Abstract:
:The radiation dose to workers at nuclear power stations (NPSs) in Japan was drastically reduced between the late-1970s and the early-1990s by continuous dose-reduction programmes. The total collective dose of radiation workers in FY 2008 was 84.04 person Sv, while the average collective dose was 1.5 person Sv per reactor. The average annual individual dose was 1.1 mSv and the maximum annual individual dose was 19.5 mSv. These values are sufficiently lower than the regulatory dose limits. Radioactive effluent released from NPSs is already so trivial that additional protective measures will not be necessary. Experience in radiation protection at NPSs has been accumulated over 40 y and will be very useful in establishing a rational radiation control system in the future.
journal_name
Radiat Prot Dosimetryjournal_title
Radiation protection dosimetryauthors
Suzuki A,Hori Sdoi
10.1093/rpd/ncr185subject
Has Abstractpub_date
2011-07-01 00:00:00pages
343-6issue
1-3eissn
0144-8420issn
1742-3406pii
ncr185journal_volume
146pub_type
杂志文章abstract::A monolithic silicon telescope, consisting of a DeltaE and an E stage-detector ( approximately 1.9 microm and 500 microm thick, respectively), was coupled to a polyethylene converter in order to investigate the feasibility of a solid state microdosimeter with respect to the field-funnelling effect. This work discusses...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncl468
更新日期:2006-01-01 00:00:00
abstract::In this article, an approach to compute the dose conversion coefficients (DCCs) is described for the computational voxel phantom 'High-Definition Reference Korean-Man' (HDRK-Man) using artificial neural networks (ANN). For this purpose, the voxel phantom was implemented into the Monte Carlo (MC) transport toolkit GEAN...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncv436
更新日期:2016-12-01 00:00:00
abstract::Composite neutron scintillators consisting of neutron-insensitive fluorescent dopant particles (e.g. ZnS:Ag) embedded in a matrix material containing isotopes with high neutron cross sections that emit energetic charged particles (e.g. 6Li) are a popular method for neutron detection in a variety of applications. The s...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/nci121
更新日期:2005-01-01 00:00:00
abstract::The majority of the world's population relies on surface water or large public supply systems of groundwater, where radon is low and a guidance value for radon in drinking water is not necessary. However, the International Commission on Radiological Protection (ICRP) recently issued a dose coefficient for radon ingest...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncz035
更新日期:2019-12-31 00:00:00
abstract::The model and development is described of a new generation of Monte Carlo track structure codes. The code LEPHIST simulates full slowing down of low-energy proton history tracks in the range 1 keV-1 MeV and the code LEAHIST simulates low-energy alpha particle history tracks in the range 1 keV-8 MeV in water. All prima...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/oxfordjournals.rpd.a006838
更新日期:2002-01-01 00:00:00
abstract::CaSO4:Dy is a reliable high-sensitive themoluminescent phosphor useful for low-level and high-level radiation measurements as it exhibits fading free linear dose response with a single glow peak at ~230°C in these dose regions. For large-scale radiation protection dosimetry service, it is embedded in Teflon matrix wit...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章,评审
doi:10.1093/rpd/ncx287
更新日期:2018-10-01 00:00:00
abstract::This study identified occupational factors associated with radiation exposure in Korea. Survey data of 16 037 workers from 2016 to 2017, including lifestyle factors and occupational characteristics, were combined with the National Dose Registry. Higher average annual doses were observed in groups exhibiting health ris...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncaa019
更新日期:2020-07-07 00:00:00
abstract::Deposition of tritiated water vapour in the atmosphere to a water surface was studied in an outdoor field, where elevated concentrations of tritiated water vapour existed in the atmosphere over twelve days. Exchange velocities of tritiated water vapour between air and water were evaluated from tritium concentrations i...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/oxfordjournals.rpd.a006425
更新日期:2001-01-01 00:00:00
abstract::A new official albedo dosemeter based on thermoluminescent detectors has been introduced in 2015 by the individual monitoring service of the Helmholtz Zentrum München for monitoring persons who are exposed occupationally against photon and neutron radiation. To enhance the sensitivity for fast neutrons, a new badge wi...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncv406
更新日期:2016-09-01 00:00:00
abstract::EURADOS working group on 'Internal Dosimetry (WG7)' represents a frame to develop activities in the field of internal exposures as coordinated actions on quality assurance (QA), research and training. The main tasks to carry out are the update of the IDEAS Guidelines as a reference document for the internal dosimetry ...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncq435
更新日期:2011-03-01 00:00:00
abstract::Some areas of the world, called high background radiation areas (HBRAs), have anomalously high levels of natural background radiation and the population residing in the areas is exposed to higher levels of radiation doses than other parts of the world where the natural radioactivity contents are normal. In the present...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncr399
更新日期:2012-07-01 00:00:00
abstract::To assess the frequency of examination, image quality (IQ) and establishment of local diagnostic reference levels (LDRLs) in paediatric radiographic examinations. The X-ray device performance, film reject rate and IQ grading were assessed at Radiology Department of a referral and teaching children's hospital in Kenya....
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncs270
更新日期:2013-05-01 00:00:00
abstract::The availability of active neutron personal dosemeters has made real time monitoring of neutron doses possible. This has obvious benefits, but is only of any real assistance if the dose assessments made are of sufficient accuracy and reliability. Preliminary assessments of the performance of active neutron dosemeters ...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncm095
更新日期:2007-01-01 00:00:00
abstract::Spinal deformities affect young individuals predominantly girls who are usually subjected to regular and intensive radiological investigation especially before and after corrective surgery. Optimisation of spine computed tomography (CT) and the implementation of the low-dose CT in the work-up of spinal deformities wer...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncp306
更新日期:2010-04-01 00:00:00
abstract::Rapid administration of stable iodine is essential for the saturation and subsequent protection of the thyroid gland against the potential harm caused by radioiodines. This paper proposes the Dutch risk analysis that uses an atmospheric dispersion model to calculate the size of the zones around nuclear power plants wh...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncq114
更新日期:2010-08-01 00:00:00
abstract::Some data were derived using recent sophisticated methods to rapidly convert specific activity of induced 24Na to average dose over a whole body in criticality accidents. Monte Carlo calculations using the MCNP-4B code were performed to study energy spectra of neutrons and gamma rays for some criticality systems with ...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/oxfordjournals.rpd.a006350
更新日期:2003-01-01 00:00:00
abstract::An automatic measuring apparatus called exhalometer for measurement of the radon exhalation rate from soil is introduced. It consists of a pneumatic driven accumulation chamber with an open bottom, a PC-based control system, six Lucas cells for radon measurement and sensors for environmental parameters. It allows movi...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncx165
更新日期:2017-11-01 00:00:00
abstract::Because the doses received on-board aeroplanes are now monitored to fulfil legal requirements in some countries, including the European Community, the models to calculate doses received during solar events have left their purely academic status to become a part of operational systems as well. The present work consider...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/nci356
更新日期:2006-01-01 00:00:00
abstract::Radiation particles, besides their application to fundamental research, are widely applied in all fields of science (medicine, material science, chemistry, etc.). Up to today the radiations were produced by radiation sources such as accelerators, X-ray tubes, radioactive sources with the well-known problems of costs, ...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncr239
更新日期:2011-07-01 00:00:00
abstract::To assess occupational exposure to electromagnetic fields, 11 microwave (MW), 4 short-wave diathermy and 15 magneto therapy devices were analysed in eight physiotherapy departments. Measurements taken at consoles and environmental mapping showed values above European Directive 2004/40/EC and ACGIH exposure limits at a...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncm309
更新日期:2008-01-01 00:00:00
abstract::GSI is operating a facility for the production of rare isotopes. Nuclei are produced by fragmentation or fission of the impinging heavy ions with energies of approximately 1 GeV per nucleon. The major part of the primary beam and the produced nuclei is deposited in the components of the Fragment Separator (FRS) and ge...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/nch210
更新日期:2004-01-01 00:00:00
abstract::In the light of a growing awareness of the risks of inducing skin injuries as a consequence of fluoroscopically guided interventional procedures (FGIPs), this paper reports measurements of ESDs made during the period August 1998 to June 1999 on 137 patients undergoing cardiac, neurological and general FGIPs in the Sou...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/oxfordjournals.rpd.a006486
更新日期:2001-01-01 00:00:00
abstract::Internal contamination due to high-energy photon (HEP) emitters is assessed using a scanning bed whole-body monitor housed in a steel room at the Bhabha Atomic Research Centre (BARC). The monitor consists of a (203 mm diameter × 102 mm thickness) NaI(Tl) detector and is calibrated using a Reference BOMAB phantom repre...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncr203
更新日期:2012-03-01 00:00:00
abstract::The newsletter 'European Research in Radiological Sciences' is jointly published by the European Late Effects Project Group and the European Radiation Dosimetry Group to disseminate information about research projects and activities carried out under the EURATOM Framework Programme. Since May 2003, the Newsletter is o...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/nch095
更新日期:2004-01-01 00:00:00
abstract::A secondary standard ionisation chamber for photon radiation for measuring an ionisation current, which is directly proportional to the conventionally true value of the ambient dose equivalent, H*(10), was optimised. The chamber was developed in the Austrian Research Centers Seibersdorf and is used successfully worldw...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/nci334
更新日期:2006-01-01 00:00:00
abstract::Relatively high organ doses absorbed by patients in interventional cardiology suggest the opportunity to define these patients as a cohort to be followed forward in time in an epidemiological study of the cancer risks associated with exposure to low-dose ionising radiation. In this paper, the UNSCEAR 2000 Report risk ...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章,评审
doi:10.1093/rpd/ncn036
更新日期:2008-01-01 00:00:00
abstract::Simultaneous indoor radon, radon-thoron progeny and high-resolution in situ gamma spectrometry measurements, with portable high-purity Ge detector were performed in 26 dwellings of Thessaloniki, the second largest town of Greece, during March 2003-January 2005. The radon gas was measured with an AlphaGUARD ionisation ...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/nci366
更新日期:2006-01-01 00:00:00
abstract::Digital breast tomosynthesis is a new three-dimensional (3D) breast-imaging modality that produces images of cross-sectional planes parallel to the detector plane from a limited number of X-ray projections over a limited angular range. Several technical and clinical parameters have not yet been completely optimised. S...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncq084
更新日期:2010-04-01 00:00:00
abstract::Between 1952 and 1957, the UK exploded a total of 12 nuclear devices in Australia, and also conducted about 600 'minor trials' that did not involve a nuclear explosion. Over 16 000 Australian servicemen and civilians were involved in the UK tests in Australia. This paper reports the estimation of doses that the Austra...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncp164
更新日期:2009-09-01 00:00:00
abstract::Thermoluminescence (TL) dose responses to gamma radiation in the dose range from 0.1 Gy to 20 kGy in MgSO4:Dy, MgSO4:Dy,Mn, MgSO4:Dy,P and MgSO4:Dy,P,Cu phosphors were obtained and fitted by the composite action dose response function to obtain non-linear characteristic parameters, one-hit factor R and characteristic ...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/oxfordjournals.rpd.a005824
更新日期:2002-01-01 00:00:00