Further progress in the characterisation of complex radiation fields.

Abstract:

:One of the topics which forms part of CONRAD project addresses the problems related to the dosimetry of complex-mixed radiation fields at workplaces. This topic was included in work package (WP) 6. WP 6 was established to co-ordinate research activities in two areas:the development of new techniques and the improvement of current techniques for characterisation of complex workplace fields (including high-energy fields and pulsed fields): measurement and calculation of particle energy and direction distributions (Subgroup A); and model improvements for dose assessment of solar particle events (Subgroup B). In both cases in order to aid the research, WP 6 increases the efficiency of resource utilisation, and facilitates the technology transfer to practical application and for the development of standards. This contribution presents a general overview of activities of SG A; specific results related to the benchmark experiment at GSI Darmstadt are presented separately, and will be published in other way. As far as the results acquired in the frame of the SG B activities, these are presented in the meeting held as part of EURADOS AM 2008.

journal_name

Radiat Prot Dosimetry

authors

Spurny F,Silari M

doi

10.1093/rpd/ncn220

subject

Has Abstract

pub_date

2008-01-01 00:00:00

pages

46-50

issue

1

eissn

0144-8420

issn

1742-3406

pii

ncn220

journal_volume

131

pub_type

杂志文章
  • Entrances skin dose distribution maps for interventional neuroradiological procedures: a preliminary study.

    abstract::Dose estimation in interventional neuroradiology can be useful to limit skin radiation injuries. The purpose of this study was to evaluate the role of entrance skin dose (ESD) maps in planning exposure condition optimisation. Thirteen cerebral angiography and five embolisation procedures were monitored, measuring ESD,...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci759

    authors: Rampado O,Ropolo R

    更新日期:2005-01-01 00:00:00

  • Secondary neutron doses in proton therapy treatments of ocular melanoma and craniopharyngioma.

    abstract::Monte Carlo simulations were used to assess secondary neutron doses received by patients treated with proton therapy for ocular melanoma and craniopharyngioma. MCNPX calculations of out-of-field doses were done for ∼20 different organs considering realistic treatment plans and using computational phantoms representati...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nct283

    authors: Farah J,Sayah R,Martinetti F,Donadille L,Lacoste V,Hérault J,Delacroix S,Nauraye C,Vabre I,Lee C,Bolch WE,Clairand I

    更新日期:2014-10-01 00:00:00

  • Neutron measurements in a Varian 2,100C LINAC facility using a Bonner sphere system based on passive gold activation detectors.

    abstract::The use of high-energy linear electron accelerators (LINACs) for medical cancer treatments is widespread on an international scale. The associated bremsstrahlung X rays may produce neutrons as a result of subsequent photonuclear reactions with the different materials constituting the accelerator head. The generated ne...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm075

    authors: Fernández F,Domingo C,Amgarou K,Castelo J,Bouassoule T,Garcia MJ,Luguera E

    更新日期:2007-01-01 00:00:00

  • Assessment of occupational exposure to uranium by indirect methods needs information on natural background variations.

    abstract::Urine monitoring is the preferred method to determine exposure to soluble compounds of uranium in workplaces. The interpretation of uranium contents in workers bioassay samples requires knowledge on uranium excretion and its dependence on intake by diet. Exceptionally high concentrations of natural uranium in private ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm155

    authors: Muikku M,Heikkinen T,Puhakainen M,Rahola T,Salonen L

    更新日期:2007-01-01 00:00:00

  • Organisation and delivery of imaging services: the contributions of ethics and political economy.

    abstract::The objective of this discussion is to explore how theories from other disciplines can contribute to the debate on organisation and delivery of diagnostic and therapeutic exposures. The first part explores how theories of justice suggest that health services should be provided; the second part explores how stakeholder...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncp043

    authors: Durand-Zaleski I

    更新日期:2009-07-01 00:00:00

  • New Correction Factors Based on Seasonal Variability of Outdoor Temperature for Estimating Annual Radon Concentrations in UK.

    abstract::Indoor radon concentrations generally vary with season. Radon gas enters buildings from beneath due to a small air pressure difference between the inside of a house and outdoors. This underpressure which draws soil gas including radon into the house depends on the difference between the indoor and outdoor temperatures...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncw270

    authors: Daraktchieva Z

    更新日期:2017-06-01 00:00:00

  • Head calibration phantoms for actinides: measurements and simulations.

    abstract::The paper deals with the physical skull phantoms Bundesinstitut fuer Strahlenschutz and BPAM-001, which are used in order to calibrate in vivo detection systems for estimation of (241)Am activity in the skeleton. Their voxel models were made and used in the Monte Carlo simulations. The results of the simulation were c...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq491

    authors: Vrba T

    更新日期:2011-03-01 00:00:00

  • Exposure estimates based on broadband ELF magnetic field measurements versus the ICNIRP multiple frequency rule.

    abstract::The evaluation of exposure to extremely low-frequency (ELF) magnetic fields using broadband measurement techniques gives satisfactory results when the field has essentially a single frequency. Nevertheless, magnetic fields are in most cases distorted by harmonic components. This work analyses the harmonic components o...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncu175

    authors: Paniagua JM,Rufo M,Jiménez A,Pachón FT,Carrero J

    更新日期:2015-02-01 00:00:00

  • Natural radioactivity intake into wheat grown on fertilized farms in two districts of Pakistan.

    abstract::The use of phosphate fertilizers on agricultural farms enhances gamma-ray activity concentration in the farms and therefore absorbed dose rates to the public. The most common natural radionuclides in fertilizer and soil are (40)K, (226)Ra and (232)Th. Agricultural farms at four locations in two districts in Pakistan c...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncl100

    authors: Nasim-Akhtar,Tufail M

    更新日期:2007-01-01 00:00:00

  • MEASUREMENTS OF SPATIAL CORRELATIONS OF IONISATION CLUSTERS IN THE TRACK OF CARBON IONS-FIRST RESULTS.

    abstract::An attempt towards an experimental set up which could provide the experimental data on correlation processes occurred simultaneously in two distanced DNA targets within a charged particle track is presented. A modified Jet Counter nanodosemeter was used in two experiments with carbon ions with mean energies of 52 and ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncy079

    authors: Pietrzak M,Pszona S,Bantsar A

    更新日期:2018-08-01 00:00:00

  • Energy responses of the LiF series TL pellets to high-energy photons in the energy range from 1.25 to 21 MV.

    abstract::The energy responses for the KLT-300(LiF:Mg,Cu,Na,Si, Korea), GR-200(LiF:Mg,Cu,P, China) and MCP-N(LiF:Mg,Cu,P, Poland) thermoluminescence(TL) pellets were studied for a photon radiation with energies from 1.25 MeV(60Co) to 21 MV (Microtron) to verify the usefulness of the calibration for the radiotherapy beams. The I...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci627

    authors: Kim JL,Lee JI,Ji YH,Kim BH,Kim JS,Chang SY

    更新日期:2006-01-01 00:00:00

  • CHARACTERIZATION OF 27 MEV PROTON BEAM GENERATED BY TOP-IMPLART LINEAR ACCELERATOR.

    abstract::The first proton linear accelerator for tumor therapy based on an actively scanned beam up to the energy of 150 MeV, is under development and construction by ENEA-Frascati, ISS and IFO, under the Italian TOP-IMPLART project. Protons up to the energy of 7 MeV are generated by a customized commercial injector operating ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncy001

    authors: De Angelis C,Ampollini A,Basile E,Cisbani E,Della Monaca S,Ghio F,Montereali RM,Picardi L,Piccinini M,Placido C,Ronsivalle C,Soriani A,Strigari L,Trinca E,Vadrucci M

    更新日期:2018-08-01 00:00:00

  • COMPARISON OF DIFFERENT TECHNIQUES FOR EVALUATION OF DOSE DISTRIBUTIONS IN RADIOTHERAPY USING RADIOCHROMIC EBT3 FILMS.

    abstract::In radiotherapy, radiochromic films can be used for verification of delivery of dose distributions calculated by treatment planning systems. The main objective of this work was to compare three different techniques for evaluation of dose distributions for prostate cancer treatment plans using radiochromic EBT3 films. ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncz231

    authors: Dufek V,Horakova I,Koniarova I

    更新日期:2019-12-31 00:00:00

  • A THIN-LAYER LIF THERMOLUMINESCENCE DOSEMETER SYSTEM WITH FAST READOUT FOR THE USE IN PERSONAL DOSIMETRY SERVICES.

    abstract::A newly developed thermoluminescence dosemeter system is presented that is suitable for application in fields where personal monitoring of a large number of users is required. The system presented here is intended to be used as the upcoming main dosemeter for whole body dosimetry at the dosimetry service of the MPA NR...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncv478

    authors: Walbersloh J,Busch F

    更新日期:2016-09-01 00:00:00

  • The study of activity median aerodynamic diameter using imaging plate technique for assessment of effective dose from radon and its decay products.

    abstract::The indoor workplace environment was evaluated for exposure to radon and its decay products at two Universities in two metropolises of Japan. The mean radon concentrations in Nagoya University (NU) and Hokkaido University (HU) were 16.7 Bq m(-3) and 18.0 Bq m(-3), respectively. Activity median aerodynamic diameter (AM...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章,多中心研究

    doi:10.1093/rpd/ncm221

    authors: Rahman NM,Iida T,Yamazawa H,Yokoyama S,Moriizumi J,Saito F,Ito T

    更新日期:2007-01-01 00:00:00

  • Excess radiation absorbed doses from non-optimised radioiodine treatment of hyperthyroidism.

    abstract::Radioiodine therapy is often the method of choice for treatment of hyperthyroidism because it is considered safe, is relatively inexpensive, and is convenient for the patient and except for occasional hypothyroidism, almost without side effects. Even though radioiodine treatment has been performed for over 50 years, t...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch013

    authors: Jönsson H,Mattsson S

    更新日期:2004-01-01 00:00:00

  • EXPERIMENTAL VALIDATION OF ALGORITHMS USED TO ESTIMATE EFFECTIVE DOSE DURING INTERVENTIONAL RADIOLOGY PROCEDURES.

    abstract::In IR procedures, in order to evaluate the effective dose, the importance of the double dosemeter has been recognised, one worn above and one under the apron. Over the last few decades several algorithms have been developed to combine the readings of the dosemeters, however currently there is no international consensu...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncz136

    authors: Negri P,Campi F,De Crescenzo S,Garlati L,Tambussi O

    更新日期:2019-12-31 00:00:00

  • Modelling of nuclear power plant decommissioning financing.

    abstract::Costs related to the decommissioning of nuclear power plants create a significant financial burden for nuclear power plant operators. This article discusses the various methodologies employed by selected European countries for financing of the liabilities related to the nuclear power plant decommissioning. The article...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncv333

    authors: Bemš J,Knápek J,Králík T,Hejhal M,Kubančák J,Vašíček J

    更新日期:2015-06-01 00:00:00

  • GAMMA DOSE RATES IN THE HIGH BACKGROUND RADIATION AREA OF MANGALORE REGION, INDIA.

    abstract::Elevated levels of natural background radiation due to scattered patches of monazite sand around the beaches of Mangalore, India, have been reported earlier. A comparative study of gamma dose rates was performed in both normal background and high natural background radiation areas around Mangalore using different type...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncz063

    authors: Al-Azmi D,Kumara S,Mohan MP,Karunakara N

    更新日期:2019-10-01 00:00:00

  • Ethical issues in radiology: perspectives from the Christian tradition.

    abstract::The Christian ethical tradition introduces a number of key values into the clinical context. Moreover, although some denominational differences exist, these are essentially differences of emphasis rather than of substance. Among the central values which the Christian tradition promotes are: the dignity of the person, ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncp044

    authors: Hogan L

    更新日期:2009-07-01 00:00:00

  • Gamma-ray emitting test sources for Portal Monitors used for homeland security.

    abstract::The National Institute of Standards and Technology developed a new set of test sources for testing of portal monitors against the ANSI standard N42.35-2004. The design and source specifications are provided in this work. ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch422

    authors: Lucas L,Pibida L,Unterweger M,Karam L

    更新日期:2005-01-01 00:00:00

  • Neutron dose calculation at the maze entrance of medical linear accelerator rooms.

    abstract::Currently, teletherapy machines of cobalt and caesium are being replaced by linear accelerators. The maximum photon energy in these machines can vary from 4 to 25 MeV, and one of the great advantages of these equipments is that they do not have a radioactive source incorporated. High-energy (E > 10 MV) medical linear ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncl144

    authors: Falcão RC,Facure A,Silva AX

    更新日期:2007-01-01 00:00:00

  • Shielding design of a brachytherapy unit at the Korle Bu teaching hospital in Ghana: comparison of theoretical calculations and experimental study.

    abstract::A theoretical study was carried out to re-evaluate the integrity of the biological shielding of (137)Cs brachytherapy unit at the Korle Bu Teaching Hospital, Ghana, and the results were verified by measurement of the dose rates at selected locations. The primary objective was to determine the current state of protecti...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq001

    authors: Arwui CC,Schandorf C,Nani K,Darko EO,Deatanyah P

    更新日期:2010-06-01 00:00:00

  • A software tool for increased efficiency in observer performance studies in radiology.

    abstract::Observer performance studies are time-consuming tasks, both for the participating observers and for the scientists collecting and analysing the data. A possible way to optimise such studies is to perform them in a completely digital environment. A software tool-ViewDEX (Viewer for Digital Evaluation of X-ray images)-h...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch550

    authors: Börjesson S,Håkansson M,Båth M,Kheddache S,Svensson S,Tingberg A,Grahn A,Ruschin M,Hemdal B,Mattsson S,Månsson LG

    更新日期:2005-01-01 00:00:00

  • Specific absorbed fraction for Korean adult voxel phantom from internal photon source.

    abstract::Absorbed fraction (AF) and specific absorbed fraction (SAF) are crucial values for the calculation of radionuclide S-values and consequently for internal dose estimates. The formalism of the Medical Internal Radiation Dose (MIRD) committee of the Society of Nuclear Medicine (SNM) has been utilised as a standard in the...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncl167

    authors: Lee C,Park S,Lee JK

    更新日期:2007-01-01 00:00:00

  • Determination of the absorbed dose and the average LET of space radiation in dependence on shielding conditions.

    abstract::The HTR method, developed for determination of absorbed dose and average LET of mixed radiation fields in space, was applied during several space missions on space station MIR, space shuttles and satellites. The method utilises the changes of peak height ratios in the glow curves in dependence on the linear energy tra...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a032854

    authors: Vana N,Schoner W,Noll M,Fugger M,Akatov Y,Shurshakov V

    更新日期:1999-01-01 00:00:00

  • Simultaneous measurements of indoor radon, radon-thoron progeny and high-resolution gamma spectrometry in Greek dwellings.

    abstract::Simultaneous indoor radon, radon-thoron progeny and high-resolution in situ gamma spectrometry measurements, with portable high-purity Ge detector were performed in 26 dwellings of Thessaloniki, the second largest town of Greece, during March 2003-January 2005. The radon gas was measured with an AlphaGUARD ionisation ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci366

    authors: Clouvas A,Xanthos S,Antonopoulos-Domis M

    更新日期:2006-01-01 00:00:00

  • EXPOSURE ASSESSMENT OF PORTABLE WIRELESS DEVICES ABOVE 6 GHz.

    abstract::The emerging 5 G wireless devices working at frequencies above 6 GHz are expected to have antenna arrays formed by dipoles, slots, patches or their combination. At lower frequencies, the accepted criteria for exposure compliance is stated in terms of specific absorption rate. IEEE and ICNIRP are adopting epithelial or...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncy177

    authors: Carrasco E,Colombi D,Foster KR,Ziskin M,Balzano Q

    更新日期:2019-06-01 00:00:00

  • Exposure caused by wireless technologies used for short-range indoor communication in homes and offices.

    abstract::In order to estimate typical radio frequency exposures from indoor used wireless communication technologies applied in homes and offices, WLAN, Bluetooth and Digital Enhanced Cordless Telecommunications systems, as well as baby surveillance devices and wireless headphones for indoor usage, have been investigated by me...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm245

    authors: Schmid G,Lager D,Preiner P,Uberbacher R,Cecil S

    更新日期:2007-01-01 00:00:00

  • Use of various microdosimetric models for the prediction of radon induced damage in human lungs.

    abstract::Exposure to radon and radon decay products in some residential areas and at workplaces constitutes one of the greatest risks from natural sources of ionising radiation. Recently, increasing attention has been paid to the precise estimations of this health risk by numerous models. The compartmental model published in I...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006173

    authors: Böhm R,Nikodémová D,Holý K

    更新日期:2003-01-01 00:00:00