Dynamic behavior of suture-anastomosed arteries and implications to vascular surgery operations.

Abstract:

BACKGROUND:Routine vascular surgery operations involve stitching of disconnected human arteries with themselves or with artificial grafts (arterial anastomosis). This study aims to extend current knowledge and provide better-substantiated understanding of the mechanics of end-to-end anastomosis through the development of an analytical model governing the dynamic behavior of the anastomotic region of two initially separated arteries. METHODS:The formulation accounts for the arterial axial-circumferential deformation coupling and suture-artery interaction. The proposed model captures the effects of the most important parameters, including the geometric and mechanical properties of artery and sutures, number of sutures, loading characteristics, longitudinal residual stresses, and suture pre-tensioning. RESULTS:Closed-form expressions are derived for the system response in terms of arterial radial displacement, anastomotic gap, suture tensile force, and embedding stress due to suture-artery contact interaction. Explicit objective functionalities are established to prevent failure at the anastomotic interface. CONCLUSIONS:The mathematical formulation reveals useful interrelations among the problem parameters, thus making the proposed model a valuable tool for the optimal selection of materials and improved functionality of the sutures. By virtue of their generality and directness of application, the findings of this study can ultimately form the basis for the development of vascular anastomosis guidelines pertaining to the prevention of post-surgery implications.

journal_name

Biomed Eng Online

authors

Roussis PC,Giannakopoulos AE,Charalambous HP,Demetriou DC,Georghiou GP

doi

10.1186/1475-925X-14-1

subject

Has Abstract

pub_date

2015-01-06 00:00:00

pages

1

issn

1475-925X

pii

1475-925X-14-1

journal_volume

14

pub_type

杂志文章
  • Study on the biomechanical responses of the loaded bone in macroscale and mesoscale by multiscale poroelastic FE analysis.

    abstract:BACKGROUND:Bone is a hierarchically structured composite material, and different hierarchical levels exhibit diverse material properties and functions. The stress and strain distribution and fluid flow in bone play an important role in the realization of mechanotransduction and bone remodeling. METHODS:To investigate ...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-019-0741-3

    authors: Yu W,Wu X,Cen H,Guo Y,Li C,Wang Y,Qin Y,Chen W

    更新日期:2019-12-23 00:00:00

  • Comparison of human uterine cervical electrical impedance measurements derived using two tetrapolar probes of different sizes.

    abstract:BACKGROUND:We sought to compare uterine cervical electrical impedance spectroscopy measurements employing two probes of different sizes, and to employ a finite element model to predict and compare the fraction of electrical current derived from subepithelial stromal tissue. METHODS:Cervical impedance was measured in 1...

    journal_title:Biomedical engineering online

    pub_type: 临床试验,杂志文章

    doi:10.1186/1475-925X-5-62

    authors: Gandhi SV,Walker DC,Brown BH,Anumba DO

    更新日期:2006-11-24 00:00:00

  • In vivo and in vitro performance of a China-made hemodialysis machine: a multi-center prospective controlled study.

    abstract:OBJECTIVE:To evaluate the in vivo and in vitro performance of a China-made dialysis machine (SWS-4000). METHODS:This was a multi-center prospective controlled study consisting of both long-term in vitro evaluations and cross-over in vivo tests in 132 patients. The China-made SWS-4000 dialysis machine was compared with...

    journal_title:Biomedical engineering online

    pub_type: 临床试验,杂志文章,多中心研究

    doi:10.1186/s12938-017-0387-y

    authors: Wang Y,Chen XM,Cai GY,Li WG,Zhang AH,Hao LR,Shi M,Wang R,Jiang HL,Luo HM,Zhang D,Sun XF

    更新日期:2017-08-02 00:00:00

  • Translational-circular scanning for magneto-acoustic tomography with current injection.

    abstract:BACKGROUND:Magneto-acoustic tomography with current injection involves using electrical impedance imaging technology. To explore the potential applications in imaging biological tissue and enhance image quality, a new scan mode for the transducer is proposed that is based on translational and circular scanning to recor...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-016-0125-x

    authors: Wang S,Ma R,Zhang S,Yin T,Liu Z

    更新日期:2016-01-27 00:00:00

  • Extremely low flow tracheal gas insufflation of helium-oxygen mixture improves gas exchange in a rabbit model of piston-type high-frequency oscillatory ventilation.

    abstract:OBJECTIVE:The purpose of this study was to show the effects of the tracheal gas insufflation (TGI) technique on gas exchange using helium-oxygen mixtures during high-frequency oscillatory ventilation (HFOV). We hypothesized that a helium-oxygen mixture delivered into the trachea using the TGI technique (0.3 L/min) woul...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-12-29

    authors: Baba A,Nakamura T,Aikawa T,Koike K

    更新日期:2013-04-08 00:00:00

  • Safety assessment of near infrared light emitting diodes for diffuse optical measurements.

    abstract:BACKGROUND:Near infrared (NIR) light has been used widely to monitor important hemodynamic parameters in tissue non-invasively. Pulse oximetry, near infrared spectroscopy, and diffuse optical tomography are examples of such NIR light-based applications. These and other similar applications employ either lasers or light...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-3-9

    authors: Bozkurt A,Onaral B

    更新日期:2004-03-22 00:00:00

  • PDE based scheme for multi-modal medical image watermarking.

    abstract:BACKGROUND:This work deals with copyright protection of digital images, an issue that needs protection of intellectual property rights. It is an important issue with a large number of medical images interchanged on the Internet every day. So, it is a challenging task to ensure the integrity of received images as well a...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-015-0101-x

    authors: Aherrahrou N,Tairi H

    更新日期:2015-11-25 00:00:00

  • Electrochemotherapy of colorectal liver metastases--an observational study of its effects on the electrocardiogram.

    abstract:BACKGROUND:Electrochemotherapy (ECT) is a combined treatment in which high voltage electroporation (EP) pulses are used to facilitate the uptake of a chemotherapeutic drug into tumor cells, thus increasing antitumor effectiveness of the drug. The effect of ECT of deep-seated tumors located close to the heart on functio...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-14-S3-S5

    authors: Mali B,Gorjup V,Edhemovic I,Brecelj E,Cemazar M,Sersa G,Strazisar B,Miklavcic D,Jarm T

    更新日期:2015-01-01 00:00:00

  • Phantom-based experimental validation of fast virtual deployment of self-expandable stents for cerebral aneurysms.

    abstract:BACKGROUND:Endovascular intervention using a stent is a mainstream treatment for cerebral aneurysms. To assess the effect of intervention strategies on aneurysm hemodynamics, we have developed a fast virtual stenting (FVS) technique to simulate stent deployment in patient-specific aneurysms. However, quantitative valid...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-016-0250-6

    authors: Zhang Q,Meng Z,Zhang Y,Yao K,Liu J,Zhang Y,Jing L,Yang X,Paliwal N,Meng H,Wang S

    更新日期:2016-12-28 00:00:00

  • Correlations between carotid plaque progression and mechanical stresses change sign over time: a patient follow up study using MRI and 3D FSI models.

    abstract:BACKGROUND:Increasing evidence suggests that mechanisms governing advanced plaque progression may be different from those for early progression and require further investigation. Serial MRI data and 3D fluid-structure interaction (FSI) models were employed to identify possible correlations between mechanical stresses a...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-12-105

    authors: Tang D,Yang C,Canton G,Wu Z,Hatsukami T,Yuan C

    更新日期:2013-10-14 00:00:00

  • Influence of model boundary conditions on blood flow patterns in a patient specific stenotic right coronary artery.

    abstract:BACKGROUND:In literature, the effect of the inflow boundary condition was investigated by examining the impact of the waveform and the shape of the spatial profile of the inlet velocity on the cardiac hemodynamics. However, not much work has been reported on comparing the effect of the different combinations of the inl...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-14-S1-S6

    authors: Liu B,Zheng J,Bach R,Tang D

    更新日期:2015-01-01 00:00:00

  • An artifacts removal post-processing for epiphyseal region-of-interest (EROI) localization in automated bone age assessment (BAA).

    abstract:BACKGROUND:Segmentation is the most crucial part in the computer-aided bone age assessment. A well-known type of segmentation performed in the system is adaptive segmentation. While providing better result than global thresholding method, the adaptive segmentation produces a lot of unwanted noise that could affect the ...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-10-87

    authors: Chai HY,Wee LK,Swee TT,Salleh ShH,Chea LY

    更新日期:2011-09-28 00:00:00

  • Growth rate and rupture rate of unruptured intracranial aneurysms: a population approach.

    abstract:BACKGROUND:Understanding aneurysm growth rate allows us to predict not only the current rupture risk, but also accumulated rupture risk in the future. However, determining growth rate of unruptured intracranial aneurysms often requires follow-up of patients for a long period of time so that significant growth can be ob...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-8-11

    authors: Jou LD,Mawad ME

    更新日期:2009-06-18 00:00:00

  • Regional differences in APD restitution can initiate wavebreak and re-entry in cardiac tissue: a computational study.

    abstract:BACKGROUND:Regional differences in action potential duration (APD) restitution in the heart favour arrhythmias, but the mechanism is not well understood. METHODS:We simulated a 150 x 150 mm 2D sheet of cardiac ventricular tissue using a simplified computational model. We investigated wavebreak and re-entry initiated b...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-4-54

    authors: Clayton RH,Taggart P

    更新日期:2005-09-20 00:00:00

  • Improved content aware scene retargeting for retinitis pigmentosa patients.

    abstract:BACKGROUND:In this paper we present a novel scene retargeting technique to reduce the visual scene while maintaining the size of the key features. The algorithm is scalable to implementation onto portable devices, and thus, has potential for augmented reality systems to provide visual support for those with tunnel visi...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-9-52

    authors: Al-Atabany WI,Tong T,Degenaar PA

    更新日期:2010-09-16 00:00:00

  • Probability mapping of scarred myocardium using texture and intensity features in CMR images.

    abstract:BACKGROUND:The myocardium exhibits heterogeneous nature due to scarring after Myocardial Infarction (MI). In Cardiac Magnetic Resonance (CMR) imaging, Late Gadolinium (LG) contrast agent enhances the intensity of scarred area in the myocardium. METHODS:In this paper, we propose a probability mapping technique using Te...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-12-91

    authors: Kotu LP,Engan K,Skretting K,Måløy F,Orn S,Woie L,Eftestøl T

    更新日期:2013-09-22 00:00:00

  • Challenges, issues and trends in fall detection systems.

    abstract::Since falls are a major public health problem among older people, the number of systems aimed at detecting them has increased dramatically over recent years. This work presents an extensive literature review of fall detection systems, including comparisons among various kinds of studies. It aims to serve as a referenc...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章,评审

    doi:10.1186/1475-925X-12-66

    authors: Igual R,Medrano C,Plaza I

    更新日期:2013-07-06 00:00:00

  • A portable system with sample rate of 250 Hz for characterization of knee and hip angles in the sagittal plane during gait.

    abstract:BACKGROUND:Gait analysis and research have been developed to obtain characteristics of movement patterns of people while walking. However, traditional measuring systems present different drawbacks that reduce their use and application. Among those drawbacks one can find: high price, low sampling frequency and limiting ...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-13-34

    authors: Martínez-Solís F,Claudio-Sánchez A,Rodríguez-Lelis JM,Vergara-Limon S,Olivares-Peregrino V,Vargas-Treviño M

    更新日期:2014-03-31 00:00:00

  • Evaluation of three force-position hybrid control methods for a robot-based biological joint-testing system.

    abstract:BACKGROUND:Robot-based joint-testing systems (RJTS) can be used to perform unconstrained laxity tests, measuring the stiffness of a degree of freedom (DOF) of the joint at a fixed flexion angle while allowing the other DOFs unconstrained movement. Previous studies using the force-position hybrid (FPH) control method pr...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-016-0195-9

    authors: Hsieh HJ,Hu CC,Lu TW,Lu HL,Kuo MY,Kuo CC,Hsu HC

    更新日期:2016-06-07 00:00:00

  • A high-resolution binocular video-oculography system: assessment of pupillary light reflex and detection of an early incomplete blink and an upward eye movement.

    abstract:BACKGROUND:The pupillary light reflex characterizes the direct and consensual response of the eye to the perceived brightness of a stimulus. It has been used as indicator of both neurological and optic nerve pathologies. As with other eye reflexes, this reflex constitutes an almost instantaneous movement and is linked ...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-015-0016-6

    authors: Espinosa J,Roig AB,Pérez J,Mas D

    更新日期:2015-03-13 00:00:00

  • Low-dose CT reconstruction via L1 dictionary learning regularization using iteratively reweighted least-squares.

    abstract:BACKGROUND:In order to reduce the radiation dose of CT (computed tomography), compressed sensing theory has been a hot topic since it provides the possibility of a high quality recovery from the sparse sampling data. Recently, the algorithm based on DL (dictionary learning) was developed to deal with the sparse CT reco...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-016-0193-y

    authors: Zhang C,Zhang T,Li M,Peng C,Liu Z,Zheng J

    更新日期:2016-06-18 00:00:00

  • The assessment of xenogeneic bone immunotoxicity and risk management study.

    abstract:BACKGROUND:Xenogeneic bone has been widely used in a variety of clinical bone-related disease to promote bone healing and restore bone defects. However, the adverse effects of immune system limit its application in the clinic. The aim of this study was to evaluate xenogeneic bone safety of immunotoxicity and explore th...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-019-0729-z

    authors: Sun X,Liu C,Shi Y,Li C,Sun L,Hou L,Wang X

    更新日期:2019-11-14 00:00:00

  • Computer-aided analysis of micro-morphological structure of porous membranes.

    abstract:BACKGROUND:The paper presents an approach and computer-aided method of numerical evaluation of the quality of porous membranes used as scaffolds for cultivation of chondrocytes in regeneration of biological tissues. MATERIALS:The scanning electron microscope (SEM) images of 300× and 1000× magnification presenting the ...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-018-0481-9

    authors: Kulikowski JL,Przytulska M,Chwojnowski A

    更新日期:2018-05-30 00:00:00

  • Characterization of the head-to-trunk orientation with handheld optical 3D apparatus based on the fringe projection technique.

    abstract:BACKGROUND:Knowing the orientation of the head is important in many fields, including medicine. Many methods and measuring systems exist, but usually they use different markers or sensors attached to the subject's head for head orientation determination. In certain applications these attachments may represent a burden ...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-12-96

    authors: Pavlovčič U,Diaci J,Možina J,Jezeršek M

    更新日期:2013-09-26 00:00:00

  • Why brain-controlled neuroprosthetics matter: mechanisms underlying electrical stimulation of muscles and nerves in rehabilitation.

    abstract::Delivering short trains of electric pulses to the muscles and nerves can elicit action potentials resulting in muscle contractions. When the stimulations are sequenced to generate functional movements, such as grasping or walking, the application is referred to as functional electrical stimulation (FES). Implications ...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章,评审

    doi:10.1186/s12938-020-00824-w

    authors: Milosevic M,Marquez-Chin C,Masani K,Hirata M,Nomura T,Popovic MR,Nakazawa K

    更新日期:2020-11-04 00:00:00

  • Automatic diagnosis of imbalanced ophthalmic images using a cost-sensitive deep convolutional neural network.

    abstract:BACKGROUND:Ocular images play an essential role in ophthalmological diagnoses. Having an imbalanced dataset is an inevitable issue in automated ocular diseases diagnosis; the scarcity of positive samples always tends to result in the misdiagnosis of severe patients during the classification task. Exploring an effective...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-017-0420-1

    authors: Jiang J,Liu X,Zhang K,Long E,Wang L,Li W,Liu L,Wang S,Zhu M,Cui J,Liu Z,Lin Z,Li X,Chen J,Cao Q,Li J,Wu X,Wang D,Wang J,Lin H

    更新日期:2017-11-21 00:00:00

  • Automatic lumen segmentation in IVOCT images using binary morphological reconstruction.

    abstract:BACKGROUND:Atherosclerosis causes millions of deaths, annually yielding billions in expenses round the world. Intravascular Optical Coherence Tomography (IVOCT) is a medical imaging modality, which displays high resolution images of coronary cross-section. Nonetheless, quantitative information can only be obtained with...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-12-78

    authors: Moraes MC,Cardenas DA,Furuie SS

    更新日期:2013-08-09 00:00:00

  • The development and application of an oncology Therapy-Related Symptom Checklist for Adults (TRSC) and Children (TRSC-C) and e-health applications.

    abstract:BACKGROUND:Studies found that treatment symptoms of concern to oncology/hematology patients were greatly under-identified in medical records. On average, 11.0 symptoms were reported of concern to patients compared to 1.5 symptoms identified in their medical records. A solution to this problem is use of an electronic sy...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-14-S2-S1

    authors: Williams AR,Williams DD,Williams PD,Alemi F,Hesham H,Donley B,Kheirbek RE

    更新日期:2015-01-01 00:00:00

  • Performance evaluation of a motor-imagery-based EEG-Brain computer interface using a combined cue with heterogeneous training data in BCI-Naive subjects.

    abstract:BACKGROUND:The subjects in EEG-Brain computer interface (BCI) system experience difficulties when attempting to obtain the consistent performance of the actual movement by motor imagery alone. It is necessary to find the optimal conditions and stimuli combinations that affect the performance factors of the EEG-BCI syst...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-10-91

    authors: Choi D,Ryu Y,Lee Y,Lee M

    更新日期:2011-10-12 00:00:00

  • Developing functional workspace for the movement of trunk circumduction in healthy young subjects: a reliability study.

    abstract:BACKGROUND:The lumbar range of motion has traditionally been used to assess disability in patients with low back disorders. Controversy exists about how movement ranges in static positions or in a single straight plane is related to the functional status of the patients. The trunk circumduction, as the result of neurom...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-12-4

    authors: Cheng SC,Hsu CH,Ting YT,Kuo LC,Lin RM,Su FC

    更新日期:2013-01-11 00:00:00