Defect complexes in Re3+-doped magnesium sulphate phosphors.

Abstract:

:A series of magnesium sulphate phosphors MgSO4:RE3+,X ( RE = Dy, Tm, Eu and X = P, Mn) have been prepared and studied. Based on the experimental results of thermoluminescence (TL) emission spectra and dose responses studies, it is proposed that in these phosphors large defect complexes are formed, which include intrinsic imperfections and dopants. These defect complexes were formed in the course of preparation of phosphors and could be regarded as basic elements in the TL multi-stage processes. This defect model might be applicable to the most of TL materials.

journal_name

Radiat Prot Dosimetry

authors

Luo DL,Tang Q,Zhang CX

doi

10.1093/rpd/nci680

subject

Has Abstract

pub_date

2006-01-01 00:00:00

pages

57-61

issue

1-4

eissn

0144-8420

issn

1742-3406

pii

nci680

journal_volume

119

pub_type

杂志文章
  • DOSE AREA PRODUCT VALUES OF FLUOROSCOPICALLY GUIDED PAIN MANAGEMENT PROCEDURES: COMPARISON OF A BELGIAN TEACHING HOSPITAL WITH NATIONAL DIAGNOSTIC REFERENCE LEVELS.

    abstract::In 2011, national diagnostic reference levels (DRLs) were proposed for pain management fluoroscopic procedures in Belgium. The primary goal of this work is to compare the dose area product values (DAP) recorded at the Saint-Luc University Hospital to these DRLs. From 2012 to 2015, 7664 interventional pain management p...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncx271

    authors: Hustinx N,Steyaert A,le Polain de Waroux B,Forget P

    更新日期:2018-05-01 00:00:00

  • Radiation safety assessment of a system of small reactors for distributed energy.

    abstract::A passively safe small reactor for a distributed energy system, PSRD, is an integral type of light-water reactor with a thermal output of 100 or 300 MW aimed to be used for supplying district heat, electricity to small grids, and so on. Candidate locations for the PSRD as a distributed energy source are on-ground, dee...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci208

    authors: Odano N,Ishida T

    更新日期:2005-01-01 00:00:00

  • Assessment of effective dose in paediatric CT examinations.

    abstract::Current concerns focus on the high doses encountered in computed tomography (CT) examinations as they are extending towards younger and more radiosensitive patients. Previous work produced conversion coefficients for effective dose (E) from dose-length product (DLP) for four anatomical body regions applicable to any p...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncr288

    authors: Dougeni E,Chapple CL,Willis J,Panayiotakis G

    更新日期:2011-09-01 00:00:00

  • Deposition of tritiated water vapour to water surface in an outdoor field.

    abstract::Deposition of tritiated water vapour in the atmosphere to a water surface was studied in an outdoor field, where elevated concentrations of tritiated water vapour existed in the atmosphere over twelve days. Exchange velocities of tritiated water vapour between air and water were evaluated from tritium concentrations i...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006425

    authors: Noguchi H,Fukutani S,Yokoyama S,Kinouchi N

    更新日期:2001-01-01 00:00:00

  • Managing Internal Radiation Contamination Following an Emergency: Identification of Gaps and Priorities.

    abstract::Following a radiological or nuclear emergency, first responders and the public may become internally contaminated with radioactive materials, as demonstrated during the Goiânia, Chernobyl and Fukushima accidents. Timely monitoring of the affected populations for potential internal contamination, assessment of radiatio...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncw199

    authors: Li C,Ansari A,Etherington G,Jourdain JR,Kukhta B,Kurihara O,Lopez MA,Ménétrier F,Alves Dos Reis A,Solomon S,Zhang J,Carr Z

    更新日期:2016-09-01 00:00:00

  • A theoretical study on accurate measurements of thoron with airflow-through scintillation cell method.

    abstract::For accurate measurements of (220)Rn concentration with airflow-through scintillation cell method, a theoretical study was performed for discussing the influences of sampling flow rate, volumes of sampling tube and scintillation cell on the measurements. It is found that a high flow rate and a large inner volume of sc...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq252

    authors: Tang F,Zhuo W,Zhao C,Chen B,Xu Y,He L

    更新日期:2010-10-01 00:00:00

  • Methods and materials for the measurement of subjective and objective measurements of image quality.

    abstract::The evaluation of medical imaging systems may be performed using both subjective (e.g. high contrast limiting resolution, and low contrast detail detectability), and objective/physical (e.g. characteristic curve, signal-to-noise ratio, modulation transfer function, and Wiener spectra) indices of image quality. For the...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006476

    authors: Marsh DM,Malone JF

    更新日期:2001-01-01 00:00:00

  • Determination of the dose to persons assisting when X-radiation is used in medicine, dentistry and veterinary medicine.

    abstract::During medical X-ray examinations of patients, humans as well as animals, voluntarily assisting persons are frequently needed in order to calm down the patient or animal. Typical exposure situations have been identified and measurements were performed in the fields of scattered X-rays. The personal dose equivalent H(p...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq351

    authors: Hupe O,Ankerhold U

    更新日期:2011-03-01 00:00:00

  • Can default ICRP f1 values be applied to determine radiation dose from the intake of diet-incorporated thorium?

    abstract::Data on the daily urinary excretion of thorium (Th) was obtained from 15 non-exposed adult German subjects. A radiochemical neutron activation analysis method was developed and standardised especially for this purpose. The daily urinary excretion of 232Th was found to be in the range 1.9-14.9 microBq d(-1) with a mean...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch482

    authors: Höllriegl V,Li WB,Oeh U,Röhmuss M,Roth P

    更新日期:2005-01-01 00:00:00

  • Radiation dose survey in a paediatric cardiac catheterisation laboratory equipped with flat-panel detectors.

    abstract::Flat-panel X-ray detectors for fluoroscopy represent a modern imaging equipment that is being implemented in paediatric cardiac catheterisation laboratories. Infants and children represent a group of patients with a high radiosensitivity. A survey of 273 (126 diagnostic and 147 therapeutic) paediatric catheterisations...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncn035

    authors: Dragusin O,Gewillig M,Desmet W,Smans K,Struelens L,Bosmans H

    更新日期:2008-01-01 00:00:00

  • An improved method for Organic Bound Tritium (OBT) determination in urine samples.

    abstract::The Organic Bound Tritium (OBT) amount in the body may induce changes in the evaluation of the internal exposure to tritium, due to its different retention time relative to HTO. OBT measurements for urine are not performed routinely, mainly because of the lengthy work needed in preparation of the samples, when using t...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm148

    authors: Gonen R,Marco R,German U,Katorza E,Alfassi ZB,Haquin G,Tshuva A,Pelled O

    更新日期:2007-01-01 00:00:00

  • Comparison of two extremity dosemeters based on LiF:Mg,Cu,P thin detectors for mixed beta-gamma fields.

    abstract::Two types of thin LiF:Mg,Cu,P detectors, GR-200F and MCP-Ns, have been characterised for use in the design of an extremity dosemeter for mixed beta-photon radiation fields. Both detectors consist of an extremely thin layer of sensitive material with effective thicknesses of 5 and 8 mg cm(-2), respectively, held in a 5...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci586

    authors: Ginjaume M,Pérez S,Ortega X,Duch MA

    更新日期:2006-01-01 00:00:00

  • Declassification of radioactive liquid wastes generated in radio immune assay [corrected] (RIA) laboratories.

    abstract::Radioactive liquid wastes of low-medium activity level are generated in radio immune assay (RIA) laboratories, which are also potentially infectious because of the pathogens from patient blood. The most common way of managing these wastes consists of a temporal storage, for partial radioactivity decay, followed by man...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci076

    authors: Sancho M,Arnal JM,Villaescusa JI,Campayo JM,Verdú G

    更新日期:2005-01-01 00:00:00

  • Levels of depleted uranium in Kosovo soils.

    abstract::The United Nations Environment Programme (UNEP) has performed a field survey at 11 sites located in Kosovo, where depleted uranium (DU) ammunitions were used by the North Atlantic Treaty Organization (NATO) during the last Balkans conflict (1999). Soil sampling was performed to assess the spread of DU ground contamina...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006679

    authors: Sansone U,Stellato L,Jia G,Rosamilia S,Gaudino S,Barbizzi S,Belli M

    更新日期:2001-01-01 00:00:00

  • A simple method to irradiate blood cells in vitro with radon gas.

    abstract::The design and dosimetry of a novel in vitro radon irradiation facility to investigate cytogenetic damage induced by radon and progeny is described. The system offers a 4pi geometry for uniform irradiation, proving a versatile and convenient facility for irradiation of whole blood cells in suspension or media. Doses c...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncn060

    authors: Hamza VZ,Kumar PR,Jeevanram RK,Santanam R,Danalaksmi B,Mohankumar MN

    更新日期:2008-01-01 00:00:00

  • Non-targeted effects of radiation: bystander responses in cell and tissue models.

    abstract::The standard paradigm for radiation effects in cellular systems has involved direct damage to DNA and in particular, DNA double strand breaks as the triggering lesions leading to mutation, cell death and transformation. Recently, however, a growing body of evidence has reported non-targeted effects, which are not a di...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006768

    authors: Prise KM,Belyakov OV,Newman HC,Patel S,Schettino G,Folkard M,Michael BD

    更新日期:2002-01-01 00:00:00

  • Development of an electrolysis system for tritium enrichment in superficial water samples.

    abstract::Tritium present in the environment gradually decreased in the last decades and nowadays it has reached extremely low activity concentrations. The purpose of the present work is the implementation of a tritium enrichment system in water samples using electrolytic techniques and pure nickel and iron electrodes. In the p...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncp244

    authors: Garbarino G,Magnoni M,Bertino S,Losana MC

    更新日期:2009-12-01 00:00:00

  • An overview on extremity dosimetry in medical applications.

    abstract::Some activities of EURADOS Working Group 9 (WG9) are presently funded by the European Commission (CONRAD project). The objective of WG9 is to promote and co-ordinate research activities for the assessment of occupational exposures to staff at workplaces in interventional radiology (IR) and nuclear medicine. For some o...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章,评审

    doi:10.1093/rpd/ncn149

    authors: Vanhavere F,Carinou E,Donadille L,Ginjaume M,Jankowski J,Rimpler A,Sans Merce M

    更新日期:2008-01-01 00:00:00

  • Analysis of computational problems expressing the overall uncertainties: photons, neutrons and electrons.

    abstract::In the frame of the EU Coordination Action CONRAD (coordinated network for radiation dosimetry), WP4 was dedicated to work on computational dosimetry with an action entitled 'Uncertainty assessment in computational dosimetry: an intercomparison of approaches'. Participants attempted one or more of eight problems. This...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncn221

    authors: de Carlan L,Price R,Chartier JL,Kodeli I,Siebert B,Henninger J,Posselt J,Gualdrini G,Agosteo S,Bedogni R,Bordy JM,Cassette P,Ferrari P,Gomez Ros JM,Grosswendt B,Lacoste V,Pola A,Rollet S,Schultz F,Simakov SP,Tanne

    更新日期:2008-01-01 00:00:00

  • ESTIMATION OF ORGAN DOSES AMONG DIAGNOSTIC MEDICAL RADIATION WORKERS IN SOUTH KOREA.

    abstract::This study aimed to estimate the radiation organ doses from occupational exposure in 94 396 Korean medical radiation workers. Data on badge doses (i.e. personal dose equivalent at 10 mm) between 1996 and 2011 obtained from a national dosimetry registry, survey data from 2012 to 2013, and organ dose conversion coeffici...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncx239

    authors: Choi Y,Shil Cha E,Jin Bang Y,Ko S,Ha M,Lee C,Jin Lee W

    更新日期:2018-04-01 00:00:00

  • Exposure estimates based on broadband ELF magnetic field measurements versus the ICNIRP multiple frequency rule.

    abstract::The evaluation of exposure to extremely low-frequency (ELF) magnetic fields using broadband measurement techniques gives satisfactory results when the field has essentially a single frequency. Nevertheless, magnetic fields are in most cases distorted by harmonic components. This work analyses the harmonic components o...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncu175

    authors: Paniagua JM,Rufo M,Jiménez A,Pachón FT,Carrero J

    更新日期:2015-02-01 00:00:00

  • A probabilistic safety analysis of incidents in nuclear research reactors.

    abstract::This work aims to evaluate the potential risks of incidents in nuclear research reactors. For its development, two databases of the International Atomic Energy Agency (IAEA) were used: the Research Reactor Data Base (RRDB) and the Incident Report System for Research Reactor (IRSRR). For this study, the probabilistic s...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncr387

    authors: Lopes VM,Agostinho Angelo Sordi GM,Moralles M,Filho TM

    更新日期:2012-06-01 00:00:00

  • Nodule detection in digital chest radiography: effect of anatomical noise.

    abstract::The image background resulting from imaged anatomy can be divided into those components that are meaningful to the observers, in the sense that they are recognised as separate structures, and those that are not. These latter components (reffered to as anatomical noise) can be removed using a method developed within th...

    journal_title:Radiation protection dosimetry

    pub_type: 临床试验,杂志文章

    doi:10.1093/rpd/nch526

    authors: Båth M,Håkansson M,Börjesson S,Hoeschen C,Tischenko O,Kheddache S,Vikgren J,Månsson LG

    更新日期:2005-01-01 00:00:00

  • THE GEOGENIC RADON POTENTIAL MAP OF THE ASPIRING 'BUZĂU LAND' GEOPARK.

    abstract::Mapping the geogenic radon potential in Buzău County is part of a research project aiming to apply research for sustainable development and economic growth following the principles of geoconservation in order to support the 'Buzău Land' UNESCO Geopark initiative. The mapping of geogenic radon will be used as an overvi...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncx143

    authors: Moldovan MC,Burghele BD,Roba CA,Sferle TL,Buterez C,Mitrofan H

    更新日期:2017-11-01 00:00:00

  • Induced radioactivity in the ESRF storage ring.

    abstract::The new French radiation protection legislation requires the definition of the zoning of accelerator facilities with respect to radioactive waste. This activation inside the ESRF 6 GeV storage ring is essentially due to photonuclear reactions. This paper describes the first results of Monte Carlo calculations that wer...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci070

    authors: Berkvens P

    更新日期:2005-01-01 00:00:00

  • Optimisation of the body composition analyser using the gamma shield and improvement of accuracy using ORNL anthropomorphic phantoms.

    abstract::The analysis of body elements using the prompt gamma rays neutron activation method is a very useful and highly accurate method Lone, M. A., Mughabghab, S. F. and Paviotti-Corcuera, R. Development of a database for prompt gamma-ray neutron activation analysis. Summary Report of the Second Research Coordination Meeting...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nct004

    authors: Araghian N,Rafat-Motavalli L,Miri-Hakimabad H

    更新日期:2013-07-01 00:00:00

  • Track structure for low energy ions including charge exchange processes.

    abstract::The model and development is described of a new generation of Monte Carlo track structure codes. The code LEPHIST simulates full slowing down of low-energy proton history tracks in the range 1 keV-1 MeV and the code LEAHIST simulates low-energy alpha particle history tracks in the range 1 keV-8 MeV in water. All prima...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006838

    authors: Uehara S,Nikjoo H

    更新日期:2002-01-01 00:00:00

  • Use of aspartame-based sweetener tablets in emergency dosimetry using EPR.

    abstract::Accident dosimetry aims to evaluate the unplanned radiation doses delivered to individuals through one of the objects exist in the area of the accident. The gamma dose response of free radicals generated in irradiated aspartame tablets and its usability for emergency dosimetry was studied. EPR spectra of unirradiated ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncp293

    authors: Maghraby A,Salama E

    更新日期:2010-06-01 00:00:00

  • THE CHALLENGE IN USING THE RETROSPECTIVE ASSESSMENT OF RESIDENTIAL RADON CONCENTRATION.

    abstract::In the present study, the contemporary indoor radon activity concentration and the surface-deposited 210Po activity were measured in 65 Romanian dwellings. The activity of trapped 210Po on the glass surface was measured using the (CR-LR) difference technique. The retrospective radon activity concentration estimated on...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncy095

    authors: Dicu T,Burghele BD,Lupulescu D,Cucos A

    更新日期:2018-09-01 00:00:00

  • A survey on uncertainty in bioassay measurements carried out within the OMINEX project.

    abstract::One of the topics covered by the OMINEX (Optimisation of Monitoring for Internal Exposure) project was to look at the bioassay measurements performed in the European laboratories. Questionnaires on bioassay measurements by alpha spectrometry or inductively coupled plasma-mass spectrometry (ICP-MS) were sent to Europea...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006261

    authors: Hurtgen C,Cossonnet C

    更新日期:2003-01-01 00:00:00