Low-cost equipment for the evaluation of reach and grasp in post-stroke individuals: a pilot study.

Abstract:

BACKGROUND:Reach-grasp movements are motor components commonly affected after stroke and directly related to the independence of these individuals. Evaluations of these activities can be performed using clinical instruments and assessed by detailed and costly kinematic analyses. The aim of this study was to develop an analysis of reach-grasp movements in post-stroke patients using a simple, inexpensive, and manageable instrument. RESULTS:A Mann-Whitney test was used to compare paretic and non-paretic limb motor performance. A statistically significant difference was found between the variables of total time (p = 0.02) and speed to reach target 3 (p = 0.04) for task 1, while in task 2 significance was found only in the aspect of speed to reach target 2 (p = 0.04). The correlation between clinical tests and variables of tasks was then performed using Spearman's rank correlation coefficient. At task 1, when compared with the REACH instrument, the close target sub-item; there was a high positive correlation between the parameters of total time (p = 0.028), target velocity 3 (p = 0.028), and target acceleration 3 (p = 0.028). Another instrument that showed a high positive correlation with the target time 3 (p = 0.01) and target acceleration 3 (p = 0.028) variables was the Box and Block Test. When correlated, the data between the task 2 variables and clinical instruments did not present statistically significant data. CONCLUSION:Our instrument-the Temporal Data Acquisition Instrument-TDAI-fulfilled the expected objectives and can be used as an option to evaluate the movements of reach and grasp of upper limb post-stroke, using an easy and fast application, without the need for calibration. Trial registration Trial Registration: Research Ethics Committee of the Trairi School of Health Sciences-Number 2.625.609, approved on April 13, 2018; Brazilian Registry of Clinical Trials-RBR-4995cr approved on July 4, 2019 retrospectively registered (http://www.ensaiosclinicos.gov.br/rg/RBR-4995cr/).

journal_name

Biomed Eng Online

authors

Gomes CLA,Cacho RO,Nobrega VTB,de A Confessor EM,de Farias EEM,Neto JLF,de Araújo DS,de S Medeiros AL,Barreto RL,Cacho EWA

doi

10.1186/s12938-020-0758-7

subject

Has Abstract

pub_date

2020-03-04 00:00:00

pages

14

issue

1

issn

1475-925X

pii

10.1186/s12938-020-0758-7

journal_volume

19

pub_type

杂志文章
  • Evaluation of flow changes after telescopic stenting of a giant fusiform aneurysm of the vertebrobasilar junction.

    abstract:BACKGROUND:The use of flow-diverters for non-saccular cerebral posterior circulation aneurysms requires complex deployment techniques and is associated with high mortality and morbidity. Therefore, further studies are required to clarify the effect of stenting on post-treatment hemodynamics in such aneurysms. In this s...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-019-0699-1

    authors: Sindeev S,Kirschke JS,Prothmann S,Frolov S,Liepsch D,Berg P,Zimmer C,Friedrich B

    更新日期:2019-07-24 00:00:00

  • Investigations concerning the application of the cross-correlation method in cardiac output measurements.

    abstract:BACKGROUND:In spite of numerous non-invasive examinations the "gold clinical standard" of cardiac output measurements is the invasive pulmonary artery catheterization by means of the Swan-Ganz catheter and the application of the thermodilution method to estimate the blood flow. The results obtained by means of thermodi...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-11-24

    authors: Gawlikowski M,Pustelny T

    更新日期:2012-05-20 00:00:00

  • Assessment of significance of features acquired from thyroid ultrasonograms in Hashimoto's disease.

    abstract:INTRODUCTION:This paper concerns the analysis of the features obtained from thyroid ultrasound images in left and right transverse and longitudinal sections. In the image analysis, the thyroid lobe is treated as a texture for healthy subjects and patients with Hashimoto's disease. The applied methods of analysis and im...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-11-48

    authors: Koprowski R,Zieleźnik W,Wróbel Z,Małyszek J,Stępień B,Wójcik W

    更新日期:2012-08-16 00:00:00

  • Blood pressure waveform contour analysis for assessing peripheral resistance changes in sepsis.

    abstract:BACKGROUND:This paper proposes a methodology for helping bridge the gap between the complex waveform information frequently available in an intensive care unit and the simple, lumped values favoured for rapid clinical diagnosis and management. This methodology employs a simple waveform contour analysis approach to comp...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-018-0603-4

    authors: Davidson S,Pretty C,Balmer J,Desaive T,Chase JG

    更新日期:2018-11-20 00:00:00

  • Comparison of named entity recognition methodologies in biomedical documents.

    abstract:BACKGROUND:Biomedical named entity recognition (Bio-NER) is a fundamental task in handling biomedical text terms, such as RNA, protein, cell type, cell line, and DNA. Bio-NER is one of the most elementary and core tasks in biomedical knowledge discovery from texts. The system described here is developed by using the Bi...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-018-0573-6

    authors: Song HJ,Jo BC,Park CY,Kim JD,Kim YS

    更新日期:2018-11-06 00:00:00

  • Review of cognitive behavioural therapy mobile apps using a reference architecture embedded in the patient-provider relationship.

    abstract:BACKGROUND:Mobile health apps (mHealth apps) are increasing in popularity and utility for the management of many chronic diseases. Although the current reimbursement structure for mHealth apps is lagging behind the rapidly improving functionality, more clinicians will begin to recommend these apps as they prove their c...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-018-0611-4

    authors: Lan A,Lee A,Munroe K,McRae C,Kaleis L,Keshavjee K,Guergachi A

    更新日期:2018-12-17 00:00:00

  • Challenges, issues and trends in fall detection systems.

    abstract::Since falls are a major public health problem among older people, the number of systems aimed at detecting them has increased dramatically over recent years. This work presents an extensive literature review of fall detection systems, including comparisons among various kinds of studies. It aims to serve as a referenc...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章,评审

    doi:10.1186/1475-925X-12-66

    authors: Igual R,Medrano C,Plaza I

    更新日期:2013-07-06 00:00:00

  • Novel dynamic corneal response parameters in a practice use: a critical review.

    abstract:BACKGROUND:Non-contact tonometers based on the method using air puff and Scheimpflug's fast camera are one of the latest devices allowing the measurement of intraocular pressure and additional biomechanical parameters of the cornea. Biomechanical features significantly affect changes in intraocular pressure values, as ...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章,评审

    doi:10.1186/s12938-019-0636-3

    authors: Jędzierowska M,Koprowski R

    更新日期:2019-02-13 00:00:00

  • A specialized motion capture system for real-time analysis of mandibular movements using infrared cameras.

    abstract:BACKGROUND:In the last years, several methods and devices have been proposed to record the human mandibular movements, since they provide quantitative parameters that support the diagnosis and treatment of temporomandibular disorders. The techniques currently employed suffer from a number of drawbacks including high pr...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-12-17

    authors: Furtado DA,Pereira AA,Andrade Ade O,Bellomo DP Jr,da Silva MR

    更新日期:2013-02-22 00:00:00

  • The effect of baseline pressure errors on an intracranial pressure-derived index: results of a prospective observational study.

    abstract:BACKGROUND:In order to characterize the intracranial pressure-volume reserve capacity, the correlation coefficient (R) between the ICP wave amplitude (A) and the mean ICP level (P), the RAP index, has been used to improve the diagnostic value of ICP monitoring. Baseline pressure errors (BPEs), caused by spontaneous shi...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-13-99

    authors: Eide PK,Sorteberg A,Meling TR,Sorteberg W

    更新日期:2014-07-23 00:00:00

  • A comparative study of reaction times between type II diabetics and non-diabetics.

    abstract:BACKGROUND:Aging has been shown to slow reflexes and increase reaction time to varied stimuli. However, the effect of Type II diabetes on these same reaction times has not been reported. Diabetes affects peripheral nerves in the somatosensory and auditory system, slows psychomotor responses, and has cognitive effects o...

    journal_title:Biomedical engineering online

    pub_type: 临床试验,杂志文章

    doi:10.1186/1475-925X-4-12

    authors: Richerson SJ,Robinson CJ,Shum J

    更新日期:2005-02-21 00:00:00

  • Collaborative and secure transmission of medical data applied to mobile healthcare.

    abstract:PURPOSE:We propose a collaborative and secure transmission scheme in order to safely and efficiently transmit medical data and provide telemedicine services, lighten the load on wireless access networks, and improve the quality of medical treatment such as surgery. METHODS:First, the transmission technology based on o...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-019-0674-x

    authors: Chen W,Chen Z,Cui F

    更新日期:2019-05-20 00:00:00

  • Study of probe-sample distance for biomedical spectra measurement.

    abstract:BACKGROUND:Fiber-based optical spectroscopy has been widely used for biomedical applications. However, the effect of probe-sample distance on the collection efficiency has not been well investigated. METHOD:In this paper, we presented a theoretical model to maximize the illumination and collection efficiency in design...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-10-95

    authors: Wang B,Fan S,Li L,Wang C

    更新日期:2011-11-02 00:00:00

  • The effect of novel nitrogen-rich plasma polymer coatings on the phenotypic profile of notochordal cells.

    abstract:BACKGROUND:The loss of the notochordal cells from the nucleus pulposus is associated with ageing and disc degeneration. However, understanding the mechanisms responsible for the loss of these cells has been hampered in part due to the difficulty of culturing and maintaining their phenotype. Furthermore, little is known...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-6-33

    authors: Mwale F,Wang HT,Petit A,Girard-Lauriault PL,Hunter CJ,Ouellet JA,Wertheimer MR,Antoniou J

    更新日期:2007-09-06 00:00:00

  • Motor recovery monitoring using acceleration measurements in post acute stroke patients.

    abstract:BACKGROUND:Stroke is one of the major causes of morbidity and mortality. Its recovery and treatment depends on close clinical monitoring by a clinician especially during the first few hours after the onset of stroke. Patients who do not exhibit early motor recovery post thrombolysis may benefit from more aggressive tre...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-12-33

    authors: Gubbi J,Rao AS,Fang K,Yan B,Palaniswami M

    更新日期:2013-04-16 00:00:00

  • Human coronary plaque wall thickness correlated positively with flow shear stress and negatively with plaque wall stress: an IVUS-based fluid-structure interaction multi-patient study.

    abstract:BACKGROUND:Atherosclerotic plaque progression and rupture are believed to be associated with mechanical stress conditions. In this paper, patient-specific in vivo intravascular ultrasound (IVUS) coronary plaque image data were used to construct computational models with fluid-structure interaction (FSI) and cyclic bend...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-13-32

    authors: Fan R,Tang D,Yang C,Zheng J,Bach R,Wang L,Muccigrosso D,Billiar K,Zhu J,Ma G,Maehara A,Mintz GS

    更新日期:2014-03-26 00:00:00

  • Study on the biomechanical responses of the loaded bone in macroscale and mesoscale by multiscale poroelastic FE analysis.

    abstract:BACKGROUND:Bone is a hierarchically structured composite material, and different hierarchical levels exhibit diverse material properties and functions. The stress and strain distribution and fluid flow in bone play an important role in the realization of mechanotransduction and bone remodeling. METHODS:To investigate ...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-019-0741-3

    authors: Yu W,Wu X,Cen H,Guo Y,Li C,Wang Y,Qin Y,Chen W

    更新日期:2019-12-23 00:00:00

  • Automatic QRS complex detection using two-level convolutional neural network.

    abstract:BACKGROUND:The QRS complex is the most noticeable feature in the electrocardiogram (ECG) signal, therefore, its detection is critical for ECG signal analysis. The existing detection methods largely depend on hand-crafted manual features and parameters, which may introduce significant computational complexity, especiall...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-018-0441-4

    authors: Xiang Y,Lin Z,Meng J

    更新日期:2018-01-29 00:00:00

  • In vivo long-term investigation of tumor bearing mKate2 by an in-house fluorescence molecular imaging system.

    abstract:BACKGROUND:Optical imaging is one of the most common, low-cost imaging tools used for investigating the tumor biological behavior in vivo. This study explores the feasibility and sensitivity of a near infrared fluorescent protein mKate2 for a long-term non-invasive tumor imaging in BALB/c nude mice, by using a low-powe...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-018-0615-0

    authors: Zhou K,Ding Y,Vuletic I,Tian Y,Li J,Liu J,Huang Y,Sun H,Li C,Ren Q,Lu Y

    更新日期:2018-12-29 00:00:00

  • Influence of model boundary conditions on blood flow patterns in a patient specific stenotic right coronary artery.

    abstract:BACKGROUND:In literature, the effect of the inflow boundary condition was investigated by examining the impact of the waveform and the shape of the spatial profile of the inlet velocity on the cardiac hemodynamics. However, not much work has been reported on comparing the effect of the different combinations of the inl...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-14-S1-S6

    authors: Liu B,Zheng J,Bach R,Tang D

    更新日期:2015-01-01 00:00:00

  • Two-hierarchical nonnegative matrix factorization distinguishing the fluorescent targets from autofluorescence for fluorescence imaging.

    abstract:BACKGROUND:Nonnegative matrix factorization (NMF) has been used in blind fluorescence unmixing for multispectral in-vivo fluorescence imaging, which decomposes a mixed source data into a set of constituent fluorescence spectra and corresponding concentrations. However, most classical NMF algorithms have ill convergence...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-015-0107-4

    authors: Huang S,Zhao Y,Qin B

    更新日期:2015-12-15 00:00:00

  • Theoretical modeling for radiofrequency ablation: state-of-the-art and challenges for the future.

    abstract::Radiofrequency ablation is an interventional technique that in recent years has come to be employed in very different medical fields, such as the elimination of cardiac arrhythmias or the destruction of tumors in different locations. In order to investigate and develop new techniques, and also to improve those current...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章,评审

    doi:10.1186/1475-925X-5-24

    authors: Berjano EJ

    更新日期:2006-04-18 00:00:00

  • Microneurography as a tool to develop decoding algorithms for peripheral neuro-controlled hand prostheses.

    abstract:BACKGROUND:The usability of dexterous hand prostheses is still hampered by the lack of natural and effective control strategies. A decoding strategy based on the processing of descending efferent neural signals recorded using peripheral neural interfaces could be a solution to such limitation. Unfortunately, this choic...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-019-0659-9

    authors: Petrini FM,Mazzoni A,Rigosa J,Giambattistelli F,Granata G,Barra B,Pampaloni A,Guglielmelli E,Zollo L,Capogrosso M,Micera S,Raspopovic S

    更新日期:2019-04-08 00:00:00

  • Noninvasive measurement of cardiac stroke volume using pulse wave velocity and aortic dimensions: a simulation study.

    abstract:BACKGROUND:Concerns about the cost-effectiveness of invasive hemodynamic monitoring in critically ill patients using pulmonary artery catheters motivate a renewed search for effective noninvasive methods to measure stroke volume. This paper explores a new approach based on noninvasively measured pulse wave velocity, pu...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-13-137

    authors: Babbs CF

    更新日期:2014-09-19 00:00:00

  • Effect of manufacturing and experimental conditions on the mechanical and surface properties of silicone elastomer scaffolds used in endothelial mechanobiological studies.

    abstract:BACKGROUND:Mechanobiological studies allow the characterization of cell response to mechanical stresses. Cells need to be supported by a material with properties similar to the physiological environment. Silicone elastomers have been used to produce various in vitro scaffolds of different geometries for endothelial cel...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-017-0380-5

    authors: Campeau MA,Lortie A,Tremblay P,Béliveau MO,Dubé D,Langelier È,Rouleau L

    更新日期:2017-07-14 00:00:00

  • An in vitro test bench reproducing coronary blood flow signals.

    abstract:BACKGROUND:It is a known fact that blood flow pattern and more specifically the pulsatile time variation of shear stress on the vascular wall play a key role in atherogenesis. The paper presents the conception, the building and the control of a new in vitro test bench that mimics the pulsatile flows behavior based on i...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-015-0065-x

    authors: Chodzyński KJ,Boudjeltia KZ,Lalmand J,Aminian A,Vanhamme L,de Sousa DR,Gremmo S,Bricteux L,Renotte C,Courbebaisse G,Coussement G

    更新日期:2015-08-07 00:00:00

  • Performance evaluation of a motor-imagery-based EEG-Brain computer interface using a combined cue with heterogeneous training data in BCI-Naive subjects.

    abstract:BACKGROUND:The subjects in EEG-Brain computer interface (BCI) system experience difficulties when attempting to obtain the consistent performance of the actual movement by motor imagery alone. It is necessary to find the optimal conditions and stimuli combinations that affect the performance factors of the EEG-BCI syst...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-10-91

    authors: Choi D,Ryu Y,Lee Y,Lee M

    更新日期:2011-10-12 00:00:00

  • Biomechanical investigation of dynamic hip screw and wire fixation on an unstable intertrochanteric fracture.

    abstract:BACKGROUND:Although use of a dynamic hip screw (DHS) for stable intertrochanteric hip fracture fixation has been successfully applied in fracture healing for more than 20 years, DHS fixation on unstable intertrochanteric fractures still has a high failure rate, especially in patients with osteoporosis. Although the wir...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-019-0663-0

    authors: Wu HF,Chang CH,Wang GJ,Lai KA,Chen CH

    更新日期:2019-04-24 00:00:00

  • Real-time feature extraction of P300 component using adaptive nonlinear principal component analysis.

    abstract:BACKGROUND:The electroencephalography (EEG) signals are known to involve the firings of neurons in the brain. The P300 wave is a high potential caused by an event-related stimulus. The detection of P300s included in the measured EEG signals is widely investigated. The difficulties in detecting them are that they are mi...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-10-83

    authors: Turnip A,Hong KS,Jeong MY

    更新日期:2011-09-23 00:00:00

  • Effects of 8-week swimming training on carotid arterial stiffness and hemodynamics in young overweight adults.

    abstract:BACKGROUND:Exercise has been found to either reduce or increase arterial stiffness. Land-based exercise modalities have been documented as effective physical therapies to decrease arterial stiffness. However, these land-based exercise modalities may not be suitable for overweight individuals, in terms of risks of joint...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-016-0274-y

    authors: Yuan WX,Liu HB,Gao FS,Wang YX,Qin KR

    更新日期:2016-12-28 00:00:00