PDE based scheme for multi-modal medical image watermarking.

Abstract:

BACKGROUND:This work deals with copyright protection of digital images, an issue that needs protection of intellectual property rights. It is an important issue with a large number of medical images interchanged on the Internet every day. So, it is a challenging task to ensure the integrity of received images as well as authenticity. Digital watermarking techniques have been proposed as valid solution for this problem. METHODS:It is worth mentioning that the Region Of Interest (ROI)/Region Of Non Interest (RONI) selection can be seen as a significant limitation from which suffers most of ROI/RONI based watermarking schemes and that in turn affects and limit their applicability in an effective way. Generally, the ROI/RONI is defined by a radiologist or a computer-aided selection tool. And thus, this will not be efficient for an institute or health care system, where one has to process a large number of images. Therefore, developing an automatic ROI/RONI selection is a challenge task. The major aim of this work is to develop an automatic selection algorithm of embedding region based on the so called Partial Differential Equation (PDE) method. Thus avoiding ROI/RONI selection problems including: (1) computational overhead, (2) time consuming, and (3) modality dependent selection. RESULTS:The algorithm is evaluated in terms of imperceptibility, robustness, tamper localization and recovery using MRI, Ultrasound, CT and X-ray grey scale medical images. From experimental results that we have conducted on a database of 100 medical images of four modalities, it can be inferred that our method can achieve high imperceptibility, while showing good robustness against attacks. Furthermore, the experiment results confirm the effectiveness of the proposed algorithm in detecting and recovering the various types of tampering. The highest PSNR value reached over the 100 images is 94,746 dB, while the lowest PSNR value is 60,1272 dB, which demonstrates the higher imperceptibility nature of the proposed method. Moreover, the Normalized Correlation (NC) between the original watermark and the corresponding extracted watermark for 100 images is computed. We get a NC value greater than or equal to 0.998. This indicates that the extracted watermark is very similar to the original watermark for all modalities. CONCLUSION:The key features of our proposed method are to (1) increase the robustness of the watermark against attacks; (2) provide more transparency to the embedded watermark. (3) provide more authenticity and integrity protection of the content of medical images. (4) provide minimum ROI/RONI selection complexity.

journal_name

Biomed Eng Online

authors

Aherrahrou N,Tairi H

doi

10.1186/s12938-015-0101-x

subject

Has Abstract

pub_date

2015-11-25 00:00:00

pages

108

issn

1475-925X

pii

10.1186/s12938-015-0101-x

journal_volume

14

pub_type

杂志文章
  • The use of chilled condensers for the recovery of perfluorocarbon liquid in an experimental model of perfluorocarbon vapour loss during neonatal partial liquid ventilation.

    abstract:BACKGROUND:Perfluorocarbon (PFC) vapour in the expired gases during partial liquid ventilation should be prevented from entering the atmosphere and recovered for potential reuse. This study aimed to determine how much PFC liquid could be recovered using a conventional humidified neonatal ventilator with chilled condens...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-6-19

    authors: Dunster KR,Davies MW,Fraser JF

    更新日期:2007-05-31 00:00:00

  • Investigations concerning the application of the cross-correlation method in cardiac output measurements.

    abstract:BACKGROUND:In spite of numerous non-invasive examinations the "gold clinical standard" of cardiac output measurements is the invasive pulmonary artery catheterization by means of the Swan-Ganz catheter and the application of the thermodilution method to estimate the blood flow. The results obtained by means of thermodi...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-11-24

    authors: Gawlikowski M,Pustelny T

    更新日期:2012-05-20 00:00:00

  • A finite element method model to simulate laser interstitial thermo therapy in anatomical inhomogeneous regions.

    abstract:BACKGROUND:Laser Interstitial ThermoTherapy (LITT) is a well established surgical method. The use of LITT is so far limited to homogeneous tissues, e.g. the liver. One of the reasons is the limited capability of existing treatment planning models to calculate accurately the damage zone. The treatment planning in inhomo...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-4-2

    authors: Mohammed Y,Verhey JF

    更新日期:2005-01-04 00:00:00

  • Correlations between carotid plaque progression and mechanical stresses change sign over time: a patient follow up study using MRI and 3D FSI models.

    abstract:BACKGROUND:Increasing evidence suggests that mechanisms governing advanced plaque progression may be different from those for early progression and require further investigation. Serial MRI data and 3D fluid-structure interaction (FSI) models were employed to identify possible correlations between mechanical stresses a...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-12-105

    authors: Tang D,Yang C,Canton G,Wu Z,Hatsukami T,Yuan C

    更新日期:2013-10-14 00:00:00

  • Heart rate variability analysis using robust period detection.

    abstract:OBJECTIVE:Heart rate variability (HRV) analysis, which is an important tool for activity assessment of the cardiac autonomic nervous system, very often includes the estimation of power spectra for series of interbeat intervals (IBI). Ectopic beats and artifacts have a destructive effect on the standard methods (Fourier...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-13-138

    authors: Skotte JH,Kristiansen J

    更新日期:2014-09-23 00:00:00

  • Noise reduction of diffusion tensor images by sparse representation and dictionary learning.

    abstract:BACKGROUND:The low quality of diffusion tensor image (DTI) could affect the accuracy of oncology diagnosis. METHODS:We present a novel sparse representation based denoising method for three dimensional DTI by learning adaptive dictionary with the context redundancy between neighbor slices. In this study, the context r...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-015-0116-3

    authors: Kong Y,Li Y,Wu J,Shu H

    更新日期:2016-01-13 00:00:00

  • The assessment of xenogeneic bone immunotoxicity and risk management study.

    abstract:BACKGROUND:Xenogeneic bone has been widely used in a variety of clinical bone-related disease to promote bone healing and restore bone defects. However, the adverse effects of immune system limit its application in the clinic. The aim of this study was to evaluate xenogeneic bone safety of immunotoxicity and explore th...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-019-0729-z

    authors: Sun X,Liu C,Shi Y,Li C,Sun L,Hou L,Wang X

    更新日期:2019-11-14 00:00:00

  • Computational and experimental assessment of influences of hemodynamic shear stress on carotid plaque.

    abstract:BACKGROUND:Studies have identified hemodynamic shear stress as an important determinant of endothelial function and atherosclerosis. In this study, we assess the influences of hemodynamic shear stress on carotid plaques. METHODS:Carotid stenosis phantoms with three severity (30, 50, 70%) were made from 10% polyvinyl a...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-017-0386-z

    authors: Zhou H,Meng L,Zhou W,Xin L,Xia X,Li S,Zheng H,Niu L

    更新日期:2017-07-29 00:00:00

  • Influence of the measurement method of features in ultrasound images of the thyroid in the diagnosis of Hashimoto's disease.

    abstract:INTRODUCTION:This paper shows the influence of a measurement method of features in the diagnosis of Hashimoto's disease. Sensitivity of the algorithm to changes in the parameters of the ROI, namely shift, resizing and rotation, has been presented. The obtained results were also compared to the methods known from the li...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-11-91

    authors: Koprowski R,Korzyńska A,Wróbel Z,Zieleźnik W,Witkowska A,Małyszek J,Wójcik W

    更新日期:2012-11-28 00:00:00

  • The effect of inlet and outlet boundary conditions in image-based CFD modeling of aortic flow.

    abstract:BACKGROUND:Computational modeling of cardiovascular flow is a growing and useful field, but such simulations usually require the researcher to guess the flow's inlet and outlet conditions since they are difficult and expensive to measure. It is critical to determine the amount of uncertainty introduced by these assumpt...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-018-0497-1

    authors: Madhavan S,Kemmerling EMC

    更新日期:2018-05-30 00:00:00

  • Effect of gamma radiation and accelerated aging on the mechanical and thermal behavior of HDPE/HA nano-composites for bone tissue regeneration.

    abstract:BACKGROUND:The replacement of hard tissues demands biocompatible and sometimes bioactive materials with properties similar to those of bone. Nano-composites made of biocompatible polymers and bioactive inorganic nano particles such as HDPE/HA have attracted attention as permanent bone substitutes due to their excellent...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-12-95

    authors: Alothman OY,Almajhdi FN,Fouad H

    更新日期:2013-09-24 00:00:00

  • Challenges, issues and trends in fall detection systems.

    abstract::Since falls are a major public health problem among older people, the number of systems aimed at detecting them has increased dramatically over recent years. This work presents an extensive literature review of fall detection systems, including comparisons among various kinds of studies. It aims to serve as a referenc...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章,评审

    doi:10.1186/1475-925X-12-66

    authors: Igual R,Medrano C,Plaza I

    更新日期:2013-07-06 00:00:00

  • 3D kernel-density stochastic model for more personalized glycaemic control: development and in-silico validation.

    abstract:BACKGROUND:The challenges of glycaemic control in critically ill patients have been debated for 20 years. While glycaemic control shows benefits inter- and intra-patient metabolic variability results in increased hypoglycaemia and glycaemic variability, both increasing morbidity and mortality. Hence, current recommenda...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-019-0720-8

    authors: Uyttendaele V,Knopp JL,Davidson S,Desaive T,Benyo B,Shaw GM,Chase JG

    更新日期:2019-10-22 00:00:00

  • Study of probe-sample distance for biomedical spectra measurement.

    abstract:BACKGROUND:Fiber-based optical spectroscopy has been widely used for biomedical applications. However, the effect of probe-sample distance on the collection efficiency has not been well investigated. METHOD:In this paper, we presented a theoretical model to maximize the illumination and collection efficiency in design...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-10-95

    authors: Wang B,Fan S,Li L,Wang C

    更新日期:2011-11-02 00:00:00

  • Exploiting nonlinear recurrence and fractal scaling properties for voice disorder detection.

    abstract:BACKGROUND:Voice disorders affect patients profoundly, and acoustic tools can potentially measure voice function objectively. Disordered sustained vowels exhibit wide-ranging phenomena, from nearly periodic to highly complex, aperiodic vibrations, and increased "breathiness". Modelling and surrogate data studies have s...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-6-23

    authors: Little MA,McSharry PE,Roberts SJ,Costello DA,Moroz IM

    更新日期:2007-06-26 00:00:00

  • Identifying molecular subtypes related to clinicopathologic factors in pancreatic cancer.

    abstract:BACKGROUND:Pancreatic ductal adenocarcinoma (PDAC) is one of the most lethal tumors and usually presented with locally advanced and distant metastasis disease, which prevent curative resection or treatments. In this regard, we considered identifying molecular subtypes associated with clinicopathological factor as progn...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-13-S2-S5

    authors: Kim S,Kang M,Lee S,Bae S,Han S,Jang JY,Park T

    更新日期:2014-01-01 00:00:00

  • Novel flexible cap for application of transcranial electrical stimulation: a usability study.

    abstract:BACKGROUND:Advances in transcranial electrical stimulation (tES) are hampered by the conventional rubber electrodes manually attached to the head with rubber bands. This procedure limits montages to a few electrodes, is error prone with respect to electrode configurations and is burdensome for participants and operator...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-020-00792-1

    authors: Hunold A,Ortega D,Schellhorn K,Haueisen J

    更新日期:2020-06-17 00:00:00

  • Novel dynamic corneal response parameters in a practice use: a critical review.

    abstract:BACKGROUND:Non-contact tonometers based on the method using air puff and Scheimpflug's fast camera are one of the latest devices allowing the measurement of intraocular pressure and additional biomechanical parameters of the cornea. Biomechanical features significantly affect changes in intraocular pressure values, as ...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章,评审

    doi:10.1186/s12938-019-0636-3

    authors: Jędzierowska M,Koprowski R

    更新日期:2019-02-13 00:00:00

  • Physical mechanism and modeling of heat generation and transfer in magnetic fluid hyperthermia through Néelian and Brownian relaxation: a review.

    abstract::Current clinically accepted technologies for cancer treatment still have limitations which lead to the exploration of new therapeutic methods. Since the past few decades, the hyperthermia treatment has attracted the attention of investigators owing to its strong biological rationales in applying hyperthermia as a canc...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章,评审

    doi:10.1186/s12938-017-0327-x

    authors: Suriyanto,Ng EY,Kumar SD

    更新日期:2017-03-23 00:00:00

  • Development and mechanical testing of a short intramedullary nail for fixation of femoral rotational osteotomy in cerebral palsy patients.

    abstract:BACKGROUND:Rotational osteotomy is frequently indicated to correct excessive femoral anteversion in cerebral palsy patients. Angled blade plate is the standard fixation device used when performed in the proximal femur, but extensile exposure is required for plate accommodation. The authors developed a short locked intr...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-10-57

    authors: Pagnano RG,Okubo R,Volpon JB

    更新日期:2011-06-28 00:00:00

  • Correction to: Effects of astrocyte on neuronal outgrowth in a layered 3D structure.

    abstract::It was highlighted that the original article [1] contained an error in the Acknowledgments section. ...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章,已发布勘误

    doi:10.1186/s12938-019-0707-5

    authors: Fang A,Li D,Hao Z,Wang L,Pan B,Gao L,Qu X,He J

    更新日期:2019-08-08 00:00:00

  • In vitro evaluation of Panax notoginseng Rg1 released from collagen/chitosan-gelatin microsphere scaffolds for angiogenesis.

    abstract:BACKGROUND:The emergence of skin substitutes provides a new approach for the treatment of wound repair and healing. The consistent and steady release of angiogenic factors is an important factor in the promotion of angiogenesis in skin substitutes, which usually lack, yet need, a vascular network. METHODS:In this stud...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-12-134

    authors: Zheng Y,Feng Z,You C,Jin Y,Hu X,Wang X,Han C

    更新日期:2013-12-31 00:00:00

  • Translational-circular scanning for magneto-acoustic tomography with current injection.

    abstract:BACKGROUND:Magneto-acoustic tomography with current injection involves using electrical impedance imaging technology. To explore the potential applications in imaging biological tissue and enhance image quality, a new scan mode for the transducer is proposed that is based on translational and circular scanning to recor...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-016-0125-x

    authors: Wang S,Ma R,Zhang S,Yin T,Liu Z

    更新日期:2016-01-27 00:00:00

  • A specialized motion capture system for real-time analysis of mandibular movements using infrared cameras.

    abstract:BACKGROUND:In the last years, several methods and devices have been proposed to record the human mandibular movements, since they provide quantitative parameters that support the diagnosis and treatment of temporomandibular disorders. The techniques currently employed suffer from a number of drawbacks including high pr...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-12-17

    authors: Furtado DA,Pereira AA,Andrade Ade O,Bellomo DP Jr,da Silva MR

    更新日期:2013-02-22 00:00:00

  • Hemodynamic effects of perfusion level of peripheral ECMO on cardiovascular system.

    abstract:BACKGROUND:Peripheral ECMO is an effective cardiopulmonary support in clinical. The perfusion level could directly influence the performances and complications. However, there are few studies on the effects of the perfusion level on hemodynamics of peripheral ECMO. METHODS:The geometric model of cardiovascular system ...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-018-0493-5

    authors: Gu K,Zhang Z,Gao B,Chang Y,Wan F

    更新日期:2018-05-09 00:00:00

  • Evaluation of flow changes after telescopic stenting of a giant fusiform aneurysm of the vertebrobasilar junction.

    abstract:BACKGROUND:The use of flow-diverters for non-saccular cerebral posterior circulation aneurysms requires complex deployment techniques and is associated with high mortality and morbidity. Therefore, further studies are required to clarify the effect of stenting on post-treatment hemodynamics in such aneurysms. In this s...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-019-0699-1

    authors: Sindeev S,Kirschke JS,Prothmann S,Frolov S,Liepsch D,Berg P,Zimmer C,Friedrich B

    更新日期:2019-07-24 00:00:00

  • Effect of pressure and padding on motion artifact of textile electrodes.

    abstract:BACKGROUND:With the aging population and rising healthcare costs, wearable monitoring is gaining importance. The motion artifact affecting dry electrodes is one of the main challenges preventing the widespread use of wearable monitoring systems. In this paper we investigate the motion artifact and ways of making a text...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-12-26

    authors: Cömert A,Honkala M,Hyttinen J

    更新日期:2013-04-08 00:00:00

  • Designing and testing scene enhancement algorithms for patients with retina degenerative disorders.

    abstract:BACKGROUND:Retina degenerative disorders represent the primary cause of blindness in UK and in the developed world. In particular, Age Related Macular Degeneration (AMD) and Retina Pigmentosa (RP) diseases are of interest to this study. We have therefore created new image processing algorithms for enhancing the visual ...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-9-27

    authors: Al-Atabany WI,Memon MA,Downes SM,Degenaar PA

    更新日期:2010-06-18 00:00:00

  • S-EMG signal compression based on domain transformation and spectral shape dynamic bit allocation.

    abstract:BACKGROUND:Surface electromyographic (S-EMG) signal processing has been emerging in the past few years due to its non-invasive assessment of muscle function and structure and because of the fast growing rate of digital technology which brings about new solutions and applications. Factors such as sampling rate, quantiza...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-13-22

    authors: Trabuco MH,Costa MV,Nascimento FA

    更新日期:2014-02-27 00:00:00

  • Dynamic behavior of suture-anastomosed arteries and implications to vascular surgery operations.

    abstract:BACKGROUND:Routine vascular surgery operations involve stitching of disconnected human arteries with themselves or with artificial grafts (arterial anastomosis). This study aims to extend current knowledge and provide better-substantiated understanding of the mechanics of end-to-end anastomosis through the development ...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-14-1

    authors: Roussis PC,Giannakopoulos AE,Charalambous HP,Demetriou DC,Georghiou GP

    更新日期:2015-01-06 00:00:00