Abstract:
:A small, specialised amplifier using commercial integrated circuits (ICs) was developed to measure radiation dose and quality in real time using a microdosimetric ion chamber and the variance method. The charges from a microdosimetric ion chamber, operated in the current mode, were repeatedly collected for a fixed period of time for 20 cycles of 100 integrations, and processed by this specialised amplifier to produce signal pulse heights between 0 and 10 V. These signals were recorded by a multi-channel analyser coupled to a computer. FORTRAN programs were written to calculate the dose and dose variance. The dose variance produced in the ion chamber is a microdosimetric measure of radiation quality. Benchmark measurements of different brands of ICs were conducted. Results demonstrate that this specialised amplifier is capable of distinguishing differences of radiation quality in various high-dose-rate radiation fields including X rays, gamma rays and mixed neutron-gamma radiation from the research reactor at Texas A&M University Nuclear Science Center.
journal_name
Radiat Prot Dosimetryjournal_title
Radiation protection dosimetryauthors
Hsu WH,Braby LA,Reece WDdoi
10.1093/rpd/ncm231subject
Has Abstractpub_date
2008-01-01 00:00:00pages
5-11issue
1eissn
0144-8420issn
1742-3406pii
ncm231journal_volume
128pub_type
杂志文章abstract::During the operation of high-energy accelerators, the interaction of radiation with matter can lead to the activation of the machine components and of the surrounding infrastructures. As a result of maintenance operation and during decommissioning of the installation, considerable amounts of radioactive waste are evac...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncp196
更新日期:2009-11-01 00:00:00
abstract::The measurement of indoor radon concentrations were performed in the dwellings of the Punjab and Himachal Pradesh, India by using LR-115 type II Solid-State Nuclear Track Detectors in the bare mode. The annual average indoor radon concentrations in the dwellings are found to vary from 114 to 400 Bq m(-3) with an avera...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/nct041
更新日期:2013-01-01 00:00:00
abstract::There have been few studies on the secondary cancer after radiation treatment in Chinese hospitals. This study has measured out-of-field absorbed organ doses from intensity-modulated radiation therapy (IMRT) radiotherapy for esophageal cancer in a Chinese hospital and evaluated the risks of secondary cancer. The dose ...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncx057
更新日期:2017-12-01 00:00:00
abstract::Improved radiation protection of humans requires a better understanding of the mechanisms of radiation action and accurate estimates of radiation risk for both internal and external radiations. The Japanese atomic bomb survivors represent one of the most important sources of human data on the late carcinogenic effects...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/oxfordjournals.rpd.a006532
更新日期:2001-01-01 00:00:00
abstract::The Techa river region was highly contaminated due to radioactive releases from a nuclear production facility in the period from 1949 to 1956. The inhabitants of the upper Techa river settlements received significant doses of external radiation. The majority of the houses in the upper Techa river villages were demolis...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/oxfordjournals.rpd.a005972
更新日期:2002-01-01 00:00:00
abstract::To study the radiation environment inside the International Space Station, solid state nuclear track detector stacks were used. Within the BRADOS experiments, Phase 1, seven stacks were exposed at different locations of the Russian segment 'Zvezda' for 248 days in 2001. It was supposed that the radiation field inside ...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/nci673
更新日期:2006-01-01 00:00:00
abstract::Bonner sphere spectrometers (BSSs) are employed in neutron spectrometry and dosimetry since many years. Recent developments have seen the addition to a conventional BSS of one or more detectors (moderator plus thermal neutron counter) specifically designed to improve the overall response of the spectrometer to neutron...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/nch187
更新日期:2004-01-01 00:00:00
abstract::The purpose of this paper is to evaluate the image quality and dose to patients in the radiography of sacroiliac joints and to perform a clinical comparative study of digital and conventional screen-film radiography. Routine radiography of sacroiliac joint was performed in 60 patients using digital and screen-film rad...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncs315
更新日期:2013-06-01 00:00:00
abstract::Microbeam facilities provide a unique opportunity to investigate the effects of ionising radiation on living biological cells with a precise control of the delivered dose. This paper describes dosimetry calculations performed at the single-cell level in the microbeam irradiation facility available at the Centre d'Etud...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncp003
更新日期:2009-01-01 00:00:00
abstract::A programme of harmonization of individual dosimetry quality control organized in the framework of a distributed metrology system is presented as seen from the experiences gained in Slovenia. As a part of the programme intercomparison of dosimetry services was organized and basic characteristics of dosimetry systems c...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncm198
更新日期:2007-01-01 00:00:00
abstract::For an accurate determination of the absorbed doses in complex radiation fields (e.g. mixed neutron-gamma fields), a better interpretation of the response of ionisation chambers is required. This study investigates a model of the ionisation chambers using a different approach, analysing the collected charge per minute...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncm484
更新日期:2008-01-01 00:00:00
abstract::The technique of alpha spectrometry is used to detect alpha particles and to determine their energy. In this way the technique is able to provide simultaneously quantitative information (i.e. the activity) and qualitative information (the identity) on any radionuclide that emits an alpha particle. The longer-lived nat...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/oxfordjournals.rpd.a006646
更新日期:2001-01-01 00:00:00
abstract::To find appropriate substitutions for the expensive plastics of A-150 and rexolite used in the construction of thick gas electron multiplier (THGEM)-based tissue-equivalent proportional counters, in the present work, the responses of a THGEM-based microdosimetric detector made of A-150 and rexolite and three others co...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncw008
更新日期:2017-04-15 00:00:00
abstract::One of the topics which forms part of CONRAD project addresses the problems related to the dosimetry of complex-mixed radiation fields at workplaces. This topic was included in work package (WP) 6. WP 6 was established to co-ordinate research activities in two areas:the development of new techniques and the improvemen...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncn220
更新日期:2008-01-01 00:00:00
abstract::Chips of a radiophotoluminescence glass dosemeter (RPLG) were used for measurements of space radiation during a 9.8 d Shuttle-Mir mission (STS-91) at an altitude of 400 km and an inclination of 51.65 degrees. Two of RPLG chips were put into each of 59 positions in or on a life-size human phantom. The RPLG values equiv...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/oxfordjournals.rpd.a005933
更新日期:2002-01-01 00:00:00
abstract::The results of experimental studies performed in a radiotherapy (12)C ion beam with a nominal energy of 500 MeV/amu and in (16)O and (56)Fe ion beams with a nominal energy of 1 GeV/amu have been described. Linear energy transfer (LET) spectra have been established by means of an LET spectrometer based on a chemically ...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncm133
更新日期:2007-01-01 00:00:00
abstract::A wire patch cell (WPC) operating at the uplink frequency band of GSM 1800 MHz has been designed for in vitro experiments with the aim of investigating the possible biological effects of electromagnetic radiation associated with cellular phones. The 1800 MHz WPC design is a direct descendant of the original 900 MHz WP...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/nch414
更新日期:2004-01-01 00:00:00
abstract::In a previous paper, conversion coefficients for the personal dose equivalent, H(p)(d), for photons were reported. This note reports values for electrons calculated using similar techniques. The personal dose equivalent is the quantity used to approximate the protection quantity effective dose when performing personal...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncr252
更新日期:2012-04-01 00:00:00
abstract::The evaluation of exposure to extremely low-frequency (ELF) magnetic fields using broadband measurement techniques gives satisfactory results when the field has essentially a single frequency. Nevertheless, magnetic fields are in most cases distorted by harmonic components. This work analyses the harmonic components o...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncu175
更新日期:2015-02-01 00:00:00
abstract::In environmental radiation monitoring, the time-variable natural gamma radiation background complicates the nuclide identification and analysis of a gamma spectrum. A full spectrum analysis based on the noise adjusted singular value decomposition method for the description of the time-variable background and adjustmen...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncu144
更新日期:2014-08-01 00:00:00
abstract::For the calibration of personal dosemeters in terms of H(p)(10), the ISO water slab phantom shall be used. The irradiation geometry must be chosen such that the field diameter at the phantom front surface is large enough to irradiate the phantom completely and, in addition, homogeneously. However, in practice it is no...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncq036
更新日期:2010-06-01 00:00:00
abstract::Polycrystalline CaSO4 powder, doped with different elements but mainly rare earths, is one of the most interesting thermoluminescent (TL) materials. Although many electron spin resonance (ESR) analyses have been reported for these materials few studies have been published about the potential of CaSO4 for ESR dosimetry...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/oxfordjournals.rpd.a006047
更新日期:2002-01-01 00:00:00
abstract::Thermoluminescence (TL) dose responses to gamma radiation in the dose range from 0.1 Gy to 20 kGy in MgSO4:Dy, MgSO4:Dy,Mn, MgSO4:Dy,P and MgSO4:Dy,P,Cu phosphors were obtained and fitted by the composite action dose response function to obtain non-linear characteristic parameters, one-hit factor R and characteristic ...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/oxfordjournals.rpd.a005824
更新日期:2002-01-01 00:00:00
abstract::The main dosimetric properties are reported of a new perovskite, LiMgF3, doped with Ce, Er and Dy impurities. An annealing temperature of 400 degrees C for one hour is necessary to erase any previous signal and to stabilise its sensitivity. A readout up to 450 degrees C gives the same result. The glow curve structure ...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/oxfordjournals.rpd.a005858
更新日期:2002-01-01 00:00:00
abstract::Results of performance tests verifying the dosimetric properties of dosimetric systems are published in various reports (e.g. IAEA and EURADOS). However, there is hardly any information in the open literature relating to the uncertainty in a dose measurement or in the annual dose, which is increased by failure of the ...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/nch287
更新日期:2004-01-01 00:00:00
abstract::Estimating organ absorbed doses in consideration of person-specific parameters is important for radiation protection in diagnostic nuclear medicine. This study proposes a straightforward method for estimating the organ dose that reflects a specific organ mass by scaling the reference organ dose using the inverse ratio...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncaa058
更新日期:2020-07-24 00:00:00
abstract::Biokinetic models are the scientific underpinning of internal dosimetry and depend, ultimately, for their scientific validation on comparisons with human bioassay data. Three significant plutonium/americium bioassay databases, known to the authors, are described: (1) Sellafield, (2) Los Alamos and (3) the United State...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncm164
更新日期:2007-01-01 00:00:00
abstract::A method using europium-doped BaFBr imaging plates (IPs) has been studied for mapping entrance skin doses during interventional radiology (IR); the mapping is useful for detecting overlap between irradiation fields and determining the most exposed skin areas. IPs, which are two-dimensional radiation sensors made of ph...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/nch468
更新日期:2005-01-01 00:00:00
abstract::A comparison is presented of particular methods of exposure in the first year after the Chernobyl disaster and ten years later. This comparison shows that the population exposure due to the presence of radiocaesium in the environment results from the presence of caesium contained in the soil, which provides 68% of the...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/oxfordjournals.rpd.a006725
更新日期:2002-01-01 00:00:00
abstract::The availability of active neutron personal dosemeters has made real time monitoring of neutron doses possible. This has obvious benefits, but is only of any real assistance if the dose assessments made are of sufficient accuracy and reliability. Preliminary assessments of the performance of active neutron dosemeters ...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncm095