Abstract:
:The model and development is described of a new generation of Monte Carlo track structure codes. The code LEPHIST simulates full slowing down of low-energy proton history tracks in the range 1 keV-1 MeV and the code LEAHIST simulates low-energy alpha particle history tracks in the range 1 keV-8 MeV in water. All primary ion interactions are followed down to 1 keV and all electrons to 1 eV. Tracks of secondary electrons ejected by ions were traced using the electron code KURBUC. Microdosimetric parameters derived by analysis of generated tracks are presented.
journal_name
Radiat Prot Dosimetryjournal_title
Radiation protection dosimetryauthors
Uehara S,Nikjoo Hdoi
10.1093/oxfordjournals.rpd.a006838keywords:
subject
Has Abstractpub_date
2002-01-01 00:00:00pages
53-5issue
1-4eissn
0144-8420issn
1742-3406journal_volume
99pub_type
杂志文章abstract::238U, 234U and 235U were determined in tap water from municipal water pipes that drew their supply from surface water or ground water in various locations in Poland. Average activity concentrations of 238U, 234U and 235U in tap water from surface water were 9.6 +/- 7.1, 12.8 +/- 9.7 and 0.41 +/- 0.31 Bq m(-3), respect...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/nch425
更新日期:2005-01-01 00:00:00
abstract::Dose conversions were studied for dosimetry of atomic bomb survivors based upon electron spin resonance (ESR) measurements of tooth enamel. Previously analysed data had clarified that the tooth enamel dose could be much larger than other organ doses from a low-energy photon exposure. The radiation doses to other organ...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncr408
更新日期:2012-03-01 00:00:00
abstract::This study presents the results of 222Rn in 24 sources of mineral water, 54 samples from different captured natural springs and drillings. 222Rn determination was performed by direct measurement using Alpha Guard with Aqua Kit. The results for the TDS, anions (F-, Cl-, SO42-), cations (Na+, Ca2+, Mg2+), pH and tempera...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncy089
更新日期:2018-09-01 00:00:00
abstract::This paper presents the finding of a study undertaken to determine natural radioactivity and associated hazards in local types of cement in Iran. A total of 42 samples were collected from various manufacturers and suppliers and analysed using a shielded HPGe gamma-ray spectrometer. The specific activities of 232Th, 22...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncl549
更新日期:2007-01-01 00:00:00
abstract::Is atmospheric dispersion forecasting an important asset of the early-phase nuclear emergency response management? Is there a 'perfect atmospheric dispersion model'? Is there a way to make the results of dispersion models more reliable and trustworthy? While seeking to answer these questions the multi-model ensemble d...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/nch261
更新日期:2004-01-01 00:00:00
abstract::When neutron survey metres are calibrated in neutron fields, the results for room- and air-scattered neutrons vary according to the distance from the source and the size, shape and construction of the neutron calibration room. ISO 8529-2 recommends four approaches for correcting these effects: the shadow-cone method, ...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncx219
更新日期:2018-08-01 00:00:00
abstract::The aim of the study was to estimate organ dose rate reduction to a female anthropomorphic phantom, which simulated the cardiologist, during percutaneous coronary interventions (PCI) when the patient's arm support was covered with 0.4-mm lead foil. Organ dose rates were determined using five radiation detectors insert...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncz292
更新日期:2020-06-24 00:00:00
abstract::The new recommendation issued by the International Commission on Radiological Protection (ICRP) introducing a 20-mSv annual dose limit for the eye lens stimulated an interesting debate among the radiation protection community. In the present work the problem of estimating Hp(3) for neutron realistic workplace spectra ...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/nct246
更新日期:2014-10-01 00:00:00
abstract::The dosimetric technique described in this paper is based on electron spin resonance (ESR) detectors using an alanine-boric compound acid enriched with (10)B, and beryllium oxide thermoluminescent (TL) detectors; with this combined dosimetry, it is possible to discriminate the doses due to thermal neutrons and gamma r...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/nch110
更新日期:2004-01-01 00:00:00
abstract::From feedback experience from recent radiation accident cases, in addition to biological dosimetry and physical dosimetry based on Monte Carlo calculations or experimental means, there is a need for complementary methods of dosimetry for radiation accident. Electron paramagnetic resonance (EPR) spectrometry on bones o...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章,评审
doi:10.1093/rpd/ncq341
更新日期:2011-03-01 00:00:00
abstract::An investigation of the simultaneous unfolding of data from neutron spectrometers using the UMG codes MAXED and GRAVEL has been performed. This approach involves combining the data from the spectrometers before unfolding, thereby performing a single combined unfolding of all the data to yield a final combined spectrum...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncm082
更新日期:2007-01-01 00:00:00
abstract::International Electrotechnical Commission (IEC) established the framework for the use of exposure index (EI) for evaluating the exposure conditions with various digital systems. In this study, we investigated the feasibility of EI, as per the IEC, by comparing the EIs obtained through manual calculated and that displa...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncaa052
更新日期:2020-07-17 00:00:00
abstract::To evaluate the uncertainties for nuclear track detectors used in radon measurements, a full understanding is required of the physical phenomena involved and the behaviour of the instruments utilised in the measuring process. As it concerns the LR115 nuclear track detector, an overall evaluation of uncertainty was giv...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/nch361
更新日期:2004-01-01 00:00:00
abstract::To assess occupational exposure to electromagnetic fields, 11 microwave (MW), 4 short-wave diathermy and 15 magneto therapy devices were analysed in eight physiotherapy departments. Measurements taken at consoles and environmental mapping showed values above European Directive 2004/40/EC and ACGIH exposure limits at a...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncm309
更新日期:2008-01-01 00:00:00
abstract::This study aims to review the literature on existing diagnostic reference levels (DRLs) in digital mammography and methodologies for establishing them. To this end, a systematic search through Medline, Cinahl, Web of Science, Scopus and Google scholar was conducted using search terms extracted from three terms: DRLs, ...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章,评审
doi:10.1093/rpd/ncu365
更新日期:2015-12-01 00:00:00
abstract::A widely used method in the planning of protective actions is to establish a stakeholder network to generate a comprehensive set of generic protective actions. The aim is to increase competence and build links for communication and coordination. The approach of this work was to systematically evaluate protective actio...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/nch258
更新日期:2004-01-01 00:00:00
abstract::A new passive integral dosemeter for gamma ray monitoring is being developed using an imaging plate (IP). In the application of IPs to dosimetry, a fading effect causes serious problems. The fading is considered to be caused by the recombination or holes and charges trapped shallowly in the F centres, which have sever...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/oxfordjournals.rpd.a006396
更新日期:2003-01-01 00:00:00
abstract::Calcium fluoride CaF2 is an interesting host lattice for rare earth (RE) activators. CaF2 crystals doped with different concentrations of Dy, Ce, Er and Gd have been grown by the Bridgman technique and their deformation luminescence (DL) induced by room temperature gamma irradiation has been recorded. When a uniaxial ...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/nci606
更新日期:2006-01-01 00:00:00
abstract::Monitoring of occupationally exposed persons in Bosnia and Herzegovina started in 1960s and it was interrupted in 1992. Dosimetry service resumed in 1999 when the International Atomic Energy Agency provided Harshaw 4500 TLD-reader and the first set of TLDs for the Radiation Protection Centre (RPC) of the Institute of ...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncq006
更新日期:2010-04-01 00:00:00
abstract::An automatic measuring apparatus called exhalometer for measurement of the radon exhalation rate from soil is introduced. It consists of a pneumatic driven accumulation chamber with an open bottom, a PC-based control system, six Lucas cells for radon measurement and sensors for environmental parameters. It allows movi...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncx165
更新日期:2017-11-01 00:00:00
abstract::Exposure of children to ionising radiation is considered to carry higher risk than that of adults; therefore a need to suggest diagnostic reference levels (DRLs) for the common paediatric diagnostic X-ray procedures was recognised for the X-ray machines meeting the requirements of the recently implemented Safety Code ...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncq458
更新日期:2011-11-01 00:00:00
abstract::A new procedure allowing the separate estimation of neutron and gamma dose in mixed radiation fields has been developed in our laboratory. In this communication, a description of the main features of the discrimination procedure and some preliminary results obtained by its use are presented. The procedure is based on ...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncm210
更新日期:2007-01-01 00:00:00
abstract::The connection between recorded volumetric CT dose index (CTDI vol) and determined mean fetal dose (Df) was examined from metal-oxide-semiconductor field-effect transistor dose measurements on an anthropomorphic female phantom in four stages of pregnancy in a 64-slice CT scanner. Automated tube current modulation kept...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncv097
更新日期:2015-07-01 00:00:00
abstract::Magnetic resonance imaging (MRI) is one of the most common sources of electromagnetic (EM) fields as a diagnostic technique widely used in medicine. MRI staff during the working day is constantly exposed to static and spatially heterogeneous magnetic field. Also, moving around the MRI room to perform their functions, ...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncy114
更新日期:2018-12-01 00:00:00
abstract::The majority of the world's population relies on surface water or large public supply systems of groundwater, where radon is low and a guidance value for radon in drinking water is not necessary. However, the International Commission on Radiological Protection (ICRP) recently issued a dose coefficient for radon ingest...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncz035
更新日期:2019-12-31 00:00:00
abstract::The influence of 10 MeV high-current electron beams accelerated by the M-30 microtron on the luminescent properties of the α-Al₂O₃, Al₂O₃:Nb and Al₂O₃:Fe crystals has been studied. The effect of the long-term phosphorescence at room temperature has been found that can be used to monitor electron and gamma accelerator ...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncu213
更新日期:2014-11-01 00:00:00
abstract::The observation of anomalies in the radon concentration in soil gas and ground water before earthquakes initiated systematic investigations on earthquake precursor phenomena. The question what is needed for a meaningful earthquake prediction as well as what types of precursory effects can be expected is shortly discus...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncr229
更新日期:2012-04-01 00:00:00
abstract::The analysis of body elements using the prompt gamma rays neutron activation method is a very useful and highly accurate method Lone, M. A., Mughabghab, S. F. and Paviotti-Corcuera, R. Development of a database for prompt gamma-ray neutron activation analysis. Summary Report of the Second Research Coordination Meeting...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/nct004
更新日期:2013-07-01 00:00:00
abstract::The current focus on networking and mutual assistance in the management of radiation accidents or incidents has demonstrated the importance of a joined-up approach in physical and biological dosimetry. To this end, the European Radiation Dosimetry Working Group 10 on 'Retrospective Dosimetry' has been set up by indivi...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章,评审
doi:10.1093/rpd/ncq499
更新日期:2011-11-01 00:00:00
abstract::Improved radiation protection of humans requires a better understanding of the mechanisms of radiation action and accurate estimates of radiation risk for both internal and external radiations. The Japanese atomic bomb survivors represent one of the most important sources of human data on the late carcinogenic effects...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/oxfordjournals.rpd.a006532
更新日期:2001-01-01 00:00:00