Abstract:
BACKGROUND:Phase contrast magnetic resonance imaging (PC-MRI) is used clinically for quantitative assessment of cardiovascular flow and function, as it is capable of providing directly-measured 3D velocity maps. Alternatively, vascular flow can be estimated from model-based computation fluid dynamics (CFD) calculations. CFD provides arbitrarily high resolution, but its accuracy hinges on model assumptions, while velocity fields measured with PC-MRI generally do not satisfy the equations of fluid dynamics, provide limited resolution, and suffer from partial volume effects. The purpose of this study is to develop a proof-of-concept numerical procedure for constructing a simulated flow field that is influenced by both direct PC-MRI measurements and a fluid physics model, thereby taking advantage of both the accuracy of PC-MRI and the high spatial resolution of CFD. The use of the proposed approach in regularizing 3D flow fields is evaluated. METHODS:The proposed algorithm incorporates both a Newtonian fluid physics model and a linear PC-MRI signal model. The model equations are solved numerically using a modified CFD algorithm. The numerical solution corresponds to the optimal solution of a generalized Tikhonov regularization, which provides a flow field that satisfies the flow physics equations, while being close enough to the measured PC-MRI velocity profile. The feasibility of the proposed approach is demonstrated on data from the carotid bifurcation of one healthy volunteer, and also from a pulsatile carotid flow phantom. RESULTS:The proposed solver produces flow fields that are in better agreement with direct PC-MRI measurements than CFD alone, and converges faster, while closely satisfying the fluid dynamics equations. For the implementation that provided the best results, the signal-to-error ratio (with respect to the PC-MRI measurements) in the phantom experiment was 6.56 dB higher than that of conventional CFD; in the in vivo experiment, it was 2.15 dB higher. CONCLUSIONS:The proposed approach allows partial or complete measurements to be incorporated into a modified CFD solver, for improving the accuracy of the resulting flow fields estimates. This can be used for reducing scan time, increasing the spatial resolution, and/or denoising the PC-MRI measurements.
journal_name
Biomed Eng Onlinejournal_title
Biomedical engineering onlineauthors
Rispoli VC,Nielsen JF,Nayak KS,Carvalho JLdoi
10.1186/s12938-015-0104-7subject
Has Abstractpub_date
2015-11-26 00:00:00pages
110issn
1475-925Xpii
10.1186/s12938-015-0104-7journal_volume
14pub_type
杂志文章abstract:BACKGROUND:Neural stimulation is an important method used to activate or inhibit action potentials of the neuronal anatomical targets found in the brain, central nerve and peripheral nerve. The neural stimulator system produces biphasic pulses that deliver balanced charge into tissue from single or multichannel electro...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/s12938-017-0385-0
更新日期:2017-08-14 00:00:00
abstract:BACKGROUND:The lumbar range of motion has traditionally been used to assess disability in patients with low back disorders. Controversy exists about how movement ranges in static positions or in a single straight plane is related to the functional status of the patients. The trunk circumduction, as the result of neurom...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/1475-925X-12-4
更新日期:2013-01-11 00:00:00
abstract:BACKGROUND:Mitral valve failure can require repair or replacement. Replacement bioprosthetic valves are treated with glutaraldehyde prior to implantation. The aim of this study was to determine the changes in mechanical properties following glutaraldehyde fixation of mitral valve chordae. METHODS:To investigate the im...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/s12938-018-0524-2
更新日期:2018-07-13 00:00:00
abstract:BACKGROUND:The emergence and development of robot assistant interventional vascular surgery technologies have benefited many patients with cardiovascular or cerebrovascular diseases. Due to the absence of effective training measures, these new advanced technologies have not been fully utilized and only few experienced ...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/s12938-016-0148-3
更新日期:2016-04-06 00:00:00
abstract::The control of robotic prostheses based on pattern recognition algorithms is a widely studied subject that has shown promising results in acute experiments. The long-term implementation of this technology, however, has not yet been achieved due to practical issues that can be mainly attributed to the use of surface el...
journal_title:Biomedical engineering online
pub_type: 杂志文章,评审
doi:10.1186/1475-925X-11-33
更新日期:2012-06-20 00:00:00
abstract::The Editors-in-Chief have retracted this article [1] because, after publication, concerns were raised regarding the study design and statistical analysis. Post-publication review has confirmed firstly that within-group changes were highlighted rather than between-group differences as appropriate for a randomized trial...
journal_title:Biomedical engineering online
pub_type: 杂志文章,撤回出版物
doi:10.1186/s12938-020-0749-8
更新日期:2020-01-24 00:00:00
abstract:BACKGROUND:Effective fixation of fracture requires careful selection of a suitable implant to provide stability and durability. Implant with a feature of locking plate (LP) has been used widely for treating distal fractures in femur because of its favourable clinical outcome, but its potential in fixing proximal fractu...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/1475-925X-11-23
更新日期:2012-04-30 00:00:00
abstract:BACKGROUND:Biomechanical and clinical parameters contribute very closely to functional evaluations of the knee joint. To better understand knee osteoarthritis joint function, the association between a set of knee biomechanical data and a set of clinical parameters of an osteoarthritis population (OA) is investigated in...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/s12938-019-0676-8
更新日期:2019-05-15 00:00:00
abstract:BACKGROUND:Shape of the dental root canal is highly patient specific. Automated identification methods of the medial line of dental root canals and the reproduction of their 3D shape can be beneficial for planning endodontic interventions as severely curved root canals or multi-rooted teeth may pose treatment challenge...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/1475-925X-11-81
更新日期:2012-10-29 00:00:00
abstract:BACKGROUND:In this paper we present a novel scene retargeting technique to reduce the visual scene while maintaining the size of the key features. The algorithm is scalable to implementation onto portable devices, and thus, has potential for augmented reality systems to provide visual support for those with tunnel visi...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/1475-925X-9-52
更新日期:2010-09-16 00:00:00
abstract:BACKGROUND:A valveless pump generates a unidirectional net flow of fluid around a closed loop of soft viscoelastic tubing that is rhythmically compressed at one point. The tubing must have at least two sections with two different stiffnesses. When a short segment of the tube is squeezed asymmetrically at certain freque...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/1475-925X-9-42
更新日期:2010-08-31 00:00:00
abstract:BACKGROUND:The anterior cruciate ligament (ACL) plays an important role in stabilizing translation and rotation of the tibia relative to the femur. ACL injury alters knee kinematics and usually links to the alternation of gait patterns. The aim of this study is to develop a new method to distinguish between gait patter...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/s12938-018-0594-1
更新日期:2018-11-01 00:00:00
abstract:BACKGROUND:In literature, the effect of the inflow boundary condition was investigated by examining the impact of the waveform and the shape of the spatial profile of the inlet velocity on the cardiac hemodynamics. However, not much work has been reported on comparing the effect of the different combinations of the inl...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/1475-925X-14-S1-S6
更新日期:2015-01-01 00:00:00
abstract:BACKGROUND:STAR is a model-based, personalised, risk-based dosing approach for glycaemic control (GC) in critically ill patients. STAR provides safe, effective control to nearly all patients, using 1-3 hourly measurement and intervention intervals. However, the average 11-12 measurements per day required can be a clini...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/s12938-020-00771-6
更新日期:2020-04-29 00:00:00
abstract:BACKGROUND:Laser Interstitial ThermoTherapy (LITT) is a well established surgical method. The use of LITT is so far limited to homogeneous tissues, e.g. the liver. One of the reasons is the limited capability of existing treatment planning models to calculate accurately the damage zone. The treatment planning in inhomo...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/1475-925X-4-2
更新日期:2005-01-04 00:00:00
abstract:BACKGROUND:The biomechanical simulation of the human respiratory system is expected to be a useful tool for the diagnosis and treatment of respiratory diseases. Because the deformation of the thorax significantly influences airflow in the lungs, we focused on simulating the thorax deformation by introducing contraction...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/s12938-016-0132-y
更新日期:2016-02-06 00:00:00
abstract:BACKGROUND:In a typical electrophysiological experiment, especially one that includes studying animal behavior, the data collected normally contain spikes, local field potentials, behavioral responses and other associated data. In order to obtain informative results, the data must be analyzed simultaneously with the ex...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/s12938-017-0419-7
更新日期:2017-11-13 00:00:00
abstract:BACKGROUND:In cochlear implants (CI) measuring the electrically evoked compound action potential (ECAP) has become an important tool for verifying the electrode-nerve interface as well as establishing a basis for a map to program the speech processor. In a standard clinical setup recordings are averaged over 25-100 rep...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/s12938-018-0588-z
更新日期:2018-10-19 00:00:00
abstract:BACKGROUND:One of the recommended treatments for disorders associated with the lower extremity venous insufficiency is the application of external mechanical compression. Compression stockings and elastic bandages are widely used for the purpose of compression therapy and are usually designed to exert a specified value...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/s12938-015-0088-3
更新日期:2015-11-05 00:00:00
abstract:BACKGROUND:The QRS complex is the most noticeable feature in the electrocardiogram (ECG) signal, therefore, its detection is critical for ECG signal analysis. The existing detection methods largely depend on hand-crafted manual features and parameters, which may introduce significant computational complexity, especiall...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/s12938-018-0441-4
更新日期:2018-01-29 00:00:00
abstract:BACKGROUND:State-of-the-art signal processing methods are known to detect information in single-trial event-related EEG data, a crucial aspect in development of real-time applications such as brain computer interfaces. This paper investigates one such novel approach, evaluating how individual classifier and feature sub...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/1475-925X-6-32
更新日期:2007-08-23 00:00:00
abstract:OBJECTIVE:To evaluate the in vivo and in vitro performance of a China-made dialysis machine (SWS-4000). METHODS:This was a multi-center prospective controlled study consisting of both long-term in vitro evaluations and cross-over in vivo tests in 132 patients. The China-made SWS-4000 dialysis machine was compared with...
journal_title:Biomedical engineering online
pub_type: 临床试验,杂志文章,多中心研究
doi:10.1186/s12938-017-0387-y
更新日期:2017-08-02 00:00:00
abstract:BACKGROUND:We and others have previously demonstrated that adipose-derived stem cells (ASCs) transplantation improve cardiac dysfunction post-myocardium infarction (MI) under hemodynamic stress in rats. The beneficial effects appear to be associated with pleiotropic factors due to a complex interplay between the transp...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/1475-925X-13-54
更新日期:2014-05-01 00:00:00
abstract:BACKGROUND:Non-contact tonometers based on the method using air puff and Scheimpflug's fast camera are one of the latest devices allowing the measurement of intraocular pressure and additional biomechanical parameters of the cornea. Biomechanical features significantly affect changes in intraocular pressure values, as ...
journal_title:Biomedical engineering online
pub_type: 杂志文章,评审
doi:10.1186/s12938-019-0636-3
更新日期:2019-02-13 00:00:00
abstract:BACKGROUND:Dendritic cells are potent and specialized antigen presenting cells, which play a crucial role in initiating and amplifying both the innate and adaptive immune responses. The dendritic cell-based vaccination against cancer has been clinically achieved promising successes. But there are still many challenges ...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/1475-925X-13-2
更新日期:2014-01-10 00:00:00
abstract:BACKGROUND:Current devices for measuring muscle contraction in vivo have limited accuracy in establishing and re-establishing the optimum muscle length. They are variable in the reproducibility to determine the muscle contraction at this length, and often do not maintain precise conditions during the examination. Conse...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/1475-925X-6-1
更新日期:2007-01-02 00:00:00
abstract::A large number of incommensurable metrics are currently used to report the performance of brain-computer interfaces (BCI) used for augmentative and alterative communication (AAC). The lack of standard metrics precludes the comparison of different BCI-based AAC systems, hindering rapid growth and development of this te...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/1475-925X-12-43
更新日期:2013-05-16 00:00:00
abstract:BACKGROUND:Classification of breast ultrasound (BUS) images is an important step in the computer-aided diagnosis (CAD) system for breast cancer. In this paper, a novel phase-based texture descriptor is proposed for efficient and robust classifiers to discriminate benign and malignant tumors in BUS images. METHOD:The p...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/s12938-015-0022-8
更新日期:2015-03-24 00:00:00
abstract:BACKGROUND:Electrical impedance tomography (EIT) has been used for functional lung imaging of regional air distributions during mechanical ventilation in intensive care units (ICU). From numerous clinical and animal studies focusing on specific lung functions, a consensus about how to use the EIT technique has been for...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/s12938-019-0701-y
更新日期:2019-07-25 00:00:00
abstract:BACKGROUND:Falls can cause trauma, disability and death among older people. Ambulatory accelerometer devices are currently capable of detecting falls in a controlled environment. However, research suggests that most current approaches can tend to have insufficient sensitivity and specificity in non-laboratory environme...
journal_title:Biomedical engineering online
pub_type: 杂志文章
doi:10.1186/1475-925X-11-9
更新日期:2012-02-16 00:00:00