Review of cognitive behavioural therapy mobile apps using a reference architecture embedded in the patient-provider relationship.

Abstract:

BACKGROUND:Mobile health apps (mHealth apps) are increasing in popularity and utility for the management of many chronic diseases. Although the current reimbursement structure for mHealth apps is lagging behind the rapidly improving functionality, more clinicians will begin to recommend these apps as they prove their clinical worth. Payors such as the government or private insurance companies will start to reimburse for the use of these technologies, especially if they add value to patients by providing timely support, a more streamlined patient experience, and greater patient convenience. Payors are likely to see benefits for providers, as these apps could help increase productivity between in-office encounters without having to resort to expensive in-person visits when patients are having trouble managing their disease. KEY FINDINGS:To guide and perhaps speed up adoption of mHealth apps by patients and providers, analysis and evaluation of existing apps needs to be carried out and more feedback must be provided to app developers. In this paper, an evaluation of 35 mHealth apps claiming to provide cognitive behavioural therapy was conducted to assess the quality of the patient-provider relationship and evidence-based practices embedded in these apps. The mean score across the apps was 4.9 out of 20 functional criteria all of which were identified as important to the patient-provider relationship. The median score was 5 out of these 20 functional criteria. CONCLUSION:Overall, the apps reviewed were mostly stand-alone apps that do not enhance the patient-provider relationship, improve patient accountability or help providers support patients more effectively between visits. Large improvements in patient experience and provider productivity can be made through enhanced integration of mHealth apps into the healthcare system.

journal_name

Biomed Eng Online

authors

Lan A,Lee A,Munroe K,McRae C,Kaleis L,Keshavjee K,Guergachi A

doi

10.1186/s12938-018-0611-4

subject

Has Abstract

pub_date

2018-12-17 00:00:00

pages

183

issue

1

issn

1475-925X

pii

10.1186/s12938-018-0611-4

journal_volume

17

pub_type

杂志文章
  • Automatic lumen segmentation in IVOCT images using binary morphological reconstruction.

    abstract:BACKGROUND:Atherosclerosis causes millions of deaths, annually yielding billions in expenses round the world. Intravascular Optical Coherence Tomography (IVOCT) is a medical imaging modality, which displays high resolution images of coronary cross-section. Nonetheless, quantitative information can only be obtained with...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-12-78

    authors: Moraes MC,Cardenas DA,Furuie SS

    更新日期:2013-08-09 00:00:00

  • Application safety evaluation of the radio frequency identification tag under magnetic resonance imaging.

    abstract:BACKGROUND:Radio Frequency Identification(RFID) has been widely used in healthcare facilities, but it has been paid little attention whether RFID applications are safe enough under healthcare environment. The purpose of this study is to assess the effects of RFID tags on Magnetic Resonance (MR) imaging in a typical ele...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-13-129

    authors: Fei X,Li S,Gao S,Wei L,Wang L

    更新日期:2014-09-04 00:00:00

  • Heart rate analysis in normal subjects of various age groups.

    abstract:BACKGROUND:Analysis of heart rate variation (HRV) has become a popular noninvasive tool for assessing the activities of the autonomic nervous system (ANS). HRV analysis is based on the concept that fast fluctuations may specifically reflect changes of sympathetic and vagal activity. It shows that the structure generati...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-3-24

    authors: Acharya U R,Kannathal N,Sing OW,Ping LY,Chua T

    更新日期:2004-07-20 00:00:00

  • Effects of 8-week swimming training on carotid arterial stiffness and hemodynamics in young overweight adults.

    abstract:BACKGROUND:Exercise has been found to either reduce or increase arterial stiffness. Land-based exercise modalities have been documented as effective physical therapies to decrease arterial stiffness. However, these land-based exercise modalities may not be suitable for overweight individuals, in terms of risks of joint...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-016-0274-y

    authors: Yuan WX,Liu HB,Gao FS,Wang YX,Qin KR

    更新日期:2016-12-28 00:00:00

  • Characterization of the head-to-trunk orientation with handheld optical 3D apparatus based on the fringe projection technique.

    abstract:BACKGROUND:Knowing the orientation of the head is important in many fields, including medicine. Many methods and measuring systems exist, but usually they use different markers or sensors attached to the subject's head for head orientation determination. In certain applications these attachments may represent a burden ...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-12-96

    authors: Pavlovčič U,Diaci J,Možina J,Jezeršek M

    更新日期:2013-09-26 00:00:00

  • Computational fluid dynamics simulations of blood flow regularized by 3D phase contrast MRI.

    abstract:BACKGROUND:Phase contrast magnetic resonance imaging (PC-MRI) is used clinically for quantitative assessment of cardiovascular flow and function, as it is capable of providing directly-measured 3D velocity maps. Alternatively, vascular flow can be estimated from model-based computation fluid dynamics (CFD) calculations...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-015-0104-7

    authors: Rispoli VC,Nielsen JF,Nayak KS,Carvalho JL

    更新日期:2015-11-26 00:00:00

  • An improved level set method for vertebra CT image segmentation.

    abstract:BACKGROUND:Clinical diagnosis and therapy for the lumbar disc herniation requires accurate vertebra segmentation. The complex anatomical structure and the degenerative deformations of the vertebrae makes its segmentation challenging. METHODS:An improved level set method, namely edge- and region-based level set method ...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-12-48

    authors: Huang J,Jian F,Wu H,Li H

    更新日期:2013-05-28 00:00:00

  • Temporal fluctuations of tremor signals from inertial sensor: a preliminary study in differentiating Parkinson's disease from essential tremor.

    abstract:BACKGROUND:Parkinson's disease (PD) and essential tremor (ET) are the two most common movement disorders but the rate of misdiagnosis rate in these disorders is high due to similar characteristics of tremor. The purpose of the study is to present: (a) a solution to identify PD and ET patients by using the novel measure...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-015-0098-1

    authors: Thanawattano C,Pongthornseri R,Anan C,Dumnin S,Bhidayasiri R

    更新日期:2015-11-04 00:00:00

  • Extraction of average neck flexion angle during swallowing in neutral and chin-tuck positions.

    abstract:BACKGROUND:A common but debated technique in the management of swallowing difficulties is the chin tuck swallow, where the neck is flexed forward prior to swallowing. Natural variations in chin tuck angles across individuals may contribute to the differential effectiveness of the technique. METHODOLOGY:To facilitate t...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-8-25

    authors: Hung D,Sejdić E,Steele CM,Chau T

    更新日期:2009-10-07 00:00:00

  • Developing functional workspace for the movement of trunk circumduction in healthy young subjects: a reliability study.

    abstract:BACKGROUND:The lumbar range of motion has traditionally been used to assess disability in patients with low back disorders. Controversy exists about how movement ranges in static positions or in a single straight plane is related to the functional status of the patients. The trunk circumduction, as the result of neurom...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-12-4

    authors: Cheng SC,Hsu CH,Ting YT,Kuo LC,Lin RM,Su FC

    更新日期:2013-01-11 00:00:00

  • Monitoring and analysis of dynamic growth of human embryonic stem cells: comparison of automated instrumentation and conventional culturing methods.

    abstract:BACKGROUND:Human embryonic stem cells (hESCs) are a potential source of cells for use in regenerative medicine. Automation of culturing, monitoring and analysis is crucial for fast and reliable optimization of hESC culturing methods. Continuous monitoring of living cell cultures can reveal more information and is faste...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-6-11

    authors: Narkilahti S,Rajala K,Pihlajamäki H,Suuronen R,Hovatta O,Skottman H

    更新日期:2007-04-12 00:00:00

  • An in vitro test bench reproducing coronary blood flow signals.

    abstract:BACKGROUND:It is a known fact that blood flow pattern and more specifically the pulsatile time variation of shear stress on the vascular wall play a key role in atherogenesis. The paper presents the conception, the building and the control of a new in vitro test bench that mimics the pulsatile flows behavior based on i...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-015-0065-x

    authors: Chodzyński KJ,Boudjeltia KZ,Lalmand J,Aminian A,Vanhamme L,de Sousa DR,Gremmo S,Bricteux L,Renotte C,Courbebaisse G,Coussement G

    更新日期:2015-08-07 00:00:00

  • In memorium: Herman p. Schwan [1915-2005].

    abstract::Herman P. Schwan [1915-2005] was a distinguished scientist and engineer, and a founding father of the field of biomedical engineering. A man of integrity, Schwan influenced the lives of many, including his wife and children, and his many students and colleagues. Active in science until nearly the end of his life, he w...

    journal_title:Biomedical engineering online

    pub_type: 传,历史文章,杂志文章

    doi:10.1186/1475-925X-4-21

    authors: Foster KR

    更新日期:2005-03-25 00:00:00

  • Exploiting nonlinear recurrence and fractal scaling properties for voice disorder detection.

    abstract:BACKGROUND:Voice disorders affect patients profoundly, and acoustic tools can potentially measure voice function objectively. Disordered sustained vowels exhibit wide-ranging phenomena, from nearly periodic to highly complex, aperiodic vibrations, and increased "breathiness". Modelling and surrogate data studies have s...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-6-23

    authors: Little MA,McSharry PE,Roberts SJ,Costello DA,Moroz IM

    更新日期:2007-06-26 00:00:00

  • Assessment of significance of features acquired from thyroid ultrasonograms in Hashimoto's disease.

    abstract:INTRODUCTION:This paper concerns the analysis of the features obtained from thyroid ultrasound images in left and right transverse and longitudinal sections. In the image analysis, the thyroid lobe is treated as a texture for healthy subjects and patients with Hashimoto's disease. The applied methods of analysis and im...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-11-48

    authors: Koprowski R,Zieleźnik W,Wróbel Z,Małyszek J,Stępień B,Wójcik W

    更新日期:2012-08-16 00:00:00

  • S-EMG signal compression based on domain transformation and spectral shape dynamic bit allocation.

    abstract:BACKGROUND:Surface electromyographic (S-EMG) signal processing has been emerging in the past few years due to its non-invasive assessment of muscle function and structure and because of the fast growing rate of digital technology which brings about new solutions and applications. Factors such as sampling rate, quantiza...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-13-22

    authors: Trabuco MH,Costa MV,Nascimento FA

    更新日期:2014-02-27 00:00:00

  • Real-time feature extraction of P300 component using adaptive nonlinear principal component analysis.

    abstract:BACKGROUND:The electroencephalography (EEG) signals are known to involve the firings of neurons in the brain. The P300 wave is a high potential caused by an event-related stimulus. The detection of P300s included in the measured EEG signals is widely investigated. The difficulties in detecting them are that they are mi...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-10-83

    authors: Turnip A,Hong KS,Jeong MY

    更新日期:2011-09-23 00:00:00

  • Non-viral eNOS gene delivery and transfection with stents for the treatment of restenosis.

    abstract:BACKGROUND:In this study, we have examined local non-viral gene delivery, transfection, and therapeutic efficacy of endothelial nitric oxide synthase (eNOS) encoding plasmid DNA administered using coated stents in a rabbit iliac artery restenosis model. METHODS:Lipopolyplexes (LPPs) with eNOS expressing plasmid DNA we...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-9-56

    authors: Brito LA,Chandrasekhar S,Little SR,Amiji MM

    更新日期:2010-09-27 00:00:00

  • Noninvasive measurement of cardiac stroke volume using pulse wave velocity and aortic dimensions: a simulation study.

    abstract:BACKGROUND:Concerns about the cost-effectiveness of invasive hemodynamic monitoring in critically ill patients using pulmonary artery catheters motivate a renewed search for effective noninvasive methods to measure stroke volume. This paper explores a new approach based on noninvasively measured pulse wave velocity, pu...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-13-137

    authors: Babbs CF

    更新日期:2014-09-19 00:00:00

  • Dynamic behavior of suture-anastomosed arteries and implications to vascular surgery operations.

    abstract:BACKGROUND:Routine vascular surgery operations involve stitching of disconnected human arteries with themselves or with artificial grafts (arterial anastomosis). This study aims to extend current knowledge and provide better-substantiated understanding of the mechanics of end-to-end anastomosis through the development ...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-14-1

    authors: Roussis PC,Giannakopoulos AE,Charalambous HP,Demetriou DC,Georghiou GP

    更新日期:2015-01-06 00:00:00

  • Low-dose CT reconstruction via L1 dictionary learning regularization using iteratively reweighted least-squares.

    abstract:BACKGROUND:In order to reduce the radiation dose of CT (computed tomography), compressed sensing theory has been a hot topic since it provides the possibility of a high quality recovery from the sparse sampling data. Recently, the algorithm based on DL (dictionary learning) was developed to deal with the sparse CT reco...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-016-0193-y

    authors: Zhang C,Zhang T,Li M,Peng C,Liu Z,Zheng J

    更新日期:2016-06-18 00:00:00

  • In vitro evaluation of Panax notoginseng Rg1 released from collagen/chitosan-gelatin microsphere scaffolds for angiogenesis.

    abstract:BACKGROUND:The emergence of skin substitutes provides a new approach for the treatment of wound repair and healing. The consistent and steady release of angiogenic factors is an important factor in the promotion of angiogenesis in skin substitutes, which usually lack, yet need, a vascular network. METHODS:In this stud...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-12-134

    authors: Zheng Y,Feng Z,You C,Jin Y,Hu X,Wang X,Han C

    更新日期:2013-12-31 00:00:00

  • Comparison of human uterine cervical electrical impedance measurements derived using two tetrapolar probes of different sizes.

    abstract:BACKGROUND:We sought to compare uterine cervical electrical impedance spectroscopy measurements employing two probes of different sizes, and to employ a finite element model to predict and compare the fraction of electrical current derived from subepithelial stromal tissue. METHODS:Cervical impedance was measured in 1...

    journal_title:Biomedical engineering online

    pub_type: 临床试验,杂志文章

    doi:10.1186/1475-925X-5-62

    authors: Gandhi SV,Walker DC,Brown BH,Anumba DO

    更新日期:2006-11-24 00:00:00

  • Automated identification of reference genes based on RNA-seq data.

    abstract:BACKGROUND:Gene expression analyses demand appropriate reference genes (RGs) for normalization, in order to obtain reliable assessments. Ideally, RG expression levels should remain constant in all cells, tissues or experimental conditions under study. Housekeeping genes traditionally fulfilled this requirement, but the...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-017-0356-5

    authors: Carmona R,Arroyo M,Jiménez-Quesada MJ,Seoane P,Zafra A,Larrosa R,Alché JD,Claros MG

    更新日期:2017-08-18 00:00:00

  • Performance evaluation of a motor-imagery-based EEG-Brain computer interface using a combined cue with heterogeneous training data in BCI-Naive subjects.

    abstract:BACKGROUND:The subjects in EEG-Brain computer interface (BCI) system experience difficulties when attempting to obtain the consistent performance of the actual movement by motor imagery alone. It is necessary to find the optimal conditions and stimuli combinations that affect the performance factors of the EEG-BCI syst...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-10-91

    authors: Choi D,Ryu Y,Lee Y,Lee M

    更新日期:2011-10-12 00:00:00

  • Telepointer technology in telemedicine: a review.

    abstract::Telepointer is a powerful tool in the telemedicine system that enhances the effectiveness of long-distance communication. Telepointer has been tested in telemedicine, and has potential to a big influence in improving quality of health care, especially in the rural area. A telepointer system works by sending additional...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章,评审

    doi:10.1186/1475-925X-12-21

    authors: Abdul Karim R,Zakaria NF,Zulkifley MA,Mustafa MM,Sagap I,Md Latar NH

    更新日期:2013-03-09 00:00:00

  • Effect of pressure and padding on motion artifact of textile electrodes.

    abstract:BACKGROUND:With the aging population and rising healthcare costs, wearable monitoring is gaining importance. The motion artifact affecting dry electrodes is one of the main challenges preventing the widespread use of wearable monitoring systems. In this paper we investigate the motion artifact and ways of making a text...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-12-26

    authors: Cömert A,Honkala M,Hyttinen J

    更新日期:2013-04-08 00:00:00

  • Development and mechanical testing of a short intramedullary nail for fixation of femoral rotational osteotomy in cerebral palsy patients.

    abstract:BACKGROUND:Rotational osteotomy is frequently indicated to correct excessive femoral anteversion in cerebral palsy patients. Angled blade plate is the standard fixation device used when performed in the proximal femur, but extensile exposure is required for plate accommodation. The authors developed a short locked intr...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-10-57

    authors: Pagnano RG,Okubo R,Volpon JB

    更新日期:2011-06-28 00:00:00

  • Safety assessment of near infrared light emitting diodes for diffuse optical measurements.

    abstract:BACKGROUND:Near infrared (NIR) light has been used widely to monitor important hemodynamic parameters in tissue non-invasively. Pulse oximetry, near infrared spectroscopy, and diffuse optical tomography are examples of such NIR light-based applications. These and other similar applications employ either lasers or light...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-3-9

    authors: Bozkurt A,Onaral B

    更新日期:2004-03-22 00:00:00

  • In vivo and in vitro performance of a China-made hemodialysis machine: a multi-center prospective controlled study.

    abstract:OBJECTIVE:To evaluate the in vivo and in vitro performance of a China-made dialysis machine (SWS-4000). METHODS:This was a multi-center prospective controlled study consisting of both long-term in vitro evaluations and cross-over in vivo tests in 132 patients. The China-made SWS-4000 dialysis machine was compared with...

    journal_title:Biomedical engineering online

    pub_type: 临床试验,杂志文章,多中心研究

    doi:10.1186/s12938-017-0387-y

    authors: Wang Y,Chen XM,Cai GY,Li WG,Zhang AH,Hao LR,Shi M,Wang R,Jiang HL,Luo HM,Zhang D,Sun XF

    更新日期:2017-08-02 00:00:00