Abstract:
BACKGROUND:Routine vascular surgery operations involve stitching of disconnected human arteries with themselves or with artificial grafts (arterial anastomosis). This study aims to extend current knowledge and provide better-substantiated understanding of the mechanics of end-to-end anastomosis through the development of an analytical model governing the dynamic behavior of the anastomotic region of two initially separated arteries. METHODS:The formulation accounts for the arterial axial-circumferential deformation coupling and suture-artery interaction. The proposed model captures the effects of the most important parameters, including the geometric and mechanical properties of artery and sutures, number of sutures, loading characteristics, longitudinal residual stresses, and suture pre-tensioning. RESULTS:Closed-form expressions are derived for the system response in terms of arterial radial displacement, anastomotic gap, suture tensile force, and embedding stress due to suture-artery contact interaction. Explicit objective functionalities are established to prevent failure at the anastomotic interface. CONCLUSIONS:The mathematical formulation reveals useful interrelations among the problem parameters, thus making the proposed model a valuable tool for the optimal selection of materials and improved functionality of the sutures. By virtue of their generality and directness of application, the findings of this study can ultimately form the basis for the development of vascular anastomosis guidelines pertaining to the prevention of post-surgery implications.
journal_name
Biomed Eng Onlinejournal_title
Biomedical engineering onlineauthors
Roussis PC,Giannakopoulos AE,Charalambous HP,Demetriou DC,Georghiou GPdoi
10.1186/1475-925X-14-1subject
Has Abstractpub_date
2015-01-06 00:00:00pages
1issn
1475-925Xpii
1475-925X-14-1journal_volume
14pub_type
杂志文章abstract:BACKGROUND:Bone is a hierarchically structured composite material, and different hierarchical levels exhibit diverse material properties and functions. The stress and strain distribution and fluid flow in bone play an important role in the realization of mechanotransduction and bone remodeling. METHODS:To investigate ...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/s12938-019-0741-3
更新日期:2019-12-23 00:00:00
abstract:BACKGROUND:We sought to compare uterine cervical electrical impedance spectroscopy measurements employing two probes of different sizes, and to employ a finite element model to predict and compare the fraction of electrical current derived from subepithelial stromal tissue. METHODS:Cervical impedance was measured in 1...
journal_title:Biomedical engineering online
pub_type: 临床试验,杂志文章
doi:10.1186/1475-925X-5-62
更新日期:2006-11-24 00:00:00
abstract:OBJECTIVE:To evaluate the in vivo and in vitro performance of a China-made dialysis machine (SWS-4000). METHODS:This was a multi-center prospective controlled study consisting of both long-term in vitro evaluations and cross-over in vivo tests in 132 patients. The China-made SWS-4000 dialysis machine was compared with...
journal_title:Biomedical engineering online
pub_type: 临床试验,杂志文章,多中心研究
doi:10.1186/s12938-017-0387-y
更新日期:2017-08-02 00:00:00
abstract:BACKGROUND:Magneto-acoustic tomography with current injection involves using electrical impedance imaging technology. To explore the potential applications in imaging biological tissue and enhance image quality, a new scan mode for the transducer is proposed that is based on translational and circular scanning to recor...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/s12938-016-0125-x
更新日期:2016-01-27 00:00:00
abstract:OBJECTIVE:The purpose of this study was to show the effects of the tracheal gas insufflation (TGI) technique on gas exchange using helium-oxygen mixtures during high-frequency oscillatory ventilation (HFOV). We hypothesized that a helium-oxygen mixture delivered into the trachea using the TGI technique (0.3 L/min) woul...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/1475-925X-12-29
更新日期:2013-04-08 00:00:00
abstract:BACKGROUND:Near infrared (NIR) light has been used widely to monitor important hemodynamic parameters in tissue non-invasively. Pulse oximetry, near infrared spectroscopy, and diffuse optical tomography are examples of such NIR light-based applications. These and other similar applications employ either lasers or light...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/1475-925X-3-9
更新日期:2004-03-22 00:00:00
abstract:BACKGROUND:This work deals with copyright protection of digital images, an issue that needs protection of intellectual property rights. It is an important issue with a large number of medical images interchanged on the Internet every day. So, it is a challenging task to ensure the integrity of received images as well a...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/s12938-015-0101-x
更新日期:2015-11-25 00:00:00
abstract:BACKGROUND:Electrochemotherapy (ECT) is a combined treatment in which high voltage electroporation (EP) pulses are used to facilitate the uptake of a chemotherapeutic drug into tumor cells, thus increasing antitumor effectiveness of the drug. The effect of ECT of deep-seated tumors located close to the heart on functio...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/1475-925X-14-S3-S5
更新日期:2015-01-01 00:00:00
abstract:BACKGROUND:Endovascular intervention using a stent is a mainstream treatment for cerebral aneurysms. To assess the effect of intervention strategies on aneurysm hemodynamics, we have developed a fast virtual stenting (FVS) technique to simulate stent deployment in patient-specific aneurysms. However, quantitative valid...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/s12938-016-0250-6
更新日期:2016-12-28 00:00:00
abstract:BACKGROUND:Increasing evidence suggests that mechanisms governing advanced plaque progression may be different from those for early progression and require further investigation. Serial MRI data and 3D fluid-structure interaction (FSI) models were employed to identify possible correlations between mechanical stresses a...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/1475-925X-12-105
更新日期:2013-10-14 00:00:00
abstract:BACKGROUND:In literature, the effect of the inflow boundary condition was investigated by examining the impact of the waveform and the shape of the spatial profile of the inlet velocity on the cardiac hemodynamics. However, not much work has been reported on comparing the effect of the different combinations of the inl...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/1475-925X-14-S1-S6
更新日期:2015-01-01 00:00:00
abstract:BACKGROUND:Segmentation is the most crucial part in the computer-aided bone age assessment. A well-known type of segmentation performed in the system is adaptive segmentation. While providing better result than global thresholding method, the adaptive segmentation produces a lot of unwanted noise that could affect the ...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/1475-925X-10-87
更新日期:2011-09-28 00:00:00
abstract:BACKGROUND:Understanding aneurysm growth rate allows us to predict not only the current rupture risk, but also accumulated rupture risk in the future. However, determining growth rate of unruptured intracranial aneurysms often requires follow-up of patients for a long period of time so that significant growth can be ob...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/1475-925X-8-11
更新日期:2009-06-18 00:00:00
abstract:BACKGROUND:Regional differences in action potential duration (APD) restitution in the heart favour arrhythmias, but the mechanism is not well understood. METHODS:We simulated a 150 x 150 mm 2D sheet of cardiac ventricular tissue using a simplified computational model. We investigated wavebreak and re-entry initiated b...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/1475-925X-4-54
更新日期:2005-09-20 00:00:00
abstract:BACKGROUND:In this paper we present a novel scene retargeting technique to reduce the visual scene while maintaining the size of the key features. The algorithm is scalable to implementation onto portable devices, and thus, has potential for augmented reality systems to provide visual support for those with tunnel visi...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/1475-925X-9-52
更新日期:2010-09-16 00:00:00
abstract:BACKGROUND:The myocardium exhibits heterogeneous nature due to scarring after Myocardial Infarction (MI). In Cardiac Magnetic Resonance (CMR) imaging, Late Gadolinium (LG) contrast agent enhances the intensity of scarred area in the myocardium. METHODS:In this paper, we propose a probability mapping technique using Te...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/1475-925X-12-91
更新日期:2013-09-22 00:00:00
abstract::Since falls are a major public health problem among older people, the number of systems aimed at detecting them has increased dramatically over recent years. This work presents an extensive literature review of fall detection systems, including comparisons among various kinds of studies. It aims to serve as a referenc...
journal_title:Biomedical engineering online
pub_type: 杂志文章,评审
doi:10.1186/1475-925X-12-66
更新日期:2013-07-06 00:00:00
abstract:BACKGROUND:Gait analysis and research have been developed to obtain characteristics of movement patterns of people while walking. However, traditional measuring systems present different drawbacks that reduce their use and application. Among those drawbacks one can find: high price, low sampling frequency and limiting ...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/1475-925X-13-34
更新日期:2014-03-31 00:00:00
abstract:BACKGROUND:Robot-based joint-testing systems (RJTS) can be used to perform unconstrained laxity tests, measuring the stiffness of a degree of freedom (DOF) of the joint at a fixed flexion angle while allowing the other DOFs unconstrained movement. Previous studies using the force-position hybrid (FPH) control method pr...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/s12938-016-0195-9
更新日期:2016-06-07 00:00:00
abstract:BACKGROUND:The pupillary light reflex characterizes the direct and consensual response of the eye to the perceived brightness of a stimulus. It has been used as indicator of both neurological and optic nerve pathologies. As with other eye reflexes, this reflex constitutes an almost instantaneous movement and is linked ...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/s12938-015-0016-6
更新日期:2015-03-13 00:00:00
abstract:BACKGROUND:In order to reduce the radiation dose of CT (computed tomography), compressed sensing theory has been a hot topic since it provides the possibility of a high quality recovery from the sparse sampling data. Recently, the algorithm based on DL (dictionary learning) was developed to deal with the sparse CT reco...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/s12938-016-0193-y
更新日期:2016-06-18 00:00:00
abstract:BACKGROUND:Xenogeneic bone has been widely used in a variety of clinical bone-related disease to promote bone healing and restore bone defects. However, the adverse effects of immune system limit its application in the clinic. The aim of this study was to evaluate xenogeneic bone safety of immunotoxicity and explore th...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/s12938-019-0729-z
更新日期:2019-11-14 00:00:00
abstract:BACKGROUND:The paper presents an approach and computer-aided method of numerical evaluation of the quality of porous membranes used as scaffolds for cultivation of chondrocytes in regeneration of biological tissues. MATERIALS:The scanning electron microscope (SEM) images of 300× and 1000× magnification presenting the ...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/s12938-018-0481-9
更新日期:2018-05-30 00:00:00
abstract:BACKGROUND:Knowing the orientation of the head is important in many fields, including medicine. Many methods and measuring systems exist, but usually they use different markers or sensors attached to the subject's head for head orientation determination. In certain applications these attachments may represent a burden ...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/1475-925X-12-96
更新日期:2013-09-26 00:00:00
abstract::Delivering short trains of electric pulses to the muscles and nerves can elicit action potentials resulting in muscle contractions. When the stimulations are sequenced to generate functional movements, such as grasping or walking, the application is referred to as functional electrical stimulation (FES). Implications ...
journal_title:Biomedical engineering online
pub_type: 杂志文章,评审
doi:10.1186/s12938-020-00824-w
更新日期:2020-11-04 00:00:00
abstract:BACKGROUND:Ocular images play an essential role in ophthalmological diagnoses. Having an imbalanced dataset is an inevitable issue in automated ocular diseases diagnosis; the scarcity of positive samples always tends to result in the misdiagnosis of severe patients during the classification task. Exploring an effective...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/s12938-017-0420-1
更新日期:2017-11-21 00:00:00
abstract:BACKGROUND:Atherosclerosis causes millions of deaths, annually yielding billions in expenses round the world. Intravascular Optical Coherence Tomography (IVOCT) is a medical imaging modality, which displays high resolution images of coronary cross-section. Nonetheless, quantitative information can only be obtained with...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/1475-925X-12-78
更新日期:2013-08-09 00:00:00
abstract:BACKGROUND:Studies found that treatment symptoms of concern to oncology/hematology patients were greatly under-identified in medical records. On average, 11.0 symptoms were reported of concern to patients compared to 1.5 symptoms identified in their medical records. A solution to this problem is use of an electronic sy...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/1475-925X-14-S2-S1
更新日期:2015-01-01 00:00:00
abstract:BACKGROUND:The subjects in EEG-Brain computer interface (BCI) system experience difficulties when attempting to obtain the consistent performance of the actual movement by motor imagery alone. It is necessary to find the optimal conditions and stimuli combinations that affect the performance factors of the EEG-BCI syst...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/1475-925X-10-91
更新日期:2011-10-12 00:00:00
abstract:BACKGROUND:The lumbar range of motion has traditionally been used to assess disability in patients with low back disorders. Controversy exists about how movement ranges in static positions or in a single straight plane is related to the functional status of the patients. The trunk circumduction, as the result of neurom...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/1475-925X-12-4
更新日期:2013-01-11 00:00:00