Designing and testing scene enhancement algorithms for patients with retina degenerative disorders.

Abstract:

BACKGROUND:Retina degenerative disorders represent the primary cause of blindness in UK and in the developed world. In particular, Age Related Macular Degeneration (AMD) and Retina Pigmentosa (RP) diseases are of interest to this study. We have therefore created new image processing algorithms for enhancing the visual scenes for them. METHODS:In this paper we present three novel image enhancement techniques aimed at enhancing the remaining visual information for patients suffering from retina dystrophies. Currently, the only effective way to test novel technology for visual enhancement is to undergo testing on large numbers of patients. To test our techniques, we have therefore built a retinal image processing model and compared the results to data from patient testing. In particular we focus on the ability of our image processing techniques to achieve improved face detection and enhanced edge perception. RESULTS:Results from our model are compared to actual data obtained from testing the performance of these algorithms on 27 patients with an average visual acuity of 0.63 and an average contrast sensitivity of 1.22. Results show that Tinted Reduced Outlined Nature (TRON) and Edge Overlaying algorithms are most beneficial for dynamic scenes such as motion detection. Image Cartoonization was most beneficial for spatial feature detection such as face detection. Patient's stated that they would most like to see Cartoonized images for use in daily life. CONCLUSIONS:Results obtained from our retinal model and from patients show that there is potential for these image processing techniques to improve visual function amongst the visually impaired community. In addition our methodology using face detection and efficiency of perceived edges in determining potential benefit derived from different image enhancement algorithms could also prove to be useful in quantitatively assessing algorithms in future studies.

journal_name

Biomed Eng Online

authors

Al-Atabany WI,Memon MA,Downes SM,Degenaar PA

doi

10.1186/1475-925X-9-27

subject

Has Abstract

pub_date

2010-06-18 00:00:00

pages

27

issn

1475-925X

pii

1475-925X-9-27

journal_volume

9

pub_type

杂志文章
  • In vivo long-term investigation of tumor bearing mKate2 by an in-house fluorescence molecular imaging system.

    abstract:BACKGROUND:Optical imaging is one of the most common, low-cost imaging tools used for investigating the tumor biological behavior in vivo. This study explores the feasibility and sensitivity of a near infrared fluorescent protein mKate2 for a long-term non-invasive tumor imaging in BALB/c nude mice, by using a low-powe...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-018-0615-0

    authors: Zhou K,Ding Y,Vuletic I,Tian Y,Li J,Liu J,Huang Y,Sun H,Li C,Ren Q,Lu Y

    更新日期:2018-12-29 00:00:00

  • Evolutionary optimization of classifiers and features for single-trial EEG discrimination.

    abstract:BACKGROUND:State-of-the-art signal processing methods are known to detect information in single-trial event-related EEG data, a crucial aspect in development of real-time applications such as brain computer interfaces. This paper investigates one such novel approach, evaluating how individual classifier and feature sub...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-6-32

    authors: Aberg MC,Wessberg J

    更新日期:2007-08-23 00:00:00

  • Artery buckling affects the mechanical stress in atherosclerotic plaques.

    abstract:BACKGROUND:Tortuous arteries are often seen in patients with hypertension and atherosclerosis. While the mechanical stress in atherosclerotic plaque under lumen pressure has been studied extensively, the mechanical stability of atherosclerotic arteries and subsequent effect on the plaque stress remain unknown. To this ...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-14-S1-S4

    authors: Sanyal A,Han HC

    更新日期:2015-01-01 00:00:00

  • 3D marker-controlled watershed for kidney segmentation in clinical CT exams.

    abstract:BACKGROUND:Image segmentation is an essential and non trivial task in computer vision and medical image analysis. Computed tomography (CT) is one of the most accessible medical examination techniques to visualize the interior of a patient's body. Among different computer-aided diagnostic systems, the applications dedic...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-018-0456-x

    authors: Wieclawek W

    更新日期:2018-02-27 00:00:00

  • A reconfigurable arbitrary waveform generator using PWM modulation for ultrasound research.

    abstract:BACKGROUND:In ultrasound imaging systems, the digital transmit beamformer is a critical module that generates accurate control over several transmission parameters. However, such transmit front-end module is not typically accessible to ultrasound researchers. To overcome this difficulty, we have been developing a compa...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-12-24

    authors: Assef AA,Maia JM,Schneider FK,Button VL,Costa ET

    更新日期:2013-03-20 00:00:00

  • Correlations between carotid plaque progression and mechanical stresses change sign over time: a patient follow up study using MRI and 3D FSI models.

    abstract:BACKGROUND:Increasing evidence suggests that mechanisms governing advanced plaque progression may be different from those for early progression and require further investigation. Serial MRI data and 3D fluid-structure interaction (FSI) models were employed to identify possible correlations between mechanical stresses a...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-12-105

    authors: Tang D,Yang C,Canton G,Wu Z,Hatsukami T,Yuan C

    更新日期:2013-10-14 00:00:00

  • The effect of baseline pressure errors on an intracranial pressure-derived index: results of a prospective observational study.

    abstract:BACKGROUND:In order to characterize the intracranial pressure-volume reserve capacity, the correlation coefficient (R) between the ICP wave amplitude (A) and the mean ICP level (P), the RAP index, has been used to improve the diagnostic value of ICP monitoring. Baseline pressure errors (BPEs), caused by spontaneous shi...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-13-99

    authors: Eide PK,Sorteberg A,Meling TR,Sorteberg W

    更新日期:2014-07-23 00:00:00

  • Improved content aware scene retargeting for retinitis pigmentosa patients.

    abstract:BACKGROUND:In this paper we present a novel scene retargeting technique to reduce the visual scene while maintaining the size of the key features. The algorithm is scalable to implementation onto portable devices, and thus, has potential for augmented reality systems to provide visual support for those with tunnel visi...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-9-52

    authors: Al-Atabany WI,Tong T,Degenaar PA

    更新日期:2010-09-16 00:00:00

  • Conductivity image enhancement in MREIT using adaptively weighted spatial averaging filter.

    abstract:BACKGROUND:In magnetic resonance electrical impedance tomography (MREIT), we reconstruct conductivity images using magnetic flux density data induced by externally injected currents. Since we extract magnetic flux density data from acquired MR phase images, the amount of measurement noise increases in regions of weak M...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-13-87

    authors: Oh TI,Kim HJ,Jeong WC,Wi H,Kwon OI,Woo EJ

    更新日期:2014-06-26 00:00:00

  • A transition-constrained discrete hidden Markov model for automatic sleep staging.

    abstract:BACKGROUND:Approximately one-third of the human lifespan is spent sleeping. To diagnose sleep problems, all-night polysomnographic (PSG) recordings including electroencephalograms (EEGs), electrooculograms (EOGs) and electromyograms (EMGs), are usually acquired from the patient and scored by a well-trained expert accor...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-11-52

    authors: Pan ST,Kuo CE,Zeng JH,Liang SF

    更新日期:2012-08-21 00:00:00

  • On the design of a DEA-based device to pot entially assist lower leg disorders: an analytical and FEM investigation accounting for nonlinearities of the leg and device deformations.

    abstract:BACKGROUND:One of the recommended treatments for disorders associated with the lower extremity venous insufficiency is the application of external mechanical compression. Compression stockings and elastic bandages are widely used for the purpose of compression therapy and are usually designed to exert a specified value...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-015-0088-3

    authors: Pourazadi S,Ahmadi S,Menon C

    更新日期:2015-11-05 00:00:00

  • Atomic force microscopy in vitro study of surface roughness and fractal character of a dental restoration composite after air-polishing.

    abstract:BACKGROUND:Surface roughness is the main factor determining bacterial adhesion, biofilm growth and plaque formation on the dental surfaces in vivo. Air-polishing of dental surfaces removes biofilm but can also damage the surface by increasing its roughness. The purpose of this study was to investigate the surface damag...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-9-59

    authors: Salerno M,Giacomelli L,Derchi G,Patra N,Diaspro A

    更新日期:2010-10-12 00:00:00

  • Infrared thermography fails to visualize stimulation-induced meridian-like structures: comment by Rixin Chen and Zhimai Lv and reply from Gerhard Litscher.

    abstract::A comment on G. Litscher: Infrared thermography fails to visualize stimulation-induced meridian-like structures. Biomed. Eng. OnLine 2005, 4:38 (15 June 2005), with a response by the author. ...

    journal_title:Biomedical engineering online

    pub_type: 评论,信件

    doi:10.1186/1475-925X-10-80

    authors: Chen R,Lv Z

    更新日期:2011-09-11 00:00:00

  • Possibility of reconstruction of dental plaster cast from 3D digital study models.

    abstract:OBJECTIVES:To compare traditional plaster casts, digital models and 3D printed copies of dental plaster casts based on various criteria. To determine whether 3D printed copies obtained using open source system RepRap can replace traditional plaster casts in dental practice. To compare and contrast the qualities of two ...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-12-49

    authors: Kasparova M,Grafova L,Dvorak P,Dostalova T,Prochazka A,Eliasova H,Prusa J,Kakawand S

    更新日期:2013-05-31 00:00:00

  • Extraction of average neck flexion angle during swallowing in neutral and chin-tuck positions.

    abstract:BACKGROUND:A common but debated technique in the management of swallowing difficulties is the chin tuck swallow, where the neck is flexed forward prior to swallowing. Natural variations in chin tuck angles across individuals may contribute to the differential effectiveness of the technique. METHODOLOGY:To facilitate t...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-8-25

    authors: Hung D,Sejdić E,Steele CM,Chau T

    更新日期:2009-10-07 00:00:00

  • Monitoring and analysis of dynamic growth of human embryonic stem cells: comparison of automated instrumentation and conventional culturing methods.

    abstract:BACKGROUND:Human embryonic stem cells (hESCs) are a potential source of cells for use in regenerative medicine. Automation of culturing, monitoring and analysis is crucial for fast and reliable optimization of hESC culturing methods. Continuous monitoring of living cell cultures can reveal more information and is faste...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-6-11

    authors: Narkilahti S,Rajala K,Pihlajamäki H,Suuronen R,Hovatta O,Skottman H

    更新日期:2007-04-12 00:00:00

  • A high-resolution binocular video-oculography system: assessment of pupillary light reflex and detection of an early incomplete blink and an upward eye movement.

    abstract:BACKGROUND:The pupillary light reflex characterizes the direct and consensual response of the eye to the perceived brightness of a stimulus. It has been used as indicator of both neurological and optic nerve pathologies. As with other eye reflexes, this reflex constitutes an almost instantaneous movement and is linked ...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-015-0016-6

    authors: Espinosa J,Roig AB,Pérez J,Mas D

    更新日期:2015-03-13 00:00:00

  • Influence of vascular geometry on local hemodynamic parameters: phantom and small rodent study.

    abstract:BACKGROUND:Many studies have demonstrated that the geometry of the carotid bifurcation enables prediction of blood flow variation associated with atherosclerotic plaque formation. The phase angle between the arterial wall circumferential strain and its instantaneous wall shear stress is known as stress phase angle (SPA...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-018-0458-8

    authors: Niu L,Zhu X,Pan M,Derek A,Xu L,Meng L,Zheng H

    更新日期:2018-03-02 00:00:00

  • Growth rate and rupture rate of unruptured intracranial aneurysms: a population approach.

    abstract:BACKGROUND:Understanding aneurysm growth rate allows us to predict not only the current rupture risk, but also accumulated rupture risk in the future. However, determining growth rate of unruptured intracranial aneurysms often requires follow-up of patients for a long period of time so that significant growth can be ob...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-8-11

    authors: Jou LD,Mawad ME

    更新日期:2009-06-18 00:00:00

  • Home-based system for physical activity monitoring in patients with multiple sclerosis (Pilot study).

    abstract:BACKGROUND:Limitations in physical activity are considered as a key problem in patients with multiple sclerosis (PwMS). Contemporary methods to assess the level of physical activity in PwMS are regular clinical observation. However, these methods either rely on high recall and accurate reporting from the patients (e.g....

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-13-10

    authors: Shammas L,Zentek T,von Haaren B,Schlesinger S,Hey S,Rashid A

    更新日期:2014-02-06 00:00:00

  • Multi-objective optimization of coronary stent using Kriging surrogate model.

    abstract:BACKGROUND:In stent design optimization, the functional relationship between design parameters and design goals is nonlinear, complex, and implicit and the multi-objective design of stents involves a number of potentially conflicting performance criteria. Therefore it is hard and time-consuming to find the optimal desi...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-016-0268-9

    authors: Li H,Gu J,Wang M,Zhao D,Li Z,Qiao A,Zhu B

    更新日期:2016-12-28 00:00:00

  • Feature extraction for the analysis of colon status from the endoscopic images.

    abstract:BACKGROUND:Extracting features from the colonoscopic images is essential for getting the features, which characterizes the properties of the colon. The features are employed in the computer-assisted diagnosis of colonoscopic images to assist the physician in detecting the colon status. METHODS:Endoscopic images contai...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925x-2-9

    authors: Tjoa MP,Krishnan SM

    更新日期:2003-04-08 00:00:00

  • Patterned thin metal film for the lateral resolution measurement of photoacoustic tomography.

    abstract:BACKGROUND:Image quality assessment method of photoacoustic tomography has not been completely standardized yet. Due to the combined nature of photonic signal generation and ultrasonic signal transmission in biological tissue, neither optical nor ultrasonic traditional methods can be used without modification. An optic...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-11-37

    authors: Kim DH,Shin DH,Ryu SH,Song CG

    更新日期:2012-07-13 00:00:00

  • PDE based scheme for multi-modal medical image watermarking.

    abstract:BACKGROUND:This work deals with copyright protection of digital images, an issue that needs protection of intellectual property rights. It is an important issue with a large number of medical images interchanged on the Internet every day. So, it is a challenging task to ensure the integrity of received images as well a...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-015-0101-x

    authors: Aherrahrou N,Tairi H

    更新日期:2015-11-25 00:00:00

  • The approximate entropy of the electromyographic signals of tremor correlates with the osmotic fragility of human erythrocytes.

    abstract:BACKGROUND:The main problem of tremor is the damage caused to the quality of the life of patients, especially those at more advanced ages. There is not a consensus yet about the origins of this disorder, but it can be examined in the correlations between the biological signs of aging and the tremor characteristics. ME...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-9-29

    authors: Mansur PH,Cury LK,Leite JO,Pereira AA,Penha-Silva N,Andrade AO

    更新日期:2010-06-22 00:00:00

  • Two-stage CNNs for computerized BI-RADS categorization in breast ultrasound images.

    abstract:BACKGROUND:Quantizing the Breast Imaging Reporting and Data System (BI-RADS) criteria into different categories with the single ultrasound modality has always been a challenge. To achieve this, we proposed a two-stage grading system to automatically evaluate breast tumors from ultrasound images into five categories bas...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-019-0626-5

    authors: Huang Y,Han L,Dou H,Luo H,Yuan Z,Liu Q,Zhang J,Yin G

    更新日期:2019-01-24 00:00:00

  • NeoAnalysis: a Python-based toolbox for quick electrophysiological data processing and analysis.

    abstract:BACKGROUND:In a typical electrophysiological experiment, especially one that includes studying animal behavior, the data collected normally contain spikes, local field potentials, behavioral responses and other associated data. In order to obtain informative results, the data must be analyzed simultaneously with the ex...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-017-0419-7

    authors: Zhang B,Dai J,Zhang T

    更新日期:2017-11-13 00:00:00

  • Hemodynamic numerical simulations of the disturbance due to intracoronary flow measurements by a Doppler guide wire.

    abstract:BACKGROUND:Since hemodynamics plays a key role in the development and evolution of cardiovascular pathologies, physician's decision must be based on proper monitoring of relevant physiological flow quantities. METHODS:A numerical analysis of the error introduced by an intravascular Doppler guide wire on the peak veloc...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/s12938-016-0234-6

    authors: Chodzyński KJ,Gremmo S,Eker OF,Lalmand J,Aminian A,de Sousa DR,Boudjeltia KZ,Coussement G

    更新日期:2016-10-10 00:00:00

  • Open source model for generating RR intervals in atrial fibrillation and beyond.

    abstract:BACKGROUND:Realistic modeling of cardiac inter-beat (RR) intervals is highly desirable for basic research in cardiac electrophysiology, clinical management of heart diseases, and developing signal processing tools for ECG analysis. METHODS:We present an open source computer model that is capable to generate realistic ...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-6-9

    authors: Lian J,Clifford GD,Müssig D,Lang V

    更新日期:2007-03-02 00:00:00

  • Virtual environment to quantify the influence of colour stimuli on the performance of tasks requiring attention.

    abstract:BACKGROUND:Recent studies indicate that the blue-yellow colour discrimination is impaired in ADHD individuals. However, the relationship between colour and performance has not been investigated. This paper describes the development and the testing of a virtual environment that is capable to quantify the influence of re...

    journal_title:Biomedical engineering online

    pub_type: 杂志文章

    doi:10.1186/1475-925X-10-74

    authors: Silva AP,Frère AF

    更新日期:2011-08-19 00:00:00