Wound healing of human embryonic stem cell-derived retinal pigment epithelial cells is affected by maturation stage.

Abstract:

BACKGROUND:Wound healing of retinal pigment epithelium (RPE) is a complex process that may take place in common age-related macular degeneration eye disease. The purpose of this study was to evaluate whether wounding and wound healing has an effect on Ca2+ dynamics in human embryonic stem cell (hESC)-RPEs cultured different periods of time. METHODS:The 9-day-cultured or 28-day-cultured hESC-RPEs from two different cell lines were wounded and the dynamics of spontaneous and mechanically induced intracellular Ca2+ activity was measured with live-cell Ca2+ imaging either immediately or 7 days after wounding. The healing time and speed were analyzed with time-lapse bright field microscopy. The Ca2+ activity and healing speed were analysed with image analysis. In addition the extracellular matrix deposition was assessed with confocal microscopy. RESULTS:The Ca2+ dynamics in hESC-RPE monolayers differed depending on the culture time: 9-day-cultured cells had higher number of cells with spontaneous Ca2+ activity close to freshly wounded edge compared to control areas, whereas in 28-day-cultured cells there was no difference in wounded and control areas. The 28-day-cultured, wounded and 7-day-healed hESC-RPEs produced wide-spreading intercellular Ca2+ waves upon mechanical stimulation, while in controls propagation was restricted. Most importantly, both wave spreading and spontaneous Ca2+ activity of cells within the healed area, as well as the cell morphology of 28-day-cultured, wounded and thereafter 7-day-healed areas resembled the 9-day-cultured hESC-RPEs. CONCLUSIONS:This acquired knowledge about Ca2+ dynamics of wounded hESC-RPE monolayers is important for understanding the dynamics of RPE wound healing, and could offer a reliable functionality test for RPE cells. The data presented in here suggests that assessment of Ca2+ dynamics analysed with image analysis could be used as a reliable non-invasive functionality test for RPE cells.

journal_name

Biomed Eng Online

authors

Abu Khamidakh AE,Rodriguez-Martinez A,Kaarniranta K,Kallioniemi A,Skottman H,Hyttinen J,Juuti-Uusitalo K

doi

10.1186/s12938-018-0535-z

subject

Has Abstract

pub_date

2018-07-31 00:00:00

pages

102

issue

1

issn

1475-925X

pii

10.1186/s12938-018-0535-z

journal_volume

17

pub_type

杂志文章
  • Public access defibrillation: suppression of 16.7 Hz interference generated by the power supply of the railway systems.

    abstract:BACKGROUND:A specific problem using the public access defibrillators (PADs) arises at the railway stations. Some countries as Germany, Austria, Switzerland, Norway and Sweden are using AC railroad net power-supply system with rated 16.7 Hz frequency modulated from 15.69 Hz to 17.36 Hz. The power supply frequency contam...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-4-16

    authors: Christov II,Iliev GL

    更新日期:2005-03-15 00:00:00

  • Data-guide for brain deformation in surgery: comparison of linear and nonlinear models.

    abstract:BACKGROUND:Pre-operative imaging devices generate high-resolution images but intra-operative imaging devices generate low-resolution images. To use high-resolution pre-operative images during surgery, they must be deformed to reflect intra-operative geometry of brain. METHODS:We employ biomechanical models, guided by ...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-9-51

    authors: Hamidian H,Soltanian-Zadeh H,Faraji-Dana R,Gity M

    更新日期:2010-09-15 00:00:00

  • The effect of inlet and outlet boundary conditions in image-based CFD modeling of aortic flow.

    abstract:BACKGROUND:Computational modeling of cardiovascular flow is a growing and useful field, but such simulations usually require the researcher to guess the flow's inlet and outlet conditions since they are difficult and expensive to measure. It is critical to determine the amount of uncertainty introduced by these assumpt...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-018-0497-1

    authors: Madhavan S,Kemmerling EMC

    更新日期:2018-05-30 00:00:00

  • Hemodynamic numerical simulations of the disturbance due to intracoronary flow measurements by a Doppler guide wire.

    abstract:BACKGROUND:Since hemodynamics plays a key role in the development and evolution of cardiovascular pathologies, physician's decision must be based on proper monitoring of relevant physiological flow quantities. METHODS:A numerical analysis of the error introduced by an intravascular Doppler guide wire on the peak veloc...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-016-0234-6

    authors: Chodzyński KJ,Gremmo S,Eker OF,Lalmand J,Aminian A,de Sousa DR,Boudjeltia KZ,Coussement G

    更新日期:2016-10-10 00:00:00

  • 3-Dimensional printing in rehabilitation: feasibility of printing an upper extremity gross motor function assessment tool.

    abstract:BACKGROUND:Use of standardized and scientifically sound outcome measures is encouraged in clinical practice and research. With the development of newer rehabilitation therapies, we need technology-supported upper extremity outcome measures that are easily accessible, reliable and valid. 3-Dimensional printing (3D-print...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-020-00839-3

    authors: Kapadia N,Myers M,Musselman K,Wang RH,Yurkewich A,Popovic MR

    更新日期:2021-01-05 00:00:00

  • Biomechanical investigation of dynamic hip screw and wire fixation on an unstable intertrochanteric fracture.

    abstract:BACKGROUND:Although use of a dynamic hip screw (DHS) for stable intertrochanteric hip fracture fixation has been successfully applied in fracture healing for more than 20 years, DHS fixation on unstable intertrochanteric fractures still has a high failure rate, especially in patients with osteoporosis. Although the wir...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-019-0663-0

    authors: Wu HF,Chang CH,Wang GJ,Lai KA,Chen CH

    更新日期:2019-04-24 00:00:00

  • Artery buckling affects the mechanical stress in atherosclerotic plaques.

    abstract:BACKGROUND:Tortuous arteries are often seen in patients with hypertension and atherosclerosis. While the mechanical stress in atherosclerotic plaque under lumen pressure has been studied extensively, the mechanical stability of atherosclerotic arteries and subsequent effect on the plaque stress remain unknown. To this ...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-14-S1-S4

    authors: Sanyal A,Han HC

    更新日期:2015-01-01 00:00:00

  • Investigation of red blood cell mechanical properties using AFM indentation and coarse-grained particle method.

    abstract:BACKGROUND:Red blood cells (RBCs) deform significantly and repeatedly when passing through narrow capillaries and delivering dioxygen throughout the body. Deformability of RBCs is a key characteristic, largely governed by the mechanical properties of the cell membrane. This study investigated RBC mechanical properties ...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-017-0429-5

    authors: Barns S,Balanant MA,Sauret E,Flower R,Saha S,Gu Y

    更新日期:2017-12-19 00:00:00

  • A wavelet-based ECG delineation algorithm for 32-bit integer online processing.

    abstract:BACKGROUND:Since the first well-known electrocardiogram (ECG) delineator based on Wavelet Transform (WT) presented by Li et al. in 1995, a significant research effort has been devoted to the exploitation of this promising method. Its ability to reliably delineate the major waveform components (mono- or bi-phasic P wave...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-10-23

    authors: Di Marco LY,Chiari L

    更新日期:2011-04-03 00:00:00

  • Evaluation of flow changes after telescopic stenting of a giant fusiform aneurysm of the vertebrobasilar junction.

    abstract:BACKGROUND:The use of flow-diverters for non-saccular cerebral posterior circulation aneurysms requires complex deployment techniques and is associated with high mortality and morbidity. Therefore, further studies are required to clarify the effect of stenting on post-treatment hemodynamics in such aneurysms. In this s...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-019-0699-1

    authors: Sindeev S,Kirschke JS,Prothmann S,Frolov S,Liepsch D,Berg P,Zimmer C,Friedrich B

    更新日期:2019-07-24 00:00:00

  • Mathematical modelling of the action potential of human embryonic stem cell derived cardiomyocytes.

    abstract:BACKGROUND:Human embryonic stem cell derived cardiomyocytes (hESC-CMs) hold high potential for basic and applied cardiovascular research. The development of a reliable simulation platform able to mimic the functional properties of hESC-CMs would be of considerable value to perform preliminary test complementing in vitr...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-11-61

    authors: Paci M,Sartiani L,Del Lungo M,Jaconi M,Mugelli A,Cerbai E,Severi S

    更新日期:2012-08-28 00:00:00

  • Neonatal non-contact respiratory monitoring based on real-time infrared thermography.

    abstract:BACKGROUND:Monitoring of vital parameters is an important topic in neonatal daily care. Progress in computational intelligence and medical sensors has facilitated the development of smart bedside monitors that can integrate multiple parameters into a single monitoring system. This paper describes non-contact monitoring...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-10-93

    authors: Abbas AK,Heimann K,Jergus K,Orlikowsky T,Leonhardt S

    更新日期:2011-10-20 00:00:00

  • Effect of glutaraldehyde based cross-linking on the viscoelasticity of mitral valve basal chordae tendineae.

    abstract:BACKGROUND:Mitral valve failure can require repair or replacement. Replacement bioprosthetic valves are treated with glutaraldehyde prior to implantation. The aim of this study was to determine the changes in mechanical properties following glutaraldehyde fixation of mitral valve chordae. METHODS:To investigate the im...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-018-0524-2

    authors: Constable M,Burton HE,Lawless BM,Gramigna V,Buchan KG,Espino DM

    更新日期:2018-07-13 00:00:00

  • Low-cost equipment for the evaluation of reach and grasp in post-stroke individuals: a pilot study.

    abstract:BACKGROUND:Reach-grasp movements are motor components commonly affected after stroke and directly related to the independence of these individuals. Evaluations of these activities can be performed using clinical instruments and assessed by detailed and costly kinematic analyses. The aim of this study was to develop an ...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-020-0758-7

    authors: Gomes CLA,Cacho RO,Nobrega VTB,de A Confessor EM,de Farias EEM,Neto JLF,de Araújo DS,de S Medeiros AL,Barreto RL,Cacho EWA

    更新日期:2020-03-04 00:00:00

  • Characterization of the head-to-trunk orientation with handheld optical 3D apparatus based on the fringe projection technique.

    abstract:BACKGROUND:Knowing the orientation of the head is important in many fields, including medicine. Many methods and measuring systems exist, but usually they use different markers or sensors attached to the subject's head for head orientation determination. In certain applications these attachments may represent a burden ...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-12-96

    authors: Pavlovčič U,Diaci J,Možina J,Jezeršek M

    更新日期:2013-09-26 00:00:00

  • Monitoring and analysis of dynamic growth of human embryonic stem cells: comparison of automated instrumentation and conventional culturing methods.

    abstract:BACKGROUND:Human embryonic stem cells (hESCs) are a potential source of cells for use in regenerative medicine. Automation of culturing, monitoring and analysis is crucial for fast and reliable optimization of hESC culturing methods. Continuous monitoring of living cell cultures can reveal more information and is faste...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-6-11

    authors: Narkilahti S,Rajala K,Pihlajamäki H,Suuronen R,Hovatta O,Skottman H

    更新日期:2007-04-12 00:00:00

  • Integrated EIT system for functional lung ventilation imaging.

    abstract:BACKGROUND:Electrical impedance tomography (EIT) has been used for functional lung imaging of regional air distributions during mechanical ventilation in intensive care units (ICU). From numerous clinical and animal studies focusing on specific lung functions, a consensus about how to use the EIT technique has been for...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-019-0701-y

    authors: Jang GY,Ayoub G,Kim YE,Oh TI,Chung CR,Suh GY,Woo EJ

    更新日期:2019-07-25 00:00:00

  • Study on the biomechanical responses of the loaded bone in macroscale and mesoscale by multiscale poroelastic FE analysis.

    abstract:BACKGROUND:Bone is a hierarchically structured composite material, and different hierarchical levels exhibit diverse material properties and functions. The stress and strain distribution and fluid flow in bone play an important role in the realization of mechanotransduction and bone remodeling. METHODS:To investigate ...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-019-0741-3

    authors: Yu W,Wu X,Cen H,Guo Y,Li C,Wang Y,Qin Y,Chen W

    更新日期:2019-12-23 00:00:00

  • A high-resolution binocular video-oculography system: assessment of pupillary light reflex and detection of an early incomplete blink and an upward eye movement.

    abstract:BACKGROUND:The pupillary light reflex characterizes the direct and consensual response of the eye to the perceived brightness of a stimulus. It has been used as indicator of both neurological and optic nerve pathologies. As with other eye reflexes, this reflex constitutes an almost instantaneous movement and is linked ...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-015-0016-6

    authors: Espinosa J,Roig AB,Pérez J,Mas D

    更新日期:2015-03-13 00:00:00

  • Development and mechanical testing of a short intramedullary nail for fixation of femoral rotational osteotomy in cerebral palsy patients.

    abstract:BACKGROUND:Rotational osteotomy is frequently indicated to correct excessive femoral anteversion in cerebral palsy patients. Angled blade plate is the standard fixation device used when performed in the proximal femur, but extensile exposure is required for plate accommodation. The authors developed a short locked intr...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-10-57

    authors: Pagnano RG,Okubo R,Volpon JB

    更新日期:2011-06-28 00:00:00

  • Comparison of human uterine cervical electrical impedance measurements derived using two tetrapolar probes of different sizes.

    abstract:BACKGROUND:We sought to compare uterine cervical electrical impedance spectroscopy measurements employing two probes of different sizes, and to employ a finite element model to predict and compare the fraction of electrical current derived from subepithelial stromal tissue. METHODS:Cervical impedance was measured in 1...

    journal_title:Biomedical engineering online

    pub_type: 临床试验,杂志文章

    doi:10.1186/1475-925X-5-62

    authors: Gandhi SV,Walker DC,Brown BH,Anumba DO

    更新日期:2006-11-24 00:00:00

  • Possibility of reconstruction of dental plaster cast from 3D digital study models.

    abstract:OBJECTIVES:To compare traditional plaster casts, digital models and 3D printed copies of dental plaster casts based on various criteria. To determine whether 3D printed copies obtained using open source system RepRap can replace traditional plaster casts in dental practice. To compare and contrast the qualities of two ...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-12-49

    authors: Kasparova M,Grafova L,Dvorak P,Dostalova T,Prochazka A,Eliasova H,Prusa J,Kakawand S

    更新日期:2013-05-31 00:00:00

  • On the viability of implantable electrodes for the natural control of artificial limbs: review and discussion.

    abstract::The control of robotic prostheses based on pattern recognition algorithms is a widely studied subject that has shown promising results in acute experiments. The long-term implementation of this technology, however, has not yet been achieved due to practical issues that can be mainly attributed to the use of surface el...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章,评审

    doi:10.1186/1475-925X-11-33

    authors: Ortiz-Catalan M,Brånemark R,Håkansson B,Delbeke J

    更新日期:2012-06-20 00:00:00

  • Evaluation of needle movement effect on root canal irrigation using a computational fluid dynamics model.

    abstract:BACKGROUND:Irrigation is considered to be a critical part of root canal treatment. However, little is known about the effect of needle movement on the irrigation process. Therefore, this study aimed to investigate the influence of the syringe and needle movement on root canal irrigation using a three-dimensional comput...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-019-0679-5

    authors: Hu S,Duan L,Wan Q,Wang J

    更新日期:2019-05-06 00:00:00

  • Dendritic tree extraction from noisy maximum intensity projection images in C. elegans.

    abstract:BACKGROUND:Maximum Intensity Projections (MIP) of neuronal dendritic trees obtained from confocal microscopy are frequently used to study the relationship between tree morphology and mechanosensory function in the model organism C. elegans. Extracting dendritic trees from noisy images remains however a strenuous proces...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-13-74

    authors: Greenblum A,Sznitman R,Fua P,Arratia PE,Oren M,Podbilewicz B,Sznitman J

    更新日期:2014-06-12 00:00:00

  • Influence of head models on EEG simulations and inverse source localizations.

    abstract:BACKGROUND:The structure of the anatomical surfaces, e.g., CSF and gray and white matter, could severely influence the flow of volume currents in a head model. This, in turn, will also influence the scalp potentials and the inverse source localizations. This was examined in detail with four different human head models....

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-5-10

    authors: Ramon C,Schimpf PH,Haueisen J

    更新日期:2006-02-08 00:00:00

  • A portable system with sample rate of 250 Hz for characterization of knee and hip angles in the sagittal plane during gait.

    abstract:BACKGROUND:Gait analysis and research have been developed to obtain characteristics of movement patterns of people while walking. However, traditional measuring systems present different drawbacks that reduce their use and application. Among those drawbacks one can find: high price, low sampling frequency and limiting ...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-13-34

    authors: Martínez-Solís F,Claudio-Sánchez A,Rodríguez-Lelis JM,Vergara-Limon S,Olivares-Peregrino V,Vargas-Treviño M

    更新日期:2014-03-31 00:00:00

  • An injection and mixing element for delivery and monitoring of inhaled nitric oxide.

    abstract:BACKGROUND:Inhaled nitric oxide (NO) is a selective pulmonary vasodilator used primarily in the critical care setting for patients concurrently supported by invasive or noninvasive positive pressure ventilation. NO delivery devices interface with ventilator breathing circuits to inject NO in proportion with the flow of...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-016-0227-5

    authors: Martin AR,Jackson C,Fromont S,Pont C,Katz IM,Caillobotte G

    更新日期:2016-08-30 00:00:00

  • Physical mechanism and modeling of heat generation and transfer in magnetic fluid hyperthermia through Néelian and Brownian relaxation: a review.

    abstract::Current clinically accepted technologies for cancer treatment still have limitations which lead to the exploration of new therapeutic methods. Since the past few decades, the hyperthermia treatment has attracted the attention of investigators owing to its strong biological rationales in applying hyperthermia as a canc...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章,评审

    doi:10.1186/s12938-017-0327-x

    authors: Suriyanto,Ng EY,Kumar SD

    更新日期:2017-03-23 00:00:00

  • Computational studies of the effects of myocardial blood flow reductions on cardiac metabolism.

    abstract:BACKGROUND:A computational model of myocardial energy metabolism was used to assess the metabolic responses to normal and reduced myocardial blood flow. The goal was to examine to what extent glycolysis and lactate formation are controlled by the supply of glycolytic substrate and/or the cellular redox (NADH/NAD+) and ...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-3-15

    authors: Salem JE,Stanley WC,Cabrera ME