A fast response and gamma-insensitive neutron detector based on parallel-plate avalanche counter.

Abstract:

:The use of the parallel-plate avalanche counter for slow-neutron counting is described. The choice of a suitable neutron converter is discussed on the basis of Monte Carlo simulation, and some experimental results are shown. Excellent gamma-insensitivity, high rate capability, possibility of construction in large sensitive area and low production cost are among the promising features of this neutron detector.

journal_name

Radiat Prot Dosimetry

authors

Nakhostin M,Baba M,Itoga T,Oishi T,Unno Y,Kamada S,Okuji T

doi

10.1093/rpd/ncm462

subject

Has Abstract

pub_date

2008-01-01 00:00:00

pages

426-30

issue

4

eissn

0144-8420

issn

1742-3406

pii

ncm462

journal_volume

129

pub_type

杂志文章,评审
  • Numerical solution of the transport equation describing the radon transport from subsurface soil to buildings.

    abstract::A theoretical evaluation of the properties and processes affecting the radon transport from subsurface soil into buildings is presented in this work. The solution of the relevant transport equation is obtained using the explicit finite difference method (EFDM). Results are compared with analytical steady-state solutio...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncr397

    authors: Savović S,Djordjevich A,Ristić G

    更新日期:2012-06-01 00:00:00

  • Declassification of radioactive liquid wastes generated in radio immune assay [corrected] (RIA) laboratories.

    abstract::Radioactive liquid wastes of low-medium activity level are generated in radio immune assay (RIA) laboratories, which are also potentially infectious because of the pathogens from patient blood. The most common way of managing these wastes consists of a temporal storage, for partial radioactivity decay, followed by man...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci076

    authors: Sancho M,Arnal JM,Villaescusa JI,Campayo JM,Verdú G

    更新日期:2005-01-01 00:00:00

  • The influence of novel CT reconstruction technique and ECG-gated technique on image quality and patient dose of cardiac computed tomography.

    abstract::The aim of the present study was to compare image quality and patient dose in cardiac computed tomography angiography (CTA) in terms of volume computed tomography dose index (CTDI vol), dose length product (DLP) and effective dose, when changing from filtered back projection (FBP) to adaptive iterative dose reduction ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncv114

    authors: Dyakov I,Stoinova V,Groudeva V,Vassileva J

    更新日期:2015-07-01 00:00:00

  • EXPOSURE ASSESSMENT OF PORTABLE WIRELESS DEVICES ABOVE 6 GHz.

    abstract::The emerging 5 G wireless devices working at frequencies above 6 GHz are expected to have antenna arrays formed by dipoles, slots, patches or their combination. At lower frequencies, the accepted criteria for exposure compliance is stated in terms of specific absorption rate. IEEE and ICNIRP are adopting epithelial or...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncy177

    authors: Carrasco E,Colombi D,Foster KR,Ziskin M,Balzano Q

    更新日期:2019-06-01 00:00:00

  • Development of a voxel phantom of Japanese adult male in upright posture.

    abstract::A Japanese voxel phantom in upright posture, JM2, has been developed on the basis of CT images of a healthy Japanese adult male. Body characteristics of JM2 were compared with those of the supine voxel phantom, JM, previously developed using CT images of the same person. Differences were found in the shapes of the spi...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm272

    authors: Sato K,Noguchi H,Endo A,Emoto Y,Koga S,Saito K

    更新日期:2007-01-01 00:00:00

  • Determination of the minimum measurement time for estimating long-term mean radon concentration.

    abstract::Radon measurements, as do any measurements, include errors in their readings. The relative values of such errors depend principally on the measurement methods used, the radon concentration to be measured and the duration of the measurements. Typical exposure times for radon surveys using passive detectors [nuclear tra...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncs217

    authors: Janik M,Łoskiewicz J,Tokonami S,Kozak K,Mazur J,Ishikawa T

    更新日期:2012-11-01 00:00:00

  • The present ICRP protection quantitites are seriously flawed. Opposing the proposition.

    abstract::Our debaters have agreed to defend positions that appear to be diametrically opposed; nevertheless, they have acknowledged some common ground. Although it was not explicitly stated, they would no doubt agree that workers and the public are adequately protected by our present system of radiation regulations. Our debate...

    journal_title:Radiation protection dosimetry

    pub_type: 评论,杂志文章

    doi:

    authors: Edwards AA

    更新日期:2003-01-01 00:00:00

  • Individual monitoring in mixed neutron/photon fields using a single silicon detector.

    abstract::A device based on a single silicon detector of special converter/detector design optimised for the determination of the neutron dose equivalent is also used for the determination of the photon dose equivalent. While the neutron dose is determined on the basis of signals corresponding to energy depositions above 1.5 Me...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a005962

    authors: Luszik-Bhadra M

    更新日期:2002-01-01 00:00:00

  • Defect complexes in Re3+-doped magnesium sulphate phosphors.

    abstract::A series of magnesium sulphate phosphors MgSO4:RE3+,X ( RE = Dy, Tm, Eu and X = P, Mn) have been prepared and studied. Based on the experimental results of thermoluminescence (TL) emission spectra and dose responses studies, it is proposed that in these phosphors large defect complexes are formed, which include intrin...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci680

    authors: Luo DL,Tang Q,Zhang CX

    更新日期:2006-01-01 00:00:00

  • Uranium isotopes in public drinking water and dose assessment for man in Poland.

    abstract::238U, 234U and 235U were determined in tap water from municipal water pipes that drew their supply from surface water or ground water in various locations in Poland. Average activity concentrations of 238U, 234U and 235U in tap water from surface water were 9.6 +/- 7.1, 12.8 +/- 9.7 and 0.41 +/- 0.31 Bq m(-3), respect...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch425

    authors: Pietrzak-Flis Z,Kaminska I,Chrzanowski E

    更新日期:2005-01-01 00:00:00

  • The response of a bonner sphere spectrometer to charged hadrons.

    abstract::Bonner sphere spectrometers (BSSs) are employed in neutron spectrometry and dosimetry since many years. Recent developments have seen the addition to a conventional BSS of one or more detectors (moderator plus thermal neutron counter) specifically designed to improve the overall response of the spectrometer to neutron...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch187

    authors: Agosteo S,Dimovasili E,Fassò A,Silari M

    更新日期:2004-01-01 00:00:00

  • Effective dose and breast dose reduction in paediatric scoliosis X-ray radiography by an optimal positioning.

    abstract::The purpose of this article is to recommend positioning to reduce the effective and breast-absorbed-doses in paediatric scoliosis radiography. Effective and breast-absorbed-doses were evaluated using Monte Carlo simulations. Head directed towards the anode (HTA) positioning rather than head directed towards the cathod...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章,多中心研究

    doi:10.1093/rpd/nct038

    authors: Ben-Shlomo A,Bartal G,Shabat S,Mosseri M

    更新日期:2013-01-01 00:00:00

  • Development of a nanotechnology based low-LET multi-microbeam array single cell irradiation system.

    abstract::A novel single cell irradiation system using carbon nanotube (CNT) based field emission technology is proposed. The system can produce electron microbeam at a large range of pulsation frequencies and dose rates with energy between 20 and 60 keV. Different from any existing single beam microbeam device, the CNT-based s...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncl508

    authors: Chang S,Zhang J,Bordelon D,Schreiber E,Cox A,Zhou O

    更新日期:2006-01-01 00:00:00

  • Relative radiological risks derived from different TENORM wastes in Malaysia.

    abstract::In Malaysia technologically enhanced naturally occurring radioactive materials (TENORM) wastes are mainly the product of the oil and gas industry and mineral processing. Among these TENORM wastes are tin tailing, tin slag, gypsum and oil sludge. Mineral processing and oil and gas industries produce large volume of TEN...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq577

    authors: Ismail B,Teng IL,Muhammad Samudi Y

    更新日期:2011-11-01 00:00:00

  • Tissue-equivalent TL sheet dosimetry system for X- and gamma-ray dose mapping.

    abstract::To measure dose distribution for X- and gamma rays simply and accurately, a tissue-equivalent thermoluminescent (TL) sheet-type dosemeter and reader system were developed. The TL sheet is composed of LiF:Mg,Cu,P and ETFE polymer, and the thickness is 0.2 mm. For the TL reading, a square heating plate, 20 cm on each si...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci571

    authors: Nariyama N,Konnai A,Ohnishi S,Odano N,Yamaji A,Ozasa N,Ishikawa Y

    更新日期:2006-01-01 00:00:00

  • Air kerma to HP(3) conversion coefficients for photons from 10 keV to 10 MeV, calculated in a cylindrical phantom.

    abstract::In the framework of the ORAMED project (Optimization of RAdiation protection for MEDical staff), funded by the European Union Seventh Framework Programme, different studies were aimed at improving the quality of radiation protection in interventional radiology and nuclear medicine. The main results of the project were...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncs269

    authors: Gualdrini G,Bordy JM,Daures J,Fantuzzi E,Ferrari P,Mariotti F,Vanhavere F

    更新日期:2013-05-01 00:00:00

  • Energy responses of the LiF series TL pellets to high-energy photons in the energy range from 1.25 to 21 MV.

    abstract::The energy responses for the KLT-300(LiF:Mg,Cu,Na,Si, Korea), GR-200(LiF:Mg,Cu,P, China) and MCP-N(LiF:Mg,Cu,P, Poland) thermoluminescence(TL) pellets were studied for a photon radiation with energies from 1.25 MeV(60Co) to 21 MV (Microtron) to verify the usefulness of the calibration for the radiotherapy beams. The I...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci627

    authors: Kim JL,Lee JI,Ji YH,Kim BH,Kim JS,Chang SY

    更新日期:2006-01-01 00:00:00

  • Assessment of natural radioactivity and the associated hazards in Iranian cement.

    abstract::This paper presents the finding of a study undertaken to determine natural radioactivity and associated hazards in local types of cement in Iran. A total of 42 samples were collected from various manufacturers and suppliers and analysed using a shielded HPGe gamma-ray spectrometer. The specific activities of 232Th, 22...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncl549

    authors: Fathivand AA,Amidi J

    更新日期:2007-01-01 00:00:00

  • On a model-based approach to radiation protection.

    abstract::There is a preoccupation with linearity and absorbed dose as the basic quantifiers of radiation hazard. An alternative is the fluence approach, whereby radiation hazard may be evaluated, at least in principle, via an appropriate action cross section. In order to compare these approaches, it may be useful to discuss th...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006828

    authors: Waligórski MP

    更新日期:2002-01-01 00:00:00

  • Experiences in methods to involve key players in planning protective actions in the case of a nuclear accident.

    abstract::A widely used method in the planning of protective actions is to establish a stakeholder network to generate a comprehensive set of generic protective actions. The aim is to increase competence and build links for communication and coordination. The approach of this work was to systematically evaluate protective actio...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch258

    authors: Sinkko K,Hämäläinen RP,Hänninen R

    更新日期:2004-01-01 00:00:00

  • The genetics of radiation-induced osteosarcoma.

    abstract::Individual genetic variation can influence susceptibility to the carcinogenic effects of many environmental carcinogens. In radiation-exposed populations those individuals with a greater genetically determined susceptibility would be at greater risk of developing cancer. To include this modification of risk into radia...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006778

    authors: Rosemann M,Kuosaite V,Nathrath M,Atkinson MJ

    更新日期:2002-01-01 00:00:00

  • Evaluating the performance of the Harshaw™ DXTRAD LiF:Mg,Cu,P finger ring with two different thickness filters.

    abstract::Amongst the dosemeters offered by the Health Protection Agency (HPA) Personal Dosimetry Service are finger rings, which use the Harshaw™ DXTRAD element. This paper describes restricted-type testing carried out by HPA on the previously untried combination of the LiF:Mg,Cu,P material and a thicker filter (42 mg cm(-2))....

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq564

    authors: Baker ST,Roberts GH,Gilvin PJ

    更新日期:2011-03-01 00:00:00

  • Simulation of DNA damage after proton and low LET irradiation.

    abstract::A module for proton track structure simulation in liquid water was implemented in the biophysical model PARTRAC. Simulated tracks of energy deposition events from the radiation under investigation were superimposed on a higher-order DNA target model describing the whole genome inside a human cell. The parameters contr...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006848

    authors: Friedland W,Bernhardt P,Jacob P,Paretzke HG,Dingfelder M

    更新日期:2002-01-01 00:00:00

  • Mechanistic modelling of genetic and epigenetic events in radiation carcinogenesis.

    abstract::Methodological problems arise on the way of radiation carcinogenesis modelling with the incorporation of radiobiological and cancer biology mechanistic data. The results of biophysical modelling of different endpoints [DNA DSB induction, repair, chromosome aberrations (CA) and cell proliferation] are presented and app...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncl463

    authors: Andreev SG,Eidelman YA,Salnikov IV,Khvostunov IK

    更新日期:2006-01-01 00:00:00

  • AUTOMATIC BRAIN DOSE ESTIMATION IN COMPUTED TOMOGRAPHY USING PATIENT DICOM IMAGES.

    abstract::This study aims to develop an Automatic Brain Dose Estimation (ABDE) methodology for head computed tomography examinations. The ABDE is to be applied first to an anthropomorphic Alderson phantom to obtain a Correction factor (Cf) between the ABDE and the direct absorbed brain dose using dosemeters positioned within th...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncaa006

    authors: Gharbi S,Labidi S,Mars M

    更新日期:2020-07-02 00:00:00

  • Internal dose assessment in radiation accidents.

    abstract::Although numerous models have been developed for occupational and medical internal dosimetry, they may not be applicable to an accident situation. Published dose coefficients relate effective dose to intake, but if acute deterministic effects are possible, effective dose is not a useful parameter. Consequently, dose r...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006250

    authors: Toohey RE

    更新日期:2003-01-01 00:00:00

  • Panel discussion: Do non-targeted effects impact the relation between microdosimetry and risk?

    abstract::An invited panel discussed with the participants of the Symposium their views on the impact of non-targeted effects on the relationship between microdosimetry and risk. The discussion was wide ranging and lively, with divergences of opinion. At one end was the view that understanding microscopic features and distribut...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq393

    authors: Goodhead DT

    更新日期:2011-02-01 00:00:00

  • Dose and dose rate effectiveness of space radiation.

    abstract::Dose and dose rate effectiveness factors (DDREF), in conjunction with other weighting factors, are commonly used to scale atomic bomb survivor data in order to establish limits for occupational radiation exposure, including radiation exposure in space. We use some well-known facts about the microscopic pattern of ener...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncl464

    authors: Schimmerling W,Cucinotta FA

    更新日期:2006-01-01 00:00:00

  • Radical distributions in ammonium tartrate single crystals exposed to photon and neutron beams.

    abstract::The radiation therapy carried out by means of heavy charged particles (such as carbon ions) and neutrons is rapidly becoming widespread worldwide. The success of these radiation therapies relies on the high density of energy released by these particles or by secondary particles produced after primary interaction with ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncu033

    authors: Marrale M,Longo A,Barbon A,Brustolon M,Brai M

    更新日期:2014-10-01 00:00:00

  • Modelling of composite neutron scintillators.

    abstract::Composite neutron scintillators consisting of neutron-insensitive fluorescent dopant particles (e.g. ZnS:Ag) embedded in a matrix material containing isotopes with high neutron cross sections that emit energetic charged particles (e.g. 6Li) are a popular method for neutron detection in a variety of applications. The s...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci121

    authors: Stephan AC,Dai S,Wallace SA,Miller LF

    更新日期:2005-01-01 00:00:00