3-Dimensional printing in rehabilitation: feasibility of printing an upper extremity gross motor function assessment tool.

Abstract:

BACKGROUND:Use of standardized and scientifically sound outcome measures is encouraged in clinical practice and research. With the development of newer rehabilitation therapies, we need technology-supported upper extremity outcome measures that are easily accessible, reliable and valid. 3-Dimensional printing (3D-printing) has recently seen a meteoric rise in interest within medicine including the field of Physical Medicine and Rehabilitation. The primary objective of this study was to evaluate the feasibility of designing and constructing a 3D printed version of the Toronto Rehabilitation Institute-Hand Function Test (TRI-HFT). The TRI-HFT is an upper extremity gross motor function assessment tool that measures function at the intersection of the International Classification of Function's body structure and function, and activity domain. The secondary objective was to assess the preliminary psychometrics of this test in individuals with stroke. RESULTS:3D design files were created using the measurements of the original TRI-HFT objects. The 3D printed objects were then compared to the original test objects to ensure that the original dimensions were preserved. All objects were successfully printed except the sponge and paper which required some modification. The error margin for weight of the objects was within 10% of the original TRI-HFT for the rest of the objects. Nine participants underwent the following assessments: the Chedoke Arm and Hand Activity Inventory (CAHAI), Fugl Meyer Assessment-Hand (FMA-Hand), Chedoke McMaster stages of recovery of the arm (CMSA-Arm) and Chedoke McMaster stages of recovery of the hand (CMSA-Hand) and the 3D TRI-HFT for assessment of psychometric properties of the test. The video recorded assessment of the 3D TRI-HFT was used for reliability testing. Construct validity was assessed by comparing the scores on 3D TRI-HFT with the scores on CAHAI, CMSA-Arm, CMSA-Hand and FMA-Hand. The 3D TRI-HFT had high inter-rater reliability (Intra-Class Correlation Co-efficient (ICC) of 0.99; P < 0.000), high intra-rater reliability (ICC of 0.99; P < 0.000) and moderate-to-strong correlation with the CMSA-Arm, CMSA-Hand and FMA-Hand scores. CONCLUSIONS:The TRI-HFT could be successfully 3D printed and initial testing indicates that the test is a reliable and valid measure of upper extremity motor function in individuals with stroke.

journal_name

Biomed Eng Online

authors

Kapadia N,Myers M,Musselman K,Wang RH,Yurkewich A,Popovic MR

doi

10.1186/s12938-020-00839-3

subject

Has Abstract

pub_date

2021-01-05 00:00:00

pages

2

issue

1

issn

1475-925X

pii

10.1186/s12938-020-00839-3

journal_volume

20

pub_type

杂志文章
  • Influence of head models on EEG simulations and inverse source localizations.

    abstract:BACKGROUND:The structure of the anatomical surfaces, e.g., CSF and gray and white matter, could severely influence the flow of volume currents in a head model. This, in turn, will also influence the scalp potentials and the inverse source localizations. This was examined in detail with four different human head models....

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-5-10

    authors: Ramon C,Schimpf PH,Haueisen J

    更新日期:2006-02-08 00:00:00

  • Characterization of the head-to-trunk orientation with handheld optical 3D apparatus based on the fringe projection technique.

    abstract:BACKGROUND:Knowing the orientation of the head is important in many fields, including medicine. Many methods and measuring systems exist, but usually they use different markers or sensors attached to the subject's head for head orientation determination. In certain applications these attachments may represent a burden ...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-12-96

    authors: Pavlovčič U,Diaci J,Možina J,Jezeršek M

    更新日期:2013-09-26 00:00:00

  • Telepointer technology in telemedicine: a review.

    abstract::Telepointer is a powerful tool in the telemedicine system that enhances the effectiveness of long-distance communication. Telepointer has been tested in telemedicine, and has potential to a big influence in improving quality of health care, especially in the rural area. A telepointer system works by sending additional...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章,评审

    doi:10.1186/1475-925X-12-21

    authors: Abdul Karim R,Zakaria NF,Zulkifley MA,Mustafa MM,Sagap I,Md Latar NH

    更新日期:2013-03-09 00:00:00

  • Developing functional workspace for the movement of trunk circumduction in healthy young subjects: a reliability study.

    abstract:BACKGROUND:The lumbar range of motion has traditionally been used to assess disability in patients with low back disorders. Controversy exists about how movement ranges in static positions or in a single straight plane is related to the functional status of the patients. The trunk circumduction, as the result of neurom...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-12-4

    authors: Cheng SC,Hsu CH,Ting YT,Kuo LC,Lin RM,Su FC

    更新日期:2013-01-11 00:00:00

  • Evolutionary optimization of classifiers and features for single-trial EEG discrimination.

    abstract:BACKGROUND:State-of-the-art signal processing methods are known to detect information in single-trial event-related EEG data, a crucial aspect in development of real-time applications such as brain computer interfaces. This paper investigates one such novel approach, evaluating how individual classifier and feature sub...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-6-32

    authors: Aberg MC,Wessberg J

    更新日期:2007-08-23 00:00:00

  • Computational fluid dynamics simulations of blood flow regularized by 3D phase contrast MRI.

    abstract:BACKGROUND:Phase contrast magnetic resonance imaging (PC-MRI) is used clinically for quantitative assessment of cardiovascular flow and function, as it is capable of providing directly-measured 3D velocity maps. Alternatively, vascular flow can be estimated from model-based computation fluid dynamics (CFD) calculations...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-015-0104-7

    authors: Rispoli VC,Nielsen JF,Nayak KS,Carvalho JL

    更新日期:2015-11-26 00:00:00

  • Two-stage CNNs for computerized BI-RADS categorization in breast ultrasound images.

    abstract:BACKGROUND:Quantizing the Breast Imaging Reporting and Data System (BI-RADS) criteria into different categories with the single ultrasound modality has always been a challenge. To achieve this, we proposed a two-stage grading system to automatically evaluate breast tumors from ultrasound images into five categories bas...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-019-0626-5

    authors: Huang Y,Han L,Dou H,Luo H,Yuan Z,Liu Q,Zhang J,Yin G

    更新日期:2019-01-24 00:00:00

  • In vitro evaluation of Panax notoginseng Rg1 released from collagen/chitosan-gelatin microsphere scaffolds for angiogenesis.

    abstract:BACKGROUND:The emergence of skin substitutes provides a new approach for the treatment of wound repair and healing. The consistent and steady release of angiogenic factors is an important factor in the promotion of angiogenesis in skin substitutes, which usually lack, yet need, a vascular network. METHODS:In this stud...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-12-134

    authors: Zheng Y,Feng Z,You C,Jin Y,Hu X,Wang X,Han C

    更新日期:2013-12-31 00:00:00

  • A wavelet-based ECG delineation algorithm for 32-bit integer online processing.

    abstract:BACKGROUND:Since the first well-known electrocardiogram (ECG) delineator based on Wavelet Transform (WT) presented by Li et al. in 1995, a significant research effort has been devoted to the exploitation of this promising method. Its ability to reliably delineate the major waveform components (mono- or bi-phasic P wave...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-10-23

    authors: Di Marco LY,Chiari L

    更新日期:2011-04-03 00:00:00

  • Blood pressure waveform contour analysis for assessing peripheral resistance changes in sepsis.

    abstract:BACKGROUND:This paper proposes a methodology for helping bridge the gap between the complex waveform information frequently available in an intensive care unit and the simple, lumped values favoured for rapid clinical diagnosis and management. This methodology employs a simple waveform contour analysis approach to comp...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-018-0603-4

    authors: Davidson S,Pretty C,Balmer J,Desaive T,Chase JG

    更新日期:2018-11-20 00:00:00

  • Three types of dermal grafts in rats: the importance of mechanical property and structural design.

    abstract:BACKGROUND:To determine how the mechanical property and micro structure affect tissue regeneration and angiogenesis, three types of scaffolds were studied. Acellular dermal matrices (ADM), produced from human skin by removing the epidermis and cells, has been widely used in wound healing because of its high mechanical ...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-12-125

    authors: You C,Wang X,Zheng Y,Han C

    更新日期:2013-12-04 00:00:00

  • In vivo and in vitro performance of a China-made hemodialysis machine: a multi-center prospective controlled study.

    abstract:OBJECTIVE:To evaluate the in vivo and in vitro performance of a China-made dialysis machine (SWS-4000). METHODS:This was a multi-center prospective controlled study consisting of both long-term in vitro evaluations and cross-over in vivo tests in 132 patients. The China-made SWS-4000 dialysis machine was compared with...

    journal_title:Biomedical engineering online

    pub_type: 临床试验,杂志文章,多中心研究

    doi:10.1186/s12938-017-0387-y

    authors: Wang Y,Chen XM,Cai GY,Li WG,Zhang AH,Hao LR,Shi M,Wang R,Jiang HL,Luo HM,Zhang D,Sun XF

    更新日期:2017-08-02 00:00:00

  • Determination of detection depth of optical probe in pedicle screw measurement device.

    abstract:BACKGROUND:There is a high probability of accidental perforation of the vertebral pedicle wall in pedicle screw insertion surgery. A pedicle screw (PS) measurement device with an optical probe has been reported to send out a warning signal before the PS tip breaking the vertebral pedicle wall. METHODS:In this study, w...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-13-148

    authors: Li W,Liu Y,Qian Z

    更新日期:2014-11-01 00:00:00

  • Collaborative and secure transmission of medical data applied to mobile healthcare.

    abstract:PURPOSE:We propose a collaborative and secure transmission scheme in order to safely and efficiently transmit medical data and provide telemedicine services, lighten the load on wireless access networks, and improve the quality of medical treatment such as surgery. METHODS:First, the transmission technology based on o...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-019-0674-x

    authors: Chen W,Chen Z,Cui F

    更新日期:2019-05-20 00:00:00

  • In vivo myograph measurement of muscle contraction at optimal length.

    abstract:BACKGROUND:Current devices for measuring muscle contraction in vivo have limited accuracy in establishing and re-establishing the optimum muscle length. They are variable in the reproducibility to determine the muscle contraction at this length, and often do not maintain precise conditions during the examination. Conse...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-6-1

    authors: Rahe-Meyer N,Weilbach C,Karst M,Pawlak M,Ahmed A,Piepenbrock S,Winterhalter M

    更新日期:2007-01-02 00:00:00

  • Investigations of the functional states of dendritic cells under different conditioned microenvironments by Fourier transformed infrared spectroscopy.

    abstract:BACKGROUND:Dendritic cells are potent and specialized antigen presenting cells, which play a crucial role in initiating and amplifying both the innate and adaptive immune responses. The dendritic cell-based vaccination against cancer has been clinically achieved promising successes. But there are still many challenges ...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-13-2

    authors: Dong R,Long J,Xu X,Zhang C,Wen Z,Li L,Yao W,Zeng Z

    更新日期:2014-01-10 00:00:00

  • Influence of the measurement method of features in ultrasound images of the thyroid in the diagnosis of Hashimoto's disease.

    abstract:INTRODUCTION:This paper shows the influence of a measurement method of features in the diagnosis of Hashimoto's disease. Sensitivity of the algorithm to changes in the parameters of the ROI, namely shift, resizing and rotation, has been presented. The obtained results were also compared to the methods known from the li...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-11-91

    authors: Koprowski R,Korzyńska A,Wróbel Z,Zieleźnik W,Witkowska A,Małyszek J,Wójcik W

    更新日期:2012-11-28 00:00:00

  • Atomic force microscopy in vitro study of surface roughness and fractal character of a dental restoration composite after air-polishing.

    abstract:BACKGROUND:Surface roughness is the main factor determining bacterial adhesion, biofilm growth and plaque formation on the dental surfaces in vivo. Air-polishing of dental surfaces removes biofilm but can also damage the surface by increasing its roughness. The purpose of this study was to investigate the surface damag...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-9-59

    authors: Salerno M,Giacomelli L,Derchi G,Patra N,Diaspro A

    更新日期:2010-10-12 00:00:00

  • 16-Channel biphasic current-mode programmable charge balanced neural stimulation.

    abstract:BACKGROUND:Neural stimulation is an important method used to activate or inhibit action potentials of the neuronal anatomical targets found in the brain, central nerve and peripheral nerve. The neural stimulator system produces biphasic pulses that deliver balanced charge into tissue from single or multichannel electro...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-017-0385-0

    authors: Li X,Zhong S,Morizio J

    更新日期:2017-08-14 00:00:00

  • Review of cognitive behavioural therapy mobile apps using a reference architecture embedded in the patient-provider relationship.

    abstract:BACKGROUND:Mobile health apps (mHealth apps) are increasing in popularity and utility for the management of many chronic diseases. Although the current reimbursement structure for mHealth apps is lagging behind the rapidly improving functionality, more clinicians will begin to recommend these apps as they prove their c...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-018-0611-4

    authors: Lan A,Lee A,Munroe K,McRae C,Kaleis L,Keshavjee K,Guergachi A

    更新日期:2018-12-17 00:00:00

  • Hemodynamic effects of perfusion level of peripheral ECMO on cardiovascular system.

    abstract:BACKGROUND:Peripheral ECMO is an effective cardiopulmonary support in clinical. The perfusion level could directly influence the performances and complications. However, there are few studies on the effects of the perfusion level on hemodynamics of peripheral ECMO. METHODS:The geometric model of cardiovascular system ...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-018-0493-5

    authors: Gu K,Zhang Z,Gao B,Chang Y,Wan F

    更新日期:2018-05-09 00:00:00

  • Simulating the swelling and deformation behaviour in soft tissues using a convective thermal analogy.

    abstract:BACKGROUND:It is generally accepted that cartilage adaptation and degeneration are mechanically mediated. Investigating the swelling behaviour of cartilage is important because the stress and strain state of cartilage is associated with the swelling and deformation behaviour. It is well accepted that the swelling of so...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925x-1-8

    authors: Wu JZ,Herzog W

    更新日期:2002-12-19 00:00:00

  • Effect of pressure and padding on motion artifact of textile electrodes.

    abstract:BACKGROUND:With the aging population and rising healthcare costs, wearable monitoring is gaining importance. The motion artifact affecting dry electrodes is one of the main challenges preventing the widespread use of wearable monitoring systems. In this paper we investigate the motion artifact and ways of making a text...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-12-26

    authors: Cömert A,Honkala M,Hyttinen J

    更新日期:2013-04-08 00:00:00

  • Effect of gamma radiation and accelerated aging on the mechanical and thermal behavior of HDPE/HA nano-composites for bone tissue regeneration.

    abstract:BACKGROUND:The replacement of hard tissues demands biocompatible and sometimes bioactive materials with properties similar to those of bone. Nano-composites made of biocompatible polymers and bioactive inorganic nano particles such as HDPE/HA have attracted attention as permanent bone substitutes due to their excellent...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-12-95

    authors: Alothman OY,Almajhdi FN,Fouad H

    更新日期:2013-09-24 00:00:00

  • On the design of a DEA-based device to pot entially assist lower leg disorders: an analytical and FEM investigation accounting for nonlinearities of the leg and device deformations.

    abstract:BACKGROUND:One of the recommended treatments for disorders associated with the lower extremity venous insufficiency is the application of external mechanical compression. Compression stockings and elastic bandages are widely used for the purpose of compression therapy and are usually designed to exert a specified value...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-015-0088-3

    authors: Pourazadi S,Ahmadi S,Menon C

    更新日期:2015-11-05 00:00:00

  • A perceptual map for gait symmetry quantification and pathology detection.

    abstract:BACKGROUND:The gait movement is an essential process of the human activity and the result of collaborative interactions between the neurological, articular and musculoskeletal systems, working efficiently together. This explains why gait analysis is important and increasingly used nowadays for the diagnosis of many dif...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-015-0097-2

    authors: Moevus A,Mignotte M,de Guise JA,Meunier J

    更新日期:2015-10-29 00:00:00

  • Influence of model boundary conditions on blood flow patterns in a patient specific stenotic right coronary artery.

    abstract:BACKGROUND:In literature, the effect of the inflow boundary condition was investigated by examining the impact of the waveform and the shape of the spatial profile of the inlet velocity on the cardiac hemodynamics. However, not much work has been reported on comparing the effect of the different combinations of the inl...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-14-S1-S6

    authors: Liu B,Zheng J,Bach R,Tang D

    更新日期:2015-01-01 00:00:00

  • Unsupervised machine-learning method for improving the performance of ambulatory fall-detection systems.

    abstract:BACKGROUND:Falls can cause trauma, disability and death among older people. Ambulatory accelerometer devices are currently capable of detecting falls in a controlled environment. However, research suggests that most current approaches can tend to have insufficient sensitivity and specificity in non-laboratory environme...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-11-9

    authors: Yuwono M,Moulton BD,Su SW,Celler BG,Nguyen HT

    更新日期:2012-02-16 00:00:00

  • Possibility of reconstruction of dental plaster cast from 3D digital study models.

    abstract:OBJECTIVES:To compare traditional plaster casts, digital models and 3D printed copies of dental plaster casts based on various criteria. To determine whether 3D printed copies obtained using open source system RepRap can replace traditional plaster casts in dental practice. To compare and contrast the qualities of two ...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-12-49

    authors: Kasparova M,Grafova L,Dvorak P,Dostalova T,Prochazka A,Eliasova H,Prusa J,Kakawand S

    更新日期:2013-05-31 00:00:00

  • Wound healing of human embryonic stem cell-derived retinal pigment epithelial cells is affected by maturation stage.

    abstract:BACKGROUND:Wound healing of retinal pigment epithelium (RPE) is a complex process that may take place in common age-related macular degeneration eye disease. The purpose of this study was to evaluate whether wounding and wound healing has an effect on Ca2+ dynamics in human embryonic stem cell (hESC)-RPEs cultured diff...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-018-0535-z

    authors: Abu Khamidakh AE,Rodriguez-Martinez A,Kaarniranta K,Kallioniemi A,Skottman H,Hyttinen J,Juuti-Uusitalo K

    更新日期:2018-07-31 00:00:00