Computational studies of the effects of myocardial blood flow reductions on cardiac metabolism.

Abstract:

BACKGROUND:A computational model of myocardial energy metabolism was used to assess the metabolic responses to normal and reduced myocardial blood flow. The goal was to examine to what extent glycolysis and lactate formation are controlled by the supply of glycolytic substrate and/or the cellular redox (NADH/NAD+) and phosphorylation (ATP/ADP) states. METHODS:Flow was reduced over a wide range and for a sufficient duration in order to investigate the sequence of events that occur during the transition to a new metabolic steady state. RESULTS:Simulation results indicated multiple time-dependent controls over both glycolysis and lactate formation. CONCLUSIONS:Changes in phosphorylation state and glucose uptake only significantly affect the initial phase of the glycolytic response to ischemia, while glycogen breakdown exerts control over glycolysis during the entire duration of ischemia. Similarly, changes in the redox state affect the rates of lactate formation and release primarily during the initial transient phase of the response to the reductions in blood flow, while the rate of glycolysis controls the rate of lactate formation throughout the entire period of adaptation.

journal_name

Biomed Eng Online

authors

Salem JE,Stanley WC,Cabrera ME

doi

10.1186/1475-925X-3-15

keywords:

subject

Has Abstract

pub_date

2004-06-02 00:00:00

pages

15

issue

1

issn

1475-925X

pii

1475-925X-3-15

journal_volume

3

pub_type

杂志文章
  • Automatic QRS complex detection using two-level convolutional neural network.

    abstract:BACKGROUND:The QRS complex is the most noticeable feature in the electrocardiogram (ECG) signal, therefore, its detection is critical for ECG signal analysis. The existing detection methods largely depend on hand-crafted manual features and parameters, which may introduce significant computational complexity, especiall...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-018-0441-4

    authors: Xiang Y,Lin Z,Meng J

    更新日期:2018-01-29 00:00:00

  • Hemodynamic numerical simulations of the disturbance due to intracoronary flow measurements by a Doppler guide wire.

    abstract:BACKGROUND:Since hemodynamics plays a key role in the development and evolution of cardiovascular pathologies, physician's decision must be based on proper monitoring of relevant physiological flow quantities. METHODS:A numerical analysis of the error introduced by an intravascular Doppler guide wire on the peak veloc...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-016-0234-6

    authors: Chodzyński KJ,Gremmo S,Eker OF,Lalmand J,Aminian A,de Sousa DR,Boudjeltia KZ,Coussement G

    更新日期:2016-10-10 00:00:00

  • Translational-circular scanning for magneto-acoustic tomography with current injection.

    abstract:BACKGROUND:Magneto-acoustic tomography with current injection involves using electrical impedance imaging technology. To explore the potential applications in imaging biological tissue and enhance image quality, a new scan mode for the transducer is proposed that is based on translational and circular scanning to recor...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-016-0125-x

    authors: Wang S,Ma R,Zhang S,Yin T,Liu Z

    更新日期:2016-01-27 00:00:00

  • Unsupervised machine-learning method for improving the performance of ambulatory fall-detection systems.

    abstract:BACKGROUND:Falls can cause trauma, disability and death among older people. Ambulatory accelerometer devices are currently capable of detecting falls in a controlled environment. However, research suggests that most current approaches can tend to have insufficient sensitivity and specificity in non-laboratory environme...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-11-9

    authors: Yuwono M,Moulton BD,Su SW,Celler BG,Nguyen HT

    更新日期:2012-02-16 00:00:00

  • Assessment of nonnegative matrix factorization algorithms for electroencephalography spectral analysis.

    abstract:BACKGROUND:Nonnegative matrix factorization (NMF) has been successfully used for electroencephalography (EEG) spectral analysis. Since NMF was proposed in the 1990s, many adaptive algorithms have been developed. However, the performance of their use in EEG data analysis has not been fully compared. Here, we provide a c...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-020-00796-x

    authors: Hu G,Zhou T,Luo S,Mahini R,Xu J,Chang Y,Cong F

    更新日期:2020-07-31 00:00:00

  • Risk and reward: extending stochastic glycaemic control intervals to reduce workload.

    abstract:BACKGROUND:STAR is a model-based, personalised, risk-based dosing approach for glycaemic control (GC) in critically ill patients. STAR provides safe, effective control to nearly all patients, using 1-3 hourly measurement and intervention intervals. However, the average 11-12 measurements per day required can be a clini...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-020-00771-6

    authors: Uyttendaele V,Knopp JL,Shaw GM,Desaive T,Chase JG

    更新日期:2020-04-29 00:00:00

  • A computational model study of the influence of the anatomy of the circle of willis on cerebral hyperperfusion following carotid artery surgery.

    abstract:BACKGROUND:Cerebral hyperperfusion syndrome develops in a small subset of patients following carotid artery surgery (CAS) performed to treat severe carotid artery stenosis. This syndrome has been found to have a close correlation with cerebral hyperperfusion occurring after CAS. The purpose of this study is to investig...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-10-84

    authors: Liang F,Fukasaku K,Liu H,Takagi S

    更新日期:2011-09-23 00:00:00

  • The effect of inlet and outlet boundary conditions in image-based CFD modeling of aortic flow.

    abstract:BACKGROUND:Computational modeling of cardiovascular flow is a growing and useful field, but such simulations usually require the researcher to guess the flow's inlet and outlet conditions since they are difficult and expensive to measure. It is critical to determine the amount of uncertainty introduced by these assumpt...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-018-0497-1

    authors: Madhavan S,Kemmerling EMC

    更新日期:2018-05-30 00:00:00

  • Formulation of photon diffusion from spherical bioluminescent sources in an infinite homogeneous medium.

    abstract:BACKGROUND:The bioluminescent enzyme firefly luciferase (Luc) or variants of green fluorescent protein (GFP) in transformed cells can be effectively used to reveal molecular and cellular features of neoplasia in vivo. Tumor cell growth and regression in response to various therapies can be evaluated by using biolumines...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-3-12

    authors: Cong W,Wang LV,Wang G

    更新日期:2004-05-04 00:00:00

  • Correlations between carotid plaque progression and mechanical stresses change sign over time: a patient follow up study using MRI and 3D FSI models.

    abstract:BACKGROUND:Increasing evidence suggests that mechanisms governing advanced plaque progression may be different from those for early progression and require further investigation. Serial MRI data and 3D fluid-structure interaction (FSI) models were employed to identify possible correlations between mechanical stresses a...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-12-105

    authors: Tang D,Yang C,Canton G,Wu Z,Hatsukami T,Yuan C

    更新日期:2013-10-14 00:00:00

  • Dendritic tree extraction from noisy maximum intensity projection images in C. elegans.

    abstract:BACKGROUND:Maximum Intensity Projections (MIP) of neuronal dendritic trees obtained from confocal microscopy are frequently used to study the relationship between tree morphology and mechanosensory function in the model organism C. elegans. Extracting dendritic trees from noisy images remains however a strenuous proces...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-13-74

    authors: Greenblum A,Sznitman R,Fua P,Arratia PE,Oren M,Podbilewicz B,Sznitman J

    更新日期:2014-06-12 00:00:00

  • NeoAnalysis: a Python-based toolbox for quick electrophysiological data processing and analysis.

    abstract:BACKGROUND:In a typical electrophysiological experiment, especially one that includes studying animal behavior, the data collected normally contain spikes, local field potentials, behavioral responses and other associated data. In order to obtain informative results, the data must be analyzed simultaneously with the ex...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-017-0419-7

    authors: Zhang B,Dai J,Zhang T

    更新日期:2017-11-13 00:00:00

  • Improved content aware scene retargeting for retinitis pigmentosa patients.

    abstract:BACKGROUND:In this paper we present a novel scene retargeting technique to reduce the visual scene while maintaining the size of the key features. The algorithm is scalable to implementation onto portable devices, and thus, has potential for augmented reality systems to provide visual support for those with tunnel visi...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-9-52

    authors: Al-Atabany WI,Tong T,Degenaar PA

    更新日期:2010-09-16 00:00:00

  • Home-based system for physical activity monitoring in patients with multiple sclerosis (Pilot study).

    abstract:BACKGROUND:Limitations in physical activity are considered as a key problem in patients with multiple sclerosis (PwMS). Contemporary methods to assess the level of physical activity in PwMS are regular clinical observation. However, these methods either rely on high recall and accurate reporting from the patients (e.g....

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-13-10

    authors: Shammas L,Zentek T,von Haaren B,Schlesinger S,Hey S,Rashid A

    更新日期:2014-02-06 00:00:00

  • Noninvasive measurement of cardiac stroke volume using pulse wave velocity and aortic dimensions: a simulation study.

    abstract:BACKGROUND:Concerns about the cost-effectiveness of invasive hemodynamic monitoring in critically ill patients using pulmonary artery catheters motivate a renewed search for effective noninvasive methods to measure stroke volume. This paper explores a new approach based on noninvasively measured pulse wave velocity, pu...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-13-137

    authors: Babbs CF

    更新日期:2014-09-19 00:00:00

  • Safety assessment of near infrared light emitting diodes for diffuse optical measurements.

    abstract:BACKGROUND:Near infrared (NIR) light has been used widely to monitor important hemodynamic parameters in tissue non-invasively. Pulse oximetry, near infrared spectroscopy, and diffuse optical tomography are examples of such NIR light-based applications. These and other similar applications employ either lasers or light...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-3-9

    authors: Bozkurt A,Onaral B

    更新日期:2004-03-22 00:00:00

  • Evolutionary optimization of classifiers and features for single-trial EEG discrimination.

    abstract:BACKGROUND:State-of-the-art signal processing methods are known to detect information in single-trial event-related EEG data, a crucial aspect in development of real-time applications such as brain computer interfaces. This paper investigates one such novel approach, evaluating how individual classifier and feature sub...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-6-32

    authors: Aberg MC,Wessberg J

    更新日期:2007-08-23 00:00:00

  • In vivo and in vitro performance of a China-made hemodialysis machine: a multi-center prospective controlled study.

    abstract:OBJECTIVE:To evaluate the in vivo and in vitro performance of a China-made dialysis machine (SWS-4000). METHODS:This was a multi-center prospective controlled study consisting of both long-term in vitro evaluations and cross-over in vivo tests in 132 patients. The China-made SWS-4000 dialysis machine was compared with...

    journal_title:Biomedical engineering online

    pub_type: 临床试验,杂志文章,多中心研究

    doi:10.1186/s12938-017-0387-y

    authors: Wang Y,Chen XM,Cai GY,Li WG,Zhang AH,Hao LR,Shi M,Wang R,Jiang HL,Luo HM,Zhang D,Sun XF

    更新日期:2017-08-02 00:00:00

  • Multi-objective optimization of coronary stent using Kriging surrogate model.

    abstract:BACKGROUND:In stent design optimization, the functional relationship between design parameters and design goals is nonlinear, complex, and implicit and the multi-objective design of stents involves a number of potentially conflicting performance criteria. Therefore it is hard and time-consuming to find the optimal desi...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-016-0268-9

    authors: Li H,Gu J,Wang M,Zhao D,Li Z,Qiao A,Zhu B

    更新日期:2016-12-28 00:00:00

  • Objective assessment of spasticity by pendulum test: a systematic review on methods of implementation and outcome measures.

    abstract:BACKGROUND:Instrumented pendulum test is an objective and repeatable biomechanical method of assessment for spasticity. However, multitude of sensor technologies and plenty of suggested outcome measures, confuse those interested in implementing this method in practice. Lack of a standard agreement on the definition of ...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章,评审

    doi:10.1186/s12938-020-00826-8

    authors: Rahimi F,Eyvazpour R,Salahshour N,Azghani MR

    更新日期:2020-11-09 00:00:00

  • Cardiac arrhythmia classification using autoregressive modeling.

    abstract:BACKGROUND:Computer-assisted arrhythmia recognition is critical for the management of cardiac disorders. Various techniques have been utilized to classify arrhythmias. Generally, these techniques classify two or three arrhythmias or have significantly large processing times. A simpler autoregressive modeling (AR) techn...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925x-1-5

    authors: Ge D,Srinivasan N,Krishnan SM

    更新日期:2002-11-13 00:00:00

  • Temporal fluctuations of tremor signals from inertial sensor: a preliminary study in differentiating Parkinson's disease from essential tremor.

    abstract:BACKGROUND:Parkinson's disease (PD) and essential tremor (ET) are the two most common movement disorders but the rate of misdiagnosis rate in these disorders is high due to similar characteristics of tremor. The purpose of the study is to present: (a) a solution to identify PD and ET patients by using the novel measure...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-015-0098-1

    authors: Thanawattano C,Pongthornseri R,Anan C,Dumnin S,Bhidayasiri R

    更新日期:2015-11-04 00:00:00

  • Phantom-based experimental validation of fast virtual deployment of self-expandable stents for cerebral aneurysms.

    abstract:BACKGROUND:Endovascular intervention using a stent is a mainstream treatment for cerebral aneurysms. To assess the effect of intervention strategies on aneurysm hemodynamics, we have developed a fast virtual stenting (FVS) technique to simulate stent deployment in patient-specific aneurysms. However, quantitative valid...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-016-0250-6

    authors: Zhang Q,Meng Z,Zhang Y,Yao K,Liu J,Zhang Y,Jing L,Yang X,Paliwal N,Meng H,Wang S

    更新日期:2016-12-28 00:00:00

  • A portable system with sample rate of 250 Hz for characterization of knee and hip angles in the sagittal plane during gait.

    abstract:BACKGROUND:Gait analysis and research have been developed to obtain characteristics of movement patterns of people while walking. However, traditional measuring systems present different drawbacks that reduce their use and application. Among those drawbacks one can find: high price, low sampling frequency and limiting ...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-13-34

    authors: Martínez-Solís F,Claudio-Sánchez A,Rodríguez-Lelis JM,Vergara-Limon S,Olivares-Peregrino V,Vargas-Treviño M

    更新日期:2014-03-31 00:00:00

  • 16-Channel biphasic current-mode programmable charge balanced neural stimulation.

    abstract:BACKGROUND:Neural stimulation is an important method used to activate or inhibit action potentials of the neuronal anatomical targets found in the brain, central nerve and peripheral nerve. The neural stimulator system produces biphasic pulses that deliver balanced charge into tissue from single or multichannel electro...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-017-0385-0

    authors: Li X,Zhong S,Morizio J

    更新日期:2017-08-14 00:00:00

  • Why brain-controlled neuroprosthetics matter: mechanisms underlying electrical stimulation of muscles and nerves in rehabilitation.

    abstract::Delivering short trains of electric pulses to the muscles and nerves can elicit action potentials resulting in muscle contractions. When the stimulations are sequenced to generate functional movements, such as grasping or walking, the application is referred to as functional electrical stimulation (FES). Implications ...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章,评审

    doi:10.1186/s12938-020-00824-w

    authors: Milosevic M,Marquez-Chin C,Masani K,Hirata M,Nomura T,Popovic MR,Nakazawa K

    更新日期:2020-11-04 00:00:00

  • Non-viral eNOS gene delivery and transfection with stents for the treatment of restenosis.

    abstract:BACKGROUND:In this study, we have examined local non-viral gene delivery, transfection, and therapeutic efficacy of endothelial nitric oxide synthase (eNOS) encoding plasmid DNA administered using coated stents in a rabbit iliac artery restenosis model. METHODS:Lipopolyplexes (LPPs) with eNOS expressing plasmid DNA we...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-9-56

    authors: Brito LA,Chandrasekhar S,Little SR,Amiji MM

    更新日期:2010-09-27 00:00:00

  • Review of cognitive behavioural therapy mobile apps using a reference architecture embedded in the patient-provider relationship.

    abstract:BACKGROUND:Mobile health apps (mHealth apps) are increasing in popularity and utility for the management of many chronic diseases. Although the current reimbursement structure for mHealth apps is lagging behind the rapidly improving functionality, more clinicians will begin to recommend these apps as they prove their c...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-018-0611-4

    authors: Lan A,Lee A,Munroe K,McRae C,Kaleis L,Keshavjee K,Guergachi A

    更新日期:2018-12-17 00:00:00

  • Public access defibrillation: suppression of 16.7 Hz interference generated by the power supply of the railway systems.

    abstract:BACKGROUND:A specific problem using the public access defibrillators (PADs) arises at the railway stations. Some countries as Germany, Austria, Switzerland, Norway and Sweden are using AC railroad net power-supply system with rated 16.7 Hz frequency modulated from 15.69 Hz to 17.36 Hz. The power supply frequency contam...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-4-16

    authors: Christov II,Iliev GL

    更新日期:2005-03-15 00:00:00

  • Novel dynamic corneal response parameters in a practice use: a critical review.

    abstract:BACKGROUND:Non-contact tonometers based on the method using air puff and Scheimpflug's fast camera are one of the latest devices allowing the measurement of intraocular pressure and additional biomechanical parameters of the cornea. Biomechanical features significantly affect changes in intraocular pressure values, as ...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章,评审

    doi:10.1186/s12938-019-0636-3

    authors: Jędzierowska M,Koprowski R

    更新日期:2019-02-13 00:00:00