Possibility of reconstruction of dental plaster cast from 3D digital study models.

Abstract:

OBJECTIVES:To compare traditional plaster casts, digital models and 3D printed copies of dental plaster casts based on various criteria. To determine whether 3D printed copies obtained using open source system RepRap can replace traditional plaster casts in dental practice. To compare and contrast the qualities of two possible 3D printing options--source system RepRap and commercially available 3D printing. DESIGN AND SETTINGS:A method comparison study on 10 dental plaster casts from the Orthodontic department, Department of Stomatology, 2nd medical Faulty, Charles University Prague, Czech Republic. MATERIAL AND METHODS:Each of 10 plaster casts were scanned by inEos Blue scanner and the printed on 3D printer RepRap [10 models] and ProJet HD3000 3D printer [1 model]. Linear measurements between selected points on the dental arches of upper and lower jaws on plaster casts and its 3D copy were recorded and statistically analyzed. RESULTS:3D printed copies have many advantages over traditional plaster casts. The precision and accuracy of the RepRap 3D printed copies of plaster casts were confirmed based on the statistical analysis. Although the commercially available 3D printing enables to print more details than the RepRap system, it is expensive and for the purpose of clinical use can be replaced by the cheaper prints obtained from RepRap printed copies. CONCLUSIONS:Scanning of the traditional plaster casts to obtain a digital model offers a pragmatic approach. The scans can subsequently be used as a template to print the plaster casts as required. Using 3D printers can replace traditional plaster casts primarily due to their accuracy and price.

journal_name

Biomed Eng Online

authors

Kasparova M,Grafova L,Dvorak P,Dostalova T,Prochazka A,Eliasova H,Prusa J,Kakawand S

doi

10.1186/1475-925X-12-49

subject

Has Abstract

pub_date

2013-05-31 00:00:00

pages

49

issn

1475-925X

pii

1475-925X-12-49

journal_volume

12

pub_type

杂志文章
  • Novel dynamic corneal response parameters in a practice use: a critical review.

    abstract:BACKGROUND:Non-contact tonometers based on the method using air puff and Scheimpflug's fast camera are one of the latest devices allowing the measurement of intraocular pressure and additional biomechanical parameters of the cornea. Biomechanical features significantly affect changes in intraocular pressure values, as ...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章,评审

    doi:10.1186/s12938-019-0636-3

    authors: Jędzierowska M,Koprowski R

    更新日期:2019-02-13 00:00:00

  • The effect of baseline pressure errors on an intracranial pressure-derived index: results of a prospective observational study.

    abstract:BACKGROUND:In order to characterize the intracranial pressure-volume reserve capacity, the correlation coefficient (R) between the ICP wave amplitude (A) and the mean ICP level (P), the RAP index, has been used to improve the diagnostic value of ICP monitoring. Baseline pressure errors (BPEs), caused by spontaneous shi...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-13-99

    authors: Eide PK,Sorteberg A,Meling TR,Sorteberg W

    更新日期:2014-07-23 00:00:00

  • Multi-objective optimization of coronary stent using Kriging surrogate model.

    abstract:BACKGROUND:In stent design optimization, the functional relationship between design parameters and design goals is nonlinear, complex, and implicit and the multi-objective design of stents involves a number of potentially conflicting performance criteria. Therefore it is hard and time-consuming to find the optimal desi...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-016-0268-9

    authors: Li H,Gu J,Wang M,Zhao D,Li Z,Qiao A,Zhu B

    更新日期:2016-12-28 00:00:00

  • Telepointer technology in telemedicine: a review.

    abstract::Telepointer is a powerful tool in the telemedicine system that enhances the effectiveness of long-distance communication. Telepointer has been tested in telemedicine, and has potential to a big influence in improving quality of health care, especially in the rural area. A telepointer system works by sending additional...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章,评审

    doi:10.1186/1475-925X-12-21

    authors: Abdul Karim R,Zakaria NF,Zulkifley MA,Mustafa MM,Sagap I,Md Latar NH

    更新日期:2013-03-09 00:00:00

  • Theoretical modeling for radiofrequency ablation: state-of-the-art and challenges for the future.

    abstract::Radiofrequency ablation is an interventional technique that in recent years has come to be employed in very different medical fields, such as the elimination of cardiac arrhythmias or the destruction of tumors in different locations. In order to investigate and develop new techniques, and also to improve those current...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章,评审

    doi:10.1186/1475-925X-5-24

    authors: Berjano EJ

    更新日期:2006-04-18 00:00:00

  • Quantification of functional hand grip using electromyography and inertial sensor-derived accelerations: clinical implications.

    abstract:BACKGROUND:Assessing hand injury is of great interest given the level of involvement of the hand with the environment. Knowing different assessment systems and their limitations generates new perspectives. The integration of digital systems (accelerometry and electromyography) as a tool to supplement functional assessm...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-13-161

    authors: Martin-Martin J,Cuesta-Vargas AI

    更新日期:2014-12-11 00:00:00

  • Biomechanical simulation of thorax deformation using finite element approach.

    abstract:BACKGROUND:The biomechanical simulation of the human respiratory system is expected to be a useful tool for the diagnosis and treatment of respiratory diseases. Because the deformation of the thorax significantly influences airflow in the lungs, we focused on simulating the thorax deformation by introducing contraction...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-016-0132-y

    authors: Zhang G,Chen X,Ohgi J,Miura T,Nakamoto A,Matsumura C,Sugiura S,Hisada T

    更新日期:2016-02-06 00:00:00

  • Respiratory sinus arrhythmia reactivity of internet addiction abusers in negative and positive emotional states using film clips stimulation.

    abstract:BACKGROUND AND AIMS:People with internet addiction (IA) suffer from mental, physical, social, and occupational problems. IA includes psychological and physiological syndromes, and among the syndromes, emotion was suggested important mental and physiological expressions of IA. However, few physiologically emotional char...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-016-0201-2

    authors: Hsieh DL,Hsiao TC

    更新日期:2016-07-04 00:00:00

  • Assessment of nonnegative matrix factorization algorithms for electroencephalography spectral analysis.

    abstract:BACKGROUND:Nonnegative matrix factorization (NMF) has been successfully used for electroencephalography (EEG) spectral analysis. Since NMF was proposed in the 1990s, many adaptive algorithms have been developed. However, the performance of their use in EEG data analysis has not been fully compared. Here, we provide a c...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-020-00796-x

    authors: Hu G,Zhou T,Luo S,Mahini R,Xu J,Chang Y,Cong F

    更新日期:2020-07-31 00:00:00

  • Extraction of average neck flexion angle during swallowing in neutral and chin-tuck positions.

    abstract:BACKGROUND:A common but debated technique in the management of swallowing difficulties is the chin tuck swallow, where the neck is flexed forward prior to swallowing. Natural variations in chin tuck angles across individuals may contribute to the differential effectiveness of the technique. METHODOLOGY:To facilitate t...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-8-25

    authors: Hung D,Sejdić E,Steele CM,Chau T

    更新日期:2009-10-07 00:00:00

  • Hemodynamic numerical simulations of the disturbance due to intracoronary flow measurements by a Doppler guide wire.

    abstract:BACKGROUND:Since hemodynamics plays a key role in the development and evolution of cardiovascular pathologies, physician's decision must be based on proper monitoring of relevant physiological flow quantities. METHODS:A numerical analysis of the error introduced by an intravascular Doppler guide wire on the peak veloc...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-016-0234-6

    authors: Chodzyński KJ,Gremmo S,Eker OF,Lalmand J,Aminian A,de Sousa DR,Boudjeltia KZ,Coussement G

    更新日期:2016-10-10 00:00:00

  • Determination of detection depth of optical probe in pedicle screw measurement device.

    abstract:BACKGROUND:There is a high probability of accidental perforation of the vertebral pedicle wall in pedicle screw insertion surgery. A pedicle screw (PS) measurement device with an optical probe has been reported to send out a warning signal before the PS tip breaking the vertebral pedicle wall. METHODS:In this study, w...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-13-148

    authors: Li W,Liu Y,Qian Z

    更新日期:2014-11-01 00:00:00

  • Examination of ceramic restoration adhesive coverage in cusp-replacement premolar using acoustic emission under fatigue testing.

    abstract:BACKGROUND:This study investigates CAD/CAM ceramic cusp-replacing restoration resistance with and without buccal cusp replacement under static and dynamic cyclic loads, monitored using the acoustic emission (AE) technique. METHOD:The cavity was designed in a typical MODP (mesial-occlusal-distal-palatal) restoration fa...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-13-165

    authors: Chang YH,Yu JJ,Lin CL

    更新日期:2014-12-13 00:00:00

  • Study of probe-sample distance for biomedical spectra measurement.

    abstract:BACKGROUND:Fiber-based optical spectroscopy has been widely used for biomedical applications. However, the effect of probe-sample distance on the collection efficiency has not been well investigated. METHOD:In this paper, we presented a theoretical model to maximize the illumination and collection efficiency in design...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-10-95

    authors: Wang B,Fan S,Li L,Wang C

    更新日期:2011-11-02 00:00:00

  • A computational model study of the influence of the anatomy of the circle of willis on cerebral hyperperfusion following carotid artery surgery.

    abstract:BACKGROUND:Cerebral hyperperfusion syndrome develops in a small subset of patients following carotid artery surgery (CAS) performed to treat severe carotid artery stenosis. This syndrome has been found to have a close correlation with cerebral hyperperfusion occurring after CAS. The purpose of this study is to investig...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-10-84

    authors: Liang F,Fukasaku K,Liu H,Takagi S

    更新日期:2011-09-23 00:00:00

  • Mechanical strain promotes osteoblast ECM formation and improves its osteoinductive potential.

    abstract:BACKGROUND:The extracellular matrix (ECM) provides a supportive microenvironment for cells, which is suitable as a tissue engineering scaffold. Mechanical stimulus plays a significant role in the fate of osteoblast, suggesting that it regulates ECM formation. Therefore, we investigated the influence of mechanical stimu...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-11-80

    authors: Guo Y,Zhang CQ,Zeng QC,Li RX,Liu L,Hao QX,Shi CH,Zhang XZ,Yan YX

    更新日期:2012-10-25 00:00:00

  • In vivo and in vitro performance of a China-made hemodialysis machine: a multi-center prospective controlled study.

    abstract:OBJECTIVE:To evaluate the in vivo and in vitro performance of a China-made dialysis machine (SWS-4000). METHODS:This was a multi-center prospective controlled study consisting of both long-term in vitro evaluations and cross-over in vivo tests in 132 patients. The China-made SWS-4000 dialysis machine was compared with...

    journal_title:Biomedical engineering online

    pub_type: 临床试验,杂志文章,多中心研究

    doi:10.1186/s12938-017-0387-y

    authors: Wang Y,Chen XM,Cai GY,Li WG,Zhang AH,Hao LR,Shi M,Wang R,Jiang HL,Luo HM,Zhang D,Sun XF

    更新日期:2017-08-02 00:00:00

  • Prospects of implant with locking plate in fixation of subtrochanteric fracture: experimental demonstration of its potential benefits on synthetic femur model with supportive hierarchical nonlinear hyperelastic finite element analysis.

    abstract:BACKGROUND:Effective fixation of fracture requires careful selection of a suitable implant to provide stability and durability. Implant with a feature of locking plate (LP) has been used widely for treating distal fractures in femur because of its favourable clinical outcome, but its potential in fixing proximal fractu...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-11-23

    authors: Latifi MH,Ganthel K,Rukmanikanthan S,Mansor A,Kamarul T,Bilgen M

    更新日期:2012-04-30 00:00:00

  • A perceptual map for gait symmetry quantification and pathology detection.

    abstract:BACKGROUND:The gait movement is an essential process of the human activity and the result of collaborative interactions between the neurological, articular and musculoskeletal systems, working efficiently together. This explains why gait analysis is important and increasingly used nowadays for the diagnosis of many dif...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-015-0097-2

    authors: Moevus A,Mignotte M,de Guise JA,Meunier J

    更新日期:2015-10-29 00:00:00

  • Developing functional workspace for the movement of trunk circumduction in healthy young subjects: a reliability study.

    abstract:BACKGROUND:The lumbar range of motion has traditionally been used to assess disability in patients with low back disorders. Controversy exists about how movement ranges in static positions or in a single straight plane is related to the functional status of the patients. The trunk circumduction, as the result of neurom...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-12-4

    authors: Cheng SC,Hsu CH,Ting YT,Kuo LC,Lin RM,Su FC

    更新日期:2013-01-11 00:00:00

  • In memorium: Herman p. Schwan [1915-2005].

    abstract::Herman P. Schwan [1915-2005] was a distinguished scientist and engineer, and a founding father of the field of biomedical engineering. A man of integrity, Schwan influenced the lives of many, including his wife and children, and his many students and colleagues. Active in science until nearly the end of his life, he w...

    journal_title:Biomedical engineering online

    pub_type: 传,历史文章,杂志文章

    doi:10.1186/1475-925X-4-21

    authors: Foster KR

    更新日期:2005-03-25 00:00:00

  • Performance evaluation of a motor-imagery-based EEG-Brain computer interface using a combined cue with heterogeneous training data in BCI-Naive subjects.

    abstract:BACKGROUND:The subjects in EEG-Brain computer interface (BCI) system experience difficulties when attempting to obtain the consistent performance of the actual movement by motor imagery alone. It is necessary to find the optimal conditions and stimuli combinations that affect the performance factors of the EEG-BCI syst...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-10-91

    authors: Choi D,Ryu Y,Lee Y,Lee M

    更新日期:2011-10-12 00:00:00

  • Classification of voice disorder in children with cochlear implantation and hearing aid using multiple classifier fusion.

    abstract:BACKGROUND:Speech production and speech phonetic features gradually improve in children by obtaining audio feedback after cochlear implantation or using hearing aids. The aim of this study was to develop and evaluate automated classification of voice disorder in children with cochlear implantation and hearing aids. ME...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-10-3

    authors: Mahmoudi Z,Rahati S,Ghasemi MM,Asadpour V,Tayarani H,Rajati M

    更新日期:2011-01-14 00:00:00

  • Automatic lumen segmentation in IVOCT images using binary morphological reconstruction.

    abstract:BACKGROUND:Atherosclerosis causes millions of deaths, annually yielding billions in expenses round the world. Intravascular Optical Coherence Tomography (IVOCT) is a medical imaging modality, which displays high resolution images of coronary cross-section. Nonetheless, quantitative information can only be obtained with...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-12-78

    authors: Moraes MC,Cardenas DA,Furuie SS

    更新日期:2013-08-09 00:00:00

  • Designing and testing scene enhancement algorithms for patients with retina degenerative disorders.

    abstract:BACKGROUND:Retina degenerative disorders represent the primary cause of blindness in UK and in the developed world. In particular, Age Related Macular Degeneration (AMD) and Retina Pigmentosa (RP) diseases are of interest to this study. We have therefore created new image processing algorithms for enhancing the visual ...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-9-27

    authors: Al-Atabany WI,Memon MA,Downes SM,Degenaar PA

    更新日期:2010-06-18 00:00:00

  • Open source model for generating RR intervals in atrial fibrillation and beyond.

    abstract:BACKGROUND:Realistic modeling of cardiac inter-beat (RR) intervals is highly desirable for basic research in cardiac electrophysiology, clinical management of heart diseases, and developing signal processing tools for ECG analysis. METHODS:We present an open source computer model that is capable to generate realistic ...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-6-9

    authors: Lian J,Clifford GD,Müssig D,Lang V

    更新日期:2007-03-02 00:00:00

  • Effect of pressure and padding on motion artifact of textile electrodes.

    abstract:BACKGROUND:With the aging population and rising healthcare costs, wearable monitoring is gaining importance. The motion artifact affecting dry electrodes is one of the main challenges preventing the widespread use of wearable monitoring systems. In this paper we investigate the motion artifact and ways of making a text...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-12-26

    authors: Cömert A,Honkala M,Hyttinen J

    更新日期:2013-04-08 00:00:00

  • Low-dose CT reconstruction via L1 dictionary learning regularization using iteratively reweighted least-squares.

    abstract:BACKGROUND:In order to reduce the radiation dose of CT (computed tomography), compressed sensing theory has been a hot topic since it provides the possibility of a high quality recovery from the sparse sampling data. Recently, the algorithm based on DL (dictionary learning) was developed to deal with the sparse CT reco...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-016-0193-y

    authors: Zhang C,Zhang T,Li M,Peng C,Liu Z,Zheng J

    更新日期:2016-06-18 00:00:00

  • Translational-circular scanning for magneto-acoustic tomography with current injection.

    abstract:BACKGROUND:Magneto-acoustic tomography with current injection involves using electrical impedance imaging technology. To explore the potential applications in imaging biological tissue and enhance image quality, a new scan mode for the transducer is proposed that is based on translational and circular scanning to recor...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-016-0125-x

    authors: Wang S,Ma R,Zhang S,Yin T,Liu Z

    更新日期:2016-01-27 00:00:00

  • Computational and experimental assessment of influences of hemodynamic shear stress on carotid plaque.

    abstract:BACKGROUND:Studies have identified hemodynamic shear stress as an important determinant of endothelial function and atherosclerosis. In this study, we assess the influences of hemodynamic shear stress on carotid plaques. METHODS:Carotid stenosis phantoms with three severity (30, 50, 70%) were made from 10% polyvinyl a...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-017-0386-z

    authors: Zhou H,Meng L,Zhou W,Xin L,Xia X,Li S,Zheng H,Niu L

    更新日期:2017-07-29 00:00:00