Abstract:
:A large number of incommensurable metrics are currently used to report the performance of brain-computer interfaces (BCI) used for augmentative and alterative communication (AAC). The lack of standard metrics precludes the comparison of different BCI-based AAC systems, hindering rapid growth and development of this technology. This paper presents a review of the metrics that have been used to report performance of BCIs used for AAC from January 2005 to January 2012. We distinguish between Level 1 metrics used to report performance at the output of the BCI Control Module, which translates brain signals into logical control output, and Level 2 metrics at the Selection Enhancement Module, which translates logical control to semantic control. We recommend that: (1) the commensurate metrics Mutual Information or Information Transfer Rate (ITR) be used to report Level 1 BCI performance, as these metrics represent information throughput, which is of interest in BCIs for AAC; 2) the BCI-Utility metric be used to report Level 2 BCI performance, as it is capable of handling all current methods of improving BCI performance; (3) these metrics should be supplemented by information specific to each unique BCI configuration; and (4) studies involving Selection Enhancement Modules should report performance at both Level 1 and Level 2 in the BCI system. Following these recommendations will enable efficient comparison between both BCI Control and Selection Enhancement Modules, accelerating research and development of BCI-based AAC systems.
journal_name
Biomed Eng Onlinejournal_title
Biomedical engineering onlineauthors
Thompson DE,Blain-Moraes S,Huggins JEdoi
10.1186/1475-925X-12-43subject
Has Abstractpub_date
2013-05-16 00:00:00pages
43issn
1475-925Xpii
1475-925X-12-43journal_volume
12pub_type
杂志文章abstract::Delivering short trains of electric pulses to the muscles and nerves can elicit action potentials resulting in muscle contractions. When the stimulations are sequenced to generate functional movements, such as grasping or walking, the application is referred to as functional electrical stimulation (FES). Implications ...
journal_title:Biomedical engineering online
pub_type: 杂志文章,评审
doi:10.1186/s12938-020-00824-w
更新日期:2020-11-04 00:00:00
abstract:BACKGROUND:Studies found that treatment symptoms of concern to oncology/hematology patients were greatly under-identified in medical records. On average, 11.0 symptoms were reported of concern to patients compared to 1.5 symptoms identified in their medical records. A solution to this problem is use of an electronic sy...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/1475-925X-14-S2-S1
更新日期:2015-01-01 00:00:00
abstract:BACKGROUND:In magnetic resonance electrical impedance tomography (MREIT), we reconstruct conductivity images using magnetic flux density data induced by externally injected currents. Since we extract magnetic flux density data from acquired MR phase images, the amount of measurement noise increases in regions of weak M...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/1475-925X-13-87
更新日期:2014-06-26 00:00:00
abstract:BACKGROUND:The replacement of hard tissues demands biocompatible and sometimes bioactive materials with properties similar to those of bone. Nano-composites made of biocompatible polymers and bioactive inorganic nano particles such as HDPE/HA have attracted attention as permanent bone substitutes due to their excellent...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/1475-925X-12-95
更新日期:2013-09-24 00:00:00
abstract:OBJECTIVE:Heart rate variability (HRV) analysis, which is an important tool for activity assessment of the cardiac autonomic nervous system, very often includes the estimation of power spectra for series of interbeat intervals (IBI). Ectopic beats and artifacts have a destructive effect on the standard methods (Fourier...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/1475-925X-13-138
更新日期:2014-09-23 00:00:00
abstract:BACKGROUND:It is a known fact that blood flow pattern and more specifically the pulsatile time variation of shear stress on the vascular wall play a key role in atherogenesis. The paper presents the conception, the building and the control of a new in vitro test bench that mimics the pulsatile flows behavior based on i...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/s12938-015-0065-x
更新日期:2015-08-07 00:00:00
abstract::It was highlighted that the original article [1] contained an error in the Acknowledgments section. ...
journal_title:Biomedical engineering online
pub_type: 杂志文章,已发布勘误
doi:10.1186/s12938-019-0707-5
更新日期:2019-08-08 00:00:00
abstract:BACKGROUND:Classification of breast ultrasound (BUS) images is an important step in the computer-aided diagnosis (CAD) system for breast cancer. In this paper, a novel phase-based texture descriptor is proposed for efficient and robust classifiers to discriminate benign and malignant tumors in BUS images. METHOD:The p...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/s12938-015-0022-8
更新日期:2015-03-24 00:00:00
abstract:BACKGROUND:Robot-assisted laparoscopic surgery offers several advantages compared with open surgery and conventional minimally invasive surgery. However, one issue that needs to be resolved is a collision between the robot arm and the assistant instrument. This is mostly caused by miscommunication between the surgeon a...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/s12938-016-0189-7
更新日期:2016-05-20 00:00:00
abstract::Radiofrequency ablation is an interventional technique that in recent years has come to be employed in very different medical fields, such as the elimination of cardiac arrhythmias or the destruction of tumors in different locations. In order to investigate and develop new techniques, and also to improve those current...
journal_title:Biomedical engineering online
pub_type: 杂志文章,评审
doi:10.1186/1475-925X-5-24
更新日期:2006-04-18 00:00:00
abstract:BACKGROUND:To determine how the mechanical property and micro structure affect tissue regeneration and angiogenesis, three types of scaffolds were studied. Acellular dermal matrices (ADM), produced from human skin by removing the epidermis and cells, has been widely used in wound healing because of its high mechanical ...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/1475-925X-12-125
更新日期:2013-12-04 00:00:00
abstract:BACKGROUND:Maximum Intensity Projections (MIP) of neuronal dendritic trees obtained from confocal microscopy are frequently used to study the relationship between tree morphology and mechanosensory function in the model organism C. elegans. Extracting dendritic trees from noisy images remains however a strenuous proces...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/1475-925X-13-74
更新日期:2014-06-12 00:00:00
abstract:BACKGROUND:Nonnegative matrix factorization (NMF) has been successfully used for electroencephalography (EEG) spectral analysis. Since NMF was proposed in the 1990s, many adaptive algorithms have been developed. However, the performance of their use in EEG data analysis has not been fully compared. Here, we provide a c...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/s12938-020-00796-x
更新日期:2020-07-31 00:00:00
abstract:BACKGROUND:Stroke is one of the major causes of morbidity and mortality. Its recovery and treatment depends on close clinical monitoring by a clinician especially during the first few hours after the onset of stroke. Patients who do not exhibit early motor recovery post thrombolysis may benefit from more aggressive tre...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/1475-925X-12-33
更新日期:2013-04-16 00:00:00
abstract:BACKGROUND:The QRS complex is the most noticeable feature in the electrocardiogram (ECG) signal, therefore, its detection is critical for ECG signal analysis. The existing detection methods largely depend on hand-crafted manual features and parameters, which may introduce significant computational complexity, especiall...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/s12938-018-0441-4
更新日期:2018-01-29 00:00:00
abstract:INTRODUCTION:The method for measuring intraocular pressure using the Corvis tonometer provides a sequence of images of corneal deformation. Deformations of the cornea are recorded using the ultra-high-speed Scheimpflug camera. This paper presents a new and reproducible method of analysis of corneal deformation images t...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/1475-925X-13-150
更新日期:2014-11-19 00:00:00
abstract:BACKGROUND:The evaluation, verification and comparison of different numerical heart models are difficult without a commonly available database that could be utilized as a reference. Our aim was to compile an exemplary dataset. METHODS:The following methods were employed: Magnetic Resonance Imaging (MRI) of heart and t...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/1475-925X-10-11
更新日期:2011-01-27 00:00:00
abstract:BACKGROUND:Good anatomical compatibility is an important aspect in the development of cardiovascular implants. This work analyzes the interaction of the pump unit of an electrically driven pulsatile Total Artificial Heart (TAH) and the mediastinum. For an adequate compliance, both overall dimensions and alignment of in...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/1475-925X-12-81
更新日期:2013-08-14 00:00:00
abstract:BACKGROUND:Non-contact tonometers based on the method using air puff and Scheimpflug's fast camera are one of the latest devices allowing the measurement of intraocular pressure and additional biomechanical parameters of the cornea. Biomechanical features significantly affect changes in intraocular pressure values, as ...
journal_title:Biomedical engineering online
pub_type: 杂志文章,评审
doi:10.1186/s12938-019-0636-3
更新日期:2019-02-13 00:00:00
abstract:BACKGROUND:Recent studies indicate that the blue-yellow colour discrimination is impaired in ADHD individuals. However, the relationship between colour and performance has not been investigated. This paper describes the development and the testing of a virtual environment that is capable to quantify the influence of re...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/1475-925X-10-74
更新日期:2011-08-19 00:00:00
abstract:BACKGROUND:With the aging population and rising healthcare costs, wearable monitoring is gaining importance. The motion artifact affecting dry electrodes is one of the main challenges preventing the widespread use of wearable monitoring systems. In this paper we investigate the motion artifact and ways of making a text...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/1475-925X-12-26
更新日期:2013-04-08 00:00:00
abstract:BACKGROUND:Gait analysis and research have been developed to obtain characteristics of movement patterns of people while walking. However, traditional measuring systems present different drawbacks that reduce their use and application. Among those drawbacks one can find: high price, low sampling frequency and limiting ...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/1475-925X-13-34
更新日期:2014-03-31 00:00:00
abstract:BACKGROUND:Pancreatic ductal adenocarcinoma (PDAC) is one of the most lethal tumors and usually presented with locally advanced and distant metastasis disease, which prevent curative resection or treatments. In this regard, we considered identifying molecular subtypes associated with clinicopathological factor as progn...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/1475-925X-13-S2-S5
更新日期:2014-01-01 00:00:00
abstract:BACKGROUND:The low quality of diffusion tensor image (DTI) could affect the accuracy of oncology diagnosis. METHODS:We present a novel sparse representation based denoising method for three dimensional DTI by learning adaptive dictionary with the context redundancy between neighbor slices. In this study, the context r...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/s12938-015-0116-3
更新日期:2016-01-13 00:00:00
abstract:BACKGROUND:Colonoscopy plays an important role in the clinical screening and management of colorectal cancer. The traditional 'see one, do one, teach one' training style for such invasive procedure is resource intensive and ineffective. Given that colonoscopy is difficult, and time-consuming to master, the use of virtu...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/s12938-018-0433-4
更新日期:2018-01-25 00:00:00
abstract:BACKGROUND:The paper presents an approach and computer-aided method of numerical evaluation of the quality of porous membranes used as scaffolds for cultivation of chondrocytes in regeneration of biological tissues. MATERIALS:The scanning electron microscope (SEM) images of 300× and 1000× magnification presenting the ...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/s12938-018-0481-9
更新日期:2018-05-30 00:00:00
abstract:BACKGROUND:Mobile health apps (mHealth apps) are increasing in popularity and utility for the management of many chronic diseases. Although the current reimbursement structure for mHealth apps is lagging behind the rapidly improving functionality, more clinicians will begin to recommend these apps as they prove their c...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/s12938-018-0611-4
更新日期:2018-12-17 00:00:00
abstract:BACKGROUND:Entropy analysis has been attracting increasing attentions in the recent two or three decades. It assesses complexity, or irregularity, of time-series which is extraordinarily relevant to physiology and diseases as demonstrated by tremendous studies. However, the complexity can hardly be appreciated by tradi...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/s12938-019-0650-5
更新日期:2019-03-20 00:00:00
abstract:BACKGROUND:This paper proposes a methodology for helping bridge the gap between the complex waveform information frequently available in an intensive care unit and the simple, lumped values favoured for rapid clinical diagnosis and management. This methodology employs a simple waveform contour analysis approach to comp...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/s12938-018-0603-4
更新日期:2018-11-20 00:00:00
abstract:BACKGROUND:Regional differences in action potential duration (APD) restitution in the heart favour arrhythmias, but the mechanism is not well understood. METHODS:We simulated a 150 x 150 mm 2D sheet of cardiac ventricular tissue using a simplified computational model. We investigated wavebreak and re-entry initiated b...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/1475-925X-4-54
更新日期:2005-09-20 00:00:00