Abstract:
BACKGROUND:Radio Frequency Identification(RFID) has been widely used in healthcare facilities, but it has been paid little attention whether RFID applications are safe enough under healthcare environment. The purpose of this study is to assess the effects of RFID tags on Magnetic Resonance (MR) imaging in a typical electromagnetic environment in hospitals, and to evaluate the safety of their applications. METHODS:A Magphan phantom was used to simulate the imaging objects, while active RFID tags were placed at different distances (0, 4, 8, 10 cm) from the phantom border. The phantom was scanned by using three typical sequences including spin-echo (SE) sequence, gradient-echo (GRE) sequence and inversion-recovery (IR) sequence. The quality of the image was quantitatively evaluated by using signal-to-noise ratio (SNR), uniformity, high-contrast resolution, and geometric distortion. RFID tags were read by an RFID reader to calculate their usable rate. RESULTS:RFID tags can be read properly after being placed in high magnetic field for up to 30 minutes. SNR: There were no differences between the group with RFID tags and the group without RFID tags using SE and IR sequence, but it was lower when using GRE sequence.Uniformity: There was a significant difference between the group with RFID tags and the group without RFID tags using SE and GRE sequence. Geometric distortion and high-contrast resolution: There were no obvious differences found. CONCLUSIONS:Active RFID tags can affect MR imaging quality, especially using the GRE sequence. Increasing the distance from the RFID tags to the imaging objects can reduce that influence. When the distance was longer than 8 cm, MR imaging quality were almost unaffected. However, the Gradient Echo related sequence is not recommended when patients wear a RFID wristband.
journal_name
Biomed Eng Onlinejournal_title
Biomedical engineering onlineauthors
Fei X,Li S,Gao S,Wei L,Wang Ldoi
10.1186/1475-925X-13-129subject
Has Abstractpub_date
2014-09-04 00:00:00pages
129issn
1475-925Xpii
1475-925X-13-129journal_volume
13pub_type
杂志文章abstract:BACKGROUND:Segmentation is the most crucial part in the computer-aided bone age assessment. A well-known type of segmentation performed in the system is adaptive segmentation. While providing better result than global thresholding method, the adaptive segmentation produces a lot of unwanted noise that could affect the ...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/1475-925X-10-87
更新日期:2011-09-28 00:00:00
abstract:BACKGROUND:In the last years, several methods and devices have been proposed to record the human mandibular movements, since they provide quantitative parameters that support the diagnosis and treatment of temporomandibular disorders. The techniques currently employed suffer from a number of drawbacks including high pr...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/1475-925X-12-17
更新日期:2013-02-22 00:00:00
abstract:BACKGROUND:EMG-to-force estimation based on muscle models, for voluntary contraction has many applications in human motion analysis. The so-called Hill model is recognized as a standard model for this practical use. However, it is a phenomenological model whereby muscle activation, force-length and force-velocity prope...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/1475-925X-12-86
更新日期:2013-09-04 00:00:00
abstract:BACKGROUND:This study investigates CAD/CAM ceramic cusp-replacing restoration resistance with and without buccal cusp replacement under static and dynamic cyclic loads, monitored using the acoustic emission (AE) technique. METHOD:The cavity was designed in a typical MODP (mesial-occlusal-distal-palatal) restoration fa...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/1475-925X-13-165
更新日期:2014-12-13 00:00:00
abstract:BACKGROUND:A specific problem using the public access defibrillators (PADs) arises at the railway stations. Some countries as Germany, Austria, Switzerland, Norway and Sweden are using AC railroad net power-supply system with rated 16.7 Hz frequency modulated from 15.69 Hz to 17.36 Hz. The power supply frequency contam...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/1475-925X-4-16
更新日期:2005-03-15 00:00:00
abstract:BACKGROUND:Speech production and speech phonetic features gradually improve in children by obtaining audio feedback after cochlear implantation or using hearing aids. The aim of this study was to develop and evaluate automated classification of voice disorder in children with cochlear implantation and hearing aids. ME...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/1475-925X-10-3
更新日期:2011-01-14 00:00:00
abstract:BACKGROUND:Rotational osteotomy is frequently indicated to correct excessive femoral anteversion in cerebral palsy patients. Angled blade plate is the standard fixation device used when performed in the proximal femur, but extensile exposure is required for plate accommodation. The authors developed a short locked intr...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/1475-925X-10-57
更新日期:2011-06-28 00:00:00
abstract:BACKGROUND:The subjects in EEG-Brain computer interface (BCI) system experience difficulties when attempting to obtain the consistent performance of the actual movement by motor imagery alone. It is necessary to find the optimal conditions and stimuli combinations that affect the performance factors of the EEG-BCI syst...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/1475-925X-10-91
更新日期:2011-10-12 00:00:00
abstract:BACKGROUND:Effective fixation of fracture requires careful selection of a suitable implant to provide stability and durability. Implant with a feature of locking plate (LP) has been used widely for treating distal fractures in femur because of its favourable clinical outcome, but its potential in fixing proximal fractu...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/1475-925X-11-23
更新日期:2012-04-30 00:00:00
abstract:BACKGROUND:The lumbar range of motion has traditionally been used to assess disability in patients with low back disorders. Controversy exists about how movement ranges in static positions or in a single straight plane is related to the functional status of the patients. The trunk circumduction, as the result of neurom...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/1475-925X-12-4
更新日期:2013-01-11 00:00:00
abstract:BACKGROUND:Analysis of heart rate variation (HRV) has become a popular noninvasive tool for assessing the activities of the autonomic nervous system (ANS). HRV analysis is based on the concept that fast fluctuations may specifically reflect changes of sympathetic and vagal activity. It shows that the structure generati...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/1475-925X-3-24
更新日期:2004-07-20 00:00:00
abstract:BACKGROUND:Intracranial pressure changes during head impact cause brain injuries such as vasogenic edema and cerebral contusion. However, the influence of impulsive pressure on endothelial function has not yet been fully studied in vitro. In this study, we developed a pressure loading device that produced positive and ...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/1475-925X-13-44
更新日期:2014-04-16 00:00:00
abstract:BACKGROUND:For electroporation-based therapies, accurate modeling of the electric field distribution within the target tissue is important for predicting the treatment volume. In response to conventional, unipolar pulses, the electrical impedance of a tissue varies as a function of the local electric field, leading to ...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/1475-925X-14-S3-S3
更新日期:2015-01-01 00:00:00
abstract:BACKGROUND:Maximum Intensity Projections (MIP) of neuronal dendritic trees obtained from confocal microscopy are frequently used to study the relationship between tree morphology and mechanosensory function in the model organism C. elegans. Extracting dendritic trees from noisy images remains however a strenuous proces...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/1475-925X-13-74
更新日期:2014-06-12 00:00:00
abstract:BACKGROUND:The low quality of diffusion tensor image (DTI) could affect the accuracy of oncology diagnosis. METHODS:We present a novel sparse representation based denoising method for three dimensional DTI by learning adaptive dictionary with the context redundancy between neighbor slices. In this study, the context r...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/s12938-015-0116-3
更新日期:2016-01-13 00:00:00
abstract:BACKGROUND:Sleep apnea (OSA) is a common sleep disorder characterized by recurring breathing pauses during sleep caused by a blockage of the upper airway (UA). The altered UA structure or function in OSA speakers has led to hypothesize the automatic analysis of speech for OSA assessment. In this paper we critically rev...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/s12938-016-0138-5
更新日期:2016-02-20 00:00:00
abstract:BACKGROUND:Perfluorocarbon (PFC) vapour in the expired gases during partial liquid ventilation should be prevented from entering the atmosphere and recovered for potential reuse. This study aimed to determine how much PFC liquid could be recovered using a conventional humidified neonatal ventilator with chilled condens...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/1475-925X-6-19
更新日期:2007-05-31 00:00:00
abstract:BACKGROUND:Non-contact tonometers based on the method using air puff and Scheimpflug's fast camera are one of the latest devices allowing the measurement of intraocular pressure and additional biomechanical parameters of the cornea. Biomechanical features significantly affect changes in intraocular pressure values, as ...
journal_title:Biomedical engineering online
pub_type: 杂志文章,评审
doi:10.1186/s12938-019-0636-3
更新日期:2019-02-13 00:00:00
abstract:BACKGROUND:Quantizing the Breast Imaging Reporting and Data System (BI-RADS) criteria into different categories with the single ultrasound modality has always been a challenge. To achieve this, we proposed a two-stage grading system to automatically evaluate breast tumors from ultrasound images into five categories bas...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/s12938-019-0626-5
更新日期:2019-01-24 00:00:00
abstract:BACKGROUND:Studies have identified hemodynamic shear stress as an important determinant of endothelial function and atherosclerosis. In this study, we assess the influences of hemodynamic shear stress on carotid plaques. METHODS:Carotid stenosis phantoms with three severity (30, 50, 70%) were made from 10% polyvinyl a...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/s12938-017-0386-z
更新日期:2017-07-29 00:00:00
abstract:OBJECTIVE:To evaluate the in vivo and in vitro performance of a China-made dialysis machine (SWS-4000). METHODS:This was a multi-center prospective controlled study consisting of both long-term in vitro evaluations and cross-over in vivo tests in 132 patients. The China-made SWS-4000 dialysis machine was compared with...
journal_title:Biomedical engineering online
pub_type: 临床试验,杂志文章,多中心研究
doi:10.1186/s12938-017-0387-y
更新日期:2017-08-02 00:00:00
abstract:BACKGROUND:Since the first well-known electrocardiogram (ECG) delineator based on Wavelet Transform (WT) presented by Li et al. in 1995, a significant research effort has been devoted to the exploitation of this promising method. Its ability to reliably delineate the major waveform components (mono- or bi-phasic P wave...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/1475-925X-10-23
更新日期:2011-04-03 00:00:00
abstract:BACKGROUND:In magnetic resonance electrical impedance tomography (MREIT), we reconstruct conductivity images using magnetic flux density data induced by externally injected currents. Since we extract magnetic flux density data from acquired MR phase images, the amount of measurement noise increases in regions of weak M...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/1475-925X-13-87
更新日期:2014-06-26 00:00:00
abstract:BACKGROUND:Nonnegative matrix factorization (NMF) has been successfully used for electroencephalography (EEG) spectral analysis. Since NMF was proposed in the 1990s, many adaptive algorithms have been developed. However, the performance of their use in EEG data analysis has not been fully compared. Here, we provide a c...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/s12938-020-00796-x
更新日期:2020-07-31 00:00:00
abstract:BACKGROUND:Areas with high frequency activity within the atrium are thought to be 'drivers' of the rhythm in patients with atrial fibrillation (AF) and ablation of these areas seems to be an effective therapy in eliminating DF gradient and restoring sinus rhythm. Clinical groups have applied the traditional FFT-based a...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/s12938-016-0143-8
更新日期:2016-03-08 00:00:00
abstract:BACKGROUND:Increasing evidence suggests that mechanisms governing advanced plaque progression may be different from those for early progression and require further investigation. Serial MRI data and 3D fluid-structure interaction (FSI) models were employed to identify possible correlations between mechanical stresses a...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/1475-925X-12-105
更新日期:2013-10-14 00:00:00
abstract:BACKGROUND:We and others have previously demonstrated that adipose-derived stem cells (ASCs) transplantation improve cardiac dysfunction post-myocardium infarction (MI) under hemodynamic stress in rats. The beneficial effects appear to be associated with pleiotropic factors due to a complex interplay between the transp...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/1475-925X-13-54
更新日期:2014-05-01 00:00:00
abstract:BACKGROUND:Robot-based joint-testing systems (RJTS) can be used to perform unconstrained laxity tests, measuring the stiffness of a degree of freedom (DOF) of the joint at a fixed flexion angle while allowing the other DOFs unconstrained movement. Previous studies using the force-position hybrid (FPH) control method pr...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/s12938-016-0195-9
更新日期:2016-06-07 00:00:00
abstract:BACKGROUND:Classification of breast ultrasound (BUS) images is an important step in the computer-aided diagnosis (CAD) system for breast cancer. In this paper, a novel phase-based texture descriptor is proposed for efficient and robust classifiers to discriminate benign and malignant tumors in BUS images. METHOD:The p...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/s12938-015-0022-8
更新日期:2015-03-24 00:00:00
abstract:BACKGROUND:The replacement of hard tissues demands biocompatible and sometimes bioactive materials with properties similar to those of bone. Nano-composites made of biocompatible polymers and bioactive inorganic nano particles such as HDPE/HA have attracted attention as permanent bone substitutes due to their excellent...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/1475-925X-12-95
更新日期:2013-09-24 00:00:00