Abstract:
:UVA wavelengths (320-400 nm) have been implicated in recent studies to contribute to melanoma induction and skin photoaging in humans and damage to plants. The use of smartphones in UVA observations is a way to supplement measurements made by traditional radiometric and spectroradiometric technology. Although the smartphone image sensor is not capable of determining broadband UVA irradiances, these can be reconstructed from narrowband irradiances, which the smartphone, with narrowband and neutral density filters, can quantify with discrepancies not exceeding 5 %. Three models that reconstruct direct broadband clear sky UVA were developed from narrowband irradiances derived from smartphone image sensor pixel data with coefficients of determination of between 0.97 and 0.99. Reasonable accuracy and precision in determining the direct broadband UVA was maintained for observations made with solar zenith angles as high as 70°. The developed method has the potential to increase the uptake of the measurement of broadband UVA irradiances.
journal_name
Radiat Prot Dosimetryjournal_title
Radiation protection dosimetryauthors
Igoe D,Parisi AVdoi
10.1093/rpd/ncu344subject
Has Abstractpub_date
2015-12-01 00:00:00pages
485-9issue
4eissn
0144-8420issn
1742-3406pii
ncu344journal_volume
167pub_type
杂志文章abstract::The HTR method, developed for determination of absorbed dose and average LET of mixed radiation fields in space, was applied during several space missions on space station MIR, space shuttles and satellites. The method utilises the changes of peak height ratios in the glow curves in dependence on the linear energy tra...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/oxfordjournals.rpd.a032854
更新日期:1999-01-01 00:00:00
abstract::There are approximately 20 caves of limestone origin in Zonguldak (Turkey). In this study, the results of atmospheric radon measurements performed for two caves are presented. These caves, Gökgöl and Cehennemağzi, are open to tourism. Gökgöl Cave is the longer, at nearly 3,200 m in length. Cehenennemağzi is a pit-type...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/nci326
更新日期:2006-01-01 00:00:00
abstract::Activity concentrations of dissolved (222)Rn and (226)Ra were measured in several underground aquifers, which are candidates for repositories or for the study of analogue natural escapes of CO2. The concentration of both radionuclides in water was determined using liquid scintillation counting. The values obtained for...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncv232
更新日期:2015-11-01 00:00:00
abstract::The amazing feature of ionising radiation (IR) as a DNA damaging agent is the range of lesions it induces. Such lesions include base damage, single strand breaks (SSBs), double strand breaks (DSBs) of varying complexity and DNA cross links. A range of DNA damage response mechanisms operate to help maintain genomic sta...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章,评审
doi:10.1093/rpd/ncl495
更新日期:2006-01-01 00:00:00
abstract::Values for the dose equivalent are required for radiation protection purposes, but determination of such values can be quite difficult for high energy radiations. The accurate determination of personal dose equivalents in accelerator radiation fields requires the propel use of appropriate radiological quantities and u...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章,评审
doi:10.1093/oxfordjournals.rpd.a006629
更新日期:2001-01-01 00:00:00
abstract::A new proposed design of neutron shielding material-based on the commercial material Borotron UH050 with an addition of Al(OH)3-is evaluated in order to determine if its neutron and gamma shielding properties match those of a reference material, NS4FR. Neutron and gamma dosimetry measurements are performed, as well as...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncx202
更新日期:2018-08-01 00:00:00
abstract::Following a radiological or nuclear emergency, first responders and the public may become internally contaminated with radioactive materials, as demonstrated during the Goiânia, Chernobyl and Fukushima accidents. Timely monitoring of the affected populations for potential internal contamination, assessment of radiatio...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncw199
更新日期:2016-09-01 00:00:00
abstract::After the Chernobyl reactor accident wide areas of Belarus were contaminated with radioactive fallout. The verification and documentation of the long-term development of radiation doses is still going on. A population group of special concern are the children living in contaminated regions. The annual dose limit of 1 ...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncm153
更新日期:2007-01-01 00:00:00
abstract::Costs related to the decommissioning of nuclear power plants create a significant financial burden for nuclear power plant operators. This article discusses the various methodologies employed by selected European countries for financing of the liabilities related to the nuclear power plant decommissioning. The article...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncv333
更新日期:2015-06-01 00:00:00
abstract::Swedish hemangioma patients were treated in infancy mainly by external application of radium-226 starting from 1920. This work analysed the radiation risk among 17,158 women with a total of 678 breast cancer incidence cases with models of carcinogenesis and empirical excess relative risk models. Models incorporating e...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncq473
更新日期:2011-02-01 00:00:00
abstract::Recent development of CaF2:Cu (the most sensitive material for radiation dosimetry) exhibiting a TL glow peak around 270 degrees C similar to that of CaF2:Mn has made it attractive to study the influence of heating rate on the response of CaF2 based TLDs. Influence of heating rate on CaF2:Mn (known to reduce the respo...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/oxfordjournals.rpd.a005870
更新日期:2002-01-01 00:00:00
abstract::Radiation accidents are fortunately infrequent occurrences, but since their consequences can be very serious as in the Chernobyl and the Fukushima nuclear accidents, medical management of radiation accidents is of great importance. Besides several other tasks, medical management of radiation accidents is one of the ke...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncs159
更新日期:2012-10-01 00:00:00
abstract::It has become increasingly evident from reports in the literature that there are many confounding factors capable of modulating radiation-induced non-targeted responses, such as the bystander effect and the adaptive response. In this paper, we examine recent data which suggest that the observation of non-targeted resp...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncq487
更新日期:2011-02-01 00:00:00
abstract::The enhancing effect due to long-time irrigation with radium-containing groundwater on soil was investigated in this work. Samples from the Al-Qassim and Hail areas in Saudi Arabia were studied for their 226Ra and 228Ra inventories. Groundwater and soil samples were collected from 32 farms where agricultural activitie...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncz287
更新日期:2020-06-24 00:00:00
abstract::The aim of the present study was to investigate of a possible correlation between indoor radon and indoor gamma dose rates deduced by in situ gamma spectrometry measurements by using a portable HPGe detector. Indoor radon and high resolution in situ gamma spectrometry measurements were performed in 60 apartments in Th...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/oxfordjournals.rpd.a006154
更新日期:2003-01-01 00:00:00
abstract::To evaluate the uncertainties for nuclear track detectors used in radon measurements, a full understanding is required of the physical phenomena involved and the behaviour of the instruments utilised in the measuring process. As it concerns the LR115 nuclear track detector, an overall evaluation of uncertainty was giv...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/nch361
更新日期:2004-01-01 00:00:00
abstract::Developments in hadron therapy require efforts to improve the accuracy of the dose delivered to a target volume. Here, the determination of the absorbed dose under reference conditions was analysed. Based on the International Atomic Energy Agency TRS-398 code of practice, for hadron beams, the combined standard uncert...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/nct299
更新日期:2014-10-01 00:00:00
abstract::Ionising radiation exposure of cells might induce the perturbation of cell functions and, in particular, the activation or inhibition of several important pathways. This perturbation can cause the deregulation of both intra- and extra-cellular signalling cascades (such as the inflammatory pathway) and alter not only t...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncv132
更新日期:2015-09-01 00:00:00
abstract::Experimental data on DNA double strand break (DSB) induction in human fibroblasts (AG1522), following irradiation with several radiation qualities, namely gamma rays, 0.84 MeV protons, 58.9 MeV u(-1) carbon ions, iron ions of 115 MeV u(-1), 414 MeV u(-1), 1 GeV u(-1), and 5 GeV u(-1), are presented. DSB yields were me...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncl389
更新日期:2006-01-01 00:00:00
abstract::The relation of radiation exposure (dose) with acute radiation syndrome (ARS) depends on many factors. In this overview, we reconsider (1) radiation exposure characteristics (e.g. radiation quality, fractionation, dose rate, partial/total body irradiation) and (2) biological processes (e.g. radiosensitivity, cell cycl...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncz058
更新日期:2019-12-31 00:00:00
abstract::All over the world geothermal sources are used for different purposes. The contents of these waters are important to understand positive/negative effects on human life. In this study, natural radioactivity concentrations of geothermal waters were investigated to evaluate the effect on soils and agricultural activities...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/nct220
更新日期:2014-01-01 00:00:00
abstract::At a high-energy, high-intensity proton accelerator facility, the accelerator components inside the beam-line tunnel and the concrete wall of the tunnel are activated due to beam loss during operation. During maintenance work inside the tunnel, radiation emitted from these activated materials can cause exposure to rad...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncl475
更新日期:2007-01-01 00:00:00
abstract::A 'moving-target' method for characterising background in a counting measurement in which the instantaneous background count rate is a function of time, rather than being fixed, is proposed. This model treats the average Poisson mean in observation period P as coming from a gamma distribution with parameters αP and βP...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncu297
更新日期:2015-04-01 00:00:00
abstract::The physical data regarding bremsstrahlung and neutrons produced in a steel shield by high-energy electron beams from a medical linear accelerator were investigated. These data are required to allow the accurate prediction of shielding performance for high-energy electron beams and in the design of radiotherapy facili...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncu153
更新日期:2015-02-01 00:00:00
abstract::The first proton linear accelerator for tumor therapy based on an actively scanned beam up to the energy of 150 MeV, is under development and construction by ENEA-Frascati, ISS and IFO, under the Italian TOP-IMPLART project. Protons up to the energy of 7 MeV are generated by a customized commercial injector operating ...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncy001
更新日期:2018-08-01 00:00:00
abstract::Cell storage in liquid nitrogen (LN) offers the most secure method of cell preservation even if cryopreserved cells are exposed to natural background of ionising radiation (IR). A lot of experiments have demonstrated that IR can induce damages in living cells, but only a little information regarding the response of cr...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncq541
更新日期:2011-02-01 00:00:00
abstract::The main objective of WP1 of the ORAMED (Optimization of RAdiation protection for MEDical staff) project is to obtain a set of standardised data on extremity and eye lens doses for staff in interventional radiology (IR) and cardiology (IC) and to optimise staff protection. A coordinated measurement program in differen...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncq508
更新日期:2011-03-01 00:00:00
abstract::The neural network method has been used for the unfolding of neutron spectra in neutron spectrometry by Bonner spheres. A back propagation algorithm was used for training of neural networks. 4 mm x 4 mm bare LiI (Eu) and in a polyethylene sphere set: 2, 3, 4, 5, 6, 7, 8, 10, 12, 18 inch diameter have been used for unf...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/oxfordjournals.rpd.a006158
更新日期:2003-01-01 00:00:00
abstract::The most used passive detectors for Radon measurement are the CR39s, both for the good stability of the material and for the practicality of use. But, commercial reading systems are expensive and not always fast. The aim of the present work was the development of a method for a rapid, efficient and economic evaluation...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncaa140
更新日期:2020-11-27 00:00:00
abstract::A novel neutron dose measurement method that flexibly responds to variations in the neutron field is being developed by Japan Atomic Energy Agency. This is an implementation of the multi-detector method (first introduced in 1960s) for neutron dose evaluation using a convex hull in the response space defined for multip...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncp134
更新日期:2009-08-01 00:00:00