Osteoblastic differentiation and stress response of human mesenchymal stem cells exposed to alternating current electric fields.

Abstract:

BACKGROUND:Electric fields are integral to many biological events, from maintaining cellular homeostasis to embryonic development to healing. The application of electric fields offers substantial therapeutic potential, while optimal dosing regimens and the underlying mechanisms responsible for the positive clinical impact are poorly understood. METHODS:The purpose of this study was to track the differentiation profile and stress response of human bone marrow derived mesenchymal stem cells (hMSCs) undergoing osteogenic differentiation during exposure to a 20 mV/cm, 60 kHz electric field. Morphological and biochemical changes were imaged using endogenous two-photon excited fluorescence (TPEF) and quantitatively assessed through eccentricity calculations and extraction of the redox ratio from NADH, FAD and lipofuscin contributions. Real time reverse transcriptase-polymerase chain reactions (RT-PCR) were used to track osteogenic differentiation markers, namely alkaline phosphatase (ALP) and collagen type 1 (col1), and stress response markers, such as heat shock protein 27 (hsp27) and heat shock protein 70 (hsp70). Comparisons of collagen deposition between the stimulated hMSCs and controls were examined through second harmonic generation (SHG) imaging. RESULTS:Quantitative differences in cell morphology, as described through an eccentricity ratio, were found on days 2 and days 5 (p < 0.05) in samples exposed to the electric field. A delayed but two fold increase in ALP and col1 transcript was detected by week 2 (p < 0.05) in differentiating hMSCs exposed to an electric field in comparison to the nonstimulated controls. Upregulation in stress marker, hsp27, and type 1 collagen deposition were correlated with this response. Increases in NADH, FAD, and lipofuscin were traced in the stimulation group during the first week of field exposure with differences statistically significant on day 10 (p < 0.05). Changes in hsp27 expression correlate well with changes in lipofuscin detected in the stimulation group, suggesting a connection with oxidative stress. Both differentiation factors and electrical stimulation improved hMSC differentiation potential to bone based on calcium deposition on day 28. CONCLUSIONS:Electrical stimulation is a useful tool to improve hMSC osteogenic differentiation, while heat shock proteins may reveal underlying mechanisms, and optical non-invasive imaging may be used to monitor the induced morphological and biochemical changes.

journal_name

Biomed Eng Online

authors

Hronik-Tupaj M,Rice WL,Cronin-Golomb M,Kaplan DL,Georgakoudi I

doi

10.1186/1475-925X-10-9

subject

Has Abstract

pub_date

2011-01-26 00:00:00

pages

9

issn

1475-925X

pii

1475-925X-10-9

journal_volume

10

pub_type

杂志文章
  • Neonatal non-contact respiratory monitoring based on real-time infrared thermography.

    abstract:BACKGROUND:Monitoring of vital parameters is an important topic in neonatal daily care. Progress in computational intelligence and medical sensors has facilitated the development of smart bedside monitors that can integrate multiple parameters into a single monitoring system. This paper describes non-contact monitoring...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-10-93

    authors: Abbas AK,Heimann K,Jergus K,Orlikowsky T,Leonhardt S

    更新日期:2011-10-20 00:00:00

  • Challenges, issues and trends in fall detection systems.

    abstract::Since falls are a major public health problem among older people, the number of systems aimed at detecting them has increased dramatically over recent years. This work presents an extensive literature review of fall detection systems, including comparisons among various kinds of studies. It aims to serve as a referenc...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章,评审

    doi:10.1186/1475-925X-12-66

    authors: Igual R,Medrano C,Plaza I

    更新日期:2013-07-06 00:00:00

  • Regional differences in APD restitution can initiate wavebreak and re-entry in cardiac tissue: a computational study.

    abstract:BACKGROUND:Regional differences in action potential duration (APD) restitution in the heart favour arrhythmias, but the mechanism is not well understood. METHODS:We simulated a 150 x 150 mm 2D sheet of cardiac ventricular tissue using a simplified computational model. We investigated wavebreak and re-entry initiated b...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-4-54

    authors: Clayton RH,Taggart P

    更新日期:2005-09-20 00:00:00

  • The effect of novel nitrogen-rich plasma polymer coatings on the phenotypic profile of notochordal cells.

    abstract:BACKGROUND:The loss of the notochordal cells from the nucleus pulposus is associated with ageing and disc degeneration. However, understanding the mechanisms responsible for the loss of these cells has been hampered in part due to the difficulty of culturing and maintaining their phenotype. Furthermore, little is known...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-6-33

    authors: Mwale F,Wang HT,Petit A,Girard-Lauriault PL,Hunter CJ,Ouellet JA,Wertheimer MR,Antoniou J

    更新日期:2007-09-06 00:00:00

  • Performance assessment in brain-computer interface-based augmentative and alternative communication.

    abstract::A large number of incommensurable metrics are currently used to report the performance of brain-computer interfaces (BCI) used for augmentative and alterative communication (AAC). The lack of standard metrics precludes the comparison of different BCI-based AAC systems, hindering rapid growth and development of this te...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-12-43

    authors: Thompson DE,Blain-Moraes S,Huggins JE

    更新日期:2013-05-16 00:00:00

  • A transition-constrained discrete hidden Markov model for automatic sleep staging.

    abstract:BACKGROUND:Approximately one-third of the human lifespan is spent sleeping. To diagnose sleep problems, all-night polysomnographic (PSG) recordings including electroencephalograms (EEGs), electrooculograms (EOGs) and electromyograms (EMGs), are usually acquired from the patient and scored by a well-trained expert accor...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-11-52

    authors: Pan ST,Kuo CE,Zeng JH,Liang SF

    更新日期:2012-08-21 00:00:00

  • Development of a mathematical model to estimate intra-tumor oxygen concentrations through multi-parametric imaging.

    abstract:BACKGROUND:Tumor hypoxia is involved in every stage of solid tumor development: formation, progression, metastasis, and apoptosis. Two types of hypoxia exist in tumors-chronic hypoxia and acute hypoxia. Recent studies indicate that the regional hypoxia kinetics is closely linked to metastasis and therapeutic responses,...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-016-0235-5

    authors: Lee CW,Stantz KM

    更新日期:2016-10-12 00:00:00

  • Public access defibrillation: suppression of 16.7 Hz interference generated by the power supply of the railway systems.

    abstract:BACKGROUND:A specific problem using the public access defibrillators (PADs) arises at the railway stations. Some countries as Germany, Austria, Switzerland, Norway and Sweden are using AC railroad net power-supply system with rated 16.7 Hz frequency modulated from 15.69 Hz to 17.36 Hz. The power supply frequency contam...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-4-16

    authors: Christov II,Iliev GL

    更新日期:2005-03-15 00:00:00

  • The use of chilled condensers for the recovery of perfluorocarbon liquid in an experimental model of perfluorocarbon vapour loss during neonatal partial liquid ventilation.

    abstract:BACKGROUND:Perfluorocarbon (PFC) vapour in the expired gases during partial liquid ventilation should be prevented from entering the atmosphere and recovered for potential reuse. This study aimed to determine how much PFC liquid could be recovered using a conventional humidified neonatal ventilator with chilled condens...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-6-19

    authors: Dunster KR,Davies MW,Fraser JF

    更新日期:2007-05-31 00:00:00

  • A multivariate relationship between the kinematic and clinical parameters of knee osteoarthritis population.

    abstract:BACKGROUND:Biomechanical and clinical parameters contribute very closely to functional evaluations of the knee joint. To better understand knee osteoarthritis joint function, the association between a set of knee biomechanical data and a set of clinical parameters of an osteoarthritis population (OA) is investigated in...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-019-0676-8

    authors: Bensalma F,Mezghani N,Ouakrim Y,Fuentes A,Choinière M,Bureau NJ,Durand M,Hagemeister N

    更新日期:2019-05-15 00:00:00

  • Possibility of reconstruction of dental plaster cast from 3D digital study models.

    abstract:OBJECTIVES:To compare traditional plaster casts, digital models and 3D printed copies of dental plaster casts based on various criteria. To determine whether 3D printed copies obtained using open source system RepRap can replace traditional plaster casts in dental practice. To compare and contrast the qualities of two ...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-12-49

    authors: Kasparova M,Grafova L,Dvorak P,Dostalova T,Prochazka A,Eliasova H,Prusa J,Kakawand S

    更新日期:2013-05-31 00:00:00

  • Hemodynamic numerical simulations of the disturbance due to intracoronary flow measurements by a Doppler guide wire.

    abstract:BACKGROUND:Since hemodynamics plays a key role in the development and evolution of cardiovascular pathologies, physician's decision must be based on proper monitoring of relevant physiological flow quantities. METHODS:A numerical analysis of the error introduced by an intravascular Doppler guide wire on the peak veloc...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-016-0234-6

    authors: Chodzyński KJ,Gremmo S,Eker OF,Lalmand J,Aminian A,de Sousa DR,Boudjeltia KZ,Coussement G

    更新日期:2016-10-10 00:00:00

  • Electrochemotherapy of colorectal liver metastases--an observational study of its effects on the electrocardiogram.

    abstract:BACKGROUND:Electrochemotherapy (ECT) is a combined treatment in which high voltage electroporation (EP) pulses are used to facilitate the uptake of a chemotherapeutic drug into tumor cells, thus increasing antitumor effectiveness of the drug. The effect of ECT of deep-seated tumors located close to the heart on functio...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-14-S3-S5

    authors: Mali B,Gorjup V,Edhemovic I,Brecelj E,Cemazar M,Sersa G,Strazisar B,Miklavcic D,Jarm T

    更新日期:2015-01-01 00:00:00

  • A finite element method model to simulate laser interstitial thermo therapy in anatomical inhomogeneous regions.

    abstract:BACKGROUND:Laser Interstitial ThermoTherapy (LITT) is a well established surgical method. The use of LITT is so far limited to homogeneous tissues, e.g. the liver. One of the reasons is the limited capability of existing treatment planning models to calculate accurately the damage zone. The treatment planning in inhomo...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-4-2

    authors: Mohammed Y,Verhey JF

    更新日期:2005-01-04 00:00:00

  • Using stochastic modelling to identify unusual continuous glucose monitor measurements and behaviour, in newborn infants.

    abstract:BACKGROUND:Abnormal blood glucose (BG) concentrations have been associated with increased morbidity and mortality in both critically ill adults and infants. Furthermore, hypoglycaemia and glycaemic variability have both been independently linked to mortality in these patients. Continuous Glucose Monitoring (CGM) device...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-11-45

    authors: Signal M,Le Compte A,Harris DL,Weston PJ,Harding JE,Chase JG,CHYLD Study Group.

    更新日期:2012-08-06 00:00:00

  • Low-cost equipment for the evaluation of reach and grasp in post-stroke individuals: a pilot study.

    abstract:BACKGROUND:Reach-grasp movements are motor components commonly affected after stroke and directly related to the independence of these individuals. Evaluations of these activities can be performed using clinical instruments and assessed by detailed and costly kinematic analyses. The aim of this study was to develop an ...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-020-0758-7

    authors: Gomes CLA,Cacho RO,Nobrega VTB,de A Confessor EM,de Farias EEM,Neto JLF,de Araújo DS,de S Medeiros AL,Barreto RL,Cacho EWA

    更新日期:2020-03-04 00:00:00

  • Classification of voice disorder in children with cochlear implantation and hearing aid using multiple classifier fusion.

    abstract:BACKGROUND:Speech production and speech phonetic features gradually improve in children by obtaining audio feedback after cochlear implantation or using hearing aids. The aim of this study was to develop and evaluate automated classification of voice disorder in children with cochlear implantation and hearing aids. ME...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-10-3

    authors: Mahmoudi Z,Rahati S,Ghasemi MM,Asadpour V,Tayarani H,Rajati M

    更新日期:2011-01-14 00:00:00

  • Open source model for generating RR intervals in atrial fibrillation and beyond.

    abstract:BACKGROUND:Realistic modeling of cardiac inter-beat (RR) intervals is highly desirable for basic research in cardiac electrophysiology, clinical management of heart diseases, and developing signal processing tools for ECG analysis. METHODS:We present an open source computer model that is capable to generate realistic ...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-6-9

    authors: Lian J,Clifford GD,Müssig D,Lang V

    更新日期:2007-03-02 00:00:00

  • Human coronary plaque wall thickness correlated positively with flow shear stress and negatively with plaque wall stress: an IVUS-based fluid-structure interaction multi-patient study.

    abstract:BACKGROUND:Atherosclerotic plaque progression and rupture are believed to be associated with mechanical stress conditions. In this paper, patient-specific in vivo intravascular ultrasound (IVUS) coronary plaque image data were used to construct computational models with fluid-structure interaction (FSI) and cyclic bend...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-13-32

    authors: Fan R,Tang D,Yang C,Zheng J,Bach R,Wang L,Muccigrosso D,Billiar K,Zhu J,Ma G,Maehara A,Mintz GS

    更新日期:2014-03-26 00:00:00

  • 3-Dimensional printing in rehabilitation: feasibility of printing an upper extremity gross motor function assessment tool.

    abstract:BACKGROUND:Use of standardized and scientifically sound outcome measures is encouraged in clinical practice and research. With the development of newer rehabilitation therapies, we need technology-supported upper extremity outcome measures that are easily accessible, reliable and valid. 3-Dimensional printing (3D-print...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-020-00839-3

    authors: Kapadia N,Myers M,Musselman K,Wang RH,Yurkewich A,Popovic MR

    更新日期:2021-01-05 00:00:00

  • A specialized motion capture system for real-time analysis of mandibular movements using infrared cameras.

    abstract:BACKGROUND:In the last years, several methods and devices have been proposed to record the human mandibular movements, since they provide quantitative parameters that support the diagnosis and treatment of temporomandibular disorders. The techniques currently employed suffer from a number of drawbacks including high pr...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-12-17

    authors: Furtado DA,Pereira AA,Andrade Ade O,Bellomo DP Jr,da Silva MR

    更新日期:2013-02-22 00:00:00

  • Wound healing of human embryonic stem cell-derived retinal pigment epithelial cells is affected by maturation stage.

    abstract:BACKGROUND:Wound healing of retinal pigment epithelium (RPE) is a complex process that may take place in common age-related macular degeneration eye disease. The purpose of this study was to evaluate whether wounding and wound healing has an effect on Ca2+ dynamics in human embryonic stem cell (hESC)-RPEs cultured diff...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-018-0535-z

    authors: Abu Khamidakh AE,Rodriguez-Martinez A,Kaarniranta K,Kallioniemi A,Skottman H,Hyttinen J,Juuti-Uusitalo K

    更新日期:2018-07-31 00:00:00

  • Application safety evaluation of the radio frequency identification tag under magnetic resonance imaging.

    abstract:BACKGROUND:Radio Frequency Identification(RFID) has been widely used in healthcare facilities, but it has been paid little attention whether RFID applications are safe enough under healthcare environment. The purpose of this study is to assess the effects of RFID tags on Magnetic Resonance (MR) imaging in a typical ele...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-13-129

    authors: Fei X,Li S,Gao S,Wei L,Wang L

    更新日期:2014-09-04 00:00:00

  • Comparison of human uterine cervical electrical impedance measurements derived using two tetrapolar probes of different sizes.

    abstract:BACKGROUND:We sought to compare uterine cervical electrical impedance spectroscopy measurements employing two probes of different sizes, and to employ a finite element model to predict and compare the fraction of electrical current derived from subepithelial stromal tissue. METHODS:Cervical impedance was measured in 1...

    journal_title:Biomedical engineering online

    pub_type: 临床试验,杂志文章

    doi:10.1186/1475-925X-5-62

    authors: Gandhi SV,Walker DC,Brown BH,Anumba DO

    更新日期:2006-11-24 00:00:00

  • Non-viral eNOS gene delivery and transfection with stents for the treatment of restenosis.

    abstract:BACKGROUND:In this study, we have examined local non-viral gene delivery, transfection, and therapeutic efficacy of endothelial nitric oxide synthase (eNOS) encoding plasmid DNA administered using coated stents in a rabbit iliac artery restenosis model. METHODS:Lipopolyplexes (LPPs) with eNOS expressing plasmid DNA we...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-9-56

    authors: Brito LA,Chandrasekhar S,Little SR,Amiji MM

    更新日期:2010-09-27 00:00:00

  • 3D marker-controlled watershed for kidney segmentation in clinical CT exams.

    abstract:BACKGROUND:Image segmentation is an essential and non trivial task in computer vision and medical image analysis. Computed tomography (CT) is one of the most accessible medical examination techniques to visualize the interior of a patient's body. Among different computer-aided diagnostic systems, the applications dedic...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-018-0456-x

    authors: Wieclawek W

    更新日期:2018-02-27 00:00:00

  • Automatic QRS complex detection using two-level convolutional neural network.

    abstract:BACKGROUND:The QRS complex is the most noticeable feature in the electrocardiogram (ECG) signal, therefore, its detection is critical for ECG signal analysis. The existing detection methods largely depend on hand-crafted manual features and parameters, which may introduce significant computational complexity, especiall...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-018-0441-4

    authors: Xiang Y,Lin Z,Meng J

    更新日期:2018-01-29 00:00:00

  • Telepointer technology in telemedicine: a review.

    abstract::Telepointer is a powerful tool in the telemedicine system that enhances the effectiveness of long-distance communication. Telepointer has been tested in telemedicine, and has potential to a big influence in improving quality of health care, especially in the rural area. A telepointer system works by sending additional...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章,评审

    doi:10.1186/1475-925X-12-21

    authors: Abdul Karim R,Zakaria NF,Zulkifley MA,Mustafa MM,Sagap I,Md Latar NH

    更新日期:2013-03-09 00:00:00

  • Mathematical modelling of the action potential of human embryonic stem cell derived cardiomyocytes.

    abstract:BACKGROUND:Human embryonic stem cell derived cardiomyocytes (hESC-CMs) hold high potential for basic and applied cardiovascular research. The development of a reliable simulation platform able to mimic the functional properties of hESC-CMs would be of considerable value to perform preliminary test complementing in vitr...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-11-61

    authors: Paci M,Sartiani L,Del Lungo M,Jaconi M,Mugelli A,Cerbai E,Severi S

    更新日期:2012-08-28 00:00:00

  • Three types of dermal grafts in rats: the importance of mechanical property and structural design.

    abstract:BACKGROUND:To determine how the mechanical property and micro structure affect tissue regeneration and angiogenesis, three types of scaffolds were studied. Acellular dermal matrices (ADM), produced from human skin by removing the epidermis and cells, has been widely used in wound healing because of its high mechanical ...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-12-125

    authors: You C,Wang X,Zheng Y,Han C

    更新日期:2013-12-04 00:00:00