Abstract:
BACKGROUND:Extracting features from the colonoscopic images is essential for getting the features, which characterizes the properties of the colon. The features are employed in the computer-assisted diagnosis of colonoscopic images to assist the physician in detecting the colon status. METHODS:Endoscopic images contain rich texture and color information. Novel schemes are developed to extract new texture features from the texture spectra in the chromatic and achromatic domains, and color features for a selected region of interest from each color component histogram of the colonoscopic images. These features are reduced in size using Principal Component Analysis (PCA) and are evaluated using Backpropagation Neural Network (BPNN). RESULTS:Features extracted from endoscopic images were tested to classify the colon status as either normal or abnormal. The classification results obtained show the features' capability for classifying the colon's status. The average classification accuracy, which is using hybrid of the texture and color features with PCA (tau = 1%), is 97.72%. It is higher than the average classification accuracy using only texture (96.96%, tau = 1%) or color (90.52%, tau = 1%) features. CONCLUSION:In conclusion, novel methods for extracting new texture- and color-based features from the colonoscopic images to classify the colon status have been proposed. A new approach using PCA in conjunction with BPNN for evaluating the features has also been proposed. The preliminary test results support the feasibility of the proposed method.
journal_name
Biomed Eng Onlinejournal_title
Biomedical engineering onlineauthors
Tjoa MP,Krishnan SMdoi
10.1186/1475-925x-2-9keywords:
subject
Has Abstractpub_date
2003-04-08 00:00:00pages
9issn
1475-925Xjournal_volume
2pub_type
杂志文章abstract:BACKGROUND:Speech production and speech phonetic features gradually improve in children by obtaining audio feedback after cochlear implantation or using hearing aids. The aim of this study was to develop and evaluate automated classification of voice disorder in children with cochlear implantation and hearing aids. ME...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/1475-925X-10-3
更新日期:2011-01-14 00:00:00
abstract::Since falls are a major public health problem among older people, the number of systems aimed at detecting them has increased dramatically over recent years. This work presents an extensive literature review of fall detection systems, including comparisons among various kinds of studies. It aims to serve as a referenc...
journal_title:Biomedical engineering online
pub_type: 杂志文章,评审
doi:10.1186/1475-925X-12-66
更新日期:2013-07-06 00:00:00
abstract:BACKGROUND:Human embryonic stem cells (hESCs) are a potential source of cells for use in regenerative medicine. Automation of culturing, monitoring and analysis is crucial for fast and reliable optimization of hESC culturing methods. Continuous monitoring of living cell cultures can reveal more information and is faste...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/1475-925X-6-11
更新日期:2007-04-12 00:00:00
abstract:BACKGROUND:Shape of the dental root canal is highly patient specific. Automated identification methods of the medial line of dental root canals and the reproduction of their 3D shape can be beneficial for planning endodontic interventions as severely curved root canals or multi-rooted teeth may pose treatment challenge...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/1475-925X-11-81
更新日期:2012-10-29 00:00:00
abstract:BACKGROUND:EMG-to-force estimation based on muscle models, for voluntary contraction has many applications in human motion analysis. The so-called Hill model is recognized as a standard model for this practical use. However, it is a phenomenological model whereby muscle activation, force-length and force-velocity prope...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/1475-925X-12-86
更新日期:2013-09-04 00:00:00
abstract:BACKGROUND:Irrigation is considered to be a critical part of root canal treatment. However, little is known about the effect of needle movement on the irrigation process. Therefore, this study aimed to investigate the influence of the syringe and needle movement on root canal irrigation using a three-dimensional comput...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/s12938-019-0679-5
更新日期:2019-05-06 00:00:00
abstract:BACKGROUND:STAR is a model-based, personalised, risk-based dosing approach for glycaemic control (GC) in critically ill patients. STAR provides safe, effective control to nearly all patients, using 1-3 hourly measurement and intervention intervals. However, the average 11-12 measurements per day required can be a clini...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/s12938-020-00771-6
更新日期:2020-04-29 00:00:00
abstract:BACKGROUND:The low quality of diffusion tensor image (DTI) could affect the accuracy of oncology diagnosis. METHODS:We present a novel sparse representation based denoising method for three dimensional DTI by learning adaptive dictionary with the context redundancy between neighbor slices. In this study, the context r...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/s12938-015-0116-3
更新日期:2016-01-13 00:00:00
abstract:OBJECTIVES:To compare traditional plaster casts, digital models and 3D printed copies of dental plaster casts based on various criteria. To determine whether 3D printed copies obtained using open source system RepRap can replace traditional plaster casts in dental practice. To compare and contrast the qualities of two ...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/1475-925X-12-49
更新日期:2013-05-31 00:00:00
abstract:BACKGROUND:Gait analysis and research have been developed to obtain characteristics of movement patterns of people while walking. However, traditional measuring systems present different drawbacks that reduce their use and application. Among those drawbacks one can find: high price, low sampling frequency and limiting ...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/1475-925X-13-34
更新日期:2014-03-31 00:00:00
abstract::It was highlighted that the original article [1] contained an error in the Acknowledgments section. ...
journal_title:Biomedical engineering online
pub_type: 杂志文章,已发布勘误
doi:10.1186/s12938-019-0707-5
更新日期:2019-08-08 00:00:00
abstract:BACKGROUND:Frequency selectivity (FS) of the auditory system is established at the level of the cochlea and it is important for the perception of complex sounds. Although direct measurements of cochlear FS require surgical preparation, it can also be estimated with the measurements of otoacoustic emissions or behaviora...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/s12938-016-0167-0
更新日期:2016-05-10 00:00:00
abstract::It was highlighted that the original article [1] had an omission in the Abstract. This Correction article shows the omitted sentence: "This article [1] was awarded the SIAMOC Best Methodological Paper 2018". ...
journal_title:Biomedical engineering online
pub_type: 杂志文章,已发布勘误
doi:10.1186/s12938-019-0698-2
更新日期:2019-07-23 00:00:00
abstract:BACKGROUND:Xenogeneic bone has been widely used in a variety of clinical bone-related disease to promote bone healing and restore bone defects. However, the adverse effects of immune system limit its application in the clinic. The aim of this study was to evaluate xenogeneic bone safety of immunotoxicity and explore th...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/s12938-019-0729-z
更新日期:2019-11-14 00:00:00
abstract:BACKGROUND:In order to reduce the radiation dose of CT (computed tomography), compressed sensing theory has been a hot topic since it provides the possibility of a high quality recovery from the sparse sampling data. Recently, the algorithm based on DL (dictionary learning) was developed to deal with the sparse CT reco...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/s12938-016-0193-y
更新日期:2016-06-18 00:00:00
abstract:BACKGROUND:One of the recommended treatments for disorders associated with the lower extremity venous insufficiency is the application of external mechanical compression. Compression stockings and elastic bandages are widely used for the purpose of compression therapy and are usually designed to exert a specified value...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/s12938-015-0088-3
更新日期:2015-11-05 00:00:00
abstract:BACKGROUND:Tortuous arteries are often seen in patients with hypertension and atherosclerosis. While the mechanical stress in atherosclerotic plaque under lumen pressure has been studied extensively, the mechanical stability of atherosclerotic arteries and subsequent effect on the plaque stress remain unknown. To this ...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/1475-925X-14-S1-S4
更新日期:2015-01-01 00:00:00
abstract:BACKGROUND:Biomechanical and clinical parameters contribute very closely to functional evaluations of the knee joint. To better understand knee osteoarthritis joint function, the association between a set of knee biomechanical data and a set of clinical parameters of an osteoarthritis population (OA) is investigated in...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/s12938-019-0676-8
更新日期:2019-05-15 00:00:00
abstract:BACKGROUND:Knowing the orientation of the head is important in many fields, including medicine. Many methods and measuring systems exist, but usually they use different markers or sensors attached to the subject's head for head orientation determination. In certain applications these attachments may represent a burden ...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/1475-925X-12-96
更新日期:2013-09-26 00:00:00
abstract:BACKGROUND:Abnormal blood glucose (BG) concentrations have been associated with increased morbidity and mortality in both critically ill adults and infants. Furthermore, hypoglycaemia and glycaemic variability have both been independently linked to mortality in these patients. Continuous Glucose Monitoring (CGM) device...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/1475-925X-11-45
更新日期:2012-08-06 00:00:00
abstract:BACKGROUND:Laser Interstitial ThermoTherapy (LITT) is a well established surgical method. The use of LITT is so far limited to homogeneous tissues, e.g. the liver. One of the reasons is the limited capability of existing treatment planning models to calculate accurately the damage zone. The treatment planning in inhomo...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/1475-925X-4-2
更新日期:2005-01-04 00:00:00
abstract:BACKGROUND:Areas with high frequency activity within the atrium are thought to be 'drivers' of the rhythm in patients with atrial fibrillation (AF) and ablation of these areas seems to be an effective therapy in eliminating DF gradient and restoring sinus rhythm. Clinical groups have applied the traditional FFT-based a...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/s12938-016-0143-8
更新日期:2016-03-08 00:00:00
abstract:INTRODUCTION:This paper concerns the analysis of the features obtained from thyroid ultrasound images in left and right transverse and longitudinal sections. In the image analysis, the thyroid lobe is treated as a texture for healthy subjects and patients with Hashimoto's disease. The applied methods of analysis and im...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/1475-925X-11-48
更新日期:2012-08-16 00:00:00
abstract:BACKGROUND:Image quality assessment method of photoacoustic tomography has not been completely standardized yet. Due to the combined nature of photonic signal generation and ultrasonic signal transmission in biological tissue, neither optical nor ultrasonic traditional methods can be used without modification. An optic...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/1475-925X-11-37
更新日期:2012-07-13 00:00:00
abstract:BACKGROUND:Stroke is one of the major causes of morbidity and mortality. Its recovery and treatment depends on close clinical monitoring by a clinician especially during the first few hours after the onset of stroke. Patients who do not exhibit early motor recovery post thrombolysis may benefit from more aggressive tre...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/1475-925X-12-33
更新日期:2013-04-16 00:00:00
abstract:BACKGROUND:Understanding the mechanical properties of the iris can help to have an insight into the eye diseases with abnormalities of the iris morphology. Material parameters of the iris were simply calculated relying on the ex vivo experiment. However, the mechanical response of the iris in vivo is different from tha...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/1475-925X-13-66
更新日期:2014-05-30 00:00:00
abstract:BACKGROUND:The pupillary light reflex characterizes the direct and consensual response of the eye to the perceived brightness of a stimulus. It has been used as indicator of both neurological and optic nerve pathologies. As with other eye reflexes, this reflex constitutes an almost instantaneous movement and is linked ...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/s12938-015-0016-6
更新日期:2015-03-13 00:00:00
abstract:BACKGROUND AND AIMS:People with internet addiction (IA) suffer from mental, physical, social, and occupational problems. IA includes psychological and physiological syndromes, and among the syndromes, emotion was suggested important mental and physiological expressions of IA. However, few physiologically emotional char...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/s12938-016-0201-2
更新日期:2016-07-04 00:00:00
abstract:BACKGROUND:Aging has been shown to slow reflexes and increase reaction time to varied stimuli. However, the effect of Type II diabetes on these same reaction times has not been reported. Diabetes affects peripheral nerves in the somatosensory and auditory system, slows psychomotor responses, and has cognitive effects o...
journal_title:Biomedical engineering online
pub_type: 临床试验,杂志文章
doi:10.1186/1475-925X-4-12
更新日期:2005-02-21 00:00:00
abstract:BACKGROUND:Concerns about the cost-effectiveness of invasive hemodynamic monitoring in critically ill patients using pulmonary artery catheters motivate a renewed search for effective noninvasive methods to measure stroke volume. This paper explores a new approach based on noninvasively measured pulse wave velocity, pu...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/1475-925X-13-137
更新日期:2014-09-19 00:00:00