3D marker-controlled watershed for kidney segmentation in clinical CT exams.

Abstract:

BACKGROUND:Image segmentation is an essential and non trivial task in computer vision and medical image analysis. Computed tomography (CT) is one of the most accessible medical examination techniques to visualize the interior of a patient's body. Among different computer-aided diagnostic systems, the applications dedicated to kidney segmentation represent a relatively small group. In addition, literature solutions are verified on relatively small databases. The goal of this research is to develop a novel algorithm for fully automated kidney segmentation. This approach is designed for large database analysis including both physiological and pathological cases. METHODS:This study presents a 3D marker-controlled watershed transform developed and employed for fully automated CT kidney segmentation. The original and the most complex step in the current proposition is an automatic generation of 3D marker images. The final kidney segmentation step is an analysis of the labelled image obtained from marker-controlled watershed transform. It consists of morphological operations and shape analysis. The implementation is conducted in a MATLAB environment, Version 2017a, using i.a. Image Processing Toolbox. 170 clinical CT abdominal studies have been subjected to the analysis. The dataset includes normal as well as various pathological cases (agenesis, renal cysts, tumors, renal cell carcinoma, kidney cirrhosis, partial or radical nephrectomy, hematoma and nephrolithiasis). Manual and semi-automated delineations have been used as a gold standard. Wieclawek Among 67 delineated medical cases, 62 cases are 'Very good', whereas only 5 are 'Good' according to Cohen's Kappa interpretation. The segmentation results show that mean values of Sensitivity, Specificity, Dice, Jaccard, Cohen's Kappa and Accuracy are 90.29, 99.96, 91.68, 85.04, 91.62 and 99.89% respectively. All 170 medical cases (with and without outlines) have been classified by three independent medical experts as 'Very good' in 143-148 cases, as 'Good' in 15-21 cases and as 'Moderate' in 6-8 cases. CONCLUSIONS:An automatic kidney segmentation approach for CT studies to compete with commonly known solutions was developed. The algorithm gives promising results, that were confirmed during validation procedure done on a relatively large database, including 170 CTs with both physiological and pathological cases.

journal_name

Biomed Eng Online

authors

Wieclawek W

doi

10.1186/s12938-018-0456-x

subject

Has Abstract

pub_date

2018-02-27 00:00:00

pages

26

issue

1

issn

1475-925X

pii

10.1186/s12938-018-0456-x

journal_volume

17

pub_type

杂志文章
  • Electrochemotherapy of colorectal liver metastases--an observational study of its effects on the electrocardiogram.

    abstract:BACKGROUND:Electrochemotherapy (ECT) is a combined treatment in which high voltage electroporation (EP) pulses are used to facilitate the uptake of a chemotherapeutic drug into tumor cells, thus increasing antitumor effectiveness of the drug. The effect of ECT of deep-seated tumors located close to the heart on functio...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-14-S3-S5

    authors: Mali B,Gorjup V,Edhemovic I,Brecelj E,Cemazar M,Sersa G,Strazisar B,Miklavcic D,Jarm T

    更新日期:2015-01-01 00:00:00

  • Multi-objective optimization of coronary stent using Kriging surrogate model.

    abstract:BACKGROUND:In stent design optimization, the functional relationship between design parameters and design goals is nonlinear, complex, and implicit and the multi-objective design of stents involves a number of potentially conflicting performance criteria. Therefore it is hard and time-consuming to find the optimal desi...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-016-0268-9

    authors: Li H,Gu J,Wang M,Zhao D,Li Z,Qiao A,Zhu B

    更新日期:2016-12-28 00:00:00

  • 3D kernel-density stochastic model for more personalized glycaemic control: development and in-silico validation.

    abstract:BACKGROUND:The challenges of glycaemic control in critically ill patients have been debated for 20 years. While glycaemic control shows benefits inter- and intra-patient metabolic variability results in increased hypoglycaemia and glycaemic variability, both increasing morbidity and mortality. Hence, current recommenda...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-019-0720-8

    authors: Uyttendaele V,Knopp JL,Davidson S,Desaive T,Benyo B,Shaw GM,Chase JG

    更新日期:2019-10-22 00:00:00

  • In-vivo coronary flow profiling based on biplane angiograms: influence of geometric simplifications on the three-dimensional reconstruction and wall shear stress calculation.

    abstract:BACKGROUND:Clinical studies suggest that local wall shear stress (WSS) patterns modulate the site and the progression of atherosclerotic lesions. Computational fluid dynamics (CFD) methods based on in-vivo three-dimensional vessel reconstructions have recently been shown to provide prognostically relevant WSS data. Thi...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-5-39

    authors: Wellnhofer E,Goubergrits L,Kertzscher U,Affeld K

    更新日期:2006-06-14 00:00:00

  • Influence of model boundary conditions on blood flow patterns in a patient specific stenotic right coronary artery.

    abstract:BACKGROUND:In literature, the effect of the inflow boundary condition was investigated by examining the impact of the waveform and the shape of the spatial profile of the inlet velocity on the cardiac hemodynamics. However, not much work has been reported on comparing the effect of the different combinations of the inl...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-14-S1-S6

    authors: Liu B,Zheng J,Bach R,Tang D

    更新日期:2015-01-01 00:00:00

  • The development and application of an oncology Therapy-Related Symptom Checklist for Adults (TRSC) and Children (TRSC-C) and e-health applications.

    abstract:BACKGROUND:Studies found that treatment symptoms of concern to oncology/hematology patients were greatly under-identified in medical records. On average, 11.0 symptoms were reported of concern to patients compared to 1.5 symptoms identified in their medical records. A solution to this problem is use of an electronic sy...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-14-S2-S1

    authors: Williams AR,Williams DD,Williams PD,Alemi F,Hesham H,Donley B,Kheirbek RE

    更新日期:2015-01-01 00:00:00

  • An improved level set method for vertebra CT image segmentation.

    abstract:BACKGROUND:Clinical diagnosis and therapy for the lumbar disc herniation requires accurate vertebra segmentation. The complex anatomical structure and the degenerative deformations of the vertebrae makes its segmentation challenging. METHODS:An improved level set method, namely edge- and region-based level set method ...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-12-48

    authors: Huang J,Jian F,Wu H,Li H

    更新日期:2013-05-28 00:00:00

  • Formulation of photon diffusion from spherical bioluminescent sources in an infinite homogeneous medium.

    abstract:BACKGROUND:The bioluminescent enzyme firefly luciferase (Luc) or variants of green fluorescent protein (GFP) in transformed cells can be effectively used to reveal molecular and cellular features of neoplasia in vivo. Tumor cell growth and regression in response to various therapies can be evaluated by using biolumines...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-3-12

    authors: Cong W,Wang LV,Wang G

    更新日期:2004-05-04 00:00:00

  • Microneurography as a tool to develop decoding algorithms for peripheral neuro-controlled hand prostheses.

    abstract:BACKGROUND:The usability of dexterous hand prostheses is still hampered by the lack of natural and effective control strategies. A decoding strategy based on the processing of descending efferent neural signals recorded using peripheral neural interfaces could be a solution to such limitation. Unfortunately, this choic...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-019-0659-9

    authors: Petrini FM,Mazzoni A,Rigosa J,Giambattistelli F,Granata G,Barra B,Pampaloni A,Guglielmelli E,Zollo L,Capogrosso M,Micera S,Raspopovic S

    更新日期:2019-04-08 00:00:00

  • Influence of the measurement method of features in ultrasound images of the thyroid in the diagnosis of Hashimoto's disease.

    abstract:INTRODUCTION:This paper shows the influence of a measurement method of features in the diagnosis of Hashimoto's disease. Sensitivity of the algorithm to changes in the parameters of the ROI, namely shift, resizing and rotation, has been presented. The obtained results were also compared to the methods known from the li...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-11-91

    authors: Koprowski R,Korzyńska A,Wróbel Z,Zieleźnik W,Witkowska A,Małyszek J,Wójcik W

    更新日期:2012-11-28 00:00:00

  • Open source model for generating RR intervals in atrial fibrillation and beyond.

    abstract:BACKGROUND:Realistic modeling of cardiac inter-beat (RR) intervals is highly desirable for basic research in cardiac electrophysiology, clinical management of heart diseases, and developing signal processing tools for ECG analysis. METHODS:We present an open source computer model that is capable to generate realistic ...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-6-9

    authors: Lian J,Clifford GD,Müssig D,Lang V

    更新日期:2007-03-02 00:00:00

  • On the design of a DEA-based device to pot entially assist lower leg disorders: an analytical and FEM investigation accounting for nonlinearities of the leg and device deformations.

    abstract:BACKGROUND:One of the recommended treatments for disorders associated with the lower extremity venous insufficiency is the application of external mechanical compression. Compression stockings and elastic bandages are widely used for the purpose of compression therapy and are usually designed to exert a specified value...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-015-0088-3

    authors: Pourazadi S,Ahmadi S,Menon C

    更新日期:2015-11-05 00:00:00

  • A numerical study of the effect of varied blood pressure on the stability of carotid atherosclerotic plaque.

    abstract:BACKGROUND:Blood pressure (BP) is associated with early atherosclerosis and plaque rupture because the BP variability can significantly affect the blood flow velocity and shear stress over the plaque. However, the mechanical response of BP variability to the plaque remains unclear. Therefore, we investigated the correl...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-13-152

    authors: Xiong H,Liu X,Tian X,Pu L,Zhang H,Lu M,Huang W,Zhang YT

    更新日期:2014-11-20 00:00:00

  • Home-based system for physical activity monitoring in patients with multiple sclerosis (Pilot study).

    abstract:BACKGROUND:Limitations in physical activity are considered as a key problem in patients with multiple sclerosis (PwMS). Contemporary methods to assess the level of physical activity in PwMS are regular clinical observation. However, these methods either rely on high recall and accurate reporting from the patients (e.g....

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-13-10

    authors: Shammas L,Zentek T,von Haaren B,Schlesinger S,Hey S,Rashid A

    更新日期:2014-02-06 00:00:00

  • In vivo and in vitro performance of a China-made hemodialysis machine: a multi-center prospective controlled study.

    abstract:OBJECTIVE:To evaluate the in vivo and in vitro performance of a China-made dialysis machine (SWS-4000). METHODS:This was a multi-center prospective controlled study consisting of both long-term in vitro evaluations and cross-over in vivo tests in 132 patients. The China-made SWS-4000 dialysis machine was compared with...

    journal_title:Biomedical engineering online

    pub_type: 临床试验,杂志文章,多中心研究

    doi:10.1186/s12938-017-0387-y

    authors: Wang Y,Chen XM,Cai GY,Li WG,Zhang AH,Hao LR,Shi M,Wang R,Jiang HL,Luo HM,Zhang D,Sun XF

    更新日期:2017-08-02 00:00:00

  • Human coronary plaque wall thickness correlated positively with flow shear stress and negatively with plaque wall stress: an IVUS-based fluid-structure interaction multi-patient study.

    abstract:BACKGROUND:Atherosclerotic plaque progression and rupture are believed to be associated with mechanical stress conditions. In this paper, patient-specific in vivo intravascular ultrasound (IVUS) coronary plaque image data were used to construct computational models with fluid-structure interaction (FSI) and cyclic bend...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-13-32

    authors: Fan R,Tang D,Yang C,Zheng J,Bach R,Wang L,Muccigrosso D,Billiar K,Zhu J,Ma G,Maehara A,Mintz GS

    更新日期:2014-03-26 00:00:00

  • Phantom-based experimental validation of fast virtual deployment of self-expandable stents for cerebral aneurysms.

    abstract:BACKGROUND:Endovascular intervention using a stent is a mainstream treatment for cerebral aneurysms. To assess the effect of intervention strategies on aneurysm hemodynamics, we have developed a fast virtual stenting (FVS) technique to simulate stent deployment in patient-specific aneurysms. However, quantitative valid...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-016-0250-6

    authors: Zhang Q,Meng Z,Zhang Y,Yao K,Liu J,Zhang Y,Jing L,Yang X,Paliwal N,Meng H,Wang S

    更新日期:2016-12-28 00:00:00

  • Simulating the swelling and deformation behaviour in soft tissues using a convective thermal analogy.

    abstract:BACKGROUND:It is generally accepted that cartilage adaptation and degeneration are mechanically mediated. Investigating the swelling behaviour of cartilage is important because the stress and strain state of cartilage is associated with the swelling and deformation behaviour. It is well accepted that the swelling of so...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925x-1-8

    authors: Wu JZ,Herzog W

    更新日期:2002-12-19 00:00:00

  • Investigations concerning the application of the cross-correlation method in cardiac output measurements.

    abstract:BACKGROUND:In spite of numerous non-invasive examinations the "gold clinical standard" of cardiac output measurements is the invasive pulmonary artery catheterization by means of the Swan-Ganz catheter and the application of the thermodilution method to estimate the blood flow. The results obtained by means of thermodi...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-11-24

    authors: Gawlikowski M,Pustelny T

    更新日期:2012-05-20 00:00:00

  • Three types of dermal grafts in rats: the importance of mechanical property and structural design.

    abstract:BACKGROUND:To determine how the mechanical property and micro structure affect tissue regeneration and angiogenesis, three types of scaffolds were studied. Acellular dermal matrices (ADM), produced from human skin by removing the epidermis and cells, has been widely used in wound healing because of its high mechanical ...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-12-125

    authors: You C,Wang X,Zheng Y,Han C

    更新日期:2013-12-04 00:00:00

  • Heart rate variability analysis using robust period detection.

    abstract:OBJECTIVE:Heart rate variability (HRV) analysis, which is an important tool for activity assessment of the cardiac autonomic nervous system, very often includes the estimation of power spectra for series of interbeat intervals (IBI). Ectopic beats and artifacts have a destructive effect on the standard methods (Fourier...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-13-138

    authors: Skotte JH,Kristiansen J

    更新日期:2014-09-23 00:00:00

  • Biomechanical investigation of dynamic hip screw and wire fixation on an unstable intertrochanteric fracture.

    abstract:BACKGROUND:Although use of a dynamic hip screw (DHS) for stable intertrochanteric hip fracture fixation has been successfully applied in fracture healing for more than 20 years, DHS fixation on unstable intertrochanteric fractures still has a high failure rate, especially in patients with osteoporosis. Although the wir...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-019-0663-0

    authors: Wu HF,Chang CH,Wang GJ,Lai KA,Chen CH

    更新日期:2019-04-24 00:00:00

  • Effect of manufacturing and experimental conditions on the mechanical and surface properties of silicone elastomer scaffolds used in endothelial mechanobiological studies.

    abstract:BACKGROUND:Mechanobiological studies allow the characterization of cell response to mechanical stresses. Cells need to be supported by a material with properties similar to the physiological environment. Silicone elastomers have been used to produce various in vitro scaffolds of different geometries for endothelial cel...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-017-0380-5

    authors: Campeau MA,Lortie A,Tremblay P,Béliveau MO,Dubé D,Langelier È,Rouleau L

    更新日期:2017-07-14 00:00:00

  • Challenges on optimization of 3D-printed bone scaffolds.

    abstract::Advances in biomaterials and the need for patient-specific bone scaffolds require modern manufacturing approaches in addition to a design strategy. Hybrid materials such as those with functionally graded properties are highly needed in tissue replacement and repair. However, their constituents, proportions, sizes, con...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章,评审

    doi:10.1186/s12938-020-00810-2

    authors: Bahraminasab M

    更新日期:2020-09-03 00:00:00

  • Colonoscopy procedure simulation: virtual reality training based on a real time computational approach.

    abstract:BACKGROUND:Colonoscopy plays an important role in the clinical screening and management of colorectal cancer. The traditional 'see one, do one, teach one' training style for such invasive procedure is resource intensive and ineffective. Given that colonoscopy is difficult, and time-consuming to master, the use of virtu...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-018-0433-4

    authors: Wen T,Medveczky D,Wu J,Wu J

    更新日期:2018-01-25 00:00:00

  • Exploiting nonlinear recurrence and fractal scaling properties for voice disorder detection.

    abstract:BACKGROUND:Voice disorders affect patients profoundly, and acoustic tools can potentially measure voice function objectively. Disordered sustained vowels exhibit wide-ranging phenomena, from nearly periodic to highly complex, aperiodic vibrations, and increased "breathiness". Modelling and surrogate data studies have s...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-6-23

    authors: Little MA,McSharry PE,Roberts SJ,Costello DA,Moroz IM

    更新日期:2007-06-26 00:00:00

  • Computer-aided analysis of micro-morphological structure of porous membranes.

    abstract:BACKGROUND:The paper presents an approach and computer-aided method of numerical evaluation of the quality of porous membranes used as scaffolds for cultivation of chondrocytes in regeneration of biological tissues. MATERIALS:The scanning electron microscope (SEM) images of 300× and 1000× magnification presenting the ...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-018-0481-9

    authors: Kulikowski JL,Przytulska M,Chwojnowski A

    更新日期:2018-05-30 00:00:00

  • Novel dynamic corneal response parameters in a practice use: a critical review.

    abstract:BACKGROUND:Non-contact tonometers based on the method using air puff and Scheimpflug's fast camera are one of the latest devices allowing the measurement of intraocular pressure and additional biomechanical parameters of the cornea. Biomechanical features significantly affect changes in intraocular pressure values, as ...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章,评审

    doi:10.1186/s12938-019-0636-3

    authors: Jędzierowska M,Koprowski R

    更新日期:2019-02-13 00:00:00

  • Challenges, issues and trends in fall detection systems.

    abstract::Since falls are a major public health problem among older people, the number of systems aimed at detecting them has increased dramatically over recent years. This work presents an extensive literature review of fall detection systems, including comparisons among various kinds of studies. It aims to serve as a referenc...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章,评审

    doi:10.1186/1475-925X-12-66

    authors: Igual R,Medrano C,Plaza I

    更新日期:2013-07-06 00:00:00

  • Modeling and classification of gait patterns between anterior cruciate ligament deficient and intact knees based on phase space reconstruction, Euclidean distance and neural networks.

    abstract:BACKGROUND:The anterior cruciate ligament (ACL) plays an important role in stabilizing translation and rotation of the tibia relative to the femur. ACL injury alters knee kinematics and usually links to the alternation of gait patterns. The aim of this study is to develop a new method to distinguish between gait patter...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-018-0594-1

    authors: Wu W,Zeng W,Ma L,Yuan C,Zhang Y

    更新日期:2018-11-01 00:00:00