Heart rate analysis in normal subjects of various age groups.

Abstract:

BACKGROUND:Analysis of heart rate variation (HRV) has become a popular noninvasive tool for assessing the activities of the autonomic nervous system (ANS). HRV analysis is based on the concept that fast fluctuations may specifically reflect changes of sympathetic and vagal activity. It shows that the structure generating the signal is not simply linear, but also involves nonlinear contributions. Linear parameters, Power spectral indice (LF/HF) is calculated with nonlinear indices Poincare plot geometry(SD1,SD2), Approximate Entropy (ApEn), Largest Lyapunov Exponent (LLE) and Detrended Fluctuation Analysis(DFA). The results show that, with aging the heart rate variability decreases. In this work, the ranges of all linear and nonlinear parameters for four age group normal subjects are presented with an accuracy of more than 89%. As a pre-analysis step, the HRV data is tested for nonlinearity using surrogate data analysis and the results exhibited a significant difference in the ApEn, LLE, SD1/SD2 and DFA parameters of the actual data and the surrogate data. METHODS:The heart rate is analyzed using the various time domain parameters, frequency domain parameter and nonlinear parameters like Poincare geometry, ApEn, LLE and DFA. RESULTS:In this work, the different linear and nonlinear parameters evaluated show a particular range for various cardiac abnormalities. And the results of these were subjected to 't' test with more than 89% confidence interval giving excellent 'p' values in all cases. CONCLUSIONS:Heart rate variability (HRV) signal can be used as a reliable indicator of state of the heart. It becomes less random with the aging(less chaotic). This is evaluated by using various time domain, frequency domain and nonlinear parameters like SD1/SD2, ApEn, LLE alphas and alphal. Different ranges of non-linear parameters for various age groups are presented with 'p' value < or = 0.12.

journal_name

Biomed Eng Online

authors

Acharya U R,Kannathal N,Sing OW,Ping LY,Chua T

doi

10.1186/1475-925X-3-24

keywords:

subject

Has Abstract

pub_date

2004-07-20 00:00:00

pages

24

issue

1

issn

1475-925X

pii

1475-925X-3-24

journal_volume

3

pub_type

杂志文章
  • Dendritic tree extraction from noisy maximum intensity projection images in C. elegans.

    abstract:BACKGROUND:Maximum Intensity Projections (MIP) of neuronal dendritic trees obtained from confocal microscopy are frequently used to study the relationship between tree morphology and mechanosensory function in the model organism C. elegans. Extracting dendritic trees from noisy images remains however a strenuous proces...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-13-74

    authors: Greenblum A,Sznitman R,Fua P,Arratia PE,Oren M,Podbilewicz B,Sznitman J

    更新日期:2014-06-12 00:00:00

  • Exploiting nonlinear recurrence and fractal scaling properties for voice disorder detection.

    abstract:BACKGROUND:Voice disorders affect patients profoundly, and acoustic tools can potentially measure voice function objectively. Disordered sustained vowels exhibit wide-ranging phenomena, from nearly periodic to highly complex, aperiodic vibrations, and increased "breathiness". Modelling and surrogate data studies have s...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-6-23

    authors: Little MA,McSharry PE,Roberts SJ,Costello DA,Moroz IM

    更新日期:2007-06-26 00:00:00

  • Neonatal non-contact respiratory monitoring based on real-time infrared thermography.

    abstract:BACKGROUND:Monitoring of vital parameters is an important topic in neonatal daily care. Progress in computational intelligence and medical sensors has facilitated the development of smart bedside monitors that can integrate multiple parameters into a single monitoring system. This paper describes non-contact monitoring...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-10-93

    authors: Abbas AK,Heimann K,Jergus K,Orlikowsky T,Leonhardt S

    更新日期:2011-10-20 00:00:00

  • Reducing the airflow waveform distortions from breathing style and body position with improved calibration of respiratory effort belts.

    abstract:BACKGROUND:Respiratory effort belt measurement is a widely used method to monitor respiration. Signal waveforms of respiratory volume and flow may indicate pathological signs of several diseases and, thus, it would be highly desirable to predict them accurately. Calibrated effort belts are sufficiently accurate for est...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-12-97

    authors: Seppänen TM,Alho OP,Seppänen T

    更新日期:2013-09-28 00:00:00

  • Correction to: Proposal of a new conceptual gait model for patients with Parkinson's disease based on factor analysis.

    abstract::It was highlighted that the original article [1] had an omission in the Abstract. This Correction article shows the omitted sentence: "This article [1] was awarded the SIAMOC Best Methodological Paper 2018". ...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章,已发布勘误

    doi:10.1186/s12938-019-0698-2

    authors: Arcolin I,Corna S,Giardini M,Giordano A,Nardone A,Godi M

    更新日期:2019-07-23 00:00:00

  • The effect of inlet and outlet boundary conditions in image-based CFD modeling of aortic flow.

    abstract:BACKGROUND:Computational modeling of cardiovascular flow is a growing and useful field, but such simulations usually require the researcher to guess the flow's inlet and outlet conditions since they are difficult and expensive to measure. It is critical to determine the amount of uncertainty introduced by these assumpt...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-018-0497-1

    authors: Madhavan S,Kemmerling EMC

    更新日期:2018-05-30 00:00:00

  • A perceptual map for gait symmetry quantification and pathology detection.

    abstract:BACKGROUND:The gait movement is an essential process of the human activity and the result of collaborative interactions between the neurological, articular and musculoskeletal systems, working efficiently together. This explains why gait analysis is important and increasingly used nowadays for the diagnosis of many dif...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-015-0097-2

    authors: Moevus A,Mignotte M,de Guise JA,Meunier J

    更新日期:2015-10-29 00:00:00

  • 3D marker-controlled watershed for kidney segmentation in clinical CT exams.

    abstract:BACKGROUND:Image segmentation is an essential and non trivial task in computer vision and medical image analysis. Computed tomography (CT) is one of the most accessible medical examination techniques to visualize the interior of a patient's body. Among different computer-aided diagnostic systems, the applications dedic...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-018-0456-x

    authors: Wieclawek W

    更新日期:2018-02-27 00:00:00

  • Fine-grain recordings of the electrically evoked compound action potential amplitude growth function in cochlear implant recipients.

    abstract:BACKGROUND:In cochlear implants (CI) measuring the electrically evoked compound action potential (ECAP) has become an important tool for verifying the electrode-nerve interface as well as establishing a basis for a map to program the speech processor. In a standard clinical setup recordings are averaged over 25-100 rep...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-018-0588-z

    authors: Gärtner L,Lenarz T,Büchner A

    更新日期:2018-10-19 00:00:00

  • Review of cognitive behavioural therapy mobile apps using a reference architecture embedded in the patient-provider relationship.

    abstract:BACKGROUND:Mobile health apps (mHealth apps) are increasing in popularity and utility for the management of many chronic diseases. Although the current reimbursement structure for mHealth apps is lagging behind the rapidly improving functionality, more clinicians will begin to recommend these apps as they prove their c...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-018-0611-4

    authors: Lan A,Lee A,Munroe K,McRae C,Kaleis L,Keshavjee K,Guergachi A

    更新日期:2018-12-17 00:00:00

  • Evaluation of needle movement effect on root canal irrigation using a computational fluid dynamics model.

    abstract:BACKGROUND:Irrigation is considered to be a critical part of root canal treatment. However, little is known about the effect of needle movement on the irrigation process. Therefore, this study aimed to investigate the influence of the syringe and needle movement on root canal irrigation using a three-dimensional comput...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-019-0679-5

    authors: Hu S,Duan L,Wan Q,Wang J

    更新日期:2019-05-06 00:00:00

  • Safety assessment of near infrared light emitting diodes for diffuse optical measurements.

    abstract:BACKGROUND:Near infrared (NIR) light has been used widely to monitor important hemodynamic parameters in tissue non-invasively. Pulse oximetry, near infrared spectroscopy, and diffuse optical tomography are examples of such NIR light-based applications. These and other similar applications employ either lasers or light...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-3-9

    authors: Bozkurt A,Onaral B

    更新日期:2004-03-22 00:00:00

  • In-vivo coronary flow profiling based on biplane angiograms: influence of geometric simplifications on the three-dimensional reconstruction and wall shear stress calculation.

    abstract:BACKGROUND:Clinical studies suggest that local wall shear stress (WSS) patterns modulate the site and the progression of atherosclerotic lesions. Computational fluid dynamics (CFD) methods based on in-vivo three-dimensional vessel reconstructions have recently been shown to provide prognostically relevant WSS data. Thi...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-5-39

    authors: Wellnhofer E,Goubergrits L,Kertzscher U,Affeld K

    更新日期:2006-06-14 00:00:00

  • Investigation of red blood cell mechanical properties using AFM indentation and coarse-grained particle method.

    abstract:BACKGROUND:Red blood cells (RBCs) deform significantly and repeatedly when passing through narrow capillaries and delivering dioxygen throughout the body. Deformability of RBCs is a key characteristic, largely governed by the mechanical properties of the cell membrane. This study investigated RBC mechanical properties ...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-017-0429-5

    authors: Barns S,Balanant MA,Sauret E,Flower R,Saha S,Gu Y

    更新日期:2017-12-19 00:00:00

  • The effect of baseline pressure errors on an intracranial pressure-derived index: results of a prospective observational study.

    abstract:BACKGROUND:In order to characterize the intracranial pressure-volume reserve capacity, the correlation coefficient (R) between the ICP wave amplitude (A) and the mean ICP level (P), the RAP index, has been used to improve the diagnostic value of ICP monitoring. Baseline pressure errors (BPEs), caused by spontaneous shi...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-13-99

    authors: Eide PK,Sorteberg A,Meling TR,Sorteberg W

    更新日期:2014-07-23 00:00:00

  • Respiratory sinus arrhythmia reactivity of internet addiction abusers in negative and positive emotional states using film clips stimulation.

    abstract:BACKGROUND AND AIMS:People with internet addiction (IA) suffer from mental, physical, social, and occupational problems. IA includes psychological and physiological syndromes, and among the syndromes, emotion was suggested important mental and physiological expressions of IA. However, few physiologically emotional char...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-016-0201-2

    authors: Hsieh DL,Hsiao TC

    更新日期:2016-07-04 00:00:00

  • S-EMG signal compression based on domain transformation and spectral shape dynamic bit allocation.

    abstract:BACKGROUND:Surface electromyographic (S-EMG) signal processing has been emerging in the past few years due to its non-invasive assessment of muscle function and structure and because of the fast growing rate of digital technology which brings about new solutions and applications. Factors such as sampling rate, quantiza...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-13-22

    authors: Trabuco MH,Costa MV,Nascimento FA

    更新日期:2014-02-27 00:00:00

  • Effect of glutaraldehyde based cross-linking on the viscoelasticity of mitral valve basal chordae tendineae.

    abstract:BACKGROUND:Mitral valve failure can require repair or replacement. Replacement bioprosthetic valves are treated with glutaraldehyde prior to implantation. The aim of this study was to determine the changes in mechanical properties following glutaraldehyde fixation of mitral valve chordae. METHODS:To investigate the im...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-018-0524-2

    authors: Constable M,Burton HE,Lawless BM,Gramigna V,Buchan KG,Espino DM

    更新日期:2018-07-13 00:00:00

  • Behavior of a viscoelastic valveless pump: a simple theory with experimental validation.

    abstract:BACKGROUND:A valveless pump generates a unidirectional net flow of fluid around a closed loop of soft viscoelastic tubing that is rhythmically compressed at one point. The tubing must have at least two sections with two different stiffnesses. When a short segment of the tube is squeezed asymmetrically at certain freque...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-9-42

    authors: Babbs CF

    更新日期:2010-08-31 00:00:00

  • NeoAnalysis: a Python-based toolbox for quick electrophysiological data processing and analysis.

    abstract:BACKGROUND:In a typical electrophysiological experiment, especially one that includes studying animal behavior, the data collected normally contain spikes, local field potentials, behavioral responses and other associated data. In order to obtain informative results, the data must be analyzed simultaneously with the ex...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-017-0419-7

    authors: Zhang B,Dai J,Zhang T

    更新日期:2017-11-13 00:00:00

  • A portable system with sample rate of 250 Hz for characterization of knee and hip angles in the sagittal plane during gait.

    abstract:BACKGROUND:Gait analysis and research have been developed to obtain characteristics of movement patterns of people while walking. However, traditional measuring systems present different drawbacks that reduce their use and application. Among those drawbacks one can find: high price, low sampling frequency and limiting ...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-13-34

    authors: Martínez-Solís F,Claudio-Sánchez A,Rodríguez-Lelis JM,Vergara-Limon S,Olivares-Peregrino V,Vargas-Treviño M

    更新日期:2014-03-31 00:00:00

  • Artery buckling affects the mechanical stress in atherosclerotic plaques.

    abstract:BACKGROUND:Tortuous arteries are often seen in patients with hypertension and atherosclerosis. While the mechanical stress in atherosclerotic plaque under lumen pressure has been studied extensively, the mechanical stability of atherosclerotic arteries and subsequent effect on the plaque stress remain unknown. To this ...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-14-S1-S4

    authors: Sanyal A,Han HC

    更新日期:2015-01-01 00:00:00

  • A reconfigurable arbitrary waveform generator using PWM modulation for ultrasound research.

    abstract:BACKGROUND:In ultrasound imaging systems, the digital transmit beamformer is a critical module that generates accurate control over several transmission parameters. However, such transmit front-end module is not typically accessible to ultrasound researchers. To overcome this difficulty, we have been developing a compa...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-12-24

    authors: Assef AA,Maia JM,Schneider FK,Button VL,Costa ET

    更新日期:2013-03-20 00:00:00

  • Cardiac arrhythmia classification using autoregressive modeling.

    abstract:BACKGROUND:Computer-assisted arrhythmia recognition is critical for the management of cardiac disorders. Various techniques have been utilized to classify arrhythmias. Generally, these techniques classify two or three arrhythmias or have significantly large processing times. A simpler autoregressive modeling (AR) techn...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925x-1-5

    authors: Ge D,Srinivasan N,Krishnan SM

    更新日期:2002-11-13 00:00:00

  • 3-Dimensional printing in rehabilitation: feasibility of printing an upper extremity gross motor function assessment tool.

    abstract:BACKGROUND:Use of standardized and scientifically sound outcome measures is encouraged in clinical practice and research. With the development of newer rehabilitation therapies, we need technology-supported upper extremity outcome measures that are easily accessible, reliable and valid. 3-Dimensional printing (3D-print...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-020-00839-3

    authors: Kapadia N,Myers M,Musselman K,Wang RH,Yurkewich A,Popovic MR

    更新日期:2021-01-05 00:00:00

  • 16-Channel biphasic current-mode programmable charge balanced neural stimulation.

    abstract:BACKGROUND:Neural stimulation is an important method used to activate or inhibit action potentials of the neuronal anatomical targets found in the brain, central nerve and peripheral nerve. The neural stimulator system produces biphasic pulses that deliver balanced charge into tissue from single or multichannel electro...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-017-0385-0

    authors: Li X,Zhong S,Morizio J

    更新日期:2017-08-14 00:00:00

  • Characterization of the head-to-trunk orientation with handheld optical 3D apparatus based on the fringe projection technique.

    abstract:BACKGROUND:Knowing the orientation of the head is important in many fields, including medicine. Many methods and measuring systems exist, but usually they use different markers or sensors attached to the subject's head for head orientation determination. In certain applications these attachments may represent a burden ...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-12-96

    authors: Pavlovčič U,Diaci J,Možina J,Jezeršek M

    更新日期:2013-09-26 00:00:00

  • An improved level set method for vertebra CT image segmentation.

    abstract:BACKGROUND:Clinical diagnosis and therapy for the lumbar disc herniation requires accurate vertebra segmentation. The complex anatomical structure and the degenerative deformations of the vertebrae makes its segmentation challenging. METHODS:An improved level set method, namely edge- and region-based level set method ...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-12-48

    authors: Huang J,Jian F,Wu H,Li H

    更新日期:2013-05-28 00:00:00

  • Computational studies of the effects of myocardial blood flow reductions on cardiac metabolism.

    abstract:BACKGROUND:A computational model of myocardial energy metabolism was used to assess the metabolic responses to normal and reduced myocardial blood flow. The goal was to examine to what extent glycolysis and lactate formation are controlled by the supply of glycolytic substrate and/or the cellular redox (NADH/NAD+) and ...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-3-15

    authors: Salem JE,Stanley WC,Cabrera ME

    更新日期:2004-06-02 00:00:00

  • Low-cost equipment for the evaluation of reach and grasp in post-stroke individuals: a pilot study.

    abstract:BACKGROUND:Reach-grasp movements are motor components commonly affected after stroke and directly related to the independence of these individuals. Evaluations of these activities can be performed using clinical instruments and assessed by detailed and costly kinematic analyses. The aim of this study was to develop an ...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-020-0758-7

    authors: Gomes CLA,Cacho RO,Nobrega VTB,de A Confessor EM,de Farias EEM,Neto JLF,de Araújo DS,de S Medeiros AL,Barreto RL,Cacho EWA

    更新日期:2020-03-04 00:00:00