Assessment of mechanical integrity for drug-eluting renal stent with micro-sized drug reservoirs.

Abstract:

:The drug-eluting stent (DES) has become the gold standard worldwide for the treatment of cardiovascular diseases. In recent years, an innovative variation of the DES with micro-sized drug reservoirs has been introduced. It allows programmable drug delivery with both spatial and temporal control and has several potential advantages over traditional DESs. However, creating such reservoirs on the stent struts may weaken the structure of the stent scaffolding and compromise its mechanical integrity. In this study, we propose to use this innovative stent concept in the renal indication for potential treatment of both renal artery stenosis (upstream) and its associated kidney diseases (downstream) at the same time. The effects of these micro-sized drug reservoirs on several key clinically relevant functional attributes of the drug-eluting renal stent were systematically and quantitatively investigated. Finite element models were developed to predict the mechanical integrity of a balloon-expandable stent at various stages. Results show that (1) creating drug reservoirs on a stent could impact the stent fatigue resistance to certain degrees; (2) drug reservoirs on the stent crowns lead to greater loss in all key stent attributes than reservoirs on either bar arms or connectors and (3) the proposed optimised depot stent was proven to be feasible and could triple drug capacity than the current DESs, with marginal trade-off in its key clinical attributes. These results can serve as the guidelines to help future stent designs to achieve the best combination of stent structural integrity and smart drug delivery in the future.

authors

Hsiao HM,Chiu YH

doi

10.1080/10255842.2012.670851

subject

Has Abstract

pub_date

2013-01-01 00:00:00

pages

1307-18

issue

12

eissn

1025-5842

issn

1476-8259

journal_volume

16

pub_type

杂志文章
  • Simulation of the behaviour of the L1 vertebra for different material properties and loading conditions.

    abstract::Three-dimensional finite element models of the thoracolumbar junction (T12-L2) and isolated L1 vertebra were developed to investigate the role of material properties and loading conditions on vertebral stresses and strains to predict fracture risk. The geometry of the vertebrae was obtained from computed tomography im...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255842.2011.636741

    authors: Erdem I,Truumees E,van der Meulen MC

    更新日期:2013-01-01 00:00:00

  • Identification and characterisation of regional variations in the material properties of ureter according to microstructure.

    abstract::There are few previous studies on the elastic properties of ureter and most have been limited to essentially one-dimensional deformation measurements. The object of this study was, therefore, to identify regional variations in the multiaxial behaviour of rabbit ureter, subjected to in vitro inflation/extension testing...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255842.2012.761692

    authors: Sokolis DP

    更新日期:2014-11-01 00:00:00

  • Muscle parameters estimation based on biplanar radiography.

    abstract::The evaluation of muscle and joint forces in vivo is still a challenge. Musculo-Skeletal (musculo-skeletal) models are used to compute forces based on movement analysis. Most of them are built from a scaled-generic model based on cadaver measurements, which provides a low level of personalization, or from Magnetic Res...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255842.2016.1171855

    authors: Dubois G,Rouch P,Bonneau D,Gennisson JL,Skalli W

    更新日期:2016-11-01 00:00:00

  • Understanding ageing effects using complexity analysis of foot-ground clearance during walking.

    abstract::Ageing influences gait patterns which in turn can affect the balance control of human locomotion. Entropy-based regularity and complexity measures have been highly effective in analysing a broad range of physiological signals. Minimum toe clearance (MTC) is an event during the swing phase of the gait cycle and is high...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255842.2011.628943

    authors: Karmakar C,Khandoker A,Begg R,Palaniswami M

    更新日期:2013-01-01 00:00:00

  • Customized k-nearest neighbourhood analysis in the management of adolescent idiopathic scoliosis using 3D markerless asymmetry analysis.

    abstract::Adolescent Idiopathic Scoliosis (AIS) is a 3D spinal deformity characterized by curvature and rotation of the spine. Markerless surface topography (ST) analysis has been proposed for diagnosing and monitoring AIS to reduce the X-ray radiation exposure to patients. This method captures scans of the cosmetic deformity o...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255842.2019.1584795

    authors: Ghaneei M,Ekyalimpa R,Westover L,Parent EC,Adeeb S

    更新日期:2019-05-01 00:00:00

  • A finite element comparison between the mechanical behaviour of rigid and resilient oral implants with respect to immediate loading.

    abstract::In this paper, a qualitative comparison between two types of dental implants with respect to their behaviour under immediate loading is presented. This analysis has been carried out using the finite element method. Since micromotions (and not the load) are responsible of the appearance of a fibrous interface avoiding ...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255840500141593

    authors: Pérez del Palomar A,Arruga A,Cegoñino J,Doblaré M

    更新日期:2005-02-01 00:00:00

  • Haemodynamic assessment of human coronary arteries is affected by degree of freedom of artery movement.

    abstract::Abnormal haemodynamic parameters are associated with atheroma plaque progression and instability in coronary arteries. Flow recirculation, shear stress and pressure gradient are understood to be important pathogenic mediators in coronary disease. The effect of freedom of coronary artery movement on these parameters is...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255842.2016.1215439

    authors: Javadzadegan A,Yong AS,Chang M,Ng MK,Behnia M,Kritharides L

    更新日期:2017-02-01 00:00:00

  • Performance criteria for generating predictive optimal control simulations of bicycle pedaling.

    abstract::The purpose of this study was to identify one or more performance-based criteria that may be used to generate predictive optimal control simulations of submaximal pedaling. Two-legged pedaling simulations were generated based on minimizing muscle activation, muscle stress, metabolic energy, time derivative of muscle f...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255842.2018.1522535

    authors: Gidley AD,Marsh AP,Umberger BR

    更新日期:2019-01-01 00:00:00

  • A Finite Element Approach for Skeletal Muscle using a Distributed Moment Model of Contraction.

    abstract::The present paper describes a geometrically and physically nonlinear continuum model to study the mechanical behaviour of passive and active skeletal muscle. The contraction is described with a Huxley type model. A Distributed Moments approach is used to convert the Huxley partial differential equation in a set of ord...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255840008915267

    authors: Gielen AW,Oomens CW,Bovendeerd PH,Arts T,Janssen JD

    更新日期:2000-01-01 00:00:00

  • A semi-automated method for hexahedral mesh construction of human vertebrae from CT scans.

    abstract::Generation of finite element (FE) meshes of vertebrae from computed tomography (CT) scans is labour intensive due to their geometric complexity. As such, techniques that simplify creation of meshes of vertebrae are needed to make FE analysis feasible for large studies and clinical applications. Techniques to obtain a ...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255840902802883

    authors: Dai Y,Niebur GL

    更新日期:2009-10-01 00:00:00

  • Numerical simulation of non-Newtonian blood flow dynamics in human thoracic aorta.

    abstract::Three non-Newtonian blood viscosity models plus the Newtonian one are analysed for a patient-specific thoracic aorta anatomical model under steady-state flow conditions via wall shear stress (WSS) distribution, non-Newtonian importance factors, blood viscosity and shear rate. All blood viscosity models yield a consist...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255842.2014.887698

    authors: Caballero AD,Laín S

    更新日期:2015-08-01 00:00:00

  • A new training algorithm using artificial neural networks to classify gender-specific dynamic gait patterns.

    abstract::The aim of this study was to present a new training algorithm using artificial neural networks called multi-objective least absolute shrinkage and selection operator (MOBJ-LASSO) applied to the classification of dynamic gait patterns. The movement pattern is identified by 20 characteristics from the three components o...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255842.2013.803081

    authors: Andrade A,Costa M,Paolucci L,Braga A,Pires F,Ugrinowitsch H,Menzel HJ

    更新日期:2015-01-01 00:00:00

  • A computational study of systemic hydration in vocal fold collision.

    abstract::Mechanical stresses develop within vocal fold (VF) soft tissues due to phonation-associated vibration and collision. These stresses in turn affect the hydration of VF tissue and thus influence voice health. In this paper, high-fidelity numerical computations are described, taking into account fully 3D geometry, realis...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255842.2013.772591

    authors: Bhattacharya P,Siegmund T

    更新日期:2014-01-01 00:00:00

  • Assessment of a fictitious domain method for patient-specific biomechanical modelling of press-fit orthopaedic implantation.

    abstract::In this article, we discuss an application of a fictitious domain method to the numerical simulation of the mechanical process induced by press-fitting cementless femoral implants in total hip replacement surgeries. Here, the primary goal is to demonstrate the feasibility of the method and its advantages over competin...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255842.2010.545822

    authors: Kallivokas LF,Na SW,Ghattas O,Jaramaz B

    更新日期:2012-01-01 00:00:00

  • Foot internal stress distribution during impact in barefoot running as function of the strike pattern.

    abstract::The aim of the present study is to examine the impact absorption mechanism of the foot for different strike patterns (rearfoot, midfoot and forefoot) using a continuum mechanics approach. A three-dimensional finite element model of the foot was employed to estimate the stress distribution in the foot at the moment of ...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255842.2018.1480760

    authors: Morales-Orcajo E,Becerro de Bengoa Vallejo R,Losa Iglesias M,Bayod J,Barbosa de Las Casas E

    更新日期:2018-05-01 00:00:00

  • Development and validation of a finite element model of a small female pedestrian.

    abstract::Pedestrians are the most vulnerable road user and represent about 23% of the road traffic deaths in the world. A finite element (FE) model corresponding to a 5th percentile female pedestrian (F05-PS) was developed by morphing the Global Human Body Models Consortium (GHBMC) 50th percentile male pedestrian (M50-PS) mode...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255842.2020.1801652

    authors: Pak W,Meng Y,Schap J,Koya B,Gayzik FS,Untaroiu CD

    更新日期:2020-12-01 00:00:00

  • Estimation of ligament strains and joint moments in the ankle during a supination sprain injury.

    abstract::This study presents the ankle ligament strains and ankle joint moments during an accidental injury event diagnosed as a grade I anterior talofibular ligament (ATaFL) sprain. A male athlete accidentally sprained his ankle while performing a cutting motion in a laboratory setting. The kinematic data were input to a thre...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255842.2013.792809

    authors: Wei F,Fong DT,Chan KM,Haut RC

    更新日期:2015-01-01 00:00:00

  • A finite element model of the face including an orthotropic skin model under in vivo tension.

    abstract::Computer models of the human face have the potential to be used as powerful tools in surgery simulation and animation development applications. While existing models accurately represent various anatomical features of the face, the representation of the skin and soft tissues is very simplified. A computer model of the...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255842.2013.820720

    authors: Flynn C,Stavness I,Lloyd J,Fels S

    更新日期:2015-01-01 00:00:00

  • The cushioning function of woodpecker's jaw apparatus during the pecking process.

    abstract::Woodpeckers can withstand a fierce impact during pecking without any brain injury. Although directly involved in the whole pecking, the role of the jaw apparatus played in the impact-resistant process of woodpeckers is still not fully clear. We employed finite element analysis, impact tests in vivo, and post-traumatic...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255842.2020.1838489

    authors: Xu P,Ni Y,Lu S,Liu S,Zhou X,Fan Y

    更新日期:2021-01-13 00:00:00

  • Effect of the degree of polar mismatching on traffic jam formation in fast axonal transport.

    abstract::This paper simulates an axon with a region of reversed microtubule (MT) polarity, and investigates how the degree of polar mismatching in this region affects the formation of organelle traps in the axon. The model is based on modified Smith-Simmons equations governing molecular-motor-assisted transport in neurons. It ...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255840903505154

    authors: Kuznetsov AV

    更新日期:2010-12-01 00:00:00

  • New method for estimating arterial pulse wave velocity at single site.

    abstract::The clinical importance of measuring local pulse wave velocity (PWV), has encouraged researchers to develop several local methods to estimate it. In this work, we proposed a new method, the sum-of-squares method [Formula: see text], that allows the estimations of PWV by using simultaneous measurements of blood pressur...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255842.2017.1423290

    authors: Abdessalem KB,Flaud P,Zobaidi S

    更新日期:2018-01-01 00:00:00

  • A human model for road safety: from geometrical acquisition to model validation with radioss.

    abstract::In order to investigate injury mechanisms, and to provide directions for road safety system improvements, the HUMOS project has lead to the development of a 3D finite element model of the human body in driving position. The model geometry was obtained from a 50th percentile adult male. It includes the description of a...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255840310001606080

    authors: Behr M,Arnoux PJ,Serre T,Bidal S,Kang HS,Thollon L,Cavallero C,Kayvantash K,Brunet C

    更新日期:2003-08-01 00:00:00

  • Determining the location of hip joint centre: application of a conchoid's shape to the acetabular cartilage surface of magnetic resonance images.

    abstract::Preoperative planning, or intraoperative navigation of hip surgery, including joint-preserving procedures such as osteotomy or joint-replacing procedures such as total arthroplasty, needs to be performed with a high degree of accuracy to ensure a successful outcome. The ability to precisely localise the hip joint rota...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255842.2010.495064

    authors: Kang MJ,Sadri H,Stern R,Magnenat-Thalmann N,Hoffmeyer P,Ji HS

    更新日期:2011-01-01 00:00:00

  • Study of age-related changes in Middle ear transfer function.

    abstract::Osteoporosis (OP) is common with advancing age. Several studies have shown a strong correlation between OP and otosclerosis. However, no studies have investigated OP of the malleus, incus or stapes in the human middle ear, its effect on middle ear transfer function. Here, we investigate whether these three ossicles de...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255842.2019.1632297

    authors: Zhou L,Shen N,Feng M,Liu H,Duan M,Huang X

    更新日期:2019-10-01 00:00:00

  • Biomechanical properties of the pelvic floor muscles of continent and incontinent women using an inverse finite element analysis.

    abstract::Pelvic disorders can be associated with changes in the biomechanical properties in the muscle, ligaments and/or connective tissue form fascia and ligaments. In this sense, the study of their mechanical behavior is important to understand the structure and function of these biological soft tissues. The aim of this stud...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255842.2017.1304542

    authors: Silva MET,Brandão S,Parente MPL,Mascarenhas T,Natal Jorge RM

    更新日期:2017-06-01 00:00:00

  • Numerical models of auto-regulation and blood flow in the cerebral circulation.

    abstract::A two-dimensional time-dependent computational fluid dynamics model of the Circle of Willis has been developed. To simulate, not only the peripheral resistance of the cerebrovascular tree but also its auto-regulation function, a new "active" boundary condition has been defined and developed using control theory to pro...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255840290032171

    authors: Ferrandez A,David T,Brown MD

    更新日期:2002-02-01 00:00:00

  • A computational prediction for the effective drug and stem cell treatment of human airway burns.

    abstract::Burns in the airway from inhaling hot gases lead to one of the most common causes of death in the United States. In order to navigate tissues with large burn areas, the velocity, temperature, and heat flux distributions throughout the human airway system are computed for the inhalation of hot air using the finite-elem...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255842.2015.1105966

    authors: Park S

    更新日期:2016-01-01 00:00:00

  • Shape optimization of a cementless hip stem for a minimum of interface stress and displacement.

    abstract::The primary stem stability is an essential factor for success of cementless hip stems. A correct choice of the stem geometry can improve the stem stability and, consequently, increase the life time of a hip implant. In this work, it is proposed a computational model for shape optimization of cementless hip stems. The ...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255840410001661637

    authors: Fernandes PR,Folgado J,Ruben RB

    更新日期:2004-02-01 00:00:00

  • Optimal mechanical design of anatomical post-systems for endodontic restoration.

    abstract::This paper analyses the mechanical behaviour of a new reinforced anatomical post-systems (RAPS) for endodontic restoration. The composite restorative material (CRM) completely fills the root canal (as do the commonly used cast metal posts) and multiple prefabricated composite posts (PCPs) are employed as reinforcement...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255840903065530

    authors: Maceri F,Martignoni M,Vairo G

    更新日期:2009-02-01 00:00:00

  • Validation performance comparison for finite element models of the human brain.

    abstract::The objective of this study was to compare the performance of six validated brain finite element (FE) models to localized brain motion validation data in five experimental configurations. Model performance was measured using the objective metric CORA (CORrelation and Analysis), where higher ratings represent better co...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255842.2017.1340462

    authors: Miller LE,Urban JE,Stitzel JD

    更新日期:2017-09-01 00:00:00