FG

    更新日期:1987-04-01 00:00:00

  • Skeletal Muscle Fatigue State Evaluation with Ultrasound Image Entropy.

    abstract::Muscle fatigue often occurs over a long period of exercise, and it can increase the risk of muscle injury. Evaluating the state of muscle fatigue can avoid unnecessary overtraining and injury of the muscle. Ultrasound imaging can non-invasively visualize muscle tissue in real-time. Image entropy is commonly used to ch...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/0161734620952683

    authors: Li P,Yang X,Yin G,Guo J

    更新日期:2020-11-01 00:00:00

  • Time reversal focusing applied to lithotripsy.

    abstract::Time reversal of ultrasonic field allows a very efficient approach to focusing pulsed ultrasonic waves through lossless inhomogeneous media. Time reversal mirrors (TRM) are made of large transducer arrays, allowing the incident acoustic field to be sampled, time reversed and re-emitted. Time reversal processing permit...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章,评审

    doi:10.1177/016173469601800202

    authors: Thomas JL,Wu F,Fink M

    更新日期:1996-04-01 00:00:00

  • Effects of transmit focusing on finite amplitude distortion based second harmonic generation.

    abstract::Generation of the second harmonic signal was studied for finite amplitude distortion based harmonic imaging. Acoustic field amplitudes along the range axis of a fixed focus transducer were measured using a PVDF needle hydrophone. Results indicated that on-axis amplitudes strongly depended on the f-number at both the f...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173469902100401

    authors: Li PC,Shen CC

    更新日期:1999-10-01 00:00:00

  • Shielding of piezoelectric ultrasonic probes in Hall effect imaging.

    abstract::This paper addresses significant sources of electromagnetic noise in Hall effect imaging. Hall effect imaging employs large electrical pulses for signal generation and high sensitivity ultrasonic probes for signal reception. Coherent noise arises through various coupling mechanisms between the excitation pulse and the...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173469802000305

    authors: Wen H,Bennett E,Wiesler DG

    更新日期:1998-07-01 00:00:00

  • Experimental Validation of ARFI Surveillance of Subcutaneous Hemorrhage (ASSH) Using Calibrated Infusions in a Tissue-Mimicking Model and Dogs.

    abstract::Acoustic radiation force impulse (ARFI) Surveillance of Subcutaneous Hemorrhage (ASSH) has been previously demonstrated to differentiate bleeding phenotype and responses to therapy in dogs and humans, but to date, the method has lacked experimental validation. This work explores experimental validation of ASSH in a po...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/0161734615617940

    authors: Geist RE,DuBois CH,Nichols TC,Caughey MC,Merricks EP,Raymer R,Gallippi CM

    更新日期:2016-09-01 00:00:00

  • Reduction of the clutter component in Doppler ultrasound signals based on singular value decomposition: a simulation study.

    abstract::In pulsed Doppler ultrasound systems, the ultrasound radiofrequency (RF) signals received can be employed to estimate noninvasively the time-dependent blood velocity distribution within and artery. The RF signals are composed of signals originating from clutter (e.g., vessel walls) and scatterers (e.g., red blood cell...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173469701900101

    authors: Ledoux LA,Brands PJ,Hoeks AP

    更新日期:1997-01-01 00:00:00