The effect of baseline pressure errors on an intracranial pressure-derived index: results of a prospective observational study.

Abstract:

BACKGROUND:In order to characterize the intracranial pressure-volume reserve capacity, the correlation coefficient (R) between the ICP wave amplitude (A) and the mean ICP level (P), the RAP index, has been used to improve the diagnostic value of ICP monitoring. Baseline pressure errors (BPEs), caused by spontaneous shifts or drifts in baseline pressure, cause erroneous readings of mean ICP. Consequently, BPEs could also affect ICP indices such as the RAP where in the mean ICP is incorporated. METHODS:A prospective, observational study was carried out on patients with aneurysmal subarachnoid hemorrhage (aSAH) undergoing ICP monitoring as part of their surveillance. Via the same burr hole in the scull, two separate ICP sensors were placed close to each other. For each consecutive 6-sec time window, the dynamic mean ICP wave amplitude (MWA; measure of the amplitude of the single pressure waves) and the static mean ICP, were computed. The RAP index was computed as the Pearson correlation coefficient between the MWA and the mean ICP for 40 6-sec time windows, i.e. every subsequent 4-min period (method 1). We compared this approach with a method of calculating RAP using a 4-min moving window updated every 6 seconds (method 2). RESULTS:The study included 16 aSAH patients. We compared 43,653 4-min RAP observations of signals 1 and 2 (method 1), and 1,727,000 6-sec RAP observations (method 2). The two methods of calculating RAP produced similar results. Differences in RAP ≥ 0.4 in at least 7% of observations were seen in 5/16 (31%) patients. Moreover, the combination of a RAP of ≥ 0.6 in one signal and <0.6 in the other was seen in ≥ 13% of RAP-observations in 4/16 (25%) patients, and in ≥ 8% in another 4/16 (25%) patients. The frequency of differences in RAP >0.2 was significantly associated with the frequency of BPEs (5 mmHg ≤ BPE <10 mmHg). CONCLUSIONS:Simultaneous monitoring from two separate, close-by ICP sensors reveals significant differences in RAP that correspond to the occurrence of BPEs. As differences in RAP are of magnitudes that may alter patient management, we do not advocate the use of RAP in the management of neurosurgical patients.

journal_name

Biomed Eng Online

authors

Eide PK,Sorteberg A,Meling TR,Sorteberg W

doi

10.1186/1475-925X-13-99

subject

Has Abstract

pub_date

2014-07-23 00:00:00

pages

99

issn

1475-925X

pii

1475-925X-13-99

journal_volume

13

pub_type

杂志文章
  • A computational model study of the influence of the anatomy of the circle of willis on cerebral hyperperfusion following carotid artery surgery.

    abstract:BACKGROUND:Cerebral hyperperfusion syndrome develops in a small subset of patients following carotid artery surgery (CAS) performed to treat severe carotid artery stenosis. This syndrome has been found to have a close correlation with cerebral hyperperfusion occurring after CAS. The purpose of this study is to investig...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-10-84

    authors: Liang F,Fukasaku K,Liu H,Takagi S

    更新日期:2011-09-23 00:00:00

  • Influence of model boundary conditions on blood flow patterns in a patient specific stenotic right coronary artery.

    abstract:BACKGROUND:In literature, the effect of the inflow boundary condition was investigated by examining the impact of the waveform and the shape of the spatial profile of the inlet velocity on the cardiac hemodynamics. However, not much work has been reported on comparing the effect of the different combinations of the inl...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-14-S1-S6

    authors: Liu B,Zheng J,Bach R,Tang D

    更新日期:2015-01-01 00:00:00

  • Evolutionary optimization of classifiers and features for single-trial EEG discrimination.

    abstract:BACKGROUND:State-of-the-art signal processing methods are known to detect information in single-trial event-related EEG data, a crucial aspect in development of real-time applications such as brain computer interfaces. This paper investigates one such novel approach, evaluating how individual classifier and feature sub...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-6-32

    authors: Aberg MC,Wessberg J

    更新日期:2007-08-23 00:00:00

  • Mechanical strain promotes osteoblast ECM formation and improves its osteoinductive potential.

    abstract:BACKGROUND:The extracellular matrix (ECM) provides a supportive microenvironment for cells, which is suitable as a tissue engineering scaffold. Mechanical stimulus plays a significant role in the fate of osteoblast, suggesting that it regulates ECM formation. Therefore, we investigated the influence of mechanical stimu...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-11-80

    authors: Guo Y,Zhang CQ,Zeng QC,Li RX,Liu L,Hao QX,Shi CH,Zhang XZ,Yan YX

    更新日期:2012-10-25 00:00:00

  • Objective assessment of spasticity by pendulum test: a systematic review on methods of implementation and outcome measures.

    abstract:BACKGROUND:Instrumented pendulum test is an objective and repeatable biomechanical method of assessment for spasticity. However, multitude of sensor technologies and plenty of suggested outcome measures, confuse those interested in implementing this method in practice. Lack of a standard agreement on the definition of ...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章,评审

    doi:10.1186/s12938-020-00826-8

    authors: Rahimi F,Eyvazpour R,Salahshour N,Azghani MR

    更新日期:2020-11-09 00:00:00

  • Automatic lumen segmentation in IVOCT images using binary morphological reconstruction.

    abstract:BACKGROUND:Atherosclerosis causes millions of deaths, annually yielding billions in expenses round the world. Intravascular Optical Coherence Tomography (IVOCT) is a medical imaging modality, which displays high resolution images of coronary cross-section. Nonetheless, quantitative information can only be obtained with...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-12-78

    authors: Moraes MC,Cardenas DA,Furuie SS

    更新日期:2013-08-09 00:00:00

  • Correction to: Proposal of a new conceptual gait model for patients with Parkinson's disease based on factor analysis.

    abstract::It was highlighted that the original article [1] had an omission in the Abstract. This Correction article shows the omitted sentence: "This article [1] was awarded the SIAMOC Best Methodological Paper 2018". ...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章,已发布勘误

    doi:10.1186/s12938-019-0698-2

    authors: Arcolin I,Corna S,Giardini M,Giordano A,Nardone A,Godi M

    更新日期:2019-07-23 00:00:00

  • Computer-aided analysis of micro-morphological structure of porous membranes.

    abstract:BACKGROUND:The paper presents an approach and computer-aided method of numerical evaluation of the quality of porous membranes used as scaffolds for cultivation of chondrocytes in regeneration of biological tissues. MATERIALS:The scanning electron microscope (SEM) images of 300× and 1000× magnification presenting the ...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-018-0481-9

    authors: Kulikowski JL,Przytulska M,Chwojnowski A

    更新日期:2018-05-30 00:00:00

  • Effect of pressure and padding on motion artifact of textile electrodes.

    abstract:BACKGROUND:With the aging population and rising healthcare costs, wearable monitoring is gaining importance. The motion artifact affecting dry electrodes is one of the main challenges preventing the widespread use of wearable monitoring systems. In this paper we investigate the motion artifact and ways of making a text...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-12-26

    authors: Cömert A,Honkala M,Hyttinen J

    更新日期:2013-04-08 00:00:00

  • A development of assistant surgical robot system based on surgical-operation-by-wire and hands-on-throttle-and-stick.

    abstract:BACKGROUND:Robot-assisted laparoscopic surgery offers several advantages compared with open surgery and conventional minimally invasive surgery. However, one issue that needs to be resolved is a collision between the robot arm and the assistant instrument. This is mostly caused by miscommunication between the surgeon a...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-016-0189-7

    authors: Kim M,Lee C,Park WJ,Suh YS,Yang HK,Kim HJ,Kim S

    更新日期:2016-05-20 00:00:00

  • Challenges on optimization of 3D-printed bone scaffolds.

    abstract::Advances in biomaterials and the need for patient-specific bone scaffolds require modern manufacturing approaches in addition to a design strategy. Hybrid materials such as those with functionally graded properties are highly needed in tissue replacement and repair. However, their constituents, proportions, sizes, con...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章,评审

    doi:10.1186/s12938-020-00810-2

    authors: Bahraminasab M

    更新日期:2020-09-03 00:00:00

  • Performance evaluation of a motor-imagery-based EEG-Brain computer interface using a combined cue with heterogeneous training data in BCI-Naive subjects.

    abstract:BACKGROUND:The subjects in EEG-Brain computer interface (BCI) system experience difficulties when attempting to obtain the consistent performance of the actual movement by motor imagery alone. It is necessary to find the optimal conditions and stimuli combinations that affect the performance factors of the EEG-BCI syst...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-10-91

    authors: Choi D,Ryu Y,Lee Y,Lee M

    更新日期:2011-10-12 00:00:00

  • Comparison of named entity recognition methodologies in biomedical documents.

    abstract:BACKGROUND:Biomedical named entity recognition (Bio-NER) is a fundamental task in handling biomedical text terms, such as RNA, protein, cell type, cell line, and DNA. Bio-NER is one of the most elementary and core tasks in biomedical knowledge discovery from texts. The system described here is developed by using the Bi...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-018-0573-6

    authors: Song HJ,Jo BC,Park CY,Kim JD,Kim YS

    更新日期:2018-11-06 00:00:00

  • Mitigation of impedance changes due to electroporation therapy using bursts of high-frequency bipolar pulses.

    abstract:BACKGROUND:For electroporation-based therapies, accurate modeling of the electric field distribution within the target tissue is important for predicting the treatment volume. In response to conventional, unipolar pulses, the electrical impedance of a tissue varies as a function of the local electric field, leading to ...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-14-S3-S3

    authors: Bhonsle SP,Arena CB,Sweeney DC,Davalos RV

    更新日期:2015-01-01 00:00:00

  • Short-term mechanical stretch fails to differentiate human adipose-derived stem cells into cardiovascular cell phenotypes.

    abstract:BACKGROUND:We and others have previously demonstrated that adipose-derived stem cells (ASCs) transplantation improve cardiac dysfunction post-myocardium infarction (MI) under hemodynamic stress in rats. The beneficial effects appear to be associated with pleiotropic factors due to a complex interplay between the transp...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-13-54

    authors: Girão-Silva T,Bassaneze V,Campos LC,Barauna VG,Dallan LA,Krieger JE,Miyakawa AA

    更新日期:2014-05-01 00:00:00

  • Three-dimensional dominant frequency mapping using autoregressive spectral analysis of atrial electrograms of patients in persistent atrial fibrillation.

    abstract:BACKGROUND:Areas with high frequency activity within the atrium are thought to be 'drivers' of the rhythm in patients with atrial fibrillation (AF) and ablation of these areas seems to be an effective therapy in eliminating DF gradient and restoring sinus rhythm. Clinical groups have applied the traditional FFT-based a...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-016-0143-8

    authors: Salinet JL,Masca N,Stafford PJ,Ng GA,Schlindwein FS

    更新日期:2016-03-08 00:00:00

  • In-vivo coronary flow profiling based on biplane angiograms: influence of geometric simplifications on the three-dimensional reconstruction and wall shear stress calculation.

    abstract:BACKGROUND:Clinical studies suggest that local wall shear stress (WSS) patterns modulate the site and the progression of atherosclerotic lesions. Computational fluid dynamics (CFD) methods based on in-vivo three-dimensional vessel reconstructions have recently been shown to provide prognostically relevant WSS data. Thi...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-5-39

    authors: Wellnhofer E,Goubergrits L,Kertzscher U,Affeld K

    更新日期:2006-06-14 00:00:00

  • Regional differences in APD restitution can initiate wavebreak and re-entry in cardiac tissue: a computational study.

    abstract:BACKGROUND:Regional differences in action potential duration (APD) restitution in the heart favour arrhythmias, but the mechanism is not well understood. METHODS:We simulated a 150 x 150 mm 2D sheet of cardiac ventricular tissue using a simplified computational model. We investigated wavebreak and re-entry initiated b...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-4-54

    authors: Clayton RH,Taggart P

    更新日期:2005-09-20 00:00:00

  • Investigation of red blood cell mechanical properties using AFM indentation and coarse-grained particle method.

    abstract:BACKGROUND:Red blood cells (RBCs) deform significantly and repeatedly when passing through narrow capillaries and delivering dioxygen throughout the body. Deformability of RBCs is a key characteristic, largely governed by the mechanical properties of the cell membrane. This study investigated RBC mechanical properties ...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-017-0429-5

    authors: Barns S,Balanant MA,Sauret E,Flower R,Saha S,Gu Y

    更新日期:2017-12-19 00:00:00

  • Automatic QRS complex detection using two-level convolutional neural network.

    abstract:BACKGROUND:The QRS complex is the most noticeable feature in the electrocardiogram (ECG) signal, therefore, its detection is critical for ECG signal analysis. The existing detection methods largely depend on hand-crafted manual features and parameters, which may introduce significant computational complexity, especiall...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-018-0441-4

    authors: Xiang Y,Lin Z,Meng J

    更新日期:2018-01-29 00:00:00

  • Development and mechanical testing of a short intramedullary nail for fixation of femoral rotational osteotomy in cerebral palsy patients.

    abstract:BACKGROUND:Rotational osteotomy is frequently indicated to correct excessive femoral anteversion in cerebral palsy patients. Angled blade plate is the standard fixation device used when performed in the proximal femur, but extensile exposure is required for plate accommodation. The authors developed a short locked intr...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-10-57

    authors: Pagnano RG,Okubo R,Volpon JB

    更新日期:2011-06-28 00:00:00

  • Dendritic tree extraction from noisy maximum intensity projection images in C. elegans.

    abstract:BACKGROUND:Maximum Intensity Projections (MIP) of neuronal dendritic trees obtained from confocal microscopy are frequently used to study the relationship between tree morphology and mechanosensory function in the model organism C. elegans. Extracting dendritic trees from noisy images remains however a strenuous proces...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-13-74

    authors: Greenblum A,Sznitman R,Fua P,Arratia PE,Oren M,Podbilewicz B,Sznitman J

    更新日期:2014-06-12 00:00:00

  • Low-cost equipment for the evaluation of reach and grasp in post-stroke individuals: a pilot study.

    abstract:BACKGROUND:Reach-grasp movements are motor components commonly affected after stroke and directly related to the independence of these individuals. Evaluations of these activities can be performed using clinical instruments and assessed by detailed and costly kinematic analyses. The aim of this study was to develop an ...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-020-0758-7

    authors: Gomes CLA,Cacho RO,Nobrega VTB,de A Confessor EM,de Farias EEM,Neto JLF,de Araújo DS,de S Medeiros AL,Barreto RL,Cacho EWA

    更新日期:2020-03-04 00:00:00

  • Growth rate and rupture rate of unruptured intracranial aneurysms: a population approach.

    abstract:BACKGROUND:Understanding aneurysm growth rate allows us to predict not only the current rupture risk, but also accumulated rupture risk in the future. However, determining growth rate of unruptured intracranial aneurysms often requires follow-up of patients for a long period of time so that significant growth can be ob...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-8-11

    authors: Jou LD,Mawad ME

    更新日期:2009-06-18 00:00:00

  • Heart rate variability analysis using robust period detection.

    abstract:OBJECTIVE:Heart rate variability (HRV) analysis, which is an important tool for activity assessment of the cardiac autonomic nervous system, very often includes the estimation of power spectra for series of interbeat intervals (IBI). Ectopic beats and artifacts have a destructive effect on the standard methods (Fourier...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-13-138

    authors: Skotte JH,Kristiansen J

    更新日期:2014-09-23 00:00:00

  • Integrated EIT system for functional lung ventilation imaging.

    abstract:BACKGROUND:Electrical impedance tomography (EIT) has been used for functional lung imaging of regional air distributions during mechanical ventilation in intensive care units (ICU). From numerous clinical and animal studies focusing on specific lung functions, a consensus about how to use the EIT technique has been for...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-019-0701-y

    authors: Jang GY,Ayoub G,Kim YE,Oh TI,Chung CR,Suh GY,Woo EJ

    更新日期:2019-07-25 00:00:00

  • Classification of voice disorder in children with cochlear implantation and hearing aid using multiple classifier fusion.

    abstract:BACKGROUND:Speech production and speech phonetic features gradually improve in children by obtaining audio feedback after cochlear implantation or using hearing aids. The aim of this study was to develop and evaluate automated classification of voice disorder in children with cochlear implantation and hearing aids. ME...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-10-3

    authors: Mahmoudi Z,Rahati S,Ghasemi MM,Asadpour V,Tayarani H,Rajati M

    更新日期:2011-01-14 00:00:00

  • Non-viral eNOS gene delivery and transfection with stents for the treatment of restenosis.

    abstract:BACKGROUND:In this study, we have examined local non-viral gene delivery, transfection, and therapeutic efficacy of endothelial nitric oxide synthase (eNOS) encoding plasmid DNA administered using coated stents in a rabbit iliac artery restenosis model. METHODS:Lipopolyplexes (LPPs) with eNOS expressing plasmid DNA we...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-9-56

    authors: Brito LA,Chandrasekhar S,Little SR,Amiji MM

    更新日期:2010-09-27 00:00:00

  • Blood pressure waveform contour analysis for assessing peripheral resistance changes in sepsis.

    abstract:BACKGROUND:This paper proposes a methodology for helping bridge the gap between the complex waveform information frequently available in an intensive care unit and the simple, lumped values favoured for rapid clinical diagnosis and management. This methodology employs a simple waveform contour analysis approach to comp...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-018-0603-4

    authors: Davidson S,Pretty C,Balmer J,Desaive T,Chase JG

    更新日期:2018-11-20 00:00:00

  • In vivo myograph measurement of muscle contraction at optimal length.

    abstract:BACKGROUND:Current devices for measuring muscle contraction in vivo have limited accuracy in establishing and re-establishing the optimum muscle length. They are variable in the reproducibility to determine the muscle contraction at this length, and often do not maintain precise conditions during the examination. Conse...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-6-1

    authors: Rahe-Meyer N,Weilbach C,Karst M,Pawlak M,Ahmed A,Piepenbrock S,Winterhalter M

    更新日期:2007-01-02 00:00:00