Evaluation of three force-position hybrid control methods for a robot-based biological joint-testing system.

Abstract:

BACKGROUND:Robot-based joint-testing systems (RJTS) can be used to perform unconstrained laxity tests, measuring the stiffness of a degree of freedom (DOF) of the joint at a fixed flexion angle while allowing the other DOFs unconstrained movement. Previous studies using the force-position hybrid (FPH) control method proposed by Fujie et al. (J Biomech Eng 115(3):211-7, 1993) focused on anterior/posterior tests. Its convergence and applicability on other clinically relevant DOFs such as valgus/varus have not been demonstrated. The current s1tudy aimed to develop a 6-DOF RJTS using an industrial robot, to propose two new force-position hybrid control methods, and to evaluate the performance of the methods and FPH in controlling the RJTS for anterior/posterior and valgus/varus laxity tests of the knee joint. METHODS:An RJTS was developed using an industrial 6-DOF robot with a 6-component load-cell attached at the effector. The performances of FPH and two new control methods, namely force-position alternate control (FPA) and force-position hybrid control with force-moment control (FPHFM), for unconstrained anterior/posterior and valgus/varus laxity tests were evaluated and compared with traditional constrained tests (CT) in terms of the number of control iterations, total time and the constraining forces and moments. RESULTS:As opposed to CT, the other three control methods successfully reduced the constraining forces and moments for both anterior/posterior and valgus/varus tests, FPHFM being the best followed in order by FPA and FPH. FPHFM had root-mean-squared constraining forces and moments of less than 2.2 N and 0.09 Nm, respectively at 0° flexion, and 2.3 N and 0.14 Nm at 30° flexion. The corresponding values for FPH were 8.5 N and 0.33 Nm, and 11.5 N and 0.45 Nm, respectively. Given the same control parameters including the compliance matrix, FPHFM and FPA reduced the constraining loads of FPH at the expense of additional control iterations, and thus increased total time, FPA taking about 10 % longer than FPHFM. CONCLUSIONS:The FPHFM would be the best choice among the methods considered when longer total time is acceptable in the intended clinical applications. The current results will be useful for selecting a force-position hybrid control method for unconstrained laxity tests using an RJTS.

journal_name

Biomed Eng Online

authors

Hsieh HJ,Hu CC,Lu TW,Lu HL,Kuo MY,Kuo CC,Hsu HC

doi

10.1186/s12938-016-0195-9

subject

Has Abstract

pub_date

2016-06-07 00:00:00

pages

62

issue

1

issn

1475-925X

pii

10.1186/s12938-016-0195-9

journal_volume

15

pub_type

杂志文章
  • Regional differences in APD restitution can initiate wavebreak and re-entry in cardiac tissue: a computational study.

    abstract:BACKGROUND:Regional differences in action potential duration (APD) restitution in the heart favour arrhythmias, but the mechanism is not well understood. METHODS:We simulated a 150 x 150 mm 2D sheet of cardiac ventricular tissue using a simplified computational model. We investigated wavebreak and re-entry initiated b...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-4-54

    authors: Clayton RH,Taggart P

    更新日期:2005-09-20 00:00:00

  • Reviewing the connection between speech and obstructive sleep apnea.

    abstract:BACKGROUND:Sleep apnea (OSA) is a common sleep disorder characterized by recurring breathing pauses during sleep caused by a blockage of the upper airway (UA). The altered UA structure or function in OSA speakers has led to hypothesize the automatic analysis of speech for OSA assessment. In this paper we critically rev...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-016-0138-5

    authors: Espinoza-Cuadros F,Fernández-Pozo R,Toledano DT,Alcázar-Ramírez JD,López-Gonzalo E,Hernández-Gómez LA

    更新日期:2016-02-20 00:00:00

  • An injection and mixing element for delivery and monitoring of inhaled nitric oxide.

    abstract:BACKGROUND:Inhaled nitric oxide (NO) is a selective pulmonary vasodilator used primarily in the critical care setting for patients concurrently supported by invasive or noninvasive positive pressure ventilation. NO delivery devices interface with ventilator breathing circuits to inject NO in proportion with the flow of...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-016-0227-5

    authors: Martin AR,Jackson C,Fromont S,Pont C,Katz IM,Caillobotte G

    更新日期:2016-08-30 00:00:00

  • Automatic QRS complex detection using two-level convolutional neural network.

    abstract:BACKGROUND:The QRS complex is the most noticeable feature in the electrocardiogram (ECG) signal, therefore, its detection is critical for ECG signal analysis. The existing detection methods largely depend on hand-crafted manual features and parameters, which may introduce significant computational complexity, especiall...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-018-0441-4

    authors: Xiang Y,Lin Z,Meng J

    更新日期:2018-01-29 00:00:00

  • A specialized motion capture system for real-time analysis of mandibular movements using infrared cameras.

    abstract:BACKGROUND:In the last years, several methods and devices have been proposed to record the human mandibular movements, since they provide quantitative parameters that support the diagnosis and treatment of temporomandibular disorders. The techniques currently employed suffer from a number of drawbacks including high pr...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-12-17

    authors: Furtado DA,Pereira AA,Andrade Ade O,Bellomo DP Jr,da Silva MR

    更新日期:2013-02-22 00:00:00

  • Monitoring and analysis of dynamic growth of human embryonic stem cells: comparison of automated instrumentation and conventional culturing methods.

    abstract:BACKGROUND:Human embryonic stem cells (hESCs) are a potential source of cells for use in regenerative medicine. Automation of culturing, monitoring and analysis is crucial for fast and reliable optimization of hESC culturing methods. Continuous monitoring of living cell cultures can reveal more information and is faste...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-6-11

    authors: Narkilahti S,Rajala K,Pihlajamäki H,Suuronen R,Hovatta O,Skottman H

    更新日期:2007-04-12 00:00:00

  • Home-based system for physical activity monitoring in patients with multiple sclerosis (Pilot study).

    abstract:BACKGROUND:Limitations in physical activity are considered as a key problem in patients with multiple sclerosis (PwMS). Contemporary methods to assess the level of physical activity in PwMS are regular clinical observation. However, these methods either rely on high recall and accurate reporting from the patients (e.g....

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-13-10

    authors: Shammas L,Zentek T,von Haaren B,Schlesinger S,Hey S,Rashid A

    更新日期:2014-02-06 00:00:00

  • Osteoblastic differentiation and stress response of human mesenchymal stem cells exposed to alternating current electric fields.

    abstract:BACKGROUND:Electric fields are integral to many biological events, from maintaining cellular homeostasis to embryonic development to healing. The application of electric fields offers substantial therapeutic potential, while optimal dosing regimens and the underlying mechanisms responsible for the positive clinical imp...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-10-9

    authors: Hronik-Tupaj M,Rice WL,Cronin-Golomb M,Kaplan DL,Georgakoudi I

    更新日期:2011-01-26 00:00:00

  • Evolutionary optimization of classifiers and features for single-trial EEG discrimination.

    abstract:BACKGROUND:State-of-the-art signal processing methods are known to detect information in single-trial event-related EEG data, a crucial aspect in development of real-time applications such as brain computer interfaces. This paper investigates one such novel approach, evaluating how individual classifier and feature sub...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-6-32

    authors: Aberg MC,Wessberg J

    更新日期:2007-08-23 00:00:00

  • Development and mechanical testing of a short intramedullary nail for fixation of femoral rotational osteotomy in cerebral palsy patients.

    abstract:BACKGROUND:Rotational osteotomy is frequently indicated to correct excessive femoral anteversion in cerebral palsy patients. Angled blade plate is the standard fixation device used when performed in the proximal femur, but extensile exposure is required for plate accommodation. The authors developed a short locked intr...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-10-57

    authors: Pagnano RG,Okubo R,Volpon JB

    更新日期:2011-06-28 00:00:00

  • A high-resolution binocular video-oculography system: assessment of pupillary light reflex and detection of an early incomplete blink and an upward eye movement.

    abstract:BACKGROUND:The pupillary light reflex characterizes the direct and consensual response of the eye to the perceived brightness of a stimulus. It has been used as indicator of both neurological and optic nerve pathologies. As with other eye reflexes, this reflex constitutes an almost instantaneous movement and is linked ...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-015-0016-6

    authors: Espinosa J,Roig AB,Pérez J,Mas D

    更新日期:2015-03-13 00:00:00

  • Conductivity image enhancement in MREIT using adaptively weighted spatial averaging filter.

    abstract:BACKGROUND:In magnetic resonance electrical impedance tomography (MREIT), we reconstruct conductivity images using magnetic flux density data induced by externally injected currents. Since we extract magnetic flux density data from acquired MR phase images, the amount of measurement noise increases in regions of weak M...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-13-87

    authors: Oh TI,Kim HJ,Jeong WC,Wi H,Kwon OI,Woo EJ

    更新日期:2014-06-26 00:00:00

  • Collaborative and secure transmission of medical data applied to mobile healthcare.

    abstract:PURPOSE:We propose a collaborative and secure transmission scheme in order to safely and efficiently transmit medical data and provide telemedicine services, lighten the load on wireless access networks, and improve the quality of medical treatment such as surgery. METHODS:First, the transmission technology based on o...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-019-0674-x

    authors: Chen W,Chen Z,Cui F

    更新日期:2019-05-20 00:00:00

  • Motor recovery monitoring using acceleration measurements in post acute stroke patients.

    abstract:BACKGROUND:Stroke is one of the major causes of morbidity and mortality. Its recovery and treatment depends on close clinical monitoring by a clinician especially during the first few hours after the onset of stroke. Patients who do not exhibit early motor recovery post thrombolysis may benefit from more aggressive tre...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-12-33

    authors: Gubbi J,Rao AS,Fang K,Yan B,Palaniswami M

    更新日期:2013-04-16 00:00:00

  • Effect of gamma radiation and accelerated aging on the mechanical and thermal behavior of HDPE/HA nano-composites for bone tissue regeneration.

    abstract:BACKGROUND:The replacement of hard tissues demands biocompatible and sometimes bioactive materials with properties similar to those of bone. Nano-composites made of biocompatible polymers and bioactive inorganic nano particles such as HDPE/HA have attracted attention as permanent bone substitutes due to their excellent...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-12-95

    authors: Alothman OY,Almajhdi FN,Fouad H

    更新日期:2013-09-24 00:00:00

  • Study on the biomechanical responses of the loaded bone in macroscale and mesoscale by multiscale poroelastic FE analysis.

    abstract:BACKGROUND:Bone is a hierarchically structured composite material, and different hierarchical levels exhibit diverse material properties and functions. The stress and strain distribution and fluid flow in bone play an important role in the realization of mechanotransduction and bone remodeling. METHODS:To investigate ...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-019-0741-3

    authors: Yu W,Wu X,Cen H,Guo Y,Li C,Wang Y,Qin Y,Chen W

    更新日期:2019-12-23 00:00:00

  • In-vivo coronary flow profiling based on biplane angiograms: influence of geometric simplifications on the three-dimensional reconstruction and wall shear stress calculation.

    abstract:BACKGROUND:Clinical studies suggest that local wall shear stress (WSS) patterns modulate the site and the progression of atherosclerotic lesions. Computational fluid dynamics (CFD) methods based on in-vivo three-dimensional vessel reconstructions have recently been shown to provide prognostically relevant WSS data. Thi...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-5-39

    authors: Wellnhofer E,Goubergrits L,Kertzscher U,Affeld K

    更新日期:2006-06-14 00:00:00

  • Wound healing of human embryonic stem cell-derived retinal pigment epithelial cells is affected by maturation stage.

    abstract:BACKGROUND:Wound healing of retinal pigment epithelium (RPE) is a complex process that may take place in common age-related macular degeneration eye disease. The purpose of this study was to evaluate whether wounding and wound healing has an effect on Ca2+ dynamics in human embryonic stem cell (hESC)-RPEs cultured diff...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-018-0535-z

    authors: Abu Khamidakh AE,Rodriguez-Martinez A,Kaarniranta K,Kallioniemi A,Skottman H,Hyttinen J,Juuti-Uusitalo K

    更新日期:2018-07-31 00:00:00

  • Automatic diagnosis of imbalanced ophthalmic images using a cost-sensitive deep convolutional neural network.

    abstract:BACKGROUND:Ocular images play an essential role in ophthalmological diagnoses. Having an imbalanced dataset is an inevitable issue in automated ocular diseases diagnosis; the scarcity of positive samples always tends to result in the misdiagnosis of severe patients during the classification task. Exploring an effective...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-017-0420-1

    authors: Jiang J,Liu X,Zhang K,Long E,Wang L,Li W,Liu L,Wang S,Zhu M,Cui J,Liu Z,Lin Z,Li X,Chen J,Cao Q,Li J,Wu X,Wang D,Wang J,Lin H

    更新日期:2017-11-21 00:00:00

  • An inverse method to determine the mechanical properties of the iris in vivo.

    abstract:BACKGROUND:Understanding the mechanical properties of the iris can help to have an insight into the eye diseases with abnormalities of the iris morphology. Material parameters of the iris were simply calculated relying on the ex vivo experiment. However, the mechanical response of the iris in vivo is different from tha...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-13-66

    authors: Zhang K,Qian X,Mei X,Liu Z

    更新日期:2014-05-30 00:00:00

  • Respiratory sinus arrhythmia reactivity of internet addiction abusers in negative and positive emotional states using film clips stimulation.

    abstract:BACKGROUND AND AIMS:People with internet addiction (IA) suffer from mental, physical, social, and occupational problems. IA includes psychological and physiological syndromes, and among the syndromes, emotion was suggested important mental and physiological expressions of IA. However, few physiologically emotional char...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-016-0201-2

    authors: Hsieh DL,Hsiao TC

    更新日期:2016-07-04 00:00:00

  • Probability mapping of scarred myocardium using texture and intensity features in CMR images.

    abstract:BACKGROUND:The myocardium exhibits heterogeneous nature due to scarring after Myocardial Infarction (MI). In Cardiac Magnetic Resonance (CMR) imaging, Late Gadolinium (LG) contrast agent enhances the intensity of scarred area in the myocardium. METHODS:In this paper, we propose a probability mapping technique using Te...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-12-91

    authors: Kotu LP,Engan K,Skretting K,Måløy F,Orn S,Woie L,Eftestøl T

    更新日期:2013-09-22 00:00:00

  • Biomechanical investigation of dynamic hip screw and wire fixation on an unstable intertrochanteric fracture.

    abstract:BACKGROUND:Although use of a dynamic hip screw (DHS) for stable intertrochanteric hip fracture fixation has been successfully applied in fracture healing for more than 20 years, DHS fixation on unstable intertrochanteric fractures still has a high failure rate, especially in patients with osteoporosis. Although the wir...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-019-0663-0

    authors: Wu HF,Chang CH,Wang GJ,Lai KA,Chen CH

    更新日期:2019-04-24 00:00:00

  • Open source model for generating RR intervals in atrial fibrillation and beyond.

    abstract:BACKGROUND:Realistic modeling of cardiac inter-beat (RR) intervals is highly desirable for basic research in cardiac electrophysiology, clinical management of heart diseases, and developing signal processing tools for ECG analysis. METHODS:We present an open source computer model that is capable to generate realistic ...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-6-9

    authors: Lian J,Clifford GD,Müssig D,Lang V

    更新日期:2007-03-02 00:00:00

  • Infrared thermography fails to visualize stimulation-induced meridian-like structures: comment by Rixin Chen and Zhimai Lv and reply from Gerhard Litscher.

    abstract::A comment on G. Litscher: Infrared thermography fails to visualize stimulation-induced meridian-like structures. Biomed. Eng. OnLine 2005, 4:38 (15 June 2005), with a response by the author. ...

    journal_title:Biomedical engineering online

    pub_type: 评论,信件

    doi:10.1186/1475-925X-10-80

    authors: Chen R,Lv Z

    更新日期:2011-09-11 00:00:00

  • On the design of a DEA-based device to pot entially assist lower leg disorders: an analytical and FEM investigation accounting for nonlinearities of the leg and device deformations.

    abstract:BACKGROUND:One of the recommended treatments for disorders associated with the lower extremity venous insufficiency is the application of external mechanical compression. Compression stockings and elastic bandages are widely used for the purpose of compression therapy and are usually designed to exert a specified value...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-015-0088-3

    authors: Pourazadi S,Ahmadi S,Menon C

    更新日期:2015-11-05 00:00:00

  • Identification of dental root canals and their medial line from micro-CT and cone-beam CT records.

    abstract:BACKGROUND:Shape of the dental root canal is highly patient specific. Automated identification methods of the medial line of dental root canals and the reproduction of their 3D shape can be beneficial for planning endodontic interventions as severely curved root canals or multi-rooted teeth may pose treatment challenge...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-11-81

    authors: Benyó B

    更新日期:2012-10-29 00:00:00

  • A computational model study of the influence of the anatomy of the circle of willis on cerebral hyperperfusion following carotid artery surgery.

    abstract:BACKGROUND:Cerebral hyperperfusion syndrome develops in a small subset of patients following carotid artery surgery (CAS) performed to treat severe carotid artery stenosis. This syndrome has been found to have a close correlation with cerebral hyperperfusion occurring after CAS. The purpose of this study is to investig...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-10-84

    authors: Liang F,Fukasaku K,Liu H,Takagi S

    更新日期:2011-09-23 00:00:00

  • Blood pressure waveform contour analysis for assessing peripheral resistance changes in sepsis.

    abstract:BACKGROUND:This paper proposes a methodology for helping bridge the gap between the complex waveform information frequently available in an intensive care unit and the simple, lumped values favoured for rapid clinical diagnosis and management. This methodology employs a simple waveform contour analysis approach to comp...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-018-0603-4

    authors: Davidson S,Pretty C,Balmer J,Desaive T,Chase JG

    更新日期:2018-11-20 00:00:00

  • Artery buckling affects the mechanical stress in atherosclerotic plaques.

    abstract:BACKGROUND:Tortuous arteries are often seen in patients with hypertension and atherosclerosis. While the mechanical stress in atherosclerotic plaque under lumen pressure has been studied extensively, the mechanical stability of atherosclerotic arteries and subsequent effect on the plaque stress remain unknown. To this ...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-14-S1-S4

    authors: Sanyal A,Han HC

    更新日期:2015-01-01 00:00:00