Evaluating the performance of the Harshaw™ DXTRAD LiF:Mg,Cu,P finger ring with two different thickness filters.

Abstract:

:Amongst the dosemeters offered by the Health Protection Agency (HPA) Personal Dosimetry Service are finger rings, which use the Harshaw™ DXTRAD element. This paper describes restricted-type testing carried out by HPA on the previously untried combination of the LiF:Mg,Cu,P material and a thicker filter (42 mg cm(-2)). The tests were based on ISO 12794 [International Organization for Standardization. ISO 12794:2000 nuclear energy--radiation protection--individual thermoluminescence dosemeters for the extremities and eyes. ISO (2000)] and included energy and angle dependence of response for photons. The conclusion was, for photon dosimetry applications the thicker filter is acceptable for use in the HPA service.

journal_name

Radiat Prot Dosimetry

authors

Baker ST,Roberts GH,Gilvin PJ

doi

10.1093/rpd/ncq564

subject

Has Abstract

pub_date

2011-03-01 00:00:00

pages

243-5

issue

1-4

eissn

0144-8420

issn

1742-3406

pii

ncq564

journal_volume

144

pub_type

杂志文章
  • A high-sensitivity method for the measurement of 222Rn based on liquid scintillation counting of polycarbonate powder.

    abstract::This work describes a technique for the measurement of 222Rn by absorption in polycarbonate (PC) powder and liquid scintillation counting (LSC). The work is an improvement of the recently proposed method for 222Rn measurements by LSC of exposed PC grains. It is demonstrated that the use of PC powder as a 222Rn sampler...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncu075

    authors: Mitev K,Georgiev S,Pressyanov D,Dimitrova I,Zhivkova V,Boshkova T

    更新日期:2014-07-01 00:00:00

  • COMPARISON OF MCNP AND VISIPLAN DOSE-FIELD CALCULATIONS FOR MULTILAYER SHIELDING.

    abstract::An important factor in calculation of quantities describing the radiation situation is the selection of a calculation code. In this article, the radiation situation for selected geometries with multilayer shields was judged. Calculations were carried out using deterministic code VISIPLAN and stochastic code MCNP5. Int...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncz224

    authors: Bednár D,Lištjak M,Slimák A,Nečas V

    更新日期:2019-12-31 00:00:00

  • Variations of soil radon concentrations along Chite fault in Aizawl district, Mizoram, India.

    abstract::The present study concerns measurements of radon emissions from soil carried out during March to July 2013 at Chite fault in Aizawl district, Mizoram, India. In this study, continuous radon monitoring in soil was done by using LR-115 type II nuclear track detector (Kodak-Pathe, France make), and the exposed films were...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncu221

    authors: Singh S,Jaishi H,Tiwari RP,Tiwari RC

    更新日期:2014-11-01 00:00:00

  • Correlation of phase transition with the change in TL characteristics in CaSO4:Dy phosphor--effect of thermal treatment.

    abstract::The study is aimed at optimising the glow curve structure of CaSO4:Dy phosphor for dosimetric purpose and also to understand the observed changes owing to thermal treatment in the thermoluminescence (TL) sensitivity and glow curve structure. The reversible changes in the intensities of the lower temperature satellite ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci561

    authors: Bakshi AK,Pradhan AS,Tyagi AK,Kher RK,Bhatt BC

    更新日期:2006-01-01 00:00:00

  • Broadband Direct UVA irradiance measurement for clear skies evaluated using a smartphone.

    abstract::UVA wavelengths (320-400 nm) have been implicated in recent studies to contribute to melanoma induction and skin photoaging in humans and damage to plants. The use of smartphones in UVA observations is a way to supplement measurements made by traditional radiometric and spectroradiometric technology. Although the smar...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncu344

    authors: Igoe D,Parisi AV

    更新日期:2015-12-01 00:00:00

  • Comparative analysis between radiation doses obtained by EPR dosimetry using tooth enamel and established analytical methods for the population of radioactively contaminated territories.

    abstract::A comparative analysis of radiation doses determined by tooth enamel electron paramagnetic resonance (EPR) spectroscopy and by an acknowledged analytical method is performed for individual doses and for average doses in population of some settlements of the Bryansk region (Russia), which have been contaminated after t...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncu132

    authors: Ivannikov AI,Skvortsov VG,Stepanenko VF,Zhumadilov KSh

    更新日期:2014-06-01 00:00:00

  • PRUDENCE AND CONSERVATISM IN RADIATION PROTECTION: A CASE STUDY.

    abstract::Prudence is a cornerstone of radiation protection philosophy. However, whilst the concept is clearly valid at the level of principle, it is nonetheless necessary to ask 'How should prudence be applied in the context of various practical situations.' This is perhaps particularly important where exposures are low-within...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncw310

    authors: Coates R

    更新日期:2017-04-01 00:00:00

  • A survey of patient dose and clinical factors in a full-field digital mammography system.

    abstract::In this work, we analyse the dose to 5034 patients (20 137 images) who underwent mammographic examinations with a full-field digital mammography (FFDM) system over a 2-y period. The information relevant to this study has been extracted from the image Digital Imaging and Communications in Medicine (DICOM) headers. Entr...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch514

    authors: Morán P,Chevalier M,Ten JI,Fernández Soto JM,Vañó E

    更新日期:2005-01-01 00:00:00

  • Performance of CVD diamond as an optically and thermally stimulated luminescence dosemeter.

    abstract::Diamond is a material with extreme physical properties. Its radiation hardness, chemical inertness and tissue equivalence qualify it as an ideal material for radiation dosimetry. In the present work, the optically stimulated luminescence (OSL) and thermoluminescence (TL) characteristics of a 10 microm thick CVD diamon...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci667

    authors: Preciado-Flores S,Schreck M,Meléndrez R,Chernov V,Bernal R,Cruz-Vázquez C,Cruz-Zaragoza E,Barboza-Flores M

    更新日期:2006-01-01 00:00:00

  • DYNAMIC RESPONSE OF CCD ARRAY SPECTRORADIOMETERS.

    abstract::A number of factors affect the measurements by charge coupled (CCD) array spectroradiometers, including stray light, dynamic response and ambient temperature. The departure from linearity was assessed for four CCD array spectroradiometers and linearity correction calculated with standard uncertainties error estimates....

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncv396

    authors: Baczynska KA,Price LL,Khazova M

    更新日期:2016-11-01 00:00:00

  • Design of a multi-element TEPC for neutron monitoring.

    abstract::Tissue-equivalent proportional counters (TEPCs) have long been considered suitable candidate instruments for more accurate neutron monitors in nuclear power plants. It has also been recognised that the production of truly light-weight devices based on TEPCs requires further effort directed towards increasing their sen...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq538

    authors: Waker AJ,Aslam,Lori J

    更新日期:2011-02-01 00:00:00

  • Digital dual-parameter data acquisition for SP2 hydrogen-filled proportional counters.

    abstract::Hydrogen-filled proportional counters perform well as neutron spectrometers in the energy region from a few tens of keV up to ∼1.5 MeV. Unfortunately, gamma rays also generate signals in these detectors. It is possible in principle to distinguish the two types of event via the rise time of their respective signal puls...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nct262

    authors: Hawkes NP,Roberts NJ

    更新日期:2014-10-01 00:00:00

  • Modelling the 137Cs ingestion dose from consumption of marine fish in Hong Kong.

    abstract::This paper presents a compartmental model for estimating the ingestion dose, due to 137Cs, arising from the consumption of marine fish in Hong Kong. 137Cs is one of the more important radionuclides released in routine liquid effluents discharged from the Guangdong Nuclear Power Station at Daya Bay, which began commerc...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006710

    authors: Poon CB,Au SM

    更新日期:2002-01-01 00:00:00

  • Measurement of the neutron detection sensitivity of a liquid in metastable states.

    abstract::A device able to trap a liquid droplet in a host liquid in a metastable (superheated) state was developed for a better understanding of the operational principles and for an extension of the application of superheated drop detectors (SDDs). Droplets of trans-2-butene in a metastable state were exposed to Am-Be neutron...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006122

    authors: Sawamura T,Joji T,Homma A

    更新日期:2003-01-01 00:00:00

  • INTERCAL: long-term inter-comparison experiment for dose rate and spectrometric probes.

    abstract::The Schauinsland inter-calibration facility (INTERCAL) has been designed to enable long-term comparison experiments for 20 different dose rate probes from different networks. Two reference probes characterised by the European Radiation Dosimetry WG3 inter-calibration experiments in 2008 and 2009 have been installed at...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncu039

    authors: Bleher M,Doll H,Harms W,Stöhlker U

    更新日期:2014-08-01 00:00:00

  • Set-up of a passive Bonner sphere system for neutron spectrometry at mixed fields with predominant photon component based on activation detector.

    abstract::A passive Bonner sphere system (BSS), based on thermal neutron activation detectors, was developed to perform neutron spectrometry in pulsed and very intense (n-gamma) fields with predominant photon component, as those produced by high energy (>10 MV) medical linear electron accelerators. In this paper, a description ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm070

    authors: Amgarou K,Lacoste V,Muller H,Fernández F

    更新日期:2007-01-01 00:00:00

  • Different versions of the right answer: the importance of measurement uncertainty in radiation dosimetry.

    abstract::The performance of radiation dosemeters that are issued by approved individual monitoring services generally meet international standards, with typical results within a few tens of per cent of the reference value. Experienced dosimetry practitioners will understand the uncertainties and treat monitoring results with d...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq298

    authors: Gilvin P,McWhan A

    更新日期:2011-03-01 00:00:00

  • An assessment of methods for monitoring entrance surface dose in fluoroscopically guided interventional procedures.

    abstract::In the light of a growing awareness of the risks of inducing skin injuries as a consequence of fluoroscopically guided interventional procedures (FGIPs), this paper reports measurements of ESDs made during the period August 1998 to June 1999 on 137 patients undergoing cardiac, neurological and general FGIPs in the Sou...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006486

    authors: Waite JC,Fitzgerald M

    更新日期:2001-01-01 00:00:00

  • Dose effect for South Serbians due to 238U in natural drinking water.

    abstract::The use of depleted uranium ammunition in South Serbia during the 1999 Kosovo conflict raised a great deal of public concern in the Balkans. Radioactivity levels of 238U in 20 wells and lake water samples were checked from the viewpoint of internal radiation exposure for South Serbian subjects. We have measured 238U c...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm294

    authors: Sahoo SK,Matsumoto M,Shiraishi K,Fujimoto K,Cuknic O,Zunic ZS

    更新日期:2007-01-01 00:00:00

  • Assessment of effective dose in paediatric CT examinations.

    abstract::Current concerns focus on the high doses encountered in computed tomography (CT) examinations as they are extending towards younger and more radiosensitive patients. Previous work produced conversion coefficients for effective dose (E) from dose-length product (DLP) for four anatomical body regions applicable to any p...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncr288

    authors: Dougeni E,Chapple CL,Willis J,Panayiotakis G

    更新日期:2011-09-01 00:00:00

  • Detection system built from commercial integrated circuits for real-time measurement of radiation dose and quality using the variance method.

    abstract::A small, specialised amplifier using commercial integrated circuits (ICs) was developed to measure radiation dose and quality in real time using a microdosimetric ion chamber and the variance method. The charges from a microdosimetric ion chamber, operated in the current mode, were repeatedly collected for a fixed per...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm231

    authors: Hsu WH,Braby LA,Reece WD

    更新日期:2008-01-01 00:00:00

  • Mammography dose in relation to body mass index, race, and menopausal status.

    abstract::Mammography dose increases with compressed breast thickness (CBT), but few studies have examined other correlates of dose. The purpose of this study was to evaluate the relation between factors such as race, age, body mass index (BMI), CBT, and menopausal status and mammography screening dose, measured for 509 women i...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006733

    authors: Schubauer-Berigan MK,Frey GD,Baron L,Hoel DG

    更新日期:2002-01-01 00:00:00

  • Entrance surface, organ and effective doses for some of the patients undergoing different types of X ray procedures in Bangladesh.

    abstract::Entrance surface doses (ESDs) were measured for the most common types of X ray procedures, such as chest PA, lumber spine AP, lumber spine lateral, skull AP, skull lateral and pelvis AP in four major hospitals of Dhaka, the capital city of Bangladesh. Organ/tissue doses for 29 organs/tissues and effective doses for th...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006549

    authors: Begum Z

    更新日期:2001-01-01 00:00:00

  • The resulting skin dose in two-view mammography examinations.

    abstract::The entrance surface dose (ESD) (skin dose) and its variation due to overlapping radiation fields at mammography have been experimentally investigated on patients during two-view mammography screening examinations of both breasts and on phantoms of silicon gel. Measurements were done using multiple thermoluminescence ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq077

    authors: Adliene D,Cibulskaite I,Laurikaitiene J,Adlys G

    更新日期:2010-04-01 00:00:00

  • Reference dosimetry for light-ion beams based on graphite calorimetry.

    abstract::Developments in hadron therapy require efforts to improve the accuracy of the dose delivered to a target volume. Here, the determination of the absorbed dose under reference conditions was analysed. Based on the International Atomic Energy Agency TRS-398 code of practice, for hadron beams, the combined standard uncert...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nct299

    authors: Rossomme S,Palmans H,Thomas R,Lee N,Duane S,Bailey M,Shipley D,Bertrand D,Romano F,Cirrone P,Cuttone G,Vynckier S

    更新日期:2014-10-01 00:00:00

  • Determination of human absorbed dose of 201Tl(III)-DTPA-HIgG based on biodistribution data in rats.

    abstract::To estimate the absorbed dose in normal organs and inflamed tissue following i.v. administration of [201Tl](III)-DTPA-HIgG by using biodistribution data in inflamation bearing rats was attempted. The percentages of injected dose per gram of each organ were calculated. The medical internal radiation dose formulation was...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq172

    authors: Khorrami Moghaddam A,Reza Jalilian A,Hayati V,Shanehsazzadeh S

    更新日期:2010-10-01 00:00:00

  • Radiation protection at low energy proton accelerators.

    abstract::A sample is provided of the radiological safety issues particular to low energy proton accelerators. 'Low' energy in this context is taken to mean proton energies of less than about 1 GeV. Many of the radiation issues are common to all particle accelerators. Here, those issues are addressed that may require perhaps no...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章,评审

    doi:10.1093/oxfordjournals.rpd.a006619

    authors: Moritz LE

    更新日期:2001-01-01 00:00:00

  • The influence of novel CT reconstruction technique and ECG-gated technique on image quality and patient dose of cardiac computed tomography.

    abstract::The aim of the present study was to compare image quality and patient dose in cardiac computed tomography angiography (CTA) in terms of volume computed tomography dose index (CTDI vol), dose length product (DLP) and effective dose, when changing from filtered back projection (FBP) to adaptive iterative dose reduction ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncv114

    authors: Dyakov I,Stoinova V,Groudeva V,Vassileva J

    更新日期:2015-07-01 00:00:00

  • Dose performance evaluation of a charge coupled device and a flat-panel digital fluoroscopy system recently installed in an interventional cardiology laboratory.

    abstract::The purpose of the study was to evaluate the dose performance of a flat-panel (FP) and an image intensifier (II) charge coupled device (CCD) digital fluoroscopy X-ray systems newly installed in an Interventional Cardiology (IC) department. Filter entrance dose rate, detector dose rate (during fluoroscopy) and filter e...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch344

    authors: Tsapaki V,Kottou S,Kollaros N,Dafnomili P,Kyriakidis Z,Neofotistou V

    更新日期:2004-01-01 00:00:00

  • Radiation dose aspects in the handling of emerging nuclear fuels.

    abstract::The occupational annual dose levels, encountered at fabrication of emerging nuclear fuels, have been studied. Emerging fuels for the single and multiple recycling of Pu and MA have resulted in considerably higher gamma and neutron doses in comparison with commercial fuels. The occupational dose limit is exceeded at fa...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncu016

    authors: Nicolaou G