Validating a MCNPX model of Mg(Ar) and TE(TE) ionisation chambers exposed to 60CO gamma rays.

Abstract:

:For an accurate determination of the absorbed doses in complex radiation fields (e.g. mixed neutron-gamma fields), a better interpretation of the response of ionisation chambers is required. This study investigates a model of the ionisation chambers using a different approach, analysing the collected charge per minute as a response of the detector instead of the dose. The MCNPX Monte Carlo code is used. In this paper, the model is validated using a well-known irradiation field only: a (60)Co source. The detailed MCNPX models of a Mg(Ar) and TE(TE) ionisation chamber is investigated comparing the measured charge per minute obtained free-in-air and in a water phantom with the simulated results. The difference between the calculations and the measurements for the TE(TE) chamber is within +/-2% whereas for the Mg(Ar) chamber is around +7%. The systematic discrepancy in the case of Mg(Ar) chamber is expected to be caused by an overestimation of the sensitive volume.

journal_name

Radiat Prot Dosimetry

authors

Roca A,Nievaart VA,Moss RL,Stecher-Rasmussen F,Zamfir NV

doi

10.1093/rpd/ncm484

subject

Has Abstract

pub_date

2008-01-01 00:00:00

pages

365-71

issue

4

eissn

0144-8420

issn

1742-3406

pii

ncm484

journal_volume

129

pub_type

杂志文章
  • The shielding design process--new plants to decommissioning.

    abstract::BNFL have over 25 years experience of designing nuclear plant for the whole-fuel cycle. In the UK, a Nuclear Decommissioning Authority (NDA) is to be set up to ensure that Britain's nuclear legacy is cleaned up safely, securely and cost effectively. The resulting challenges and opportunities for shielding design will ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章,评审

    doi:10.1093/rpd/nci171

    authors: Jeffries G,Cooper A,Hobson J

    更新日期:2005-01-01 00:00:00

  • A comparative study of quality control in diagnostic radiology.

    abstract::The main objective of this comparative study was to evaluate the national quality assurance program for X-ray diagnostic radiology in Syrian governmental hospitals. Two periods were covered in this study, the first period was from 1986 to 1998 (52 hospitals and 149 X-ray machines were considered) and the second period...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncn096

    authors: Kharita MH,Khedr MS,Wannus KM

    更新日期:2008-01-01 00:00:00

  • Exposures from nuclear medicine diagnostic procedures: the dose impact on the Aosta Valley population.

    abstract::The present work evaluates the per-procedure, annual collective and per-capita effective doses to the Aosta Valley region population from nuclear medicine (NM) examinations performed from 2005 to 2011 at the regional NM department. Based on its demographical and socioeconomics characteristics, this area can be conside...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nct158

    authors: Aimonetto S,Arrichiello C,Peruzzo Cornetto A,Catuzzo P,Zeverino M,Poti C,Meloni T,Pasquino M,Tofani S

    更新日期:2013-12-01 00:00:00

  • Effective dose to a patient undergoing coronary angiography.

    abstract::Detailed data relating to patient dose have been acquired for 18, randomly chosen, patients undergoing coronary angiographies. During the procedure, dose-area product (DAP), kV and beam collimation were recorded for each projection. Total DAP, fluoroscopy time and number of cine frames were also noted. Patient effecti...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006466

    authors: Lobotessi H,Karoussou A,Neofotistou V,Louisi A,Tsapaki V

    更新日期:2001-01-01 00:00:00

  • RADIOECOLOGICAL IMPACT AND THE ASSOCIATED HAZARDS DUE TO NORM FROM OIL AND GAS PRODUCTION FACILITY IN THE WESTERN DESERT OF EGYPT.

    abstract::An oil and gas production facility in the western desert of Egypt was investigated for possible radiation risks due to the routine operation. Radium-226, Radium-228 and Potassium-40 were assessed in the soil samples collected from the adjacent soakaway pond. The average 226Ra, 228Ra and 40K activity concentrations wer...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncaa084

    authors: Ebaid YY,Hassan Y,Elshemey WM

    更新日期:2020-08-28 00:00:00

  • Alpha particle energy response of 1-mm-thick polycarbonate track detectors by 50 Hz-HV electrochemical etching method.

    abstract::The electrochemical etching (ECE) method enlarges charged particle tracks to enhance its applications in particular in health physics and radiation dosimetry. The ECE method is usually based on using a high frequency-high voltage (HF-HV) generator with 250-µm-thick polycarbonate track detectors (PCTDs). The authors' r...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncu303

    authors: Sohrabi M,Ramezani V

    更新日期:2015-04-01 00:00:00

  • Would children be adequately protected by existing intervention levels during a radionuclear emergency?

    abstract::The question arises as to whether radiation standards and guidelines set for adults are sufficiently protective of children. To answer this question, published literature values have been used to calculate radiation doses to children and adults from external and internal exposure to a suite of 30 radionuclides commonl...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq202

    authors: Tracy BL

    更新日期:2010-11-01 00:00:00

  • Measured proton sensitivities of bubble detectors.

    abstract::The neutron dose equivalent in aircraft is measured using commercial bubble detectors, but at high altitudes there are not only neutrons but also protons. Bubble detectors have been used because they are considered not to be sensitive to protons, but this has been the subject of only a few studies. In this study, by i...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch330

    authors: Takada M,Kitamura H,Koi T,Nakamura T,Fujitaka K

    更新日期:2004-01-01 00:00:00

  • Validation of a Monte Carlo efficiency calibration procedure for a partial body counter system with a voxel model of the LLNL torso phantom.

    abstract::Virtual models of real phantoms used with Monte Carlo methods facilitate the calibration and other studies associated with whole-body and partial-body counting systems. In this investigation, a voxel model of an LLNL torso phantom, available physically in the in vivo laboratory at KIT, was created from computed tomogr...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncp030

    authors: Hegenbart L,Marzocchi O,Breustedt B,Urban M

    更新日期:2009-02-01 00:00:00

  • Efficiency of a radiophotoluminescence glass dosemeter for low-earth-orbit space radiation.

    abstract::Chips of a radiophotoluminescence glass dosemeter (RPLG) were used for measurements of space radiation during a 9.8 d Shuttle-Mir mission (STS-91) at an altitude of 400 km and an inclination of 51.65 degrees. Two of RPLG chips were put into each of 59 positions in or on a life-size human phantom. The RPLG values equiv...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a005933

    authors: Yasuda H,Fujitaka K

    更新日期:2002-01-01 00:00:00

  • DEVELOPMENT OF HETEROGENEOUS PROPORTIONAL COUNTERS FOR NEUTRON DOSIMETRY.

    abstract::The use of a custom-made cylindrical graphite proportional counter (Cy-GPC) along with a cylindrical tissue equivalent proportional counter (TEPC) for neutron-gamma mixed-field dosimetry has been studied in the following steps: first, the consistency of the gamma dose measurement between the Cy-TEPC and the Cy-GPC was...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncx291

    authors: Forouzan F,Waker AJ

    更新日期:2018-08-01 00:00:00

  • Variations of soil radon concentrations along Chite fault in Aizawl district, Mizoram, India.

    abstract::The present study concerns measurements of radon emissions from soil carried out during March to July 2013 at Chite fault in Aizawl district, Mizoram, India. In this study, continuous radon monitoring in soil was done by using LR-115 type II nuclear track detector (Kodak-Pathe, France make), and the exposed films were...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncu221

    authors: Singh S,Jaishi H,Tiwari RP,Tiwari RC

    更新日期:2014-11-01 00:00:00

  • Electric and magnetic fields generated by ac power lines: an application of advanced modelling tools in order to predict exposure levels.

    abstract::In view of expected legislation changes imposing more severe limits on magnetic flux density, proposals are made based on theory and measurement for adjustment of Fower placement with regard to efficiency, cost and cost-benefit. ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006689

    authors: Manco D,Bruzzi L,Soloni A,Valbonetti D,Fabbri S,Violanti S

    更新日期:2001-01-01 00:00:00

  • Broadband Direct UVA irradiance measurement for clear skies evaluated using a smartphone.

    abstract::UVA wavelengths (320-400 nm) have been implicated in recent studies to contribute to melanoma induction and skin photoaging in humans and damage to plants. The use of smartphones in UVA observations is a way to supplement measurements made by traditional radiometric and spectroradiometric technology. Although the smar...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncu344

    authors: Igoe D,Parisi AV

    更新日期:2015-12-01 00:00:00

  • Neutron response of the chlorobenzene-ethanol-trimethylpentane dosimetry system.

    abstract::The dosimetric use of the chemical solution chlorobenzene-ethanol-trimethylpentane (CET) is based on the radiolytic formation of hydrochloric acid, which protonates a pH indicator thymolsulphonphthalein. On the basis of the CET solution, an accident and emergency personal dosemeter was designed allowing doses in the r...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm042

    authors: Miljanić S,Razem D

    更新日期:2007-01-01 00:00:00

  • Development and validation of a technique for the determination of 226Ra and 228Ra by liquid scintillation in liquid samples.

    abstract::Radium isotopes are dispersed in the environment according to their physicochemical characteristics. Considering their long half-lives and radiological effects, (226)Ra and (228)Ra are very important issues in radiological protection. In Brazil, radium isotopes represent an exposure problem both in nuclear fuel cycle ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq434

    authors: Fernandes PC,Sousa WO,Julião LM,Dantas BM

    更新日期:2011-03-01 00:00:00

  • INTERCAL: long-term inter-comparison experiment for dose rate and spectrometric probes.

    abstract::The Schauinsland inter-calibration facility (INTERCAL) has been designed to enable long-term comparison experiments for 20 different dose rate probes from different networks. Two reference probes characterised by the European Radiation Dosimetry WG3 inter-calibration experiments in 2008 and 2009 have been installed at...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncu039

    authors: Bleher M,Doll H,Harms W,Stöhlker U

    更新日期:2014-08-01 00:00:00

  • W values of protons in liquid water.

    abstract::The W values of protons in liquid water were calculated for energies from 0.1 keV to 10 MeV using the continuous slowing down approximation as well as three models for the calculation of the differential ionisation cross-sections of water for protons published in recent years. The W values determined by means of the t...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm019

    authors: Baek WY,Grosswendt B

    更新日期:2007-01-01 00:00:00

  • Measurement of the 250Cf component in a 252Cf neutron source at KRISS.

    abstract::Neutron emission rate measurements have been carried out at the Korea Research Institute of Standards and Science using a manganese sulphate bath system for (252)Cf and (241)Am-Be sources since 2004. The relative measurement method was chosen in 2012, and the neutron emission rates agreed with those by the absolute me...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nct327

    authors: Kim J,Park H,Choi KO

    更新日期:2014-10-01 00:00:00

  • Natural radioactivity levels in lake sediment samples.

    abstract::The radioactivity concentrations of nuclides (238)U, (232)Th and (40)K in lake sediments collected from 15 different stations at Altınkaya dam lake and 12 different stations at Derbent dam lake in Turkey were measured using high-resolution gamma-ray spectrometry. The measurement was done using a coaxial HPGe detector ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nct071

    authors: Eroğlu H,Kabadayi Ö

    更新日期:2013-09-01 00:00:00

  • Studies on internal exposure doses received by the cuban population due to the intake of radionuclides from the environmental sources.

    abstract::Studies for the determination of radionuclide concentrations in foodstuffs, water and air were carried out in Cuba for the estimation of annual committed effective doses to members of the public as a result of environmental radionuclides via ingestion and inhalation. As a result of these studies, it was possible to de...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncl002

    authors: Tomás Zerquera J,Prendes Alonso M,Fernández Gómez IM,Rodríguez Castro GV,Martínez Ricardo N,López Bejerano G,Ara do López JO,Acosta Rodríguez N,Carrazana González J,Brígido Flores O,Hernández Pérez A,Díaz Rizo O

    更新日期:2006-01-01 00:00:00

  • In vivo thermoluminescence dosimetry for total body irradiation.

    abstract::An improvement in the clinical results obtained using total body irradiation (TBI) with photon beams requires precise TBI treatment planning, reproducible irradiation, precise in vivo dosimetry, accurate documentation and careful evaluation. In vivo dosimetry using LiF Harshaw TLD-100 chips was used during the TBI tre...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006058

    authors: Palkosková P,Hlavata H,Dvorák P,Novotný J,Novotný J Jr

    更新日期:2002-01-01 00:00:00

  • Qualifying the use of RIS data for patient dose by comparison with DICOM header data.

    abstract::A system was developed in 2008 to calculate patient doses using Radiology Information System (RIS) data and presents these data as a patient dose audit. One of the issues with this system was the quality of user-entered data. It has been shown that Digital Imaging and Communication in Medicine (DICOM) header data can ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncr352

    authors: Wilde R,Charnock P,McDonald S,Moores BM

    更新日期:2011-09-01 00:00:00

  • Gamma-ray emitting test sources for Portal Monitors used for homeland security.

    abstract::The National Institute of Standards and Technology developed a new set of test sources for testing of portal monitors against the ANSI standard N42.35-2004. The design and source specifications are provided in this work. ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch422

    authors: Lucas L,Pibida L,Unterweger M,Karam L

    更新日期:2005-01-01 00:00:00

  • Reference dosimetry for light-ion beams based on graphite calorimetry.

    abstract::Developments in hadron therapy require efforts to improve the accuracy of the dose delivered to a target volume. Here, the determination of the absorbed dose under reference conditions was analysed. Based on the International Atomic Energy Agency TRS-398 code of practice, for hadron beams, the combined standard uncert...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nct299

    authors: Rossomme S,Palmans H,Thomas R,Lee N,Duane S,Bailey M,Shipley D,Bertrand D,Romano F,Cirrone P,Cuttone G,Vynckier S

    更新日期:2014-10-01 00:00:00

  • Neutron and photon fields in the BNCT room with closed beam shutters.

    abstract::The epithermal neutron beam at the LVR-15 reactor was designed for the Boron Neutron Capture Therapy (BNCT) of cancers, but it has also been used for material testing. In the case where the beam is closed with two designed shutters, there is still an indispensable background in the irradiation room, which limits the m...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci112

    authors: Marek M,Viererbl L

    更新日期:2005-01-01 00:00:00

  • Natural radioactivity intake into wheat grown on fertilized farms in two districts of Pakistan.

    abstract::The use of phosphate fertilizers on agricultural farms enhances gamma-ray activity concentration in the farms and therefore absorbed dose rates to the public. The most common natural radionuclides in fertilizer and soil are (40)K, (226)Ra and (232)Th. Agricultural farms at four locations in two districts in Pakistan c...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncl100

    authors: Nasim-Akhtar,Tufail M

    更新日期:2007-01-01 00:00:00

  • PRACTICAL METHODS FOR INTERNAL DOSE ASSESSMENT FOR RADIOIODINE INTAKE AFTER THYROID BLOCKING: CLASSIFICATION OF DEGREE OF BLOCKAGE AND DETERMINATION OF INSENSITIVE MEASUREMENT POINT.

    abstract::Iodine thyroid blocking (ITB) suppresses the uptake of iodine to the thyroid and reduces internal doses after radioiodine intake; however, its disturbance of thyroid biokinetics causes considerable uncertainty in the use of dosimetric data intended for assessment of unblocked normal thyroid. To more accurately assess ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncz139

    authors: Kwon TE,Park M,Jung GH,Chung Y,Ha WH,Jin YW

    更新日期:2019-12-31 00:00:00

  • EFFECTIVE INDOOR DOSE OF GAMMA RADIATION FROM BUILDING MATERIALS: COMPARISON OF SEVERAL METHODS FOR ESTIMATION AND POSSIBLE UNDERESTIMATE.

    abstract::This paper compares several methods for estimation of the effective indoor dose of gamma radiation from building materials. It was found that specific dose ratios proposed for 3 cm thick layers in one recommendation gives 2.8 times lower value of gamma dose than other methods. The most common case is that granite has ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncaa125

    authors: Krmar M,Milić K,Arsenić I,Hansman J

    更新日期:2020-10-16 00:00:00

  • An internal radiation dosimetry computer program, IDAC 2.0, for estimation of patient doses from radiopharmaceuticals.

    abstract::The internal dosimetry computer program internal dose assessment by computer (IDAC) for calculations of absorbed doses to organs and tissues as well as effective doses to patients from examinations with radiopharmaceuticals has been developed. The new version, IDAC2.0, incorporates the International Commission on Radi...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nct337

    authors: Andersson M,Johansson L,Minarik D,Mattsson S,Leide-Svegborn S

    更新日期:2014-12-01 00:00:00