Comparing parametric solid modelling/reconfiguration, global shape modelling and free-form deformation for the generation of 3D digital models of femurs from X-ray images.

Abstract:

:At present, computer assisted surgery systems help orthopaedic surgeons both plan and perform surgical procedures. To enable these systems to function, it is crucial to have at one's disposal 3D models of anatomical structures, surgical tools and prostheses (if required). This paper analyses and compares three methods for generating 3D digital models of anatomical structures starting from X-ray images: parametric solid modelling/reconfiguration, global shape modelling and free-form deformation. Seven experiences involving the generation of a femur model were conducted by software developers and different skilled users. These experiences are described in detail and compared at different stages and from different points of view.

authors

Filippi S,Motyl B,Bandera C

doi

10.1080/10255840903077329

subject

Has Abstract

pub_date

2009-02-01 00:00:00

pages

101-8

issue

1

eissn

1025-5842

issn

1476-8259

pii

795251146

journal_volume

12

pub_type

杂志文章
  • A Finite Element Approach for Skeletal Muscle using a Distributed Moment Model of Contraction.

    abstract::The present paper describes a geometrically and physically nonlinear continuum model to study the mechanical behaviour of passive and active skeletal muscle. The contraction is described with a Huxley type model. A Distributed Moments approach is used to convert the Huxley partial differential equation in a set of ord...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255840008915267

    authors: Gielen AW,Oomens CW,Bovendeerd PH,Arts T,Janssen JD

    更新日期:2000-01-01 00:00:00

  • A reliability measure of protein-protein interactions and a reliability measure-based search engine.

    abstract::Many methods developed for estimating the reliability of protein-protein interactions are based on the topology of protein-protein interaction networks. This paper describes a new reliability measure for protein-protein interactions, which does not rely on the topology of protein interaction networks, but expresses bi...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255842.2010.494039

    authors: Park B,Han K

    更新日期:2010-02-01 00:00:00

  • Mathematical modeling of the Fontan blood circulation supported with pediatric ventricular assist device.

    abstract::The decompensated univentricular circulation is identified as one of the most challenging conditions and the application of the mechanical circulatory support (MCS) devices is proposed as therapeutic option for Fontan failure. Modelling methodologies are reported to identify the optimized types, extent and duration of...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255842.2020.1843640

    authors: Rubtsova E,Markov A,Selishchev S,Karimov JH,Telyshev D

    更新日期:2021-01-11 00:00:00

  • A joint coordinate system proposal for the study of the trapeziometacarpal joint kinematics.

    abstract::The International Society of Biomechanics (ISB) has recommended a standardisation for the motion reporting of almost all human joints. This study proposes an adaptation for the trapeziometacarpal joint. The definition of the segment coordinate system of both trapezium and first metacarpal is based on functional anatom...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255840802459404

    authors: Cheze L,Dumas R,Comtet JJ,Rumelhart C,Fayet M

    更新日期:2009-06-01 00:00:00

  • Numerical studies of the influence of various geometrical features of a multispiked connecting scaffold prototype on mechanical stresses in peri-implant bone.

    abstract::The multispiked connecting scaffold (MSC-scaffold) prototype is an essential innovation in the fixation of components of resurfacing arthroplasty (RA) endoprostheses, providing their entirely non-cemented and bone-tissue-preserving fixation in peri-articular bone. An FE study is proposed to evaluate the influence of g...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255842.2018.1480759

    authors: Uklejewski R,Winiecki M,Patalas A,Rogala P

    更新日期:2018-07-01 00:00:00

  • Parametric finite element analysis and closed-form solutions in orthodontics.

    abstract::The goal and clinical relevance of this work was the development of closed formulas that are correct and simple enough for a fast decision making by the orthodontist in the daily praxis. This paper performs a parametric three-dimensional finite element linear analysis on a maxillary central incisor with a root of para...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255840290032126

    authors: Provatidis CG

    更新日期:2002-04-01 00:00:00

  • Fibre Orientation in Human Fetal Heart and Ventricular Mechanics : A Small Perturbation Analysis.

    abstract::The study of the topological organisation of myocardial cells is a basic requirement for understanding the mechanical design of the normal and pathological heart. Anatomical observations show that cardiac muscle tissue has a highly specialized architecture. We have made new quantitative measurements of fibre orientati...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255849908907980

    authors: Ohayon J,Usson Y,Jouk PS,Cai H

    更新日期:1999-01-01 00:00:00

  • New head models extracted from thermal infrared (IR) images for dosimetry computations.

    abstract::In electromagnetic dosimetry, anatomical human models are commonly obtained by segmentation of magnetic resonance imaging or computed tomography scans. In this paper, a human head model extracted from thermal infrared images is examined in terms of its applicability to specific absorption rate (SAR) calculations. Sinc...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255842.2011.563738

    authors: Gasmelseed A

    更新日期:2011-07-01 00:00:00

  • Numerical simulation of non-Newtonian blood flow dynamics in human thoracic aorta.

    abstract::Three non-Newtonian blood viscosity models plus the Newtonian one are analysed for a patient-specific thoracic aorta anatomical model under steady-state flow conditions via wall shear stress (WSS) distribution, non-Newtonian importance factors, blood viscosity and shear rate. All blood viscosity models yield a consist...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255842.2014.887698

    authors: Caballero AD,Laín S

    更新日期:2015-08-01 00:00:00

  • New method for estimating arterial pulse wave velocity at single site.

    abstract::The clinical importance of measuring local pulse wave velocity (PWV), has encouraged researchers to develop several local methods to estimate it. In this work, we proposed a new method, the sum-of-squares method [Formula: see text], that allows the estimations of PWV by using simultaneous measurements of blood pressur...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255842.2017.1423290

    authors: Abdessalem KB,Flaud P,Zobaidi S

    更新日期:2018-01-01 00:00:00

  • A human model for road safety: from geometrical acquisition to model validation with radioss.

    abstract::In order to investigate injury mechanisms, and to provide directions for road safety system improvements, the HUMOS project has lead to the development of a 3D finite element model of the human body in driving position. The model geometry was obtained from a 50th percentile adult male. It includes the description of a...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255840310001606080

    authors: Behr M,Arnoux PJ,Serre T,Bidal S,Kang HS,Thollon L,Cavallero C,Kayvantash K,Brunet C

    更新日期:2003-08-01 00:00:00

  • Muscle parameters estimation based on biplanar radiography.

    abstract::The evaluation of muscle and joint forces in vivo is still a challenge. Musculo-Skeletal (musculo-skeletal) models are used to compute forces based on movement analysis. Most of them are built from a scaled-generic model based on cadaver measurements, which provides a low level of personalization, or from Magnetic Res...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255842.2016.1171855

    authors: Dubois G,Rouch P,Bonneau D,Gennisson JL,Skalli W

    更新日期:2016-11-01 00:00:00

  • Cluster analysis of pressure pain threshold maps from the trapezius muscle.

    abstract::The aim of this study was to investigate and present a new mapping method to describe muscle pain sensitivity based on the assessment of pressure pain threshold (PPT) over the trapezius muscle. PPT data were recorded from 36 points in 20 healthy males using a standardised grid. Points were clustered using the K-means ...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255840903446979

    authors: Binderup AT,Arendt-Nielsen L,Madeleine P

    更新日期:2010-12-01 00:00:00

  • Implementation and validation of probabilistic models of the anterior longitudinal ligament and posterior longitudinal ligament of the cervical spine.

    abstract::The objective of this investigation was to develop probabilistic finite element (FE) models of the anterior longitudinal ligament (ALL) and posterior longitudinal ligament (PLL) of the cervical spine that incorporate the natural variability of biological specimens. In addition to the model development, a rigorous vali...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255842.2012.726353

    authors: Francis WL,Eliason TD,Thacker BH,Paskoff GR,Shender BS,Nicolella DP

    更新日期:2014-01-01 00:00:00

  • The non-linear response of a muscle in transverse compression: assessment of geometry influence using a finite element model.

    abstract::Most recent finite element models that represent muscles are generic or subject-specific models that use complex, constitutive laws. Identification of the parameters of such complex, constitutive laws could be an important limit for subject-specific approaches. The aim of this study was to assess the possibility of mo...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255842.2011.564162

    authors: Gras LL,Mitton D,Crevier-Denoix N,Laporte S

    更新日期:2012-01-01 00:00:00

  • The accuracy of active shape modelling and end-plate measurements for characterising the shape of the lumbar spine in the sagittal plane.

    abstract::The 2D shape of the lumbar spine in the sagittal plane can be determined from lordosis angles measured between the corresponding end-plates of the vertebral bodies or by using an active shape model (ASM) of the vertebral body outline. The ASM was previously shown to be a more efficient and reliable method, but its acc...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255842.2010.518962

    authors: Ali AH,Cowan AB,Gregory JS,Aspden RM,Meakin JR

    更新日期:2012-01-01 00:00:00

  • Hexahedral meshing of subject-specific anatomic structures using mapped building blocks.

    abstract::To extend the use of computational techniques like finite element analysis to clinical settings, it would be beneficial to have the ability to generate a unique model for every subject quickly and efficiently. This work is an extension of two previously developed mapped meshing tools that utilised force and displaceme...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255842.2011.629614

    authors: Kallemeyn NA,Natarajan A,Magnotta VA,Grosland NM

    更新日期:2013-01-01 00:00:00

  • Multi-component modelling of human brain tissue: a contribution to the constitutive and computational description of deformation, flow and diffusion processes with application to the invasive drug-delivery problem.

    abstract::Human brain tissue is complex and multi-component in nature. It consists of an anisotropic hyperelastic solid material composed of tissue cells and blood vessel walls. Brain tissue is permeated by two viscous pore liquids, the interstitial fluid and the blood. Both liquids are mobile within the tissue and exhibit a si...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255842.2013.853754

    authors: Ehlers W,Wagner A

    更新日期:2015-01-01 00:00:00

  • An integrated diabetic index using heart rate variability signal features for diagnosis of diabetes.

    abstract::Electrocardiogram (ECG) signals are difficult to interpret, and clinicians must undertake a long training process to learn to diagnose diabetes from subtle abnormalities in these signals. To facilitate these diagnoses, we have developed a technique based on the heart rate variability signal obtained from ECG signals. ...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255842.2011.616945

    authors: Acharya UR,Faust O,Sree SV,Ghista DN,Dua S,Joseph P,Ahamed VI,Janarthanan N,Tamura T

    更新日期:2013-01-01 00:00:00

  • Further Roles of Geometry and Properties in the Mechanics of Saccular Aneurysms.

    abstract::Rupture of intracranial saccular aneurysms continues to result in significant morbidity and mortality. Although it has long been thought that biomechanical factors play key roles in the genesis, growth, and rupture of these lesions, few analysis have employed realistic descriptions of the geometries and material prope...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/01495739708936698

    authors: Shah AD,Harris JL,Kyriacou SK,Humphrey JD

    更新日期:1998-01-01 00:00:00

  • The effects of manufacturing tolerances and assembly force on the volumetric wear at the taper junction in modular total hip arthroplasty.

    abstract::Fretting and corrosion at the taper-head interface in total hip arthroplasty has been reported as a potential cause of early failure of the implant system. The finite element (FE) method can be used to study the mechanics at the taper junction that are difficult to assess experimentally. Taper mismatch is one of the f...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255842.2019.1627524

    authors: Bitter T,Khan I,Marriott T,Lovelady E,Verdonschot N,Janssen D

    更新日期:2019-10-01 00:00:00

  • Influence of inlet boundary conditions on the local haemodynamics of intracranial aneurysms.

    abstract::Haemodynamics is believed to play an important role in the initiation, growth and rupture of intracranial aneurysms. In this context, computational haemodynamics has been extensively used in an effort to establish correlations between flow variables and clinical outcome. It is common practice in the application of Dir...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255840802654335

    authors: Marzo A,Singh P,Reymond P,Stergiopulos N,Patel U,Hose R

    更新日期:2009-08-01 00:00:00

  • A generic musculoskeletal model of the juvenile lower limb for biomechanical analyses of gait.

    abstract::The aim of this study was to develop a generic musculoskeletal model of a healthy 10-year-old child and examine the effects of geometric scaling on the calculated values of lower-limb muscle forces during gait. Subject-specific musculoskeletal models of five healthy children were developed from in vivo MRI data, and t...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255842.2020.1817405

    authors: Hainisch R,Kranzl A,Lin YC,Pandy MG,Gfoehler M

    更新日期:2020-09-17 00:00:00

  • Influence of mastication and edentulism on mandibular bone density.

    abstract::The aim of this study was to demonstrate that external loading due to daily activities, including mastication, speech and involuntary open-close cycles of the jaw contributes to the internal architecture of the mandible. A bone remodelling algorithm that regulates the bone density as a function of stress and loading c...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255842.2013.792916

    authors: Chou HY,Satpute D,Müftü A,Mukundan S,Müftü S

    更新日期:2015-01-01 00:00:00

  • Numerical simulation of two-phase non-Newtonian blood flow with fluid-structure interaction in aortic dissection.

    abstract::The behavior of blood cells and vessel compliance significantly influence hemodynamic parameters, which are closely related to the development of aortic dissection. Here the two-phase non-Newtonian model and the fluid-structure interaction (FSI) method are coupled to simulate blood flow in a patient-specific dissected...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255842.2019.1577398

    authors: Qiao Y,Zeng Y,Ding Y,Fan J,Luo K,Zhu T

    更新日期:2019-05-01 00:00:00

  • Biomechanical analysis of the anterior cervical fusion.

    abstract::This paper presents a biomechanical analysis of the cervical C5-C6 functional spine unit before and after the anterior cervical discectomy and fusion. The aim of this work is to study the influence of the medical procedure and its instrumentation on range of motion and stress distribution. First, a three-dimensional f...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255842.2011.597351

    authors: Fernandes PC,Fernandes PR,Folgado JO,Levy Melancia J

    更新日期:2012-01-01 00:00:00

  • Effectiveness of pedicle screw inclusion at the fracture level in short-segment fixation constructs for the treatment of thoracolumbar burst fractures: a computational biomechanics analysis.

    abstract::When treating thoracolumbar burst fractures (BF), short-segment posterior fixation (SSPF) represents a less invasive alternative to the traditional long-segment posterior fixation (LSPF) approach. However, hardware failure and loss of sagittal alignment have been reported in patients treated with SSPF. Including pedic...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255842.2017.1366995

    authors: Elmasry S,Asfour S,Travascio F

    更新日期:2017-10-01 00:00:00

  • In vivo measurement of surface skin strain during human gait to improve the design of rehabilitation devices.

    abstract::When designing any rehabilitation, sportswear or exoskeleton device the mechanical behaviour of the body segment must be known, specifically the skin, because an excessive tissue strain may lead to ulceration and bedsores. To date, it is not known if the kinematic variability between subjects have an effect on the ski...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255842.2019.1655549

    authors: Barrios-Muriel J,Romero Sánchez F,Alonso Sánchez FJ,Rodríguez Salgado D

    更新日期:2019-11-01 00:00:00

  • Interaction of microstructure and microcrack growth in cortical bone: a finite element study.

    abstract::Microstructural features including osteons and cement lines are considered to play an important role in determining the crack growth behaviour in cortical bone. This study aims to develop a computational mechanics approach to evaluate microscale fracture mechanisms in bone. In this study, finite element models based o...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255842.2011.607444

    authors: Mischinski S,Ural A

    更新日期:2013-01-01 00:00:00

  • The sensitivity of nonlinear computational models of trabecular bone to tissue level constitutive model.

    abstract::Microarchitectural finite element models have become a key tool in the analysis of trabecular bone. Robust, accurate, and validated constitutive models would enhance confidence in predictive applications of these models and in their usefulness as accurate assays of tissue properties. Human trabecular bone specimens fr...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255842.2015.1041022

    authors: Baumann AP,Shi X,Roeder RK,Niebur GL

    更新日期:2016-01-01 00:00:00