Characterisation of non-constant background in counting measurements.

Abstract:

:A 'moving-target' method for characterising background in a counting measurement in which the instantaneous background count rate is a function of time, rather than being fixed, is proposed. This model treats the average Poisson mean in observation period P as coming from a gamma distribution with parameters αP and βP. This model is applied to a large dataset of replicate observations, consisting of 242 (234)U method blank measurements collected over a 2-y period. Point estimates of the model parameters are determined by comparing the mean and variance of the observed data and by maximising the likelihood function. Posterior distributions of the parameters are obtained by Markov Chain Monte Carlo. Assuming time-invariant fluctuations of the background count rate, the variation of the instantaneous count rate is described by a correlation function, which can be interpreted as describing how rapidly the background changes with time, or how likely the background is to change between measurements. An 'exponential-correlation' model of background time dependence is proposed, with parameters α, β and correlation time τ. Once determined, these parameters fully describe the distribution of background, just as NB and TB in the fixed-target model.

journal_name

Radiat Prot Dosimetry

authors

Klumpp J,Miller G,Brandl A

doi

10.1093/rpd/ncu297

subject

Has Abstract

pub_date

2015-04-01 00:00:00

pages

408-21

issue

3

eissn

0144-8420

issn

1742-3406

pii

ncu297

journal_volume

164

pub_type

杂志文章
  • No evidence for a low linear energy transfer adaptive response in irradiated RKO cells.

    abstract::It has become increasingly evident from reports in the literature that there are many confounding factors capable of modulating radiation-induced non-targeted responses, such as the bystander effect and the adaptive response. In this paper, we examine recent data which suggest that the observation of non-targeted resp...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq487

    authors: Sowa MB,Goetz W,Baulch JE,Lewis AJ,Morgan WF

    更新日期:2011-02-01 00:00:00

  • Usability of VTL from natural quartz grains for retrospective dosimetry.

    abstract::To develop retrospective dosimetry of unexpected radiation accident, basic studies on violet thermoluminescence (VTL) phenomena were conducted using natural quartz grains. All VTL glowcurves of as-received samples did not exhibit peaks <250 degrees C, although for artificially irradiated quartz samples there were VTL ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncl108

    authors: Fujita H,Hashimoto T

    更新日期:2007-01-01 00:00:00

  • How to prepare head tissue-equivalent liquids for SAR calculations, dosimetry and hyperthermia researches at 900 and 1800 MHz GSM frequencies.

    abstract::The potential harmful effect of electromagnetic fields on human health is an important issue that has been widely discussed in the scientific community. The investigation of temperature rise in human body following exposure to electromagnetic fields has been found impractical in many aspects. Therefore, fabrication of...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncv351

    authors: Sorgucu U,Develi I,Ozen S

    更新日期:2016-03-01 00:00:00

  • Determination of natural radioactivity in building materials used in Tunisian dwellings by gamma ray spectrometry.

    abstract::The radioisotopic content of 17 samples of natural and manufactured building materials collected in Tunisia have been analysed by using gamma spectrometry. From the measured gamma ray spectra, activity concentrations are determined for (232)Th, (226)Ra, (235)U and (40)K. The total effective dose and the activity conce...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch489

    authors: Hizem N,Ben Fredj A,Ghedira L

    更新日期:2005-01-01 00:00:00

  • Individual monitoring in mixed neutron/photon fields using a single silicon detector.

    abstract::A device based on a single silicon detector of special converter/detector design optimised for the determination of the neutron dose equivalent is also used for the determination of the photon dose equivalent. While the neutron dose is determined on the basis of signals corresponding to energy depositions above 1.5 Me...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a005962

    authors: Luszik-Bhadra M

    更新日期:2002-01-01 00:00:00

  • Validation of efficiency tracing and zero detection threshold techniques using liquid scintillation analyser TriCarb.

    abstract::Efficiency tracing with unquenched 14C and zero detection threshold with unquenched 3H as tracers are practical and simple techniques which have been implemented to quantify the activity of various beta emitters using liquid scintillation analyser. These techniques are used to study the influence of quench level on ac...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq495

    authors: Reddy PJ,Bhade SP,Babu DA,Sharma DN

    更新日期:2011-11-01 00:00:00

  • A large-scale measurement, analysis and modelling of electromagnetic radiation levels in the vicinity of GSM/UMTS base stations in an urban area.

    abstract::The present study analyses the electric field radiating from the GSM/UMTS base stations located in central Malatya, a densely populated urban area in Turkey. The authors have conducted both instant and continuous measurements of high-frequency electromagnetic fields throughout their research by using non-ionising radi...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncv008

    authors: Karadağ T,Yüceer M,Abbasov T

    更新日期:2016-01-01 00:00:00

  • Spatial distribution of indoor radon in Triveneto (Northern Italy): a geostatistical approach.

    abstract::The study of spatial distribution of the indoor radon has assumed in the last years a lot of interest. The geostatistical techniques turn out to be particularly promising. The present work presents the results of a study where around 4000 indoor radon data from Veneto, Friuli Venezia-Giulia and Alto Adige, collected d...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncp252

    authors: Bertolo A,Bigliotto C,Giovani C,Garavaglia M,Spinella M,Verdi L,Pegoretti S

    更新日期:2009-12-01 00:00:00

  • LUNG CANCER LIFETIME RISKS IN COHORT STUDIES OF URANIUM MINERS.

    abstract::The article summarizes the most recent results from the cohorts of uranium miners, particularly the risks at low exposures and the risk models with modifying effects of exposure rate, age and time since exposure, which are used for the calculation of lifetime risks (LRs). The excess relative risks per unit exposure (E...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncaa143

    authors: Tomasek L

    更新日期:2020-11-27 00:00:00

  • The present ICRP protection quantitites are seriously flawed. Opposing the proposition.

    abstract::Our debaters have agreed to defend positions that appear to be diametrically opposed; nevertheless, they have acknowledged some common ground. Although it was not explicitly stated, they would no doubt agree that workers and the public are adequately protected by our present system of radiation regulations. Our debate...

    journal_title:Radiation protection dosimetry

    pub_type: 评论,杂志文章

    doi:

    authors: Edwards AA

    更新日期:2003-01-01 00:00:00

  • LUMBAR SPINE RADIOGRAPHY: LOWER ORGAN DOSE WITH THE USE OF PA PROJECTION.

    abstract::The purpose of the research was to determine the effect of the posteroanterior (PA) patient position in lumbar spine imaging on effective dose and the absorbed organ dose. The study was performed on 100 patients that were referred to the lumbar spine radiography that were divided into two equal groups of 50. Body Mass...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncz057

    authors: Alukić E,Mekiš N

    更新日期:2019-12-31 00:00:00

  • Current status of radiological protection at nuclear power stations in Japan.

    abstract::The radiation dose to workers at nuclear power stations (NPSs) in Japan was drastically reduced between the late-1970s and the early-1990s by continuous dose-reduction programmes. The total collective dose of radiation workers in FY 2008 was 84.04 person Sv, while the average collective dose was 1.5 person Sv per reac...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncr185

    authors: Suzuki A,Hori S

    更新日期:2011-07-01 00:00:00

  • Sub-slab depressurisation systems used in the Czech Republic and verification of their efficiency.

    abstract::Design principles for sub-slab depressurisation systems recently used in the Czech Republic for remediating existing buildings are described. Results of an efficiency analysis performed on the basis of data from >60 single-family houses are presented. It was found out that the efficiency varies between 70 and 98 %, wh...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncu219

    authors: Jiránek M

    更新日期:2014-11-01 00:00:00

  • Radiation exposure for 'caregivers' during high-dose outpatient radioiodine therapy.

    abstract::On 27 occasions, radiation doses were measured for a family member designated as the 'caregiver' for a patient receiving high-dose radioiodine outpatient therapy for differentiated thyroid carcinoma. For 25 of the administrations, patients received 3.7 GBq of (131)I. Radiation doses for the designated caregivers were ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncl084

    authors: Marriott CJ,Webber CE,Gulenchyn KY

    更新日期:2007-01-01 00:00:00

  • Magnetic field tracking with MCNP5.

    abstract::With the introduction of continuous-energy heavy charged particle transport in MCNP5, the need for tracking charged particles in a magnetic field becomes increasingly important. Two methods for including magnetic field effects on charged particles are included in the proton transport version of the code. The first tec...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci048

    authors: Bul JS,Hughes HG,Walstrom PL,Zumbro JD,Mokhov NV

    更新日期:2005-01-01 00:00:00

  • Determination of 137Cs and 60Co pollution in the area of the Laguna Verde Nuclear Power Plant, Mexico.

    abstract::The project 'Radiological Analysis of Environmental Samples in the Gulf of Mexico and the coast of Quintana Roo', had the aim of identifying and quantifying anthropogenic radionuclides in environmental samples consisting of silt, sand and sea water. This paper presents the results of the radiological analysis of these...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncv250

    authors: Salas Mar B

    更新日期:2015-11-01 00:00:00

  • Relative radiological risks derived from different TENORM wastes in Malaysia.

    abstract::In Malaysia technologically enhanced naturally occurring radioactive materials (TENORM) wastes are mainly the product of the oil and gas industry and mineral processing. Among these TENORM wastes are tin tailing, tin slag, gypsum and oil sludge. Mineral processing and oil and gas industries produce large volume of TEN...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq577

    authors: Ismail B,Teng IL,Muhammad Samudi Y

    更新日期:2011-11-01 00:00:00

  • Comparison of a CCD and a flat-panel digital system in an Interventional Cardiology Laboratory.

    abstract::We evaluated the performances of angiographic units equipped with a flat-panel (FP) detector and image intensifier (II) charge-coupled device (CCD) in the Interventional Cardiology (IC) Department. Entrance dose rate and dose per image, along with the dose at the II level were measured using 2 mm copper sheets to simu...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci746

    authors: Tsapaki V,Kottou S,Kollaros N,Kyriakidis Z,Neofotistou V

    更新日期:2005-01-01 00:00:00

  • Discussion on optimisation below dose limit for public using background-cancer-risk-based approach.

    abstract::To improve a radiological protection system, the lower bound of optimisation was discussed using a newly proposed background-cancer-risk-based approach. This approach provides a new finding that the standard deviation of the background cancer risk in Japan is 7.4 × 10(-5) y(-1). If this risk level corresponding to 1σ ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncr150

    authors: Hattori T

    更新日期:2011-07-01 00:00:00

  • The influence of caesium-137 distribution in Poland's north-eastern ecosystem on effective dose 10 years after the Chernobyl disaster.

    abstract::A comparison is presented of particular methods of exposure in the first year after the Chernobyl disaster and ten years later. This comparison shows that the population exposure due to the presence of radiocaesium in the environment results from the presence of caesium contained in the soil, which provides 68% of the...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006725

    authors: Zalewski M,Kapala J,Tomczak M

    更新日期:2002-01-01 00:00:00

  • Comparison of various anthropomorphic phantom types for in vivo measurements by means of Monte Carlo simulations.

    abstract::Three widely used anthropomorphic phantoms are analysed with regard to their suitability for the efficiency calibration of whole-body counters (WBCs): a Bottle Manikin Absorber (BOMAB) phantom consisting of water-filled plastic containers, a St Petersburg block phantom (Research Institute of Sea Transport Hygiene, St ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq320

    authors: Schläger M

    更新日期:2011-03-01 00:00:00

  • Application of the ELDO approach to assess cumulative eye lens doses for interventional cardiologists.

    abstract::In preparation of a large European epidemiological study on the relation between eye lens dose and the occurrence of lens opacities, the European ELDO project focused on the development of practical methods to estimate retrospectively cumulative eye lens dose for interventional medical professionals exposed to radiati...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncu315

    authors: Farah J,Struelens L,Auvinen A,Jacob S,Koukorava C,Schnelzer M,Vanhavere F,Clairand I

    更新日期:2015-04-01 00:00:00

  • Time-integrated monitoring of thoron progeny concentration around closed uranium mine sites in Japan.

    abstract::Thoron progeny concentrations were determined using the time-integrated method around closed uranium mine sites in Japan. Because the time-integrated radon progeny monitor developed by the authors has the function to detect (212)Po, time-integrated monitoring of thoron progeny concentration is also available with the ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq242

    authors: Ishimori Y

    更新日期:2010-10-01 00:00:00

  • Dose trends in occupational radiation exposure in Europe results from the ESOREX project.

    abstract::The ESOREX project was initiated in 1997 by the EC DG TREN and it was executed by the BfS/Germany in close co-operation with the State Office for Nuclear Safety/Czech Republic). It consists of surveys on radiation monitoring and exposure carried out in the 30 European states. The study provides comparable descriptions...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncl566

    authors: Frasch G,Petrová K

    更新日期:2007-01-01 00:00:00

  • Patient dose in digital projection radiography.

    abstract::In projection radiography, two types of digital imaging systems are currently available, computed radiography (CR) and direct radiography (DR): a difference between them can be stated in terms of dose and image quality. In the Radiology Emergency Department of our hospital, a flat-panel DR equipment (Siemens Axiom Ari...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncn013

    authors: Compagnone G,Pagan L,Baleni MC,Calzolaio FL,Barozzi L,Bergamini C

    更新日期:2008-01-01 00:00:00

  • Keeping up with the neighbours--measuring the bystander response.

    abstract::Ionising radiation can induce responses within non-exposed neighbouring (bystander) cells, which potentially have important implications on the estimates of risk at environmentally relevant doses. Using human skin fibroblasts (AG1522), a range of methods were used to investigate the nature of the signal(s) arising fro...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncl430

    authors: Pyke EL,Stevens DL,Hill MA

    更新日期:2006-01-01 00:00:00

  • Defect complexes in Re3+-doped magnesium sulphate phosphors.

    abstract::A series of magnesium sulphate phosphors MgSO4:RE3+,X ( RE = Dy, Tm, Eu and X = P, Mn) have been prepared and studied. Based on the experimental results of thermoluminescence (TL) emission spectra and dose responses studies, it is proposed that in these phosphors large defect complexes are formed, which include intrin...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci680

    authors: Luo DL,Tang Q,Zhang CX

    更新日期:2006-01-01 00:00:00

  • Hp(3)/Φ conversion coefficients for neutrons: discussion on the basis of the new ICRP recommended limit for the eye lens.

    abstract::The new recommendation issued by the International Commission on Radiological Protection (ICRP) introducing a 20-mSv annual dose limit for the eye lens stimulated an interesting debate among the radiation protection community. In the present work the problem of estimating Hp(3) for neutron realistic workplace spectra ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nct246

    authors: Ferrari P,Gualdrini G,Tanner R,Fantuzzi E

    更新日期:2014-10-01 00:00:00

  • DYNAMIC RESPONSE OF CCD ARRAY SPECTRORADIOMETERS.

    abstract::A number of factors affect the measurements by charge coupled (CCD) array spectroradiometers, including stray light, dynamic response and ambient temperature. The departure from linearity was assessed for four CCD array spectroradiometers and linearity correction calculated with standard uncertainties error estimates....

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncv396

    authors: Baczynska KA,Price LL,Khazova M

    更新日期:2016-11-01 00:00:00

  • Natural radioactivity levels in lake sediment samples.

    abstract::The radioactivity concentrations of nuclides (238)U, (232)Th and (40)K in lake sediments collected from 15 different stations at Altınkaya dam lake and 12 different stations at Derbent dam lake in Turkey were measured using high-resolution gamma-ray spectrometry. The measurement was done using a coaxial HPGe detector ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nct071

    authors: Eroğlu H,Kabadayi Ö

    更新日期:2013-09-01 00:00:00