A fast and stable vascular deformation scheme for interventional surgery training system.

Abstract:

BACKGROUND:The emergence and development of robot assistant interventional vascular surgery technologies have benefited many patients with cardiovascular or cerebrovascular diseases. Due to the absence of effective training measures, these new advanced technologies have not been fully utilized and only few experienced surgeons can perform such complicated surgeries so far. In order to solve such problems, virtual reality based vascular interventional surgery training system, a promising way to train young surgeons or assist experienced surgeons to perform surgery, has been widely studied. METHODS:In this paper, we mainly conduct a thorough study on both reliable deformation and high real-time performance of an interactive surgery training system. An efficient hybrid geometric blood vessel model which handles the collision detection query and vascular deformation calculation separately is employed to enhance the real-time performance of our surgery training system. In addition, a position-based dynamic approach with volume conservation constraint is used to improve the vascular deformation result. Finally, a hash table based spatial adaptive acceleration algorithm which makes the training system much more efficient and reliable is described. RESULTS:Several necessary experiments are conducted to validate the vascular deformation scheme presented in this paper. From the results we can see that the position-based dynamic modeling method with volume conservation constraint can prevent the vascular deformation from the issue of penetration. In addition, the deformation calculation with spatial acceleration algorithm has enhanced the real-time performance significantly. CONCLUSION:The corresponding experimental results indicate that both the hybrid geometric blood vessel model and the hash table based spatial adaptive acceleration algorithm can enhance the performance of our surgery training system greatly without losing the deformation accuracy.

journal_name

Biomed Eng Online

authors

Ye X,Zhang J,Li P,Wang T,Guo S

doi

10.1186/s12938-016-0148-3

subject

Has Abstract

pub_date

2016-04-06 00:00:00

pages

35

issn

1475-925X

pii

10.1186/s12938-016-0148-3

journal_volume

15

pub_type

杂志文章
  • Fine-grain recordings of the electrically evoked compound action potential amplitude growth function in cochlear implant recipients.

    abstract:BACKGROUND:In cochlear implants (CI) measuring the electrically evoked compound action potential (ECAP) has become an important tool for verifying the electrode-nerve interface as well as establishing a basis for a map to program the speech processor. In a standard clinical setup recordings are averaged over 25-100 rep...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-018-0588-z

    authors: Gärtner L,Lenarz T,Büchner A

    更新日期:2018-10-19 00:00:00

  • EZ Entropy: a software application for the entropy analysis of physiological time-series.

    abstract:BACKGROUND:Entropy analysis has been attracting increasing attentions in the recent two or three decades. It assesses complexity, or irregularity, of time-series which is extraordinarily relevant to physiology and diseases as demonstrated by tremendous studies. However, the complexity can hardly be appreciated by tradi...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-019-0650-5

    authors: Li P

    更新日期:2019-03-20 00:00:00

  • Low-cost equipment for the evaluation of reach and grasp in post-stroke individuals: a pilot study.

    abstract:BACKGROUND:Reach-grasp movements are motor components commonly affected after stroke and directly related to the independence of these individuals. Evaluations of these activities can be performed using clinical instruments and assessed by detailed and costly kinematic analyses. The aim of this study was to develop an ...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-020-0758-7

    authors: Gomes CLA,Cacho RO,Nobrega VTB,de A Confessor EM,de Farias EEM,Neto JLF,de Araújo DS,de S Medeiros AL,Barreto RL,Cacho EWA

    更新日期:2020-03-04 00:00:00

  • Influence of the measurement method of features in ultrasound images of the thyroid in the diagnosis of Hashimoto's disease.

    abstract:INTRODUCTION:This paper shows the influence of a measurement method of features in the diagnosis of Hashimoto's disease. Sensitivity of the algorithm to changes in the parameters of the ROI, namely shift, resizing and rotation, has been presented. The obtained results were also compared to the methods known from the li...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-11-91

    authors: Koprowski R,Korzyńska A,Wróbel Z,Zieleźnik W,Witkowska A,Małyszek J,Wójcik W

    更新日期:2012-11-28 00:00:00

  • A high-resolution binocular video-oculography system: assessment of pupillary light reflex and detection of an early incomplete blink and an upward eye movement.

    abstract:BACKGROUND:The pupillary light reflex characterizes the direct and consensual response of the eye to the perceived brightness of a stimulus. It has been used as indicator of both neurological and optic nerve pathologies. As with other eye reflexes, this reflex constitutes an almost instantaneous movement and is linked ...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-015-0016-6

    authors: Espinosa J,Roig AB,Pérez J,Mas D

    更新日期:2015-03-13 00:00:00

  • A computational model study of the influence of the anatomy of the circle of willis on cerebral hyperperfusion following carotid artery surgery.

    abstract:BACKGROUND:Cerebral hyperperfusion syndrome develops in a small subset of patients following carotid artery surgery (CAS) performed to treat severe carotid artery stenosis. This syndrome has been found to have a close correlation with cerebral hyperperfusion occurring after CAS. The purpose of this study is to investig...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-10-84

    authors: Liang F,Fukasaku K,Liu H,Takagi S

    更新日期:2011-09-23 00:00:00

  • Monitoring and analysis of dynamic growth of human embryonic stem cells: comparison of automated instrumentation and conventional culturing methods.

    abstract:BACKGROUND:Human embryonic stem cells (hESCs) are a potential source of cells for use in regenerative medicine. Automation of culturing, monitoring and analysis is crucial for fast and reliable optimization of hESC culturing methods. Continuous monitoring of living cell cultures can reveal more information and is faste...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-6-11

    authors: Narkilahti S,Rajala K,Pihlajamäki H,Suuronen R,Hovatta O,Skottman H

    更新日期:2007-04-12 00:00:00

  • Designing and testing scene enhancement algorithms for patients with retina degenerative disorders.

    abstract:BACKGROUND:Retina degenerative disorders represent the primary cause of blindness in UK and in the developed world. In particular, Age Related Macular Degeneration (AMD) and Retina Pigmentosa (RP) diseases are of interest to this study. We have therefore created new image processing algorithms for enhancing the visual ...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-9-27

    authors: Al-Atabany WI,Memon MA,Downes SM,Degenaar PA

    更新日期:2010-06-18 00:00:00

  • In vivo myograph measurement of muscle contraction at optimal length.

    abstract:BACKGROUND:Current devices for measuring muscle contraction in vivo have limited accuracy in establishing and re-establishing the optimum muscle length. They are variable in the reproducibility to determine the muscle contraction at this length, and often do not maintain precise conditions during the examination. Conse...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-6-1

    authors: Rahe-Meyer N,Weilbach C,Karst M,Pawlak M,Ahmed A,Piepenbrock S,Winterhalter M

    更新日期:2007-01-02 00:00:00

  • Heart rate analysis in normal subjects of various age groups.

    abstract:BACKGROUND:Analysis of heart rate variation (HRV) has become a popular noninvasive tool for assessing the activities of the autonomic nervous system (ANS). HRV analysis is based on the concept that fast fluctuations may specifically reflect changes of sympathetic and vagal activity. It shows that the structure generati...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-3-24

    authors: Acharya U R,Kannathal N,Sing OW,Ping LY,Chua T

    更新日期:2004-07-20 00:00:00

  • Classification of voice disorder in children with cochlear implantation and hearing aid using multiple classifier fusion.

    abstract:BACKGROUND:Speech production and speech phonetic features gradually improve in children by obtaining audio feedback after cochlear implantation or using hearing aids. The aim of this study was to develop and evaluate automated classification of voice disorder in children with cochlear implantation and hearing aids. ME...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-10-3

    authors: Mahmoudi Z,Rahati S,Ghasemi MM,Asadpour V,Tayarani H,Rajati M

    更新日期:2011-01-14 00:00:00

  • Automatic diagnosis of imbalanced ophthalmic images using a cost-sensitive deep convolutional neural network.

    abstract:BACKGROUND:Ocular images play an essential role in ophthalmological diagnoses. Having an imbalanced dataset is an inevitable issue in automated ocular diseases diagnosis; the scarcity of positive samples always tends to result in the misdiagnosis of severe patients during the classification task. Exploring an effective...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-017-0420-1

    authors: Jiang J,Liu X,Zhang K,Long E,Wang L,Li W,Liu L,Wang S,Zhu M,Cui J,Liu Z,Lin Z,Li X,Chen J,Cao Q,Li J,Wu X,Wang D,Wang J,Lin H

    更新日期:2017-11-21 00:00:00

  • Automatic QRS complex detection using two-level convolutional neural network.

    abstract:BACKGROUND:The QRS complex is the most noticeable feature in the electrocardiogram (ECG) signal, therefore, its detection is critical for ECG signal analysis. The existing detection methods largely depend on hand-crafted manual features and parameters, which may introduce significant computational complexity, especiall...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-018-0441-4

    authors: Xiang Y,Lin Z,Meng J

    更新日期:2018-01-29 00:00:00

  • In-vivo coronary flow profiling based on biplane angiograms: influence of geometric simplifications on the three-dimensional reconstruction and wall shear stress calculation.

    abstract:BACKGROUND:Clinical studies suggest that local wall shear stress (WSS) patterns modulate the site and the progression of atherosclerotic lesions. Computational fluid dynamics (CFD) methods based on in-vivo three-dimensional vessel reconstructions have recently been shown to provide prognostically relevant WSS data. Thi...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-5-39

    authors: Wellnhofer E,Goubergrits L,Kertzscher U,Affeld K

    更新日期:2006-06-14 00:00:00

  • Influence of model boundary conditions on blood flow patterns in a patient specific stenotic right coronary artery.

    abstract:BACKGROUND:In literature, the effect of the inflow boundary condition was investigated by examining the impact of the waveform and the shape of the spatial profile of the inlet velocity on the cardiac hemodynamics. However, not much work has been reported on comparing the effect of the different combinations of the inl...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-14-S1-S6

    authors: Liu B,Zheng J,Bach R,Tang D

    更新日期:2015-01-01 00:00:00

  • Quantification of compensatory processes of postnatal hypoxia in newborn piglets applying short-term nonlinear dynamics analysis.

    abstract:BACKGROUND:Newborn mammals suffering from moderate hypoxia during or after birth are able to compensate a transitory lack of oxygen by adapting their vital functions. Exposure to hypoxia leads to an increase in the sympathetic tone causing cardio-respiratory response, peripheral vasoconstriction and vasodilatation in p...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-10-88

    authors: Schulz S,Reulecke S,Eiselt M,Schwab K,Witte H,Walter B,Bauer R,Voss A

    更新日期:2011-10-03 00:00:00

  • A numerical study of the effect of varied blood pressure on the stability of carotid atherosclerotic plaque.

    abstract:BACKGROUND:Blood pressure (BP) is associated with early atherosclerosis and plaque rupture because the BP variability can significantly affect the blood flow velocity and shear stress over the plaque. However, the mechanical response of BP variability to the plaque remains unclear. Therefore, we investigated the correl...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-13-152

    authors: Xiong H,Liu X,Tian X,Pu L,Zhang H,Lu M,Huang W,Zhang YT

    更新日期:2014-11-20 00:00:00

  • Temporal fluctuations of tremor signals from inertial sensor: a preliminary study in differentiating Parkinson's disease from essential tremor.

    abstract:BACKGROUND:Parkinson's disease (PD) and essential tremor (ET) are the two most common movement disorders but the rate of misdiagnosis rate in these disorders is high due to similar characteristics of tremor. The purpose of the study is to present: (a) a solution to identify PD and ET patients by using the novel measure...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-015-0098-1

    authors: Thanawattano C,Pongthornseri R,Anan C,Dumnin S,Bhidayasiri R

    更新日期:2015-11-04 00:00:00

  • Challenges on optimization of 3D-printed bone scaffolds.

    abstract::Advances in biomaterials and the need for patient-specific bone scaffolds require modern manufacturing approaches in addition to a design strategy. Hybrid materials such as those with functionally graded properties are highly needed in tissue replacement and repair. However, their constituents, proportions, sizes, con...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章,评审

    doi:10.1186/s12938-020-00810-2

    authors: Bahraminasab M

    更新日期:2020-09-03 00:00:00

  • The assessment of xenogeneic bone immunotoxicity and risk management study.

    abstract:BACKGROUND:Xenogeneic bone has been widely used in a variety of clinical bone-related disease to promote bone healing and restore bone defects. However, the adverse effects of immune system limit its application in the clinic. The aim of this study was to evaluate xenogeneic bone safety of immunotoxicity and explore th...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-019-0729-z

    authors: Sun X,Liu C,Shi Y,Li C,Sun L,Hou L,Wang X

    更新日期:2019-11-14 00:00:00

  • Computational fluid dynamics simulations of blood flow regularized by 3D phase contrast MRI.

    abstract:BACKGROUND:Phase contrast magnetic resonance imaging (PC-MRI) is used clinically for quantitative assessment of cardiovascular flow and function, as it is capable of providing directly-measured 3D velocity maps. Alternatively, vascular flow can be estimated from model-based computation fluid dynamics (CFD) calculations...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-015-0104-7

    authors: Rispoli VC,Nielsen JF,Nayak KS,Carvalho JL

    更新日期:2015-11-26 00:00:00

  • The approximate entropy of the electromyographic signals of tremor correlates with the osmotic fragility of human erythrocytes.

    abstract:BACKGROUND:The main problem of tremor is the damage caused to the quality of the life of patients, especially those at more advanced ages. There is not a consensus yet about the origins of this disorder, but it can be examined in the correlations between the biological signs of aging and the tremor characteristics. ME...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-9-29

    authors: Mansur PH,Cury LK,Leite JO,Pereira AA,Penha-Silva N,Andrade AO

    更新日期:2010-06-22 00:00:00

  • Feature extraction for the analysis of colon status from the endoscopic images.

    abstract:BACKGROUND:Extracting features from the colonoscopic images is essential for getting the features, which characterizes the properties of the colon. The features are employed in the computer-assisted diagnosis of colonoscopic images to assist the physician in detecting the colon status. METHODS:Endoscopic images contai...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925x-2-9

    authors: Tjoa MP,Krishnan SM

    更新日期:2003-04-08 00:00:00

  • Biomechanical investigation of dynamic hip screw and wire fixation on an unstable intertrochanteric fracture.

    abstract:BACKGROUND:Although use of a dynamic hip screw (DHS) for stable intertrochanteric hip fracture fixation has been successfully applied in fracture healing for more than 20 years, DHS fixation on unstable intertrochanteric fractures still has a high failure rate, especially in patients with osteoporosis. Although the wir...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-019-0663-0

    authors: Wu HF,Chang CH,Wang GJ,Lai KA,Chen CH

    更新日期:2019-04-24 00:00:00

  • Flow and wall shear stress in end-to-side and side-to-side anastomosis of venous coronary artery bypass grafts.

    abstract:PURPOSE:Coronary artery bypass graft (CABG) surgery represents the standard treatment of advanced coronary artery disease. Two major types of anastomosis exist to connect the graft to the coronary artery, i.e., by using an end-to-side or a side-to-side anastomosis. There is still controversy because of the differences ...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-6-35

    authors: Frauenfelder T,Boutsianis E,Schertler T,Husmann L,Leschka S,Poulikakos D,Marincek B,Alkadhi H

    更新日期:2007-09-26 00:00:00

  • Evaluation of flow changes after telescopic stenting of a giant fusiform aneurysm of the vertebrobasilar junction.

    abstract:BACKGROUND:The use of flow-diverters for non-saccular cerebral posterior circulation aneurysms requires complex deployment techniques and is associated with high mortality and morbidity. Therefore, further studies are required to clarify the effect of stenting on post-treatment hemodynamics in such aneurysms. In this s...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-019-0699-1

    authors: Sindeev S,Kirschke JS,Prothmann S,Frolov S,Liepsch D,Berg P,Zimmer C,Friedrich B

    更新日期:2019-07-24 00:00:00

  • PDE based scheme for multi-modal medical image watermarking.

    abstract:BACKGROUND:This work deals with copyright protection of digital images, an issue that needs protection of intellectual property rights. It is an important issue with a large number of medical images interchanged on the Internet every day. So, it is a challenging task to ensure the integrity of received images as well a...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-015-0101-x

    authors: Aherrahrou N,Tairi H

    更新日期:2015-11-25 00:00:00

  • Two-hierarchical nonnegative matrix factorization distinguishing the fluorescent targets from autofluorescence for fluorescence imaging.

    abstract:BACKGROUND:Nonnegative matrix factorization (NMF) has been used in blind fluorescence unmixing for multispectral in-vivo fluorescence imaging, which decomposes a mixed source data into a set of constituent fluorescence spectra and corresponding concentrations. However, most classical NMF algorithms have ill convergence...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-015-0107-4

    authors: Huang S,Zhao Y,Qin B

    更新日期:2015-12-15 00:00:00

  • Developing functional workspace for the movement of trunk circumduction in healthy young subjects: a reliability study.

    abstract:BACKGROUND:The lumbar range of motion has traditionally been used to assess disability in patients with low back disorders. Controversy exists about how movement ranges in static positions or in a single straight plane is related to the functional status of the patients. The trunk circumduction, as the result of neurom...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-12-4

    authors: Cheng SC,Hsu CH,Ting YT,Kuo LC,Lin RM,Su FC

    更新日期:2013-01-11 00:00:00

  • Study of probe-sample distance for biomedical spectra measurement.

    abstract:BACKGROUND:Fiber-based optical spectroscopy has been widely used for biomedical applications. However, the effect of probe-sample distance on the collection efficiency has not been well investigated. METHOD:In this paper, we presented a theoretical model to maximize the illumination and collection efficiency in design...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-10-95

    authors: Wang B,Fan S,Li L,Wang C

    更新日期:2011-11-02 00:00:00