Novel dynamic corneal response parameters in a practice use: a critical review.

Abstract:

BACKGROUND:Non-contact tonometers based on the method using air puff and Scheimpflug's fast camera are one of the latest devices allowing the measurement of intraocular pressure and additional biomechanical parameters of the cornea. Biomechanical features significantly affect changes in intraocular pressure values, as well as their changes, may indicate the possibility of corneal ectasia. This work presents the latest and already known biomechanical parameters available in the new offered software. The authors focused on their practical application and the diagnostic credibility indicated in the literature. DISCUSSION:An overview of available literature indicates the importance of new dynamic corneal parameters. The latest parameters developed on the basis of biomechanics analysis of corneal deformation process, available in non-contact tonometers using Scheimpflug's fast camera, are used in the evaluation of laser refractive surgery procedures, e.g. LASIK procedure. In addition, the assessment of changes in biomechanically corrected intraocular pressure confirms its independence from changes in the corneal biomechanics which may allow an intraocular pressure real assessment. The newly developed Corvis Biomechanical Index combined with the corneal tomography and topography assessment is an important aid in the classification of patients with keratoconus. CONCLUSION:New parameters characterising corneal deformation, including Corvis Biomechanical Index and biomechanical compensated intraocular pressure, significantly extend the diagnostic capabilities of this device and may be helpful in assessing corneal diseases of the eye. Nevertheless, further research is needed to confirm their diagnostic pertinence.

journal_name

Biomed Eng Online

authors

Jędzierowska M,Koprowski R

doi

10.1186/s12938-019-0636-3

subject

Has Abstract

pub_date

2019-02-13 00:00:00

pages

17

issue

1

issn

1475-925X

pii

10.1186/s12938-019-0636-3

journal_volume

18

pub_type

杂志文章,评审
  • NeoAnalysis: a Python-based toolbox for quick electrophysiological data processing and analysis.

    abstract:BACKGROUND:In a typical electrophysiological experiment, especially one that includes studying animal behavior, the data collected normally contain spikes, local field potentials, behavioral responses and other associated data. In order to obtain informative results, the data must be analyzed simultaneously with the ex...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-017-0419-7

    authors: Zhang B,Dai J,Zhang T

    更新日期:2017-11-13 00:00:00

  • 16-Channel biphasic current-mode programmable charge balanced neural stimulation.

    abstract:BACKGROUND:Neural stimulation is an important method used to activate or inhibit action potentials of the neuronal anatomical targets found in the brain, central nerve and peripheral nerve. The neural stimulator system produces biphasic pulses that deliver balanced charge into tissue from single or multichannel electro...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-017-0385-0

    authors: Li X,Zhong S,Morizio J

    更新日期:2017-08-14 00:00:00

  • A transition-constrained discrete hidden Markov model for automatic sleep staging.

    abstract:BACKGROUND:Approximately one-third of the human lifespan is spent sleeping. To diagnose sleep problems, all-night polysomnographic (PSG) recordings including electroencephalograms (EEGs), electrooculograms (EOGs) and electromyograms (EMGs), are usually acquired from the patient and scored by a well-trained expert accor...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-11-52

    authors: Pan ST,Kuo CE,Zeng JH,Liang SF

    更新日期:2012-08-21 00:00:00

  • Wound healing of human embryonic stem cell-derived retinal pigment epithelial cells is affected by maturation stage.

    abstract:BACKGROUND:Wound healing of retinal pigment epithelium (RPE) is a complex process that may take place in common age-related macular degeneration eye disease. The purpose of this study was to evaluate whether wounding and wound healing has an effect on Ca2+ dynamics in human embryonic stem cell (hESC)-RPEs cultured diff...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-018-0535-z

    authors: Abu Khamidakh AE,Rodriguez-Martinez A,Kaarniranta K,Kallioniemi A,Skottman H,Hyttinen J,Juuti-Uusitalo K

    更新日期:2018-07-31 00:00:00

  • Robust phase-based texture descriptor for classification of breast ultrasound images.

    abstract:BACKGROUND:Classification of breast ultrasound (BUS) images is an important step in the computer-aided diagnosis (CAD) system for breast cancer. In this paper, a novel phase-based texture descriptor is proposed for efficient and robust classifiers to discriminate benign and malignant tumors in BUS images. METHOD:The p...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-015-0022-8

    authors: Cai L,Wang X,Wang Y,Guo Y,Yu J,Wang Y

    更新日期:2015-03-24 00:00:00

  • Investigation of red blood cell mechanical properties using AFM indentation and coarse-grained particle method.

    abstract:BACKGROUND:Red blood cells (RBCs) deform significantly and repeatedly when passing through narrow capillaries and delivering dioxygen throughout the body. Deformability of RBCs is a key characteristic, largely governed by the mechanical properties of the cell membrane. This study investigated RBC mechanical properties ...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-017-0429-5

    authors: Barns S,Balanant MA,Sauret E,Flower R,Saha S,Gu Y

    更新日期:2017-12-19 00:00:00

  • Voluntary EMG-to-force estimation with a multi-scale physiological muscle model.

    abstract:BACKGROUND:EMG-to-force estimation based on muscle models, for voluntary contraction has many applications in human motion analysis. The so-called Hill model is recognized as a standard model for this practical use. However, it is a phenomenological model whereby muscle activation, force-length and force-velocity prope...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-12-86

    authors: Hayashibe M,Guiraud D

    更新日期:2013-09-04 00:00:00

  • Effect of amplitude and duration of impulsive pressure on endothelial permeability in in vitro fluid percussion trauma.

    abstract:BACKGROUND:Intracranial pressure changes during head impact cause brain injuries such as vasogenic edema and cerebral contusion. However, the influence of impulsive pressure on endothelial function has not yet been fully studied in vitro. In this study, we developed a pressure loading device that produced positive and ...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-13-44

    authors: Nakadate H,Inuzuka K,Akanuma S,Kakuta A,Aomura S

    更新日期:2014-04-16 00:00:00

  • Biomechanical investigation of dynamic hip screw and wire fixation on an unstable intertrochanteric fracture.

    abstract:BACKGROUND:Although use of a dynamic hip screw (DHS) for stable intertrochanteric hip fracture fixation has been successfully applied in fracture healing for more than 20 years, DHS fixation on unstable intertrochanteric fractures still has a high failure rate, especially in patients with osteoporosis. Although the wir...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-019-0663-0

    authors: Wu HF,Chang CH,Wang GJ,Lai KA,Chen CH

    更新日期:2019-04-24 00:00:00

  • Evaluation of needle movement effect on root canal irrigation using a computational fluid dynamics model.

    abstract:BACKGROUND:Irrigation is considered to be a critical part of root canal treatment. However, little is known about the effect of needle movement on the irrigation process. Therefore, this study aimed to investigate the influence of the syringe and needle movement on root canal irrigation using a three-dimensional comput...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-019-0679-5

    authors: Hu S,Duan L,Wan Q,Wang J

    更新日期:2019-05-06 00:00:00

  • Influence of model boundary conditions on blood flow patterns in a patient specific stenotic right coronary artery.

    abstract:BACKGROUND:In literature, the effect of the inflow boundary condition was investigated by examining the impact of the waveform and the shape of the spatial profile of the inlet velocity on the cardiac hemodynamics. However, not much work has been reported on comparing the effect of the different combinations of the inl...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-14-S1-S6

    authors: Liu B,Zheng J,Bach R,Tang D

    更新日期:2015-01-01 00:00:00

  • Evolutionary optimization of classifiers and features for single-trial EEG discrimination.

    abstract:BACKGROUND:State-of-the-art signal processing methods are known to detect information in single-trial event-related EEG data, a crucial aspect in development of real-time applications such as brain computer interfaces. This paper investigates one such novel approach, evaluating how individual classifier and feature sub...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-6-32

    authors: Aberg MC,Wessberg J

    更新日期:2007-08-23 00:00:00

  • Quantification of functional hand grip using electromyography and inertial sensor-derived accelerations: clinical implications.

    abstract:BACKGROUND:Assessing hand injury is of great interest given the level of involvement of the hand with the environment. Knowing different assessment systems and their limitations generates new perspectives. The integration of digital systems (accelerometry and electromyography) as a tool to supplement functional assessm...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-13-161

    authors: Martin-Martin J,Cuesta-Vargas AI

    更新日期:2014-12-11 00:00:00

  • The assessment of xenogeneic bone immunotoxicity and risk management study.

    abstract:BACKGROUND:Xenogeneic bone has been widely used in a variety of clinical bone-related disease to promote bone healing and restore bone defects. However, the adverse effects of immune system limit its application in the clinic. The aim of this study was to evaluate xenogeneic bone safety of immunotoxicity and explore th...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-019-0729-z

    authors: Sun X,Liu C,Shi Y,Li C,Sun L,Hou L,Wang X

    更新日期:2019-11-14 00:00:00

  • The effect of baseline pressure errors on an intracranial pressure-derived index: results of a prospective observational study.

    abstract:BACKGROUND:In order to characterize the intracranial pressure-volume reserve capacity, the correlation coefficient (R) between the ICP wave amplitude (A) and the mean ICP level (P), the RAP index, has been used to improve the diagnostic value of ICP monitoring. Baseline pressure errors (BPEs), caused by spontaneous shi...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-13-99

    authors: Eide PK,Sorteberg A,Meling TR,Sorteberg W

    更新日期:2014-07-23 00:00:00

  • A numerical study of the effect of varied blood pressure on the stability of carotid atherosclerotic plaque.

    abstract:BACKGROUND:Blood pressure (BP) is associated with early atherosclerosis and plaque rupture because the BP variability can significantly affect the blood flow velocity and shear stress over the plaque. However, the mechanical response of BP variability to the plaque remains unclear. Therefore, we investigated the correl...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-13-152

    authors: Xiong H,Liu X,Tian X,Pu L,Zhang H,Lu M,Huang W,Zhang YT

    更新日期:2014-11-20 00:00:00

  • Extraction of average neck flexion angle during swallowing in neutral and chin-tuck positions.

    abstract:BACKGROUND:A common but debated technique in the management of swallowing difficulties is the chin tuck swallow, where the neck is flexed forward prior to swallowing. Natural variations in chin tuck angles across individuals may contribute to the differential effectiveness of the technique. METHODOLOGY:To facilitate t...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-8-25

    authors: Hung D,Sejdić E,Steele CM,Chau T

    更新日期:2009-10-07 00:00:00

  • Biomechanical simulation of thorax deformation using finite element approach.

    abstract:BACKGROUND:The biomechanical simulation of the human respiratory system is expected to be a useful tool for the diagnosis and treatment of respiratory diseases. Because the deformation of the thorax significantly influences airflow in the lungs, we focused on simulating the thorax deformation by introducing contraction...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-016-0132-y

    authors: Zhang G,Chen X,Ohgi J,Miura T,Nakamoto A,Matsumura C,Sugiura S,Hisada T

    更新日期:2016-02-06 00:00:00

  • A fast and stable vascular deformation scheme for interventional surgery training system.

    abstract:BACKGROUND:The emergence and development of robot assistant interventional vascular surgery technologies have benefited many patients with cardiovascular or cerebrovascular diseases. Due to the absence of effective training measures, these new advanced technologies have not been fully utilized and only few experienced ...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-016-0148-3

    authors: Ye X,Zhang J,Li P,Wang T,Guo S

    更新日期:2016-04-06 00:00:00

  • Evaluation of flow changes after telescopic stenting of a giant fusiform aneurysm of the vertebrobasilar junction.

    abstract:BACKGROUND:The use of flow-diverters for non-saccular cerebral posterior circulation aneurysms requires complex deployment techniques and is associated with high mortality and morbidity. Therefore, further studies are required to clarify the effect of stenting on post-treatment hemodynamics in such aneurysms. In this s...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-019-0699-1

    authors: Sindeev S,Kirschke JS,Prothmann S,Frolov S,Liepsch D,Berg P,Zimmer C,Friedrich B

    更新日期:2019-07-24 00:00:00

  • Low-dose CT reconstruction via L1 dictionary learning regularization using iteratively reweighted least-squares.

    abstract:BACKGROUND:In order to reduce the radiation dose of CT (computed tomography), compressed sensing theory has been a hot topic since it provides the possibility of a high quality recovery from the sparse sampling data. Recently, the algorithm based on DL (dictionary learning) was developed to deal with the sparse CT reco...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-016-0193-y

    authors: Zhang C,Zhang T,Li M,Peng C,Liu Z,Zheng J

    更新日期:2016-06-18 00:00:00

  • Data-guide for brain deformation in surgery: comparison of linear and nonlinear models.

    abstract:BACKGROUND:Pre-operative imaging devices generate high-resolution images but intra-operative imaging devices generate low-resolution images. To use high-resolution pre-operative images during surgery, they must be deformed to reflect intra-operative geometry of brain. METHODS:We employ biomechanical models, guided by ...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-9-51

    authors: Hamidian H,Soltanian-Zadeh H,Faraji-Dana R,Gity M

    更新日期:2010-09-15 00:00:00

  • Simulating the swelling and deformation behaviour in soft tissues using a convective thermal analogy.

    abstract:BACKGROUND:It is generally accepted that cartilage adaptation and degeneration are mechanically mediated. Investigating the swelling behaviour of cartilage is important because the stress and strain state of cartilage is associated with the swelling and deformation behaviour. It is well accepted that the swelling of so...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925x-1-8

    authors: Wu JZ,Herzog W

    更新日期:2002-12-19 00:00:00

  • Correction to: Proposal of a new conceptual gait model for patients with Parkinson's disease based on factor analysis.

    abstract::It was highlighted that the original article [1] had an omission in the Abstract. This Correction article shows the omitted sentence: "This article [1] was awarded the SIAMOC Best Methodological Paper 2018". ...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章,已发布勘误

    doi:10.1186/s12938-019-0698-2

    authors: Arcolin I,Corna S,Giardini M,Giordano A,Nardone A,Godi M

    更新日期:2019-07-23 00:00:00

  • Challenges, issues and trends in fall detection systems.

    abstract::Since falls are a major public health problem among older people, the number of systems aimed at detecting them has increased dramatically over recent years. This work presents an extensive literature review of fall detection systems, including comparisons among various kinds of studies. It aims to serve as a referenc...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章,评审

    doi:10.1186/1475-925X-12-66

    authors: Igual R,Medrano C,Plaza I

    更新日期:2013-07-06 00:00:00

  • 3D kernel-density stochastic model for more personalized glycaemic control: development and in-silico validation.

    abstract:BACKGROUND:The challenges of glycaemic control in critically ill patients have been debated for 20 years. While glycaemic control shows benefits inter- and intra-patient metabolic variability results in increased hypoglycaemia and glycaemic variability, both increasing morbidity and mortality. Hence, current recommenda...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-019-0720-8

    authors: Uyttendaele V,Knopp JL,Davidson S,Desaive T,Benyo B,Shaw GM,Chase JG

    更新日期:2019-10-22 00:00:00

  • A multivariate relationship between the kinematic and clinical parameters of knee osteoarthritis population.

    abstract:BACKGROUND:Biomechanical and clinical parameters contribute very closely to functional evaluations of the knee joint. To better understand knee osteoarthritis joint function, the association between a set of knee biomechanical data and a set of clinical parameters of an osteoarthritis population (OA) is investigated in...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-019-0676-8

    authors: Bensalma F,Mezghani N,Ouakrim Y,Fuentes A,Choinière M,Bureau NJ,Durand M,Hagemeister N

    更新日期:2019-05-15 00:00:00

  • The effect of inlet and outlet boundary conditions in image-based CFD modeling of aortic flow.

    abstract:BACKGROUND:Computational modeling of cardiovascular flow is a growing and useful field, but such simulations usually require the researcher to guess the flow's inlet and outlet conditions since they are difficult and expensive to measure. It is critical to determine the amount of uncertainty introduced by these assumpt...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-018-0497-1

    authors: Madhavan S,Kemmerling EMC

    更新日期:2018-05-30 00:00:00

  • Risk and reward: extending stochastic glycaemic control intervals to reduce workload.

    abstract:BACKGROUND:STAR is a model-based, personalised, risk-based dosing approach for glycaemic control (GC) in critically ill patients. STAR provides safe, effective control to nearly all patients, using 1-3 hourly measurement and intervention intervals. However, the average 11-12 measurements per day required can be a clini...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-020-00771-6

    authors: Uyttendaele V,Knopp JL,Shaw GM,Desaive T,Chase JG

    更新日期:2020-04-29 00:00:00

  • Hemodynamic effects of perfusion level of peripheral ECMO on cardiovascular system.

    abstract:BACKGROUND:Peripheral ECMO is an effective cardiopulmonary support in clinical. The perfusion level could directly influence the performances and complications. However, there are few studies on the effects of the perfusion level on hemodynamics of peripheral ECMO. METHODS:The geometric model of cardiovascular system ...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-018-0493-5

    authors: Gu K,Zhang Z,Gao B,Chang Y,Wan F

    更新日期:2018-05-09 00:00:00