The approximate entropy of the electromyographic signals of tremor correlates with the osmotic fragility of human erythrocytes.

Abstract:

BACKGROUND:The main problem of tremor is the damage caused to the quality of the life of patients, especially those at more advanced ages. There is not a consensus yet about the origins of this disorder, but it can be examined in the correlations between the biological signs of aging and the tremor characteristics. METHODS:This work sought correlations between the osmotic fragility of erythrocytes and features extracted from electromyographic (EMG) activity resulting from physiological tremor in healthy patients (N = 44) at different ages (24-87 years). The osmotic fragility was spectrophotometrically evaluated by the dependence of hemolysis, provided by the absorbance in 540 nm (A54o), on the concentration of NaCl. The data were adjusted to curves of sigmoidal regression and characterized by the half transition point (H50), amplitude of lysis transition (dx) and values of A540 in the curve regions that characterize the presence of lysed (A1) and preserved erythrocytes (A2). The approximate entropy was estimated from EMG signals detected from the extensor carpi ulnaris muscle during the movement of the hand of subjects holding up a laser pen towards an Archimedes spiral, fixed in a whiteboard. The evaluations were carried out with the laser pen at rest, at the center of the spiral, and in movement from the center to the outside and from outside to the center. The correlations among the parameters of osmotic fragility, tremor and age were tested. RESULTS:Negative correlations with age were found for A1 and dx. With the hand at rest, a positive correlation with H50 was found for the approximate entropy. Negative correlations with H50 were found for the entropy with the hand in movement, as from the center to the outside or from the outside to the center of the spiral. CONCLUSION:In healthy individuals, the increase in the erythrocyte osmotic fragility was associated with a decrease in the approximate entropy for rest tremor and with an increase of the entropy for movement tremor. This suggests that the neuromuscular degeneration associated with tremor entails also the mechanisms involved in the breakdown of structural homeostasis of the erythrocyte membrane.

journal_name

Biomed Eng Online

authors

Mansur PH,Cury LK,Leite JO,Pereira AA,Penha-Silva N,Andrade AO

doi

10.1186/1475-925X-9-29

subject

Has Abstract

pub_date

2010-06-22 00:00:00

pages

29

issn

1475-925X

pii

1475-925X-9-29

journal_volume

9

pub_type

杂志文章
  • Patterned thin metal film for the lateral resolution measurement of photoacoustic tomography.

    abstract:BACKGROUND:Image quality assessment method of photoacoustic tomography has not been completely standardized yet. Due to the combined nature of photonic signal generation and ultrasonic signal transmission in biological tissue, neither optical nor ultrasonic traditional methods can be used without modification. An optic...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-11-37

    authors: Kim DH,Shin DH,Ryu SH,Song CG

    更新日期:2012-07-13 00:00:00

  • The use of chilled condensers for the recovery of perfluorocarbon liquid in an experimental model of perfluorocarbon vapour loss during neonatal partial liquid ventilation.

    abstract:BACKGROUND:Perfluorocarbon (PFC) vapour in the expired gases during partial liquid ventilation should be prevented from entering the atmosphere and recovered for potential reuse. This study aimed to determine how much PFC liquid could be recovered using a conventional humidified neonatal ventilator with chilled condens...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-6-19

    authors: Dunster KR,Davies MW,Fraser JF

    更新日期:2007-05-31 00:00:00

  • Conductivity image enhancement in MREIT using adaptively weighted spatial averaging filter.

    abstract:BACKGROUND:In magnetic resonance electrical impedance tomography (MREIT), we reconstruct conductivity images using magnetic flux density data induced by externally injected currents. Since we extract magnetic flux density data from acquired MR phase images, the amount of measurement noise increases in regions of weak M...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-13-87

    authors: Oh TI,Kim HJ,Jeong WC,Wi H,Kwon OI,Woo EJ

    更新日期:2014-06-26 00:00:00

  • Correction to: Proposal of a new conceptual gait model for patients with Parkinson's disease based on factor analysis.

    abstract::It was highlighted that the original article [1] had an omission in the Abstract. This Correction article shows the omitted sentence: "This article [1] was awarded the SIAMOC Best Methodological Paper 2018". ...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章,已发布勘误

    doi:10.1186/s12938-019-0698-2

    authors: Arcolin I,Corna S,Giardini M,Giordano A,Nardone A,Godi M

    更新日期:2019-07-23 00:00:00

  • Development and mechanical testing of a short intramedullary nail for fixation of femoral rotational osteotomy in cerebral palsy patients.

    abstract:BACKGROUND:Rotational osteotomy is frequently indicated to correct excessive femoral anteversion in cerebral palsy patients. Angled blade plate is the standard fixation device used when performed in the proximal femur, but extensile exposure is required for plate accommodation. The authors developed a short locked intr...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-10-57

    authors: Pagnano RG,Okubo R,Volpon JB

    更新日期:2011-06-28 00:00:00

  • Identification of heart rate dynamics during moderate-to-vigorous treadmill exercise.

    abstract:BACKGROUND:Heart rate can be used to prescribe exercise intensity for development and maintenance of cardiorespiratory fitness. The aim of this study was to identify the dynamics of heart rate response during moderate-to-vigorous treadmill exercise and to explore parameter dependencies with respect to time, intensity l...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-015-0112-7

    authors: Hunt KJ,Fankhauser SE,Saengsuwan J

    更新日期:2015-12-21 00:00:00

  • Neonatal non-contact respiratory monitoring based on real-time infrared thermography.

    abstract:BACKGROUND:Monitoring of vital parameters is an important topic in neonatal daily care. Progress in computational intelligence and medical sensors has facilitated the development of smart bedside monitors that can integrate multiple parameters into a single monitoring system. This paper describes non-contact monitoring...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-10-93

    authors: Abbas AK,Heimann K,Jergus K,Orlikowsky T,Leonhardt S

    更新日期:2011-10-20 00:00:00

  • A portable system with sample rate of 250 Hz for characterization of knee and hip angles in the sagittal plane during gait.

    abstract:BACKGROUND:Gait analysis and research have been developed to obtain characteristics of movement patterns of people while walking. However, traditional measuring systems present different drawbacks that reduce their use and application. Among those drawbacks one can find: high price, low sampling frequency and limiting ...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-13-34

    authors: Martínez-Solís F,Claudio-Sánchez A,Rodríguez-Lelis JM,Vergara-Limon S,Olivares-Peregrino V,Vargas-Treviño M

    更新日期:2014-03-31 00:00:00

  • Mathematical modelling of the action potential of human embryonic stem cell derived cardiomyocytes.

    abstract:BACKGROUND:Human embryonic stem cell derived cardiomyocytes (hESC-CMs) hold high potential for basic and applied cardiovascular research. The development of a reliable simulation platform able to mimic the functional properties of hESC-CMs would be of considerable value to perform preliminary test complementing in vitr...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-11-61

    authors: Paci M,Sartiani L,Del Lungo M,Jaconi M,Mugelli A,Cerbai E,Severi S

    更新日期:2012-08-28 00:00:00

  • Modeling and classification of gait patterns between anterior cruciate ligament deficient and intact knees based on phase space reconstruction, Euclidean distance and neural networks.

    abstract:BACKGROUND:The anterior cruciate ligament (ACL) plays an important role in stabilizing translation and rotation of the tibia relative to the femur. ACL injury alters knee kinematics and usually links to the alternation of gait patterns. The aim of this study is to develop a new method to distinguish between gait patter...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-018-0594-1

    authors: Wu W,Zeng W,Ma L,Yuan C,Zhang Y

    更新日期:2018-11-01 00:00:00

  • In vivo long-term investigation of tumor bearing mKate2 by an in-house fluorescence molecular imaging system.

    abstract:BACKGROUND:Optical imaging is one of the most common, low-cost imaging tools used for investigating the tumor biological behavior in vivo. This study explores the feasibility and sensitivity of a near infrared fluorescent protein mKate2 for a long-term non-invasive tumor imaging in BALB/c nude mice, by using a low-powe...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-018-0615-0

    authors: Zhou K,Ding Y,Vuletic I,Tian Y,Li J,Liu J,Huang Y,Sun H,Li C,Ren Q,Lu Y

    更新日期:2018-12-29 00:00:00

  • Study of probe-sample distance for biomedical spectra measurement.

    abstract:BACKGROUND:Fiber-based optical spectroscopy has been widely used for biomedical applications. However, the effect of probe-sample distance on the collection efficiency has not been well investigated. METHOD:In this paper, we presented a theoretical model to maximize the illumination and collection efficiency in design...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-10-95

    authors: Wang B,Fan S,Li L,Wang C

    更新日期:2011-11-02 00:00:00

  • Automatic lumen segmentation in IVOCT images using binary morphological reconstruction.

    abstract:BACKGROUND:Atherosclerosis causes millions of deaths, annually yielding billions in expenses round the world. Intravascular Optical Coherence Tomography (IVOCT) is a medical imaging modality, which displays high resolution images of coronary cross-section. Nonetheless, quantitative information can only be obtained with...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-12-78

    authors: Moraes MC,Cardenas DA,Furuie SS

    更新日期:2013-08-09 00:00:00

  • Three-dimensional dominant frequency mapping using autoregressive spectral analysis of atrial electrograms of patients in persistent atrial fibrillation.

    abstract:BACKGROUND:Areas with high frequency activity within the atrium are thought to be 'drivers' of the rhythm in patients with atrial fibrillation (AF) and ablation of these areas seems to be an effective therapy in eliminating DF gradient and restoring sinus rhythm. Clinical groups have applied the traditional FFT-based a...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-016-0143-8

    authors: Salinet JL,Masca N,Stafford PJ,Ng GA,Schlindwein FS

    更新日期:2016-03-08 00:00:00

  • In vivo myograph measurement of muscle contraction at optimal length.

    abstract:BACKGROUND:Current devices for measuring muscle contraction in vivo have limited accuracy in establishing and re-establishing the optimum muscle length. They are variable in the reproducibility to determine the muscle contraction at this length, and often do not maintain precise conditions during the examination. Conse...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-6-1

    authors: Rahe-Meyer N,Weilbach C,Karst M,Pawlak M,Ahmed A,Piepenbrock S,Winterhalter M

    更新日期:2007-01-02 00:00:00

  • Effects of 8-week swimming training on carotid arterial stiffness and hemodynamics in young overweight adults.

    abstract:BACKGROUND:Exercise has been found to either reduce or increase arterial stiffness. Land-based exercise modalities have been documented as effective physical therapies to decrease arterial stiffness. However, these land-based exercise modalities may not be suitable for overweight individuals, in terms of risks of joint...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-016-0274-y

    authors: Yuan WX,Liu HB,Gao FS,Wang YX,Qin KR

    更新日期:2016-12-28 00:00:00

  • Dynamic behavior of suture-anastomosed arteries and implications to vascular surgery operations.

    abstract:BACKGROUND:Routine vascular surgery operations involve stitching of disconnected human arteries with themselves or with artificial grafts (arterial anastomosis). This study aims to extend current knowledge and provide better-substantiated understanding of the mechanics of end-to-end anastomosis through the development ...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-14-1

    authors: Roussis PC,Giannakopoulos AE,Charalambous HP,Demetriou DC,Georghiou GP

    更新日期:2015-01-06 00:00:00

  • An artifacts removal post-processing for epiphyseal region-of-interest (EROI) localization in automated bone age assessment (BAA).

    abstract:BACKGROUND:Segmentation is the most crucial part in the computer-aided bone age assessment. A well-known type of segmentation performed in the system is adaptive segmentation. While providing better result than global thresholding method, the adaptive segmentation produces a lot of unwanted noise that could affect the ...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-10-87

    authors: Chai HY,Wee LK,Swee TT,Salleh ShH,Chea LY

    更新日期:2011-09-28 00:00:00

  • 16-Channel biphasic current-mode programmable charge balanced neural stimulation.

    abstract:BACKGROUND:Neural stimulation is an important method used to activate or inhibit action potentials of the neuronal anatomical targets found in the brain, central nerve and peripheral nerve. The neural stimulator system produces biphasic pulses that deliver balanced charge into tissue from single or multichannel electro...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-017-0385-0

    authors: Li X,Zhong S,Morizio J

    更新日期:2017-08-14 00:00:00

  • Performance evaluation of a motor-imagery-based EEG-Brain computer interface using a combined cue with heterogeneous training data in BCI-Naive subjects.

    abstract:BACKGROUND:The subjects in EEG-Brain computer interface (BCI) system experience difficulties when attempting to obtain the consistent performance of the actual movement by motor imagery alone. It is necessary to find the optimal conditions and stimuli combinations that affect the performance factors of the EEG-BCI syst...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-10-91

    authors: Choi D,Ryu Y,Lee Y,Lee M

    更新日期:2011-10-12 00:00:00

  • 3-Dimensional printing in rehabilitation: feasibility of printing an upper extremity gross motor function assessment tool.

    abstract:BACKGROUND:Use of standardized and scientifically sound outcome measures is encouraged in clinical practice and research. With the development of newer rehabilitation therapies, we need technology-supported upper extremity outcome measures that are easily accessible, reliable and valid. 3-Dimensional printing (3D-print...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-020-00839-3

    authors: Kapadia N,Myers M,Musselman K,Wang RH,Yurkewich A,Popovic MR

    更新日期:2021-01-05 00:00:00

  • Influence of head models on EEG simulations and inverse source localizations.

    abstract:BACKGROUND:The structure of the anatomical surfaces, e.g., CSF and gray and white matter, could severely influence the flow of volume currents in a head model. This, in turn, will also influence the scalp potentials and the inverse source localizations. This was examined in detail with four different human head models....

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-5-10

    authors: Ramon C,Schimpf PH,Haueisen J

    更新日期:2006-02-08 00:00:00

  • Respiratory sinus arrhythmia reactivity of internet addiction abusers in negative and positive emotional states using film clips stimulation.

    abstract:BACKGROUND AND AIMS:People with internet addiction (IA) suffer from mental, physical, social, and occupational problems. IA includes psychological and physiological syndromes, and among the syndromes, emotion was suggested important mental and physiological expressions of IA. However, few physiologically emotional char...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-016-0201-2

    authors: Hsieh DL,Hsiao TC

    更新日期:2016-07-04 00:00:00

  • Developing functional workspace for the movement of trunk circumduction in healthy young subjects: a reliability study.

    abstract:BACKGROUND:The lumbar range of motion has traditionally been used to assess disability in patients with low back disorders. Controversy exists about how movement ranges in static positions or in a single straight plane is related to the functional status of the patients. The trunk circumduction, as the result of neurom...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-12-4

    authors: Cheng SC,Hsu CH,Ting YT,Kuo LC,Lin RM,Su FC

    更新日期:2013-01-11 00:00:00

  • Monitoring and analysis of dynamic growth of human embryonic stem cells: comparison of automated instrumentation and conventional culturing methods.

    abstract:BACKGROUND:Human embryonic stem cells (hESCs) are a potential source of cells for use in regenerative medicine. Automation of culturing, monitoring and analysis is crucial for fast and reliable optimization of hESC culturing methods. Continuous monitoring of living cell cultures can reveal more information and is faste...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-6-11

    authors: Narkilahti S,Rajala K,Pihlajamäki H,Suuronen R,Hovatta O,Skottman H

    更新日期:2007-04-12 00:00:00

  • Automatic method of analysis and measurement of additional parameters of corneal deformation in the Corvis tonometer.

    abstract:INTRODUCTION:The method for measuring intraocular pressure using the Corvis tonometer provides a sequence of images of corneal deformation. Deformations of the cornea are recorded using the ultra-high-speed Scheimpflug camera. This paper presents a new and reproducible method of analysis of corneal deformation images t...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-13-150

    authors: Koprowski R

    更新日期:2014-11-19 00:00:00

  • Collaborative and secure transmission of medical data applied to mobile healthcare.

    abstract:PURPOSE:We propose a collaborative and secure transmission scheme in order to safely and efficiently transmit medical data and provide telemedicine services, lighten the load on wireless access networks, and improve the quality of medical treatment such as surgery. METHODS:First, the transmission technology based on o...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-019-0674-x

    authors: Chen W,Chen Z,Cui F

    更新日期:2019-05-20 00:00:00

  • Safety assessment of near infrared light emitting diodes for diffuse optical measurements.

    abstract:BACKGROUND:Near infrared (NIR) light has been used widely to monitor important hemodynamic parameters in tissue non-invasively. Pulse oximetry, near infrared spectroscopy, and diffuse optical tomography are examples of such NIR light-based applications. These and other similar applications employ either lasers or light...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-3-9

    authors: Bozkurt A,Onaral B

    更新日期:2004-03-22 00:00:00

  • Home-based system for physical activity monitoring in patients with multiple sclerosis (Pilot study).

    abstract:BACKGROUND:Limitations in physical activity are considered as a key problem in patients with multiple sclerosis (PwMS). Contemporary methods to assess the level of physical activity in PwMS are regular clinical observation. However, these methods either rely on high recall and accurate reporting from the patients (e.g....

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-13-10

    authors: Shammas L,Zentek T,von Haaren B,Schlesinger S,Hey S,Rashid A

    更新日期:2014-02-06 00:00:00

  • Review of cognitive behavioural therapy mobile apps using a reference architecture embedded in the patient-provider relationship.

    abstract:BACKGROUND:Mobile health apps (mHealth apps) are increasing in popularity and utility for the management of many chronic diseases. Although the current reimbursement structure for mHealth apps is lagging behind the rapidly improving functionality, more clinicians will begin to recommend these apps as they prove their c...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-018-0611-4

    authors: Lan A,Lee A,Munroe K,McRae C,Kaleis L,Keshavjee K,Guergachi A

    更新日期:2018-12-17 00:00:00