Simulation of swallowing dysfunction and mechanical ventilation after a Montgomery T-tube insertion.

Abstract:

:The Montgomery T-tube is used as a combined tracheal stent and airway after laryngotracheoplasty, to keep the lumen open and prevent mucosal laceration from scarring. It is valuable in the management of upper and mid-tracheal lesions, while invaluable in long and multisegmental stenting lesions. Numerical simulations based on real-patient-tracheal geometry, experimental tissue characterization, and previous numerical estimation of the physiological swallowing force are performed to estimate the consequences of Montgomery T-tube implantation on swallowing and assisted ventilation: structural analysis of swallowing is performed to evaluate patient swallowing capacity, and computational fluid dynamics simulation is carried out to analyze related mechanical ventilation. With an inserted Montgomery T-tube, vertical displacement (Z-axis) reaches 8.01 mm, whereas in the Y-axis, it reaches 6.63 mm. The maximal principal stress obtained during swallowing was 1.6 MPa surrounding the hole and in the upper contact with the tracheal wall. Fluid flow simulation of the mechanical ventilation revealed positive pressure for both inhalation and exhalation, being higher for inspiration. The muscular deflections, considerable during normal breathing, are nonphysiological, and this aspect results in a constant overload of the tracheal muscle. During swallowing, the trachea ascends producing a nonhomogeneous elongation. This movement can be compromised when prosthesis is inserted, which explains the high incidence of glottis close inefficiency. Fluid simulations showed that nonphysiological pressure is established inside the trachea due to mechanical ventilation. This may lead to an overload of the tracheal muscle, explaining several related problems as muscle thinning or decrease in contractile function.

authors

Trabelsi O,Malvè M,Mena Tobar A,Doblaré M

doi

10.1080/10255842.2014.930448

subject

Has Abstract

pub_date

2015-01-01 00:00:00

pages

1596-605

issue

14

eissn

1025-5842

issn

1476-8259

journal_volume

18

pub_type

杂志文章
  • The impact of calcification patterns in transcatheter aortic valve performance: a fluid-structure interaction analysis.

    abstract::Transcatheter aortic valve replacement (TAVR) strongly depends on the calcification patterns, which may lead to a malapposition of the stented valve and complication onsets in terms of structure kinematics and paravalvular leakage (PVL). From one anatomical-resembling model of the aortic root, six configurations with ...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255842.2020.1817409

    authors: Luraghi G,Matas JFR,Beretta M,Chiozzi N,Iannetti L,Migliavacca F

    更新日期:2020-09-14 00:00:00

  • A semi-automated method for hexahedral mesh construction of human vertebrae from CT scans.

    abstract::Generation of finite element (FE) meshes of vertebrae from computed tomography (CT) scans is labour intensive due to their geometric complexity. As such, techniques that simplify creation of meshes of vertebrae are needed to make FE analysis feasible for large studies and clinical applications. Techniques to obtain a ...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255840902802883

    authors: Dai Y,Niebur GL

    更新日期:2009-10-01 00:00:00

  • Finite element models of the thigh-buttock complex for assessing static sitting discomfort and pressure sore risk: a literature review.

    abstract::Being seated for long periods, while part of many leisure or occupational activities, can lead to discomfort, pain and sometimes health issues. The impact of prolonged sitting on the body has been widely studied in the literature, with a large number of human-body finite element models developed to simulate sitting an...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章,评审

    doi:10.1080/10255842.2018.1466117

    authors: Savonnet L,Wang X,Duprey S

    更新日期:2018-03-01 00:00:00

  • The Biomechanical Effects of Sagittal Split Ramus Osteotomy on Temporomandibular Joint.

    abstract::The aim of this study was to evaluate the stress distributions and deformations of the temporomandibular joint (TMJ) during different periods before and after sagittal split ramus osteotomy (SSRO). A three-dimensional finite element model of the mandible and TMJ was established, based on the preoperative CT of a patie...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255842.2018.1504034

    authors: Liu Z,Shu J,Zhang Y,Fan Y

    更新日期:2018-08-01 00:00:00

  • Implementation and validation of probabilistic models of the anterior longitudinal ligament and posterior longitudinal ligament of the cervical spine.

    abstract::The objective of this investigation was to develop probabilistic finite element (FE) models of the anterior longitudinal ligament (ALL) and posterior longitudinal ligament (PLL) of the cervical spine that incorporate the natural variability of biological specimens. In addition to the model development, a rigorous vali...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255842.2012.726353

    authors: Francis WL,Eliason TD,Thacker BH,Paskoff GR,Shender BS,Nicolella DP

    更新日期:2014-01-01 00:00:00

  • How does muscle stiffness affect the internal deformations within the soft tissue layers of the buttocks under constant loading?

    abstract::Mechanical loading of soft tissues covering bony prominences can cause skeletal muscle damage, ultimately resulting in a severe pressure ulcer termed deep tissue injury (DTI). Deformation plays an important role in the aetiology of DTI. Therefore, it is essential to minimise internal muscle deformations in subjects at...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255842.2011.627682

    authors: Loerakker S,Solis LR,Bader DL,Baaijens FP,Mushahwar VK,Oomens CW

    更新日期:2013-01-01 00:00:00

  • Effect of the degree of polar mismatching on traffic jam formation in fast axonal transport.

    abstract::This paper simulates an axon with a region of reversed microtubule (MT) polarity, and investigates how the degree of polar mismatching in this region affects the formation of organelle traps in the axon. The model is based on modified Smith-Simmons equations governing molecular-motor-assisted transport in neurons. It ...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255840903505154

    authors: Kuznetsov AV

    更新日期:2010-12-01 00:00:00

  • Quantitative underwater 3D motion analysis using submerged video cameras: accuracy analysis and trajectory reconstruction.

    abstract::In this study we aim at investigating the applicability of underwater 3D motion capture based on submerged video cameras in terms of 3D accuracy analysis and trajectory reconstruction. Static points with classical direct linear transform (DLT) solution, a moving wand with bundle adjustment and a moving 2D plate with Z...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255842.2012.664637

    authors: Silvatti AP,Cerveri P,Telles T,Dias FA,Baroni G,Barros RM

    更新日期:2013-01-01 00:00:00

  • Fluid-solid interaction in arteries incorporating the autoregulation concept in boundary conditions.

    abstract::In pre-surgery decisions in hospital emergency cases, fast and reliable results of the solid and fluid mechanics problems are of great interest to clinicians. In the current investigation, an iterative process based on a pressure-type boundary condition is proposed in order to reduce the computational costs of blood f...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255842.2015.1085026

    authors: Afkari D,Gabaldón F

    更新日期:2016-01-01 00:00:00

  • Feature selection based on a fuzzy complementary criterion: application to gait recognition using ground reaction forces.

    abstract::An efficient wavelet-based feature selection (FS) method is proposed in this paper for subject recognition using ground reaction force measurements. Our approach relies on a local fuzzy evaluation measure with respect to patterns that reveal the adequacy of data coverage for each feature. Furthermore, FS is driven by ...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255842.2011.554408

    authors: Moustakidis SP,Theocharis JB,Giakas G

    更新日期:2012-01-01 00:00:00

  • The influence of the way the muscle force is modeled on the predicted results obtained by solving indeterminate problems for a fast elbow flexion.

    abstract::A critical point in models of the human limbs when the aim is to investigate the motor control is the muscle model. More often the mechanical output of a muscle is considered as one musculotendon force that is a design variable in optimization tasks solved predominantly by static optimization. For dynamic conditions, ...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/1025584031000149097

    authors: Raikova R,Aladjov H

    更新日期:2003-06-01 00:00:00

  • Finite element analysis of a hemi-pelvis: the effect of inclusion of cartilage layer on acetabular stresses and strain.

    abstract::An appropriate method of application of the hip-joint force and stress analysis of the pelvic bone, in particular the acetabulum, is necessary to investigate the changes in load transfer due to implantation and to calculate the reference stimulus for bone remodelling simulations. The purpose of the study is to develop...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255842.2013.843674

    authors: Ghosh R,Pal B,Ghosh D,Gupta S

    更新日期:2015-01-01 00:00:00

  • A reliability measure of protein-protein interactions and a reliability measure-based search engine.

    abstract::Many methods developed for estimating the reliability of protein-protein interactions are based on the topology of protein-protein interaction networks. This paper describes a new reliability measure for protein-protein interactions, which does not rely on the topology of protein interaction networks, but expresses bi...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255842.2010.494039

    authors: Park B,Han K

    更新日期:2010-02-01 00:00:00

  • Comparing parametric solid modelling/reconfiguration, global shape modelling and free-form deformation for the generation of 3D digital models of femurs from X-ray images.

    abstract::At present, computer assisted surgery systems help orthopaedic surgeons both plan and perform surgical procedures. To enable these systems to function, it is crucial to have at one's disposal 3D models of anatomical structures, surgical tools and prostheses (if required). This paper analyses and compares three methods...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255840903077329

    authors: Filippi S,Motyl B,Bandera C

    更新日期:2009-02-01 00:00:00

  • Further Roles of Geometry and Properties in the Mechanics of Saccular Aneurysms.

    abstract::Rupture of intracranial saccular aneurysms continues to result in significant morbidity and mortality. Although it has long been thought that biomechanical factors play key roles in the genesis, growth, and rupture of these lesions, few analysis have employed realistic descriptions of the geometries and material prope...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/01495739708936698

    authors: Shah AD,Harris JL,Kyriacou SK,Humphrey JD

    更新日期:1998-01-01 00:00:00

  • Quantification of soft tissue balance in total knee arthroplasty using finite element analysis.

    abstract::Unbalanced contact force on the tibial component has been considered a factor leading to loosening of the implant and increased wear of the bearing surface in total knee arthroplasty. Because it has been reported that good alignment cannot guarantee successful clinical outcomes, the soft tissue balance should be check...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255842.2013.765409

    authors: Oh KJ,Park WM,Kim K,Kim YH

    更新日期:2014-01-01 00:00:00

  • Assessment of a fictitious domain method for patient-specific biomechanical modelling of press-fit orthopaedic implantation.

    abstract::In this article, we discuss an application of a fictitious domain method to the numerical simulation of the mechanical process induced by press-fitting cementless femoral implants in total hip replacement surgeries. Here, the primary goal is to demonstrate the feasibility of the method and its advantages over competin...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255842.2010.545822

    authors: Kallivokas LF,Na SW,Ghattas O,Jaramaz B

    更新日期:2012-01-01 00:00:00

  • Virtual power based algorithm for decoupling large motions from infinitesimal strains: application to shoulder joint biomechanics.

    abstract::New trends of numerical models of human joints require more and more computation of both large amplitude joint motions and fine bone stress distribution. Together, these problems are difficult to solve and very CPU time consuming. The goal of this study is to develop a new method to diminish the calculation time for t...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/1025584021000016843

    authors: Büchler P,Rakotomanana L,Farron A

    更新日期:2002-12-01 00:00:00

  • Influence of a postural change of the swimmer's head in hydrodynamic performances using 3D CFD.

    abstract::This study deals with recent researches undertaken by the authors in the field of hydrodynamics of human swimming. The aim of this numerical study was to investigate the flow around the entire swimmer's body. The results presented in this article focus on the combination of a 3D computational fluid dynamics code and t...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255842.2012.683429

    authors: Popa CV,Arfaoui A,Fohanno S,Taïar R,Polidori G

    更新日期:2014-01-01 00:00:00

  • Assessment of mechanical integrity for drug-eluting renal stent with micro-sized drug reservoirs.

    abstract::The drug-eluting stent (DES) has become the gold standard worldwide for the treatment of cardiovascular diseases. In recent years, an innovative variation of the DES with micro-sized drug reservoirs has been introduced. It allows programmable drug delivery with both spatial and temporal control and has several potenti...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255842.2012.670851

    authors: Hsiao HM,Chiu YH

    更新日期:2013-01-01 00:00:00

  • Automated gap-filling for marker-based biomechanical motion capture data.

    abstract::Marker-based motion capture presents the problem of gaps, which are traditionally processed using motion capture software, requiring intensive manual input. We propose and study an automated method of gap-filling that uses inverse kinematics (IK) to close the loop of an iterative process to minimize error, while nearl...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255842.2020.1789971

    authors: Camargo J,Ramanathan A,Csomay-Shanklin N,Young A

    更新日期:2020-11-01 00:00:00

  • Muscle parameters estimation based on biplanar radiography.

    abstract::The evaluation of muscle and joint forces in vivo is still a challenge. Musculo-Skeletal (musculo-skeletal) models are used to compute forces based on movement analysis. Most of them are built from a scaled-generic model based on cadaver measurements, which provides a low level of personalization, or from Magnetic Res...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255842.2016.1171855

    authors: Dubois G,Rouch P,Bonneau D,Gennisson JL,Skalli W

    更新日期:2016-11-01 00:00:00

  • The Influence of Flow on the Concentration of Platelet Active Substances in the Vicinity of Mural Microthrombi.

    abstract::The flow effect on the concentration of platelet active substances in the vicinity of a mural microthrombus is investigated numerically. A three-dimensional model is employed in which the mural microthrombus is modelled as a semisphere attached to a plane surface. The description of the blood flow uses the three-dimen...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/01495739808936708

    authors: Karner G,Perktold K

    更新日期:1998-01-01 00:00:00

  • Determining the location of hip joint centre: application of a conchoid's shape to the acetabular cartilage surface of magnetic resonance images.

    abstract::Preoperative planning, or intraoperative navigation of hip surgery, including joint-preserving procedures such as osteotomy or joint-replacing procedures such as total arthroplasty, needs to be performed with a high degree of accuracy to ensure a successful outcome. The ability to precisely localise the hip joint rota...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255842.2010.495064

    authors: Kang MJ,Sadri H,Stern R,Magnenat-Thalmann N,Hoffmeyer P,Ji HS

    更新日期:2011-01-01 00:00:00

  • A finite element model of the face including an orthotropic skin model under in vivo tension.

    abstract::Computer models of the human face have the potential to be used as powerful tools in surgery simulation and animation development applications. While existing models accurately represent various anatomical features of the face, the representation of the skin and soft tissues is very simplified. A computer model of the...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255842.2013.820720

    authors: Flynn C,Stavness I,Lloyd J,Fels S

    更新日期:2015-01-01 00:00:00

  • Identification and characterisation of regional variations in the material properties of ureter according to microstructure.

    abstract::There are few previous studies on the elastic properties of ureter and most have been limited to essentially one-dimensional deformation measurements. The object of this study was, therefore, to identify regional variations in the multiaxial behaviour of rabbit ureter, subjected to in vitro inflation/extension testing...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255842.2012.761692

    authors: Sokolis DP

    更新日期:2014-11-01 00:00:00

  • A computational study of systemic hydration in vocal fold collision.

    abstract::Mechanical stresses develop within vocal fold (VF) soft tissues due to phonation-associated vibration and collision. These stresses in turn affect the hydration of VF tissue and thus influence voice health. In this paper, high-fidelity numerical computations are described, taking into account fully 3D geometry, realis...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255842.2013.772591

    authors: Bhattacharya P,Siegmund T

    更新日期:2014-01-01 00:00:00

  • Study of age-related changes in Middle ear transfer function.

    abstract::Osteoporosis (OP) is common with advancing age. Several studies have shown a strong correlation between OP and otosclerosis. However, no studies have investigated OP of the malleus, incus or stapes in the human middle ear, its effect on middle ear transfer function. Here, we investigate whether these three ossicles de...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255842.2019.1632297

    authors: Zhou L,Shen N,Feng M,Liu H,Duan M,Huang X

    更新日期:2019-10-01 00:00:00

  • Proposition of an outflow boundary approach for carotid artery stenosis CFD simulation.

    abstract::The purpose of this study was to propose an innovative approach of setting outlet boundary conditions for the computational fluid dynamics (CFD) simulation of human common carotid arteries (CCAs) bifurcation based on the concept of energy loss minimisation at flow bifurcation. Comparisons between this new approach and...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255842.2011.625358

    authors: Zhang Y,Furusawa T,Sia SF,Umezu M,Qian Y

    更新日期:2013-01-01 00:00:00

  • Influence of fluid-flow direction on effective permeability of the vertebral end plate: an analytical model.

    abstract::Convective transports in the vertebral end plate (VEP) play a significant role in the homeostasis of the spine. A few studies hypothesised that the hydraulic resistance or effective permeability of the VEP could be dependant upon fluid-flow direction. Results were influenced by species, region of interest within the e...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255842.2010.518960

    authors: Swider P,Accadbled F,Laffosse JM,Sales de Gauzy J

    更新日期:2012-01-01 00:00:00