Abstract:
BACKGROUND:The electroencephalography (EEG) signals are known to involve the firings of neurons in the brain. The P300 wave is a high potential caused by an event-related stimulus. The detection of P300s included in the measured EEG signals is widely investigated. The difficulties in detecting them are that they are mixed with other signals generated over a large brain area and their amplitudes are very small due to the distance and resistivity differences in their transmittance. METHODS:A novel real-time feature extraction method for detecting P300 waves by combining an adaptive nonlinear principal component analysis (ANPCA) and a multilayer neural network is proposed. The measured EEG signals are first filtered using a sixth-order band-pass filter with cut-off frequencies of 1 Hz and 12 Hz. The proposed ANPCA scheme consists of four steps: pre-separation, whitening, separation, and estimation. In the experiment, four different inter-stimulus intervals (ISIs) are utilized: 325 ms, 350 ms, 375 ms, and 400 ms. RESULTS:The developed multi-stage principal component analysis method applied at the pre-separation step has reduced the external noises and artifacts significantly. The introduced adaptive law in the whitening step has made the subsequent algorithm in the separation step to converge fast. The separation performance index has varied from -20 dB to -33 dB due to randomness of source signals. The robustness of the ANPCA against background noises has been evaluated by comparing the separation performance indices of the ANPCA with four algorithms (NPCA, NSS-JD, JADE, and SOBI), in which the ANPCA algorithm demonstrated the shortest iteration time with performance index about 0.03. Upon this, it is asserted that the ANPCA algorithm successfully separates mixed source signals. CONCLUSIONS:The independent components produced from the observed data using the proposed method illustrated that the extracted signals were clearly the P300 components elicited by task-related stimuli. The experiment using 350 ms ISI showed the best performance. Since the proposed method does not use down-sampling and averaging, it can be used as a viable tool for real-time clinical applications.
journal_name
Biomed Eng Onlinejournal_title
Biomedical engineering onlineauthors
Turnip A,Hong KS,Jeong MYdoi
10.1186/1475-925X-10-83subject
Has Abstractpub_date
2011-09-23 00:00:00pages
83issn
1475-925Xpii
1475-925X-10-83journal_volume
10pub_type
杂志文章abstract::A large number of incommensurable metrics are currently used to report the performance of brain-computer interfaces (BCI) used for augmentative and alterative communication (AAC). The lack of standard metrics precludes the comparison of different BCI-based AAC systems, hindering rapid growth and development of this te...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/1475-925X-12-43
更新日期:2013-05-16 00:00:00
abstract:BACKGROUND:Studies found that treatment symptoms of concern to oncology/hematology patients were greatly under-identified in medical records. On average, 11.0 symptoms were reported of concern to patients compared to 1.5 symptoms identified in their medical records. A solution to this problem is use of an electronic sy...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/1475-925X-14-S2-S1
更新日期:2015-01-01 00:00:00
abstract:BACKGROUND:Fiber-based optical spectroscopy has been widely used for biomedical applications. However, the effect of probe-sample distance on the collection efficiency has not been well investigated. METHOD:In this paper, we presented a theoretical model to maximize the illumination and collection efficiency in design...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/1475-925X-10-95
更新日期:2011-11-02 00:00:00
abstract:OBJECTIVE:To evaluate the in vivo and in vitro performance of a China-made dialysis machine (SWS-4000). METHODS:This was a multi-center prospective controlled study consisting of both long-term in vitro evaluations and cross-over in vivo tests in 132 patients. The China-made SWS-4000 dialysis machine was compared with...
journal_title:Biomedical engineering online
pub_type: 临床试验,杂志文章,多中心研究
doi:10.1186/s12938-017-0387-y
更新日期:2017-08-02 00:00:00
abstract:BACKGROUND:Understanding aneurysm growth rate allows us to predict not only the current rupture risk, but also accumulated rupture risk in the future. However, determining growth rate of unruptured intracranial aneurysms often requires follow-up of patients for a long period of time so that significant growth can be ob...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/1475-925X-8-11
更新日期:2009-06-18 00:00:00
abstract:BACKGROUND:Pre-operative imaging devices generate high-resolution images but intra-operative imaging devices generate low-resolution images. To use high-resolution pre-operative images during surgery, they must be deformed to reflect intra-operative geometry of brain. METHODS:We employ biomechanical models, guided by ...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/1475-925X-9-51
更新日期:2010-09-15 00:00:00
abstract::The control of robotic prostheses based on pattern recognition algorithms is a widely studied subject that has shown promising results in acute experiments. The long-term implementation of this technology, however, has not yet been achieved due to practical issues that can be mainly attributed to the use of surface el...
journal_title:Biomedical engineering online
pub_type: 杂志文章,评审
doi:10.1186/1475-925X-11-33
更新日期:2012-06-20 00:00:00
abstract:BACKGROUND:Good anatomical compatibility is an important aspect in the development of cardiovascular implants. This work analyzes the interaction of the pump unit of an electrically driven pulsatile Total Artificial Heart (TAH) and the mediastinum. For an adequate compliance, both overall dimensions and alignment of in...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/1475-925X-12-81
更新日期:2013-08-14 00:00:00
abstract:BACKGROUND:Monitoring of vital parameters is an important topic in neonatal daily care. Progress in computational intelligence and medical sensors has facilitated the development of smart bedside monitors that can integrate multiple parameters into a single monitoring system. This paper describes non-contact monitoring...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/1475-925X-10-93
更新日期:2011-10-20 00:00:00
abstract:BACKGROUND:Muscle fiber orientation (MFO) is an important parameter related to musculoskeletal functions. The traditional manual method for MFO estimation in sonograms was labor-intensive. The automatic methods proposed in recent years also involved voting procedures which were computationally expensive. METHODS:In th...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/1475-925X-12-98
更新日期:2013-09-30 00:00:00
abstract:BACKGROUND:Robot-based joint-testing systems (RJTS) can be used to perform unconstrained laxity tests, measuring the stiffness of a degree of freedom (DOF) of the joint at a fixed flexion angle while allowing the other DOFs unconstrained movement. Previous studies using the force-position hybrid (FPH) control method pr...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/s12938-016-0195-9
更新日期:2016-06-07 00:00:00
abstract:BACKGROUND:Near infrared (NIR) light has been used widely to monitor important hemodynamic parameters in tissue non-invasively. Pulse oximetry, near infrared spectroscopy, and diffuse optical tomography are examples of such NIR light-based applications. These and other similar applications employ either lasers or light...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/1475-925X-3-9
更新日期:2004-03-22 00:00:00
abstract:BACKGROUND:The replacement of hard tissues demands biocompatible and sometimes bioactive materials with properties similar to those of bone. Nano-composites made of biocompatible polymers and bioactive inorganic nano particles such as HDPE/HA have attracted attention as permanent bone substitutes due to their excellent...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/1475-925X-12-95
更新日期:2013-09-24 00:00:00
abstract:BACKGROUND:Laser Interstitial ThermoTherapy (LITT) is a well established surgical method. The use of LITT is so far limited to homogeneous tissues, e.g. the liver. One of the reasons is the limited capability of existing treatment planning models to calculate accurately the damage zone. The treatment planning in inhomo...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/1475-925X-4-2
更新日期:2005-01-04 00:00:00
abstract:BACKGROUND:Entropy analysis has been attracting increasing attentions in the recent two or three decades. It assesses complexity, or irregularity, of time-series which is extraordinarily relevant to physiology and diseases as demonstrated by tremendous studies. However, the complexity can hardly be appreciated by tradi...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/s12938-019-0650-5
更新日期:2019-03-20 00:00:00
abstract:BACKGROUND:State-of-the-art signal processing methods are known to detect information in single-trial event-related EEG data, a crucial aspect in development of real-time applications such as brain computer interfaces. This paper investigates one such novel approach, evaluating how individual classifier and feature sub...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/1475-925X-6-32
更新日期:2007-08-23 00:00:00
abstract:BACKGROUND AND AIMS:People with internet addiction (IA) suffer from mental, physical, social, and occupational problems. IA includes psychological and physiological syndromes, and among the syndromes, emotion was suggested important mental and physiological expressions of IA. However, few physiologically emotional char...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/s12938-016-0201-2
更新日期:2016-07-04 00:00:00
abstract::Delivering short trains of electric pulses to the muscles and nerves can elicit action potentials resulting in muscle contractions. When the stimulations are sequenced to generate functional movements, such as grasping or walking, the application is referred to as functional electrical stimulation (FES). Implications ...
journal_title:Biomedical engineering online
pub_type: 杂志文章,评审
doi:10.1186/s12938-020-00824-w
更新日期:2020-11-04 00:00:00
abstract:BACKGROUND:Neural stimulation is an important method used to activate or inhibit action potentials of the neuronal anatomical targets found in the brain, central nerve and peripheral nerve. The neural stimulator system produces biphasic pulses that deliver balanced charge into tissue from single or multichannel electro...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/s12938-017-0385-0
更新日期:2017-08-14 00:00:00
abstract:BACKGROUND:A computational model of myocardial energy metabolism was used to assess the metabolic responses to normal and reduced myocardial blood flow. The goal was to examine to what extent glycolysis and lactate formation are controlled by the supply of glycolytic substrate and/or the cellular redox (NADH/NAD+) and ...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/1475-925X-3-15
更新日期:2004-06-02 00:00:00
abstract:BACKGROUND:It is generally accepted that cartilage adaptation and degeneration are mechanically mediated. Investigating the swelling behaviour of cartilage is important because the stress and strain state of cartilage is associated with the swelling and deformation behaviour. It is well accepted that the swelling of so...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/1475-925x-1-8
更新日期:2002-12-19 00:00:00
abstract:BACKGROUND:Mobile health apps (mHealth apps) are increasing in popularity and utility for the management of many chronic diseases. Although the current reimbursement structure for mHealth apps is lagging behind the rapidly improving functionality, more clinicians will begin to recommend these apps as they prove their c...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/s12938-018-0611-4
更新日期:2018-12-17 00:00:00
abstract:BACKGROUND:The myocardium exhibits heterogeneous nature due to scarring after Myocardial Infarction (MI). In Cardiac Magnetic Resonance (CMR) imaging, Late Gadolinium (LG) contrast agent enhances the intensity of scarred area in the myocardium. METHODS:In this paper, we propose a probability mapping technique using Te...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/1475-925X-12-91
更新日期:2013-09-22 00:00:00
abstract:BACKGROUND:The lumbar range of motion has traditionally been used to assess disability in patients with low back disorders. Controversy exists about how movement ranges in static positions or in a single straight plane is related to the functional status of the patients. The trunk circumduction, as the result of neurom...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/1475-925X-12-4
更新日期:2013-01-11 00:00:00
abstract:BACKGROUND:In magnetic resonance electrical impedance tomography (MREIT), we reconstruct conductivity images using magnetic flux density data induced by externally injected currents. Since we extract magnetic flux density data from acquired MR phase images, the amount of measurement noise increases in regions of weak M...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/1475-925X-13-87
更新日期:2014-06-26 00:00:00
abstract:BACKGROUND:Falls can cause trauma, disability and death among older people. Ambulatory accelerometer devices are currently capable of detecting falls in a controlled environment. However, research suggests that most current approaches can tend to have insufficient sensitivity and specificity in non-laboratory environme...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/1475-925X-11-9
更新日期:2012-02-16 00:00:00
abstract:BACKGROUND:Increasing evidence suggests that mechanisms governing advanced plaque progression may be different from those for early progression and require further investigation. Serial MRI data and 3D fluid-structure interaction (FSI) models were employed to identify possible correlations between mechanical stresses a...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/1475-925X-12-105
更新日期:2013-10-14 00:00:00
abstract:BACKGROUND:In ultrasound imaging systems, the digital transmit beamformer is a critical module that generates accurate control over several transmission parameters. However, such transmit front-end module is not typically accessible to ultrasound researchers. To overcome this difficulty, we have been developing a compa...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/1475-925X-12-24
更新日期:2013-03-20 00:00:00
abstract:BACKGROUND:In stent design optimization, the functional relationship between design parameters and design goals is nonlinear, complex, and implicit and the multi-objective design of stents involves a number of potentially conflicting performance criteria. Therefore it is hard and time-consuming to find the optimal desi...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/s12938-016-0268-9
更新日期:2016-12-28 00:00:00
abstract:BACKGROUND:This study investigates CAD/CAM ceramic cusp-replacing restoration resistance with and without buccal cusp replacement under static and dynamic cyclic loads, monitored using the acoustic emission (AE) technique. METHOD:The cavity was designed in a typical MODP (mesial-occlusal-distal-palatal) restoration fa...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/1475-925X-13-165
更新日期:2014-12-13 00:00:00