Abstract:
BACKGROUND:The emergence of skin substitutes provides a new approach for the treatment of wound repair and healing. The consistent and steady release of angiogenic factors is an important factor in the promotion of angiogenesis in skin substitutes, which usually lack, yet need, a vascular network. METHODS:In this study, ginsenoside Rg1, a natural compound isolated from Panax notoginseng (PNS), was incorporated into a collagen/chitosan-gelatin microsphere (CC-GMS) scaffold. The cumulative release kinetics were evaluated, and the effects of the released Rg1 on human umbilical vein endothelial cells (HUVECs) behavior, including proliferation, migration, tube formation, cell-cycle progression, cell apoptosis, and vascular endothelial growth factor (VEGF) secretion, were investigated. Additionally, HUVECs were cultured on the CC-GMS scaffold to test its biocompatibility. Standard Rg1 and VEGF were used as positive controls. RESULTS:The results indicated that the CC-GMS scaffold had good release kinetics. The Rg1 released from the CC-GMS scaffold did not lose its activity and had a significant effect on HUVEC proliferation. Both Rg1 and VEGF promoted HUVEC migration and tube formation. Rg1 did not induce HUVEC apoptosis but instead promoted HUVEC progression into the S and G2/M phases of the cell cycle. Rg1 significantly increased VEGF secretion compared with that in the control group. HUVEC culture on the CC-GMS scaffold indicated that this scaffold has good biocompatibility and that CC-GMS scaffolds containing different concentrations of Rg1 promote HUVEC attachment in a dose- and time-dependent manner. CONCLUSIONS:Rg1 may represent a new class of angiogenic agent that can be encapsulated in CC-GMS scaffolds to exert angiogenic effects in engineered tissue.
journal_name
Biomed Eng Onlinejournal_title
Biomedical engineering onlineauthors
Zheng Y,Feng Z,You C,Jin Y,Hu X,Wang X,Han Cdoi
10.1186/1475-925X-12-134subject
Has Abstractpub_date
2013-12-31 00:00:00pages
134issn
1475-925Xpii
1475-925X-12-134journal_volume
12pub_type
杂志文章abstract:BACKGROUND:Speech production and speech phonetic features gradually improve in children by obtaining audio feedback after cochlear implantation or using hearing aids. The aim of this study was to develop and evaluate automated classification of voice disorder in children with cochlear implantation and hearing aids. ME...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/1475-925X-10-3
更新日期:2011-01-14 00:00:00
abstract:BACKGROUND:Dendritic cells are potent and specialized antigen presenting cells, which play a crucial role in initiating and amplifying both the innate and adaptive immune responses. The dendritic cell-based vaccination against cancer has been clinically achieved promising successes. But there are still many challenges ...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/1475-925X-13-2
更新日期:2014-01-10 00:00:00
abstract:BACKGROUND:In order to characterize the intracranial pressure-volume reserve capacity, the correlation coefficient (R) between the ICP wave amplitude (A) and the mean ICP level (P), the RAP index, has been used to improve the diagnostic value of ICP monitoring. Baseline pressure errors (BPEs), caused by spontaneous shi...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/1475-925X-13-99
更新日期:2014-07-23 00:00:00
abstract:BACKGROUND:Pre-operative imaging devices generate high-resolution images but intra-operative imaging devices generate low-resolution images. To use high-resolution pre-operative images during surgery, they must be deformed to reflect intra-operative geometry of brain. METHODS:We employ biomechanical models, guided by ...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/1475-925X-9-51
更新日期:2010-09-15 00:00:00
abstract:BACKGROUND:A specific problem using the public access defibrillators (PADs) arises at the railway stations. Some countries as Germany, Austria, Switzerland, Norway and Sweden are using AC railroad net power-supply system with rated 16.7 Hz frequency modulated from 15.69 Hz to 17.36 Hz. The power supply frequency contam...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/1475-925X-4-16
更新日期:2005-03-15 00:00:00
abstract:BACKGROUND:Surface roughness is the main factor determining bacterial adhesion, biofilm growth and plaque formation on the dental surfaces in vivo. Air-polishing of dental surfaces removes biofilm but can also damage the surface by increasing its roughness. The purpose of this study was to investigate the surface damag...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/1475-925X-9-59
更新日期:2010-10-12 00:00:00
abstract:BACKGROUND:Nonnegative matrix factorization (NMF) has been used in blind fluorescence unmixing for multispectral in-vivo fluorescence imaging, which decomposes a mixed source data into a set of constituent fluorescence spectra and corresponding concentrations. However, most classical NMF algorithms have ill convergence...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/s12938-015-0107-4
更新日期:2015-12-15 00:00:00
abstract::Telepointer is a powerful tool in the telemedicine system that enhances the effectiveness of long-distance communication. Telepointer has been tested in telemedicine, and has potential to a big influence in improving quality of health care, especially in the rural area. A telepointer system works by sending additional...
journal_title:Biomedical engineering online
pub_type: 杂志文章,评审
doi:10.1186/1475-925X-12-21
更新日期:2013-03-09 00:00:00
abstract:BACKGROUND:In this study, we have examined local non-viral gene delivery, transfection, and therapeutic efficacy of endothelial nitric oxide synthase (eNOS) encoding plasmid DNA administered using coated stents in a rabbit iliac artery restenosis model. METHODS:Lipopolyplexes (LPPs) with eNOS expressing plasmid DNA we...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/1475-925X-9-56
更新日期:2010-09-27 00:00:00
abstract:BACKGROUND:Robot-assisted laparoscopic surgery offers several advantages compared with open surgery and conventional minimally invasive surgery. However, one issue that needs to be resolved is a collision between the robot arm and the assistant instrument. This is mostly caused by miscommunication between the surgeon a...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/s12938-016-0189-7
更新日期:2016-05-20 00:00:00
abstract:OBJECTIVE:The purpose of this study was to show the effects of the tracheal gas insufflation (TGI) technique on gas exchange using helium-oxygen mixtures during high-frequency oscillatory ventilation (HFOV). We hypothesized that a helium-oxygen mixture delivered into the trachea using the TGI technique (0.3 L/min) woul...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/1475-925X-12-29
更新日期:2013-04-08 00:00:00
abstract:BACKGROUND:The usability of dexterous hand prostheses is still hampered by the lack of natural and effective control strategies. A decoding strategy based on the processing of descending efferent neural signals recorded using peripheral neural interfaces could be a solution to such limitation. Unfortunately, this choic...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/s12938-019-0659-9
更新日期:2019-04-08 00:00:00
abstract:BACKGROUND:Knowing the orientation of the head is important in many fields, including medicine. Many methods and measuring systems exist, but usually they use different markers or sensors attached to the subject's head for head orientation determination. In certain applications these attachments may represent a burden ...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/1475-925X-12-96
更新日期:2013-09-26 00:00:00
abstract:BACKGROUND:We sought to compare uterine cervical electrical impedance spectroscopy measurements employing two probes of different sizes, and to employ a finite element model to predict and compare the fraction of electrical current derived from subepithelial stromal tissue. METHODS:Cervical impedance was measured in 1...
journal_title:Biomedical engineering online
pub_type: 临床试验,杂志文章
doi:10.1186/1475-925X-5-62
更新日期:2006-11-24 00:00:00
abstract:BACKGROUND:Robot-based joint-testing systems (RJTS) can be used to perform unconstrained laxity tests, measuring the stiffness of a degree of freedom (DOF) of the joint at a fixed flexion angle while allowing the other DOFs unconstrained movement. Previous studies using the force-position hybrid (FPH) control method pr...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/s12938-016-0195-9
更新日期:2016-06-07 00:00:00
abstract:BACKGROUND:Magneto-acoustic tomography with current injection involves using electrical impedance imaging technology. To explore the potential applications in imaging biological tissue and enhance image quality, a new scan mode for the transducer is proposed that is based on translational and circular scanning to recor...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/s12938-016-0125-x
更新日期:2016-01-27 00:00:00
abstract:BACKGROUND:Respiratory effort belt measurement is a widely used method to monitor respiration. Signal waveforms of respiratory volume and flow may indicate pathological signs of several diseases and, thus, it would be highly desirable to predict them accurately. Calibrated effort belts are sufficiently accurate for est...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/1475-925X-12-97
更新日期:2013-09-28 00:00:00
abstract:BACKGROUND AND AIMS:People with internet addiction (IA) suffer from mental, physical, social, and occupational problems. IA includes psychological and physiological syndromes, and among the syndromes, emotion was suggested important mental and physiological expressions of IA. However, few physiologically emotional char...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/s12938-016-0201-2
更新日期:2016-07-04 00:00:00
abstract:BACKGROUND:Irrigation is considered to be a critical part of root canal treatment. However, little is known about the effect of needle movement on the irrigation process. Therefore, this study aimed to investigate the influence of the syringe and needle movement on root canal irrigation using a three-dimensional comput...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/s12938-019-0679-5
更新日期:2019-05-06 00:00:00
abstract:BACKGROUND:Areas with high frequency activity within the atrium are thought to be 'drivers' of the rhythm in patients with atrial fibrillation (AF) and ablation of these areas seems to be an effective therapy in eliminating DF gradient and restoring sinus rhythm. Clinical groups have applied the traditional FFT-based a...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/s12938-016-0143-8
更新日期:2016-03-08 00:00:00
abstract:BACKGROUND:Sleep apnea (OSA) is a common sleep disorder characterized by recurring breathing pauses during sleep caused by a blockage of the upper airway (UA). The altered UA structure or function in OSA speakers has led to hypothesize the automatic analysis of speech for OSA assessment. In this paper we critically rev...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/s12938-016-0138-5
更新日期:2016-02-20 00:00:00
abstract:BACKGROUND:Exercise has been found to either reduce or increase arterial stiffness. Land-based exercise modalities have been documented as effective physical therapies to decrease arterial stiffness. However, these land-based exercise modalities may not be suitable for overweight individuals, in terms of risks of joint...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/s12938-016-0274-y
更新日期:2016-12-28 00:00:00
abstract:BACKGROUND:Mobile health apps (mHealth apps) are increasing in popularity and utility for the management of many chronic diseases. Although the current reimbursement structure for mHealth apps is lagging behind the rapidly improving functionality, more clinicians will begin to recommend these apps as they prove their c...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/s12938-018-0611-4
更新日期:2018-12-17 00:00:00
abstract:BACKGROUND:State-of-the-art signal processing methods are known to detect information in single-trial event-related EEG data, a crucial aspect in development of real-time applications such as brain computer interfaces. This paper investigates one such novel approach, evaluating how individual classifier and feature sub...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/1475-925X-6-32
更新日期:2007-08-23 00:00:00
abstract:BACKGROUND:The electroencephalography (EEG) signals are known to involve the firings of neurons in the brain. The P300 wave is a high potential caused by an event-related stimulus. The detection of P300s included in the measured EEG signals is widely investigated. The difficulties in detecting them are that they are mi...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/1475-925X-10-83
更新日期:2011-09-23 00:00:00
abstract:BACKGROUND:Abnormal blood glucose (BG) concentrations have been associated with increased morbidity and mortality in both critically ill adults and infants. Furthermore, hypoglycaemia and glycaemic variability have both been independently linked to mortality in these patients. Continuous Glucose Monitoring (CGM) device...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/1475-925X-11-45
更新日期:2012-08-06 00:00:00
abstract:BACKGROUND:Effective fixation of fracture requires careful selection of a suitable implant to provide stability and durability. Implant with a feature of locking plate (LP) has been used widely for treating distal fractures in femur because of its favourable clinical outcome, but its potential in fixing proximal fractu...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/1475-925X-11-23
更新日期:2012-04-30 00:00:00
abstract::Advances in biomaterials and the need for patient-specific bone scaffolds require modern manufacturing approaches in addition to a design strategy. Hybrid materials such as those with functionally graded properties are highly needed in tissue replacement and repair. However, their constituents, proportions, sizes, con...
journal_title:Biomedical engineering online
pub_type: 杂志文章,评审
doi:10.1186/s12938-020-00810-2
更新日期:2020-09-03 00:00:00
abstract:BACKGROUND:Image quality assessment method of photoacoustic tomography has not been completely standardized yet. Due to the combined nature of photonic signal generation and ultrasonic signal transmission in biological tissue, neither optical nor ultrasonic traditional methods can be used without modification. An optic...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/1475-925X-11-37
更新日期:2012-07-13 00:00:00
abstract:BACKGROUND:Understanding aneurysm growth rate allows us to predict not only the current rupture risk, but also accumulated rupture risk in the future. However, determining growth rate of unruptured intracranial aneurysms often requires follow-up of patients for a long period of time so that significant growth can be ob...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/1475-925X-8-11
更新日期:2009-06-18 00:00:00