Heart rate variability analysis using robust period detection.

Abstract:

OBJECTIVE:Heart rate variability (HRV) analysis, which is an important tool for activity assessment of the cardiac autonomic nervous system, very often includes the estimation of power spectra for series of interbeat intervals (IBI). Ectopic beats and artifacts have a destructive effect on the standard methods (Fourier transform, FFT) for frequency analysis. This study investigates an alternative method for calculation of the periodogram using a robust period detection (RPD). METHOD:Error free IBI series of 5 minutes for 221 subjects during one day were artificially distorted by randomly changing IBI values by ±15-40%. The low to high frequency rate (LF/HF) were calculated from periodograms estimated by the FFT, RPD and Lomb (LSP) methods for both error free and distorted series and for series with removed beats. Log transformed LF/HF values for series with distorted/removed beats were compared to undistorted values by linear regression. RESULTS:For series with 10% of distorted IBI values the regression analysis between distorted and undistorted series showed a goodness of fit, coefficient and intercept of 0.98, 0.94 and 0.02, respectively. In comparison, the values of these parameters were (0.34, 0.46, -1.61) and (0.28, 0.42,-1.32) for the FFT and LSP methods, respectively. Similarly, the comparison between series with removed and undistorted beats yielded goodness of fit, coefficient and intercept of (0.98, 0.96, -0.01), (0.93, 0.78, -0.02) and (0.98, 0.95, 0.19) for RPD, FFT and LSP, respectively. CONCLUSION:The RPD method demonstrated superior performance compared to the FFT and LSP method by estimation of power spectral characteristics for HRV analysis.

journal_name

Biomed Eng Online

authors

Skotte JH,Kristiansen J

doi

10.1186/1475-925X-13-138

subject

Has Abstract

pub_date

2014-09-23 00:00:00

pages

138

issn

1475-925X

pii

1475-925X-13-138

journal_volume

13

pub_type

杂志文章
  • An inverse method to determine the mechanical properties of the iris in vivo.

    abstract:BACKGROUND:Understanding the mechanical properties of the iris can help to have an insight into the eye diseases with abnormalities of the iris morphology. Material parameters of the iris were simply calculated relying on the ex vivo experiment. However, the mechanical response of the iris in vivo is different from tha...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-13-66

    authors: Zhang K,Qian X,Mei X,Liu Z

    更新日期:2014-05-30 00:00:00

  • Feature extraction for the analysis of colon status from the endoscopic images.

    abstract:BACKGROUND:Extracting features from the colonoscopic images is essential for getting the features, which characterizes the properties of the colon. The features are employed in the computer-assisted diagnosis of colonoscopic images to assist the physician in detecting the colon status. METHODS:Endoscopic images contai...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925x-2-9

    authors: Tjoa MP,Krishnan SM

    更新日期:2003-04-08 00:00:00

  • Osteoblastic differentiation and stress response of human mesenchymal stem cells exposed to alternating current electric fields.

    abstract:BACKGROUND:Electric fields are integral to many biological events, from maintaining cellular homeostasis to embryonic development to healing. The application of electric fields offers substantial therapeutic potential, while optimal dosing regimens and the underlying mechanisms responsible for the positive clinical imp...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-10-9

    authors: Hronik-Tupaj M,Rice WL,Cronin-Golomb M,Kaplan DL,Georgakoudi I

    更新日期:2011-01-26 00:00:00

  • The approximate entropy of the electromyographic signals of tremor correlates with the osmotic fragility of human erythrocytes.

    abstract:BACKGROUND:The main problem of tremor is the damage caused to the quality of the life of patients, especially those at more advanced ages. There is not a consensus yet about the origins of this disorder, but it can be examined in the correlations between the biological signs of aging and the tremor characteristics. ME...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-9-29

    authors: Mansur PH,Cury LK,Leite JO,Pereira AA,Penha-Silva N,Andrade AO

    更新日期:2010-06-22 00:00:00

  • Three types of dermal grafts in rats: the importance of mechanical property and structural design.

    abstract:BACKGROUND:To determine how the mechanical property and micro structure affect tissue regeneration and angiogenesis, three types of scaffolds were studied. Acellular dermal matrices (ADM), produced from human skin by removing the epidermis and cells, has been widely used in wound healing because of its high mechanical ...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-12-125

    authors: You C,Wang X,Zheng Y,Han C

    更新日期:2013-12-04 00:00:00

  • Human coronary plaque wall thickness correlated positively with flow shear stress and negatively with plaque wall stress: an IVUS-based fluid-structure interaction multi-patient study.

    abstract:BACKGROUND:Atherosclerotic plaque progression and rupture are believed to be associated with mechanical stress conditions. In this paper, patient-specific in vivo intravascular ultrasound (IVUS) coronary plaque image data were used to construct computational models with fluid-structure interaction (FSI) and cyclic bend...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-13-32

    authors: Fan R,Tang D,Yang C,Zheng J,Bach R,Wang L,Muccigrosso D,Billiar K,Zhu J,Ma G,Maehara A,Mintz GS

    更新日期:2014-03-26 00:00:00

  • An artifacts removal post-processing for epiphyseal region-of-interest (EROI) localization in automated bone age assessment (BAA).

    abstract:BACKGROUND:Segmentation is the most crucial part in the computer-aided bone age assessment. A well-known type of segmentation performed in the system is adaptive segmentation. While providing better result than global thresholding method, the adaptive segmentation produces a lot of unwanted noise that could affect the ...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-10-87

    authors: Chai HY,Wee LK,Swee TT,Salleh ShH,Chea LY

    更新日期:2011-09-28 00:00:00

  • Automatic lumen segmentation in IVOCT images using binary morphological reconstruction.

    abstract:BACKGROUND:Atherosclerosis causes millions of deaths, annually yielding billions in expenses round the world. Intravascular Optical Coherence Tomography (IVOCT) is a medical imaging modality, which displays high resolution images of coronary cross-section. Nonetheless, quantitative information can only be obtained with...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-12-78

    authors: Moraes MC,Cardenas DA,Furuie SS

    更新日期:2013-08-09 00:00:00

  • Electrochemotherapy of colorectal liver metastases--an observational study of its effects on the electrocardiogram.

    abstract:BACKGROUND:Electrochemotherapy (ECT) is a combined treatment in which high voltage electroporation (EP) pulses are used to facilitate the uptake of a chemotherapeutic drug into tumor cells, thus increasing antitumor effectiveness of the drug. The effect of ECT of deep-seated tumors located close to the heart on functio...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-14-S3-S5

    authors: Mali B,Gorjup V,Edhemovic I,Brecelj E,Cemazar M,Sersa G,Strazisar B,Miklavcic D,Jarm T

    更新日期:2015-01-01 00:00:00

  • Novel flexible cap for application of transcranial electrical stimulation: a usability study.

    abstract:BACKGROUND:Advances in transcranial electrical stimulation (tES) are hampered by the conventional rubber electrodes manually attached to the head with rubber bands. This procedure limits montages to a few electrodes, is error prone with respect to electrode configurations and is burdensome for participants and operator...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-020-00792-1

    authors: Hunold A,Ortega D,Schellhorn K,Haueisen J

    更新日期:2020-06-17 00:00:00

  • Determination of detection depth of optical probe in pedicle screw measurement device.

    abstract:BACKGROUND:There is a high probability of accidental perforation of the vertebral pedicle wall in pedicle screw insertion surgery. A pedicle screw (PS) measurement device with an optical probe has been reported to send out a warning signal before the PS tip breaking the vertebral pedicle wall. METHODS:In this study, w...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-13-148

    authors: Li W,Liu Y,Qian Z

    更新日期:2014-11-01 00:00:00

  • Unsupervised machine-learning method for improving the performance of ambulatory fall-detection systems.

    abstract:BACKGROUND:Falls can cause trauma, disability and death among older people. Ambulatory accelerometer devices are currently capable of detecting falls in a controlled environment. However, research suggests that most current approaches can tend to have insufficient sensitivity and specificity in non-laboratory environme...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-11-9

    authors: Yuwono M,Moulton BD,Su SW,Celler BG,Nguyen HT

    更新日期:2012-02-16 00:00:00

  • Investigations of the functional states of dendritic cells under different conditioned microenvironments by Fourier transformed infrared spectroscopy.

    abstract:BACKGROUND:Dendritic cells are potent and specialized antigen presenting cells, which play a crucial role in initiating and amplifying both the innate and adaptive immune responses. The dendritic cell-based vaccination against cancer has been clinically achieved promising successes. But there are still many challenges ...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-13-2

    authors: Dong R,Long J,Xu X,Zhang C,Wen Z,Li L,Yao W,Zeng Z

    更新日期:2014-01-10 00:00:00

  • A specialized motion capture system for real-time analysis of mandibular movements using infrared cameras.

    abstract:BACKGROUND:In the last years, several methods and devices have been proposed to record the human mandibular movements, since they provide quantitative parameters that support the diagnosis and treatment of temporomandibular disorders. The techniques currently employed suffer from a number of drawbacks including high pr...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-12-17

    authors: Furtado DA,Pereira AA,Andrade Ade O,Bellomo DP Jr,da Silva MR

    更新日期:2013-02-22 00:00:00

  • Low-dose CT reconstruction via L1 dictionary learning regularization using iteratively reweighted least-squares.

    abstract:BACKGROUND:In order to reduce the radiation dose of CT (computed tomography), compressed sensing theory has been a hot topic since it provides the possibility of a high quality recovery from the sparse sampling data. Recently, the algorithm based on DL (dictionary learning) was developed to deal with the sparse CT reco...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-016-0193-y

    authors: Zhang C,Zhang T,Li M,Peng C,Liu Z,Zheng J

    更新日期:2016-06-18 00:00:00

  • Respiratory sinus arrhythmia reactivity of internet addiction abusers in negative and positive emotional states using film clips stimulation.

    abstract:BACKGROUND AND AIMS:People with internet addiction (IA) suffer from mental, physical, social, and occupational problems. IA includes psychological and physiological syndromes, and among the syndromes, emotion was suggested important mental and physiological expressions of IA. However, few physiologically emotional char...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-016-0201-2

    authors: Hsieh DL,Hsiao TC

    更新日期:2016-07-04 00:00:00

  • In vivo long-term investigation of tumor bearing mKate2 by an in-house fluorescence molecular imaging system.

    abstract:BACKGROUND:Optical imaging is one of the most common, low-cost imaging tools used for investigating the tumor biological behavior in vivo. This study explores the feasibility and sensitivity of a near infrared fluorescent protein mKate2 for a long-term non-invasive tumor imaging in BALB/c nude mice, by using a low-powe...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-018-0615-0

    authors: Zhou K,Ding Y,Vuletic I,Tian Y,Li J,Liu J,Huang Y,Sun H,Li C,Ren Q,Lu Y

    更新日期:2018-12-29 00:00:00

  • Effect of manufacturing and experimental conditions on the mechanical and surface properties of silicone elastomer scaffolds used in endothelial mechanobiological studies.

    abstract:BACKGROUND:Mechanobiological studies allow the characterization of cell response to mechanical stresses. Cells need to be supported by a material with properties similar to the physiological environment. Silicone elastomers have been used to produce various in vitro scaffolds of different geometries for endothelial cel...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-017-0380-5

    authors: Campeau MA,Lortie A,Tremblay P,Béliveau MO,Dubé D,Langelier È,Rouleau L

    更新日期:2017-07-14 00:00:00

  • In memorium: Herman p. Schwan [1915-2005].

    abstract::Herman P. Schwan [1915-2005] was a distinguished scientist and engineer, and a founding father of the field of biomedical engineering. A man of integrity, Schwan influenced the lives of many, including his wife and children, and his many students and colleagues. Active in science until nearly the end of his life, he w...

    journal_title:Biomedical engineering online

    pub_type: 传,历史文章,杂志文章

    doi:10.1186/1475-925X-4-21

    authors: Foster KR

    更新日期:2005-03-25 00:00:00

  • Noise reduction of diffusion tensor images by sparse representation and dictionary learning.

    abstract:BACKGROUND:The low quality of diffusion tensor image (DTI) could affect the accuracy of oncology diagnosis. METHODS:We present a novel sparse representation based denoising method for three dimensional DTI by learning adaptive dictionary with the context redundancy between neighbor slices. In this study, the context r...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-015-0116-3

    authors: Kong Y,Li Y,Wu J,Shu H

    更新日期:2016-01-13 00:00:00

  • The effect of inlet and outlet boundary conditions in image-based CFD modeling of aortic flow.

    abstract:BACKGROUND:Computational modeling of cardiovascular flow is a growing and useful field, but such simulations usually require the researcher to guess the flow's inlet and outlet conditions since they are difficult and expensive to measure. It is critical to determine the amount of uncertainty introduced by these assumpt...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-018-0497-1

    authors: Madhavan S,Kemmerling EMC

    更新日期:2018-05-30 00:00:00

  • Examination of ceramic restoration adhesive coverage in cusp-replacement premolar using acoustic emission under fatigue testing.

    abstract:BACKGROUND:This study investigates CAD/CAM ceramic cusp-replacing restoration resistance with and without buccal cusp replacement under static and dynamic cyclic loads, monitored using the acoustic emission (AE) technique. METHOD:The cavity was designed in a typical MODP (mesial-occlusal-distal-palatal) restoration fa...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-13-165

    authors: Chang YH,Yu JJ,Lin CL

    更新日期:2014-12-13 00:00:00

  • Computational studies of the effects of myocardial blood flow reductions on cardiac metabolism.

    abstract:BACKGROUND:A computational model of myocardial energy metabolism was used to assess the metabolic responses to normal and reduced myocardial blood flow. The goal was to examine to what extent glycolysis and lactate formation are controlled by the supply of glycolytic substrate and/or the cellular redox (NADH/NAD+) and ...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-3-15

    authors: Salem JE,Stanley WC,Cabrera ME

    更新日期:2004-06-02 00:00:00

  • Effect of glutaraldehyde based cross-linking on the viscoelasticity of mitral valve basal chordae tendineae.

    abstract:BACKGROUND:Mitral valve failure can require repair or replacement. Replacement bioprosthetic valves are treated with glutaraldehyde prior to implantation. The aim of this study was to determine the changes in mechanical properties following glutaraldehyde fixation of mitral valve chordae. METHODS:To investigate the im...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-018-0524-2

    authors: Constable M,Burton HE,Lawless BM,Gramigna V,Buchan KG,Espino DM

    更新日期:2018-07-13 00:00:00

  • Computational and experimental assessment of influences of hemodynamic shear stress on carotid plaque.

    abstract:BACKGROUND:Studies have identified hemodynamic shear stress as an important determinant of endothelial function and atherosclerosis. In this study, we assess the influences of hemodynamic shear stress on carotid plaques. METHODS:Carotid stenosis phantoms with three severity (30, 50, 70%) were made from 10% polyvinyl a...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-017-0386-z

    authors: Zhou H,Meng L,Zhou W,Xin L,Xia X,Li S,Zheng H,Niu L

    更新日期:2017-07-29 00:00:00

  • A numerical study of the effect of varied blood pressure on the stability of carotid atherosclerotic plaque.

    abstract:BACKGROUND:Blood pressure (BP) is associated with early atherosclerosis and plaque rupture because the BP variability can significantly affect the blood flow velocity and shear stress over the plaque. However, the mechanical response of BP variability to the plaque remains unclear. Therefore, we investigated the correl...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-13-152

    authors: Xiong H,Liu X,Tian X,Pu L,Zhang H,Lu M,Huang W,Zhang YT

    更新日期:2014-11-20 00:00:00

  • Risk and reward: extending stochastic glycaemic control intervals to reduce workload.

    abstract:BACKGROUND:STAR is a model-based, personalised, risk-based dosing approach for glycaemic control (GC) in critically ill patients. STAR provides safe, effective control to nearly all patients, using 1-3 hourly measurement and intervention intervals. However, the average 11-12 measurements per day required can be a clini...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-020-00771-6

    authors: Uyttendaele V,Knopp JL,Shaw GM,Desaive T,Chase JG

    更新日期:2020-04-29 00:00:00

  • Evaluation of needle movement effect on root canal irrigation using a computational fluid dynamics model.

    abstract:BACKGROUND:Irrigation is considered to be a critical part of root canal treatment. However, little is known about the effect of needle movement on the irrigation process. Therefore, this study aimed to investigate the influence of the syringe and needle movement on root canal irrigation using a three-dimensional comput...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-019-0679-5

    authors: Hu S,Duan L,Wan Q,Wang J

    更新日期:2019-05-06 00:00:00

  • Using stochastic modelling to identify unusual continuous glucose monitor measurements and behaviour, in newborn infants.

    abstract:BACKGROUND:Abnormal blood glucose (BG) concentrations have been associated with increased morbidity and mortality in both critically ill adults and infants. Furthermore, hypoglycaemia and glycaemic variability have both been independently linked to mortality in these patients. Continuous Glucose Monitoring (CGM) device...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-11-45

    authors: Signal M,Le Compte A,Harris DL,Weston PJ,Harding JE,Chase JG,CHYLD Study Group.

    更新日期:2012-08-06 00:00:00

  • A multivariate relationship between the kinematic and clinical parameters of knee osteoarthritis population.

    abstract:BACKGROUND:Biomechanical and clinical parameters contribute very closely to functional evaluations of the knee joint. To better understand knee osteoarthritis joint function, the association between a set of knee biomechanical data and a set of clinical parameters of an osteoarthritis population (OA) is investigated in...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-019-0676-8

    authors: Bensalma F,Mezghani N,Ouakrim Y,Fuentes A,Choinière M,Bureau NJ,Durand M,Hagemeister N

    更新日期:2019-05-15 00:00:00