Finite element models of the thigh-buttock complex for assessing static sitting discomfort and pressure sore risk: a literature review.

Abstract:

:Being seated for long periods, while part of many leisure or occupational activities, can lead to discomfort, pain and sometimes health issues. The impact of prolonged sitting on the body has been widely studied in the literature, with a large number of human-body finite element models developed to simulate sitting and assess seat-induced discomfort or to investigate the biomechanical factors involved. Here, we review the finite element models developed to investigate sitting discomfort or risk of pressure sores. Our study examines finite element models from twenty-seven papers, seventeen dedicated to assessing seating discomfort and ten dedicated to investigating pressure ulcers caused by prolonged sitting. The models' mesh composition and material properties are found to differ widely. These models share a lack of validation and generally make little allowance for anthropometric diversity.

authors

Savonnet L,Wang X,Duprey S

doi

10.1080/10255842.2018.1466117

subject

Has Abstract

pub_date

2018-03-01 00:00:00

pages

379-388

issue

4

eissn

1025-5842

issn

1476-8259

journal_volume

21

pub_type

杂志文章,评审
  • The effects of changing bone and muscle size on limb inertial properties and limb dynamics: a computer simulation.

    abstract::The magnitude and distribution of bone and muscle mass within limbs affect limb inertial properties, maximum movement speed and the energy required to maintain submaximal movements. Musculoskeletal modeling and movement simulations were used to determine how changes in bone and muscle cross-sectional area (and thus ma...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 临床试验,杂志文章

    doi:10.1080/10255840410001727823

    authors: Dellanini L,Hawkins D,Martin B,Stover S

    更新日期:2004-06-01 00:00:00

  • A review of numerical methods for red blood cell flow simulation.

    abstract::In this review, we provide an overview of the simulation techniques employed for modelling the flow of red blood cells (RBCs) in blood plasma. The scope of this review omits the fluid modelling aspect while focusing on other key components in the RBC-plasma model such as (1) describing the RBC deformation with shell-b...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章,评审

    doi:10.1080/10255842.2013.783574

    authors: Ju M,Ye SS,Namgung B,Cho S,Low HT,Leo HL,Kim S

    更新日期:2015-01-01 00:00:00

  • A system for predicting and preventing work-related musculoskeletal disorders among dentists.

    abstract::Work-related musculoskeletal disorders (WMSDs) have become increasingly common among dentists and initiate a series of events that could result in a career ending. This study aims to construct a system for predicting and preventing WMSD among dentists. We used Bayesian network (BN) that describes the mutual relationsh...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255842.2012.672565

    authors: Thanathornwong B,Suebnukarn S,Songpaisan Y,Ouivirach K

    更新日期:2014-01-01 00:00:00

  • The effect of Knee-Ankle-Foot orthosis stiffness on the parameters of walking.

    abstract::The purpose of this simulation study was to analyze the effect of variation in Knee-Ankle-Foot-Orthosis stiffness on the joint power and the energy cost of walking. The effect of contractile tissue was simulated using linear elastic spring and viscous dampers in knee and ankle joints. Then, joint angles, ground reacti...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255842.2018.1438417

    authors: Abtahi SMA,Jamshidi N,Ghaziasgar A

    更新日期:2018-02-01 00:00:00

  • 3D finite element modeling of pelvic organ prolapse.

    abstract:OBJECTIVES:The purpose of this study is to develop a validated 3D finite element model of the pelvic floor system which can offer insights into the mechanics of anterior vaginal wall prolapse and have the ability to assess biomedical device treatment methods. The finite element results should accurately mimic the clini...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255842.2016.1186662

    authors: Yang Z,Hayes J,Krishnamurty S,Grosse IR

    更新日期:2016-12-01 00:00:00

  • Mathematical modeling of the Fontan blood circulation supported with pediatric ventricular assist device.

    abstract::The decompensated univentricular circulation is identified as one of the most challenging conditions and the application of the mechanical circulatory support (MCS) devices is proposed as therapeutic option for Fontan failure. Modelling methodologies are reported to identify the optimized types, extent and duration of...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255842.2020.1843640

    authors: Rubtsova E,Markov A,Selishchev S,Karimov JH,Telyshev D

    更新日期:2021-01-11 00:00:00

  • Numerical simulation of deformed red blood cell by utilizing neural network approach and finite element analysis.

    abstract::In order to have research on the deformation characteristics and mechanical properties of human red blood cells (RBCs), finite element models of RBC optical tweezers stretching and atomic force microscope (AFM) indentation were established. Non-linear elasticity of cell membrane was determined by using the neo-Hookean...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255842.2020.1791836

    authors: Wang Y,Sang J,Ao R,Ma Y,Fu B

    更新日期:2020-11-01 00:00:00

  • Numerical investigation of oxygen mass transfer in a helical-type artery bypass graft.

    abstract::Local oxygen lack in arterial walls (hypoxia) plays a very important role in the initiation, progression and development of intimal hyperplasia (IH) and thrombosis. Aiming to find out whether a helical-type artery bypass graft (ABG) is hypoxia beneficial, a numerical study was carried out to compare oxygen transport b...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255842.2012.702764

    authors: Zheng T,Wen J,Jiang W,Deng X,Fan Y

    更新日期:2014-04-01 00:00:00

  • Shape optimization of a cementless hip stem for a minimum of interface stress and displacement.

    abstract::The primary stem stability is an essential factor for success of cementless hip stems. A correct choice of the stem geometry can improve the stem stability and, consequently, increase the life time of a hip implant. In this work, it is proposed a computational model for shape optimization of cementless hip stems. The ...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255840410001661637

    authors: Fernandes PR,Folgado J,Ruben RB

    更新日期:2004-02-01 00:00:00

  • The effects of manufacturing tolerances and assembly force on the volumetric wear at the taper junction in modular total hip arthroplasty.

    abstract::Fretting and corrosion at the taper-head interface in total hip arthroplasty has been reported as a potential cause of early failure of the implant system. The finite element (FE) method can be used to study the mechanics at the taper junction that are difficult to assess experimentally. Taper mismatch is one of the f...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255842.2019.1627524

    authors: Bitter T,Khan I,Marriott T,Lovelady E,Verdonschot N,Janssen D

    更新日期:2019-10-01 00:00:00

  • Proposition of an outflow boundary approach for carotid artery stenosis CFD simulation.

    abstract::The purpose of this study was to propose an innovative approach of setting outlet boundary conditions for the computational fluid dynamics (CFD) simulation of human common carotid arteries (CCAs) bifurcation based on the concept of energy loss minimisation at flow bifurcation. Comparisons between this new approach and...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255842.2011.625358

    authors: Zhang Y,Furusawa T,Sia SF,Umezu M,Qian Y

    更新日期:2013-01-01 00:00:00

  • A custom musculoskeletal model for estimation of medial and lateral tibiofemoral contact forces during tasks with high knee and hip flexions.

    abstract::Most of musculoskeletal models (MSKM) estimate the tibiofemoral joint reaction load at a single point or do not support large lower-limb ranges. This study aimed to adapt a generic MSKM that allows large knee and hip flexions to compute medial and lateral tibiofemoral contact forces (TFCF) during gait and squat tasks....

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255842.2020.1757662

    authors: Bedo BLS,Catelli DS,Lamontagne M,Santiago PRP

    更新日期:2020-08-01 00:00:00

  • Localized strain measurements of the intervertebral disc annulus during biaxial tensile testing.

    abstract::Both inter-lamellar and intra-lamellar failures of the annulus have been described as potential modes of disc herniation. Attempts to characterize initial lamellar failure of the annulus have involved tensile testing of small tissue samples. The purpose of this study was to evaluate a method of measuring local surface...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255842.2014.951926

    authors: Karakolis T,Callaghan JP

    更新日期:2015-01-01 00:00:00

  • Patient-specific simulation of a stentless aortic valve implant: the impact of fibres on leaflet performance.

    abstract::In some cases of aortic valve leaflet disease, the implant of a stentless biological prosthesis represents an excellent option for aortic valve replacement (AVR). In particular, if compared with the implant of mechanical valves, it provides a more physiological haemodynamic performance and a reduced thrombogeneticity,...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255842.2012.681645

    authors: Auricchio F,Conti M,Ferrara A,Morganti S,Reali A

    更新日期:2014-01-01 00:00:00

  • Finite element and photoelastic modelling of an abdominal aortic aneurysm: a comparative study.

    abstract::Rupture prediction of abdominal aortic aneurysms (AAAs) remains a clinical challenge. Finite element analysis (FEA) may allow for improved identification for intervention timing, but the method needs further substantiation. In this study, experimental photoelastic method and finite element techniques were compared usi...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255842.2011.574618

    authors: Callanan A,Morris LG,McGloughlin TM

    更新日期:2012-01-01 00:00:00

  • An efficient algorithm for retinal blood vessel segmentation using h-maxima transform and multilevel thresholding.

    abstract::Retinal blood vessel detection and analysis play vital roles in early diagnosis and prevention of several diseases, such as hypertension, diabetes, arteriosclerosis, cardiovascular disease and stroke. This paper presents an automated algorithm for retinal blood vessel segmentation. The proposed algorithm takes advanta...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255842.2010.545949

    authors: Saleh MD,Eswaran C

    更新日期:2012-01-01 00:00:00

  • Flexural and creep properties of human jaw compact bone for FEA studies.

    abstract::The aim of this work was to improve the constitutive model of the human mandible and dentition system by taking into account the non-linear material properties of the structural boney matrix that forms the human jaw bone or mandible. Due to the specific structure of the jaw bone the time dependence of the mechanical p...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255840310001637257

    authors: Vitins V,Dobelis M,Middleton J,Limbert G,Knets I

    更新日期:2003-10-01 00:00:00

  • An assessment of swinger techniques for the playground swing oscillatory motion.

    abstract::Much attention has been devoted to how playground swing amplitudes are built up by swinger techniques, i.e. body actions. However, very little attention has been given to the requirements that such swinger techniques place on the swinger himself. The purpose of this study was to find out whether different swinger tech...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255842.2011.572280

    authors: Linge SO

    更新日期:2012-01-01 00:00:00

  • Muscle parameters estimation based on biplanar radiography.

    abstract::The evaluation of muscle and joint forces in vivo is still a challenge. Musculo-Skeletal (musculo-skeletal) models are used to compute forces based on movement analysis. Most of them are built from a scaled-generic model based on cadaver measurements, which provides a low level of personalization, or from Magnetic Res...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255842.2016.1171855

    authors: Dubois G,Rouch P,Bonneau D,Gennisson JL,Skalli W

    更新日期:2016-11-01 00:00:00

  • Finite element analysis as a tool for parametric prosthetic foot design and evaluation. Technique development in the solid ankle cushioned heel (SACH) foot.

    abstract::In this study, we developed an approach for prosthetic foot design incorporating motion analysis, mechanical testing and computer analysis. Using computer modeling and finite element analysis, a three-dimensional (3D), numerical foot model of the solid ankle cushioned heel (SACH) foot was constructed and analyzed base...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/1025584021000048974

    authors: Saunders MM,Schwentker EP,Kay DB,Bennett G,Jacobs CR,Verstraete MC,Njus GO

    更新日期:2003-02-01 00:00:00

  • Modelling organelle transport after traumatic axonal injury.

    abstract::This paper is motivated by recent experimental research (Tang-Schomer et al. 2012) on the formation of periodic varicosities in axons after traumatic brain injury (TBI). TBI leads to the formation of undulated distortions in the axons due to their dynamic deformation. These distortions result in the breakage of some m...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255842.2013.820721

    authors: Kuznetsov IA,Kuznetsov AV

    更新日期:2015-01-01 00:00:00

  • Parametric finite element analysis and closed-form solutions in orthodontics.

    abstract::The goal and clinical relevance of this work was the development of closed formulas that are correct and simple enough for a fast decision making by the orthodontist in the daily praxis. This paper performs a parametric three-dimensional finite element linear analysis on a maxillary central incisor with a root of para...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255840290032126

    authors: Provatidis CG

    更新日期:2002-04-01 00:00:00

  • Gaussian curvature analysis allows for automatic block placement in multi-block hexahedral meshing.

    abstract::Musculoskeletal finite element analysis (FEA) has been essential to research in orthopaedic biomechanics. The generation of a volumetric mesh is often the most challenging step in a FEA. Hexahedral meshing tools that are based on a multi-block approach rely on the manual placement of building blocks for their mesh gen...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255842.2010.499869

    authors: Ramme AJ,Shivanna KH,Magnotta VA,Grosland NM

    更新日期:2011-10-01 00:00:00

  • Quantification of soft tissue balance in total knee arthroplasty using finite element analysis.

    abstract::Unbalanced contact force on the tibial component has been considered a factor leading to loosening of the implant and increased wear of the bearing surface in total knee arthroplasty. Because it has been reported that good alignment cannot guarantee successful clinical outcomes, the soft tissue balance should be check...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255842.2013.765409

    authors: Oh KJ,Park WM,Kim K,Kim YH

    更新日期:2014-01-01 00:00:00

  • Physiological complexity of gait is decreased in individuals with chronic stroke.

    abstract::Complexity represents the adaptability of the biological system, therefore the assessment of complexity during tasks such as walking may be particularly useful when attempting to better understand the recovery processes after stroke. The purpose of this study was to determine whether the complexity of lower extremity ...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255842.2019.1578961

    authors: Dugan EL,Combs-Miller SA

    更新日期:2019-05-01 00:00:00

  • Numerical simulation of peristaltic flow of a biorheological fluid with shear-dependent viscosity in a curved channel.

    abstract::Peristaltic motion of a non-Newtonian Carreau fluid is analyzed in a curved channel under the long wavelength and low Reynolds number assumptions, as a simulation of digestive transport. The flow regime is shown to be governed by a dimensionless fourth-order, nonlinear, ordinary differential equation subject to no-sli...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255842.2015.1055257

    authors: Ali N,Javid K,Sajid M,Anwar Bég O

    更新日期:2016-01-01 00:00:00

  • The accuracy of active shape modelling and end-plate measurements for characterising the shape of the lumbar spine in the sagittal plane.

    abstract::The 2D shape of the lumbar spine in the sagittal plane can be determined from lordosis angles measured between the corresponding end-plates of the vertebral bodies or by using an active shape model (ASM) of the vertebral body outline. The ASM was previously shown to be a more efficient and reliable method, but its acc...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255842.2010.518962

    authors: Ali AH,Cowan AB,Gregory JS,Aspden RM,Meakin JR

    更新日期:2012-01-01 00:00:00

  • Simulation of the Seated Postural Stability of Healthy and Spinal Cord-Injured Subjects Using Optimal Feedback Control Methods.

    abstract::A two-dimensional, biomechanical computer model was developed, using the software package Working Model(TM), to simulate the postural control of seated individuals. Both able-bodied and spinal cord-injured subjects were represented. The model incorporated active control of the upper body through full-state feedback. S...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255840008915256

    authors: Kamper D,Barin K,Parnianpour M,Hemami H,Weed H

    更新日期:2000-01-01 00:00:00

  • Solute transport in cartilage undergoing cyclic deformation.

    abstract::There are no blood vessels in cartilage to transport nutrients and growth factors to chondrocytes dispersed throughout the cartilage matrix. Insulin-like growth factor-I (IGF-I) is a large molecule with an important role in cartilage growth and metabolism, however, it first must reach the chondrocytes to exert its eff...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255840701309163

    authors: Gardiner B,Smith D,Pivonka P,Grodzinsky A,Frank E,Zhang L

    更新日期:2007-08-01 00:00:00

  • Finite element modelling of human auditory periphery including a feed-forward amplification of the cochlea.

    abstract::A three-dimensional finite element model is developed for the simulation of the sound transmission through the human auditory periphery consisting of the external ear canal, middle ear and cochlea. The cochlea is modelled as a straight duct divided into two fluid-filled scalae by the basilar membrane (BM) having an or...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255842.2012.737458

    authors: Wang X,Wang L,Zhou J,Hu Y

    更新日期:2014-08-01 00:00:00