Abstract:
:For an accurate determination of the absorbed doses in complex radiation fields (e.g. mixed neutron-gamma fields), a better interpretation of the response of ionisation chambers is required. This study investigates a model of the ionisation chambers using a different approach, analysing the collected charge per minute as a response of the detector instead of the dose. The MCNPX Monte Carlo code is used. In this paper, the model is validated using a well-known irradiation field only: a (60)Co source. The detailed MCNPX models of a Mg(Ar) and TE(TE) ionisation chamber is investigated comparing the measured charge per minute obtained free-in-air and in a water phantom with the simulated results. The difference between the calculations and the measurements for the TE(TE) chamber is within +/-2% whereas for the Mg(Ar) chamber is around +7%. The systematic discrepancy in the case of Mg(Ar) chamber is expected to be caused by an overestimation of the sensitive volume.
journal_name
Radiat Prot Dosimetryjournal_title
Radiation protection dosimetryauthors
Roca A,Nievaart VA,Moss RL,Stecher-Rasmussen F,Zamfir NVdoi
10.1093/rpd/ncm484subject
Has Abstractpub_date
2008-01-01 00:00:00pages
365-71issue
4eissn
0144-8420issn
1742-3406pii
ncm484journal_volume
129pub_type
杂志文章abstract::BNFL have over 25 years experience of designing nuclear plant for the whole-fuel cycle. In the UK, a Nuclear Decommissioning Authority (NDA) is to be set up to ensure that Britain's nuclear legacy is cleaned up safely, securely and cost effectively. The resulting challenges and opportunities for shielding design will ...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章,评审
doi:10.1093/rpd/nci171
更新日期:2005-01-01 00:00:00
abstract::The main objective of this comparative study was to evaluate the national quality assurance program for X-ray diagnostic radiology in Syrian governmental hospitals. Two periods were covered in this study, the first period was from 1986 to 1998 (52 hospitals and 149 X-ray machines were considered) and the second period...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncn096
更新日期:2008-01-01 00:00:00
abstract::The present work evaluates the per-procedure, annual collective and per-capita effective doses to the Aosta Valley region population from nuclear medicine (NM) examinations performed from 2005 to 2011 at the regional NM department. Based on its demographical and socioeconomics characteristics, this area can be conside...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/nct158
更新日期:2013-12-01 00:00:00
abstract::Detailed data relating to patient dose have been acquired for 18, randomly chosen, patients undergoing coronary angiographies. During the procedure, dose-area product (DAP), kV and beam collimation were recorded for each projection. Total DAP, fluoroscopy time and number of cine frames were also noted. Patient effecti...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/oxfordjournals.rpd.a006466
更新日期:2001-01-01 00:00:00
abstract::An oil and gas production facility in the western desert of Egypt was investigated for possible radiation risks due to the routine operation. Radium-226, Radium-228 and Potassium-40 were assessed in the soil samples collected from the adjacent soakaway pond. The average 226Ra, 228Ra and 40K activity concentrations wer...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncaa084
更新日期:2020-08-28 00:00:00
abstract::The electrochemical etching (ECE) method enlarges charged particle tracks to enhance its applications in particular in health physics and radiation dosimetry. The ECE method is usually based on using a high frequency-high voltage (HF-HV) generator with 250-µm-thick polycarbonate track detectors (PCTDs). The authors' r...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncu303
更新日期:2015-04-01 00:00:00
abstract::The question arises as to whether radiation standards and guidelines set for adults are sufficiently protective of children. To answer this question, published literature values have been used to calculate radiation doses to children and adults from external and internal exposure to a suite of 30 radionuclides commonl...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncq202
更新日期:2010-11-01 00:00:00
abstract::The neutron dose equivalent in aircraft is measured using commercial bubble detectors, but at high altitudes there are not only neutrons but also protons. Bubble detectors have been used because they are considered not to be sensitive to protons, but this has been the subject of only a few studies. In this study, by i...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/nch330
更新日期:2004-01-01 00:00:00
abstract::Virtual models of real phantoms used with Monte Carlo methods facilitate the calibration and other studies associated with whole-body and partial-body counting systems. In this investigation, a voxel model of an LLNL torso phantom, available physically in the in vivo laboratory at KIT, was created from computed tomogr...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncp030
更新日期:2009-02-01 00:00:00
abstract::Chips of a radiophotoluminescence glass dosemeter (RPLG) were used for measurements of space radiation during a 9.8 d Shuttle-Mir mission (STS-91) at an altitude of 400 km and an inclination of 51.65 degrees. Two of RPLG chips were put into each of 59 positions in or on a life-size human phantom. The RPLG values equiv...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/oxfordjournals.rpd.a005933
更新日期:2002-01-01 00:00:00
abstract::The use of a custom-made cylindrical graphite proportional counter (Cy-GPC) along with a cylindrical tissue equivalent proportional counter (TEPC) for neutron-gamma mixed-field dosimetry has been studied in the following steps: first, the consistency of the gamma dose measurement between the Cy-TEPC and the Cy-GPC was...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncx291
更新日期:2018-08-01 00:00:00
abstract::The present study concerns measurements of radon emissions from soil carried out during March to July 2013 at Chite fault in Aizawl district, Mizoram, India. In this study, continuous radon monitoring in soil was done by using LR-115 type II nuclear track detector (Kodak-Pathe, France make), and the exposed films were...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncu221
更新日期:2014-11-01 00:00:00
abstract::In view of expected legislation changes imposing more severe limits on magnetic flux density, proposals are made based on theory and measurement for adjustment of Fower placement with regard to efficiency, cost and cost-benefit. ...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/oxfordjournals.rpd.a006689
更新日期:2001-01-01 00:00:00
abstract::UVA wavelengths (320-400 nm) have been implicated in recent studies to contribute to melanoma induction and skin photoaging in humans and damage to plants. The use of smartphones in UVA observations is a way to supplement measurements made by traditional radiometric and spectroradiometric technology. Although the smar...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncu344
更新日期:2015-12-01 00:00:00
abstract::The dosimetric use of the chemical solution chlorobenzene-ethanol-trimethylpentane (CET) is based on the radiolytic formation of hydrochloric acid, which protonates a pH indicator thymolsulphonphthalein. On the basis of the CET solution, an accident and emergency personal dosemeter was designed allowing doses in the r...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncm042
更新日期:2007-01-01 00:00:00
abstract::Radium isotopes are dispersed in the environment according to their physicochemical characteristics. Considering their long half-lives and radiological effects, (226)Ra and (228)Ra are very important issues in radiological protection. In Brazil, radium isotopes represent an exposure problem both in nuclear fuel cycle ...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncq434
更新日期:2011-03-01 00:00:00
abstract::The Schauinsland inter-calibration facility (INTERCAL) has been designed to enable long-term comparison experiments for 20 different dose rate probes from different networks. Two reference probes characterised by the European Radiation Dosimetry WG3 inter-calibration experiments in 2008 and 2009 have been installed at...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncu039
更新日期:2014-08-01 00:00:00
abstract::The W values of protons in liquid water were calculated for energies from 0.1 keV to 10 MeV using the continuous slowing down approximation as well as three models for the calculation of the differential ionisation cross-sections of water for protons published in recent years. The W values determined by means of the t...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncm019
更新日期:2007-01-01 00:00:00
abstract::Neutron emission rate measurements have been carried out at the Korea Research Institute of Standards and Science using a manganese sulphate bath system for (252)Cf and (241)Am-Be sources since 2004. The relative measurement method was chosen in 2012, and the neutron emission rates agreed with those by the absolute me...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/nct327
更新日期:2014-10-01 00:00:00
abstract::The radioactivity concentrations of nuclides (238)U, (232)Th and (40)K in lake sediments collected from 15 different stations at Altınkaya dam lake and 12 different stations at Derbent dam lake in Turkey were measured using high-resolution gamma-ray spectrometry. The measurement was done using a coaxial HPGe detector ...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/nct071
更新日期:2013-09-01 00:00:00
abstract::Studies for the determination of radionuclide concentrations in foodstuffs, water and air were carried out in Cuba for the estimation of annual committed effective doses to members of the public as a result of environmental radionuclides via ingestion and inhalation. As a result of these studies, it was possible to de...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncl002
更新日期:2006-01-01 00:00:00
abstract::An improvement in the clinical results obtained using total body irradiation (TBI) with photon beams requires precise TBI treatment planning, reproducible irradiation, precise in vivo dosimetry, accurate documentation and careful evaluation. In vivo dosimetry using LiF Harshaw TLD-100 chips was used during the TBI tre...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/oxfordjournals.rpd.a006058
更新日期:2002-01-01 00:00:00
abstract::A system was developed in 2008 to calculate patient doses using Radiology Information System (RIS) data and presents these data as a patient dose audit. One of the issues with this system was the quality of user-entered data. It has been shown that Digital Imaging and Communication in Medicine (DICOM) header data can ...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncr352
更新日期:2011-09-01 00:00:00
abstract::The National Institute of Standards and Technology developed a new set of test sources for testing of portal monitors against the ANSI standard N42.35-2004. The design and source specifications are provided in this work. ...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/nch422
更新日期:2005-01-01 00:00:00
abstract::Developments in hadron therapy require efforts to improve the accuracy of the dose delivered to a target volume. Here, the determination of the absorbed dose under reference conditions was analysed. Based on the International Atomic Energy Agency TRS-398 code of practice, for hadron beams, the combined standard uncert...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/nct299
更新日期:2014-10-01 00:00:00
abstract::The epithermal neutron beam at the LVR-15 reactor was designed for the Boron Neutron Capture Therapy (BNCT) of cancers, but it has also been used for material testing. In the case where the beam is closed with two designed shutters, there is still an indispensable background in the irradiation room, which limits the m...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/nci112
更新日期:2005-01-01 00:00:00
abstract::The use of phosphate fertilizers on agricultural farms enhances gamma-ray activity concentration in the farms and therefore absorbed dose rates to the public. The most common natural radionuclides in fertilizer and soil are (40)K, (226)Ra and (232)Th. Agricultural farms at four locations in two districts in Pakistan c...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncl100
更新日期:2007-01-01 00:00:00
abstract::Iodine thyroid blocking (ITB) suppresses the uptake of iodine to the thyroid and reduces internal doses after radioiodine intake; however, its disturbance of thyroid biokinetics causes considerable uncertainty in the use of dosimetric data intended for assessment of unblocked normal thyroid. To more accurately assess ...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncz139
更新日期:2019-12-31 00:00:00
abstract::This paper compares several methods for estimation of the effective indoor dose of gamma radiation from building materials. It was found that specific dose ratios proposed for 3 cm thick layers in one recommendation gives 2.8 times lower value of gamma dose than other methods. The most common case is that granite has ...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncaa125
更新日期:2020-10-16 00:00:00
abstract::The internal dosimetry computer program internal dose assessment by computer (IDAC) for calculations of absorbed doses to organs and tissues as well as effective doses to patients from examinations with radiopharmaceuticals has been developed. The new version, IDAC2.0, incorporates the International Commission on Radi...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/nct337
更新日期:2014-12-01 00:00:00