Indoor radon and thoron levels in Neendakara and Chavara regions of southern coastal Kerala, India.

Abstract:

:Some areas of the world, called high background radiation areas (HBRAs), have anomalously high levels of natural background radiation and the population residing in the areas is exposed to higher levels of radiation doses than other parts of the world where the natural radioactivity contents are normal. In the present investigation, levels of radon, thoron and their progeny are studied in 110 houses in the coastal region of the Kollam district in the state of Kerala, India using the multi-detector twin cup dosimeter. Among these, 10 houses were studied in detail with five dosimeters in each house. Radon activity concentrations were found to vary from 7 to 100 Bqm(-3) and that of thoron from 4 to 66 Bqm(-3) in Neendakara panchayat. In Chavara panchayat, the variations of radon concentrations were from 7 to 83 Bqm(-3) and thoron concentrations were varied from 4 to 86 Bqm(-3). The occurrence of radon and thoron concentrations in the dwellings for both study areas shows that in 50% of the dwellings, the concentration of radon is about 25 Bqm(-3) and in 60% of the dwellings thoron concentration is about 15 Bqm(-3). The ratio of thoron-to-radon concentrations in the dwellings showed a mean value 0.55 (GM=0.45) for the region.

journal_name

Radiat Prot Dosimetry

authors

Pereira CE,Vaidyan VK,Chougaonkar MP,Mayya YS,Sahoo BK,Jojo PJ

doi

10.1093/rpd/ncr399

subject

Has Abstract

pub_date

2012-07-01 00:00:00

pages

385-90

issue

3

eissn

0144-8420

issn

1742-3406

pii

ncr399

journal_volume

150

pub_type

杂志文章
  • Activity concentrations and mean annual effective dose from gamma-emitting radionuclides in the Lebanese diet.

    abstract::Since the primary factor contributing to the internal effective dose in the human organism is contaminated food, the control of radionuclides in food represents the most important means of protection. This study was conducted to determine the levels of the dietary exposure of the Lebanese population to gamma-emitting ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncn160

    authors: Nasreddine L,El Samad O,Hwalla N,Baydoun R,Hamzé M,Parent-Massin D

    更新日期:2008-01-01 00:00:00

  • Stability of A-150 plastic ionisation chamber response over a approximately 30-y period.

    abstract::At the Northern Illinois University Institute for Neutron Therapy at Fermilab, the clinical tissue-equivalent ionisation chamber response is measured every treatment day using a cesium source that was configured to match readings obtained at the National Bureau of Standards. Daily measurements are performed in air usi...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm126

    authors: Kroc TK,Lennox AJ

    更新日期:2007-01-01 00:00:00

  • Mammography dose in relation to body mass index, race, and menopausal status.

    abstract::Mammography dose increases with compressed breast thickness (CBT), but few studies have examined other correlates of dose. The purpose of this study was to evaluate the relation between factors such as race, age, body mass index (BMI), CBT, and menopausal status and mammography screening dose, measured for 509 women i...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006733

    authors: Schubauer-Berigan MK,Frey GD,Baron L,Hoel DG

    更新日期:2002-01-01 00:00:00

  • Local diagnostic reference levels in standard X-ray examinations.

    abstract::The national diagnostic reference levels (NDRLs) form an efficient, concise and powerful standard for optimising radiation protection of a patient. However, in a large hospital, where many radiological departments are present, it is also possible to calculate and define lower dose values as local diagnostic reference ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch432

    authors: Compagnone G,Pagan L,Bergamini C

    更新日期:2005-01-01 00:00:00

  • ITERATIVE SCATTER CORRECTION FOR GRID-LESS BEDSIDE CHEST RADIOGRAPHY: PERFORMANCE FOR A CHEST PHANTOM.

    abstract::The aim of this work was to experimentally compare the contrast improvement factors (CIFs) of a newly developed software-based scatter correction to the CIFs achieved by an antiscatter grid. To this end, three aluminium discs were placed in the lung, the retrocardial and the abdominal areas of a thorax phantom, and di...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncv432

    authors: Mentrup D,Jockel S,Menser B,Neitzel U

    更新日期:2016-06-01 00:00:00

  • Internal dose assessment in radiation accidents.

    abstract::Although numerous models have been developed for occupational and medical internal dosimetry, they may not be applicable to an accident situation. Published dose coefficients relate effective dose to intake, but if acute deterministic effects are possible, effective dose is not a useful parameter. Consequently, dose r...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006250

    authors: Toohey RE

    更新日期:2003-01-01 00:00:00

  • Head calibration phantoms for actinides: measurements and simulations.

    abstract::The paper deals with the physical skull phantoms Bundesinstitut fuer Strahlenschutz and BPAM-001, which are used in order to calibrate in vivo detection systems for estimation of (241)Am activity in the skeleton. Their voxel models were made and used in the Monte Carlo simulations. The results of the simulation were c...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq491

    authors: Vrba T

    更新日期:2011-03-01 00:00:00

  • Fetal radiation dose in computed tomography.

    abstract::The connection between recorded volumetric CT dose index (CTDI vol) and determined mean fetal dose (Df) was examined from metal-oxide-semiconductor field-effect transistor dose measurements on an anthropomorphic female phantom in four stages of pregnancy in a 64-slice CT scanner. Automated tube current modulation kept...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncv097

    authors: Kelaranta A,Kaasalainen T,Seuri R,Toroi P,Kortesniemi M

    更新日期:2015-07-01 00:00:00

  • An overview on extremity dosimetry in medical applications.

    abstract::Some activities of EURADOS Working Group 9 (WG9) are presently funded by the European Commission (CONRAD project). The objective of WG9 is to promote and co-ordinate research activities for the assessment of occupational exposures to staff at workplaces in interventional radiology (IR) and nuclear medicine. For some o...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章,评审

    doi:10.1093/rpd/ncn149

    authors: Vanhavere F,Carinou E,Donadille L,Ginjaume M,Jankowski J,Rimpler A,Sans Merce M

    更新日期:2008-01-01 00:00:00

  • Study on the response of indigenously developed CaSO4:Dy phosphor-based neutron dosemeter.

    abstract::In the present paper, we report the indigenous development of a neutron-sensitive thermoluminescent dosemeter (TLD) based on CaSO4:Dy Teflon TL disc. The study includes indigenous development of a neutron dosemeter and its response in terms of operational quantity to different energies of neutrons under various irradi...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncp019

    authors: Bakshi AK,Pradhan AS,Kher RK,Srivastava K,Varadharajan G,Chatterjee S,Sathian V

    更新日期:2009-01-01 00:00:00

  • Population dose in the vicinity of closed Hungarian uranium mine.

    abstract::In order to determine the exposure to natural sources of radiation for people in the vicinity of remediated Hungarian uranium mine regional surveys were carried out. The surveys evaluated indoor radon concentrations and outdoor and indoor external gamma dose rates. Radon concentration has been measured with nuclear et...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci363

    authors: Gorjánácz Z,Várhegyi A,Kovács T,Somlai J

    更新日期:2006-01-01 00:00:00

  • ESTIMATION OF ORGAN DOSES AMONG DIAGNOSTIC MEDICAL RADIATION WORKERS IN SOUTH KOREA.

    abstract::This study aimed to estimate the radiation organ doses from occupational exposure in 94 396 Korean medical radiation workers. Data on badge doses (i.e. personal dose equivalent at 10 mm) between 1996 and 2011 obtained from a national dosimetry registry, survey data from 2012 to 2013, and organ dose conversion coeffici...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncx239

    authors: Choi Y,Shil Cha E,Jin Bang Y,Ko S,Ha M,Lee C,Jin Lee W

    更新日期:2018-04-01 00:00:00

  • Thermoluminescence dosimetric characteristics of beta irradiated salt.

    abstract::The thermoluminescence (TL) characteristics of sodium chloride (NaCl), known as common salt, used for cooking purposes (iodised salt), have been studied in the present paper considering its usage as an 'accidental dosemeter' in the case of a nuclear fallout. TL characteristics of common salt have been examined under e...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci568

    authors: Murthy KV,Pallavi SP,Rahul G,Patel YS,Sai Prasad AS,Elangovan D

    更新日期:2006-01-01 00:00:00

  • Simulation of 125I induced DNA strand breaks in a CAP-DNA complex.

    abstract::The E. coli catabolite gene activator protein (CAP)-DNA complex with 125I located at the position of the H5 atom of the cytosine near the centre was incorporated into the PARTRAC track structure code. DNA strand breaks due to irradiation were calculated by track structure and radical attack simulations; strand breaks ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006738

    authors: Li W,Friedland W,Jacob P,Paretzke HG,Panyutin I,Neumann RD

    更新日期:2002-01-01 00:00:00

  • Evaluation of the performance of two LiF:Mg,Ti and LiF:Mg,Cu,P dosemeters for extremity monitoring.

    abstract::In this paper, the results aimed at assessing the performance of two varieties of LiF detectors (LiF:Mg,Ti and LiF:Mg,Cu,P) in photon fields relatively to reproducibility, detection threshold and angular dependence as defined in the ISO 12794 standard are presented. The fading properties and the limit of detection wer...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq366

    authors: Freire LC,Pereira MF,Calado AM,Santos LM,Cardoso JV,Alves JG

    更新日期:2011-03-01 00:00:00

  • Use of various microdosimetric models for the prediction of radon induced damage in human lungs.

    abstract::Exposure to radon and radon decay products in some residential areas and at workplaces constitutes one of the greatest risks from natural sources of ionising radiation. Recently, increasing attention has been paid to the precise estimations of this health risk by numerous models. The compartmental model published in I...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006173

    authors: Böhm R,Nikodémová D,Holý K

    更新日期:2003-01-01 00:00:00

  • Determination of human absorbed dose of 201Tl(III)-DTPA-HIgG based on biodistribution data in rats.

    abstract::To estimate the absorbed dose in normal organs and inflamed tissue following i.v. administration of [201Tl](III)-DTPA-HIgG by using biodistribution data in inflamation bearing rats was attempted. The percentages of injected dose per gram of each organ were calculated. The medical internal radiation dose formulation was...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq172

    authors: Khorrami Moghaddam A,Reza Jalilian A,Hayati V,Shanehsazzadeh S

    更新日期:2010-10-01 00:00:00

  • NEURAL NETWORK MODELLING OF CARDIAC DOSE CONVERSION COEFFICIENT FOR ARBITRARY X-RAY SPECTRA.

    abstract::In this article, an approach to compute the dose conversion coefficients (DCCs) is described for the computational voxel phantom 'High-Definition Reference Korean-Man' (HDRK-Man) using artificial neural networks (ANN). For this purpose, the voxel phantom was implemented into the Monte Carlo (MC) transport toolkit GEAN...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncv436

    authors: Kadri O,Manai K

    更新日期:2016-12-01 00:00:00

  • Nuclear theory for high-energy nuclear reactions of biomedical relevance.

    abstract::A full description of all possible nuclear reactions that take place in a macroscopic device can only be accomplished with a nuclear model code in combination with key experimental data. To address this issue, the authors demonstrate some of the capabilities of TALYS, a nuclear reaction program which simulates nuclear...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm008

    authors: Koning AJ,Duijvestijn MC

    更新日期:2007-01-01 00:00:00

  • Studies on internal exposure doses received by the cuban population due to the intake of radionuclides from the environmental sources.

    abstract::Studies for the determination of radionuclide concentrations in foodstuffs, water and air were carried out in Cuba for the estimation of annual committed effective doses to members of the public as a result of environmental radionuclides via ingestion and inhalation. As a result of these studies, it was possible to de...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncl002

    authors: Tomás Zerquera J,Prendes Alonso M,Fernández Gómez IM,Rodríguez Castro GV,Martínez Ricardo N,López Bejerano G,Ara do López JO,Acosta Rodríguez N,Carrazana González J,Brígido Flores O,Hernández Pérez A,Díaz Rizo O

    更新日期:2006-01-01 00:00:00

  • Feminist theoretical perspectives on ethics in radiology.

    abstract::The substantive safety of radiological and other medical procedures can be radically reduced by unconscious factors governing scientific thought. In addition, the historical exclusion of women from these disciplines has possibly skewed their development in directions that now need to be addressed. This paper focuses o...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncp055

    authors: Condren M

    更新日期:2009-07-01 00:00:00

  • A SIMULATION STUDY OF DEPOSITION PARAMETERS FOR 129I DISCHARGED FROM THE ROKKASHO REPROCESSING PLANT.

    abstract::The first commercial spent nuclear fuel reprocessing plant at Rokkasho in Japan discharged 129I from actual spent nuclear fuel into the atmosphere during its test operation from 2006 to 2008. Previously, we measured monthly atmospheric concentrations of gaseous and particulate 129I and atmospheric deposition rates of ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncz061

    authors: Abe K,Hasegawa H,Akata N,Kakiuchi H,Chiang JH,Suwa H,Hisamatsu S

    更新日期:2019-10-01 00:00:00

  • INVESTIGATION OF THE INFLUENCE OF THE POSITION INSIDE A SMALL AIRCRAFT ON THE COSMIC-RADIATION-INDUCED DOSE.

    abstract::This article report the measurements on-board a small aircraft at the same altitude and around the same geographic coordinates. The measurements of Ambient Dose Equivalent Rate (H*(10)) were performed in several positions inside the aircraft, close and far from the pilot location and the discrimination between neutron...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncw384

    authors: Prado ACM,Pazianotto MT,Gonçalez OL,Dos Santos LR,Caldeira AD,Pereira HHC,Hubert G,Federico CA

    更新日期:2017-11-01 00:00:00

  • QUADOS intercomparison: a summary of photon and charged particle problems.

    abstract::QUADOS, a Concerted Action of the European Commission, has promoted an intercomparison aimed at evaluating the use of computational codes for dosimetry in radiation protection and medical physics. This intercomparison was open to all users of radiation transport codes. Eight problems were selected for their relevance ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci197

    authors: Gualdrini G,Agosteo S,Ménard S,Price RA,Chartier JL,Grosswendt B,Kodeli I,Leuthold GP,Siebert BR,Tagziria H,Tanner RJ,Terrissol M,Zankl M

    更新日期:2005-01-01 00:00:00

  • DEVELOPMENT AND APPLICATION OF SOLID FORMS OF CaSO4:Dy THERMOLUMINESCENT DOSEMETERS IN RADIATION PROTECTION DOSIMETRY-A REVIEW.

    abstract::CaSO4:Dy is a reliable high-sensitive themoluminescent phosphor useful for low-level and high-level radiation measurements as it exhibits fading free linear dose response with a single glow peak at ~230°C in these dose regions. For large-scale radiation protection dosimetry service, it is embedded in Teflon matrix wit...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章,评审

    doi:10.1093/rpd/ncx287

    authors: Lakshmanan A

    更新日期:2018-10-01 00:00:00

  • Blood tritium level as an estimate of soft tissue dose.

    abstract::To test the blood tritium level as an estimate of free water tritium (FWT) and organically bound tritium (OBT) in human soft tissues, a tritiated amino acid mixture (TAA) and tritiated water (HTO) were injected or orally administered to mice. Relatively high tritium retention in the blood was found after TAA injection...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006272

    authors: Saito M

    更新日期:2003-01-01 00:00:00

  • AVIDOS--a software package for European accredited aviation dosimetry.

    abstract::AVIDOS is a computer code used for the dose assessment of aircraft crew exposed to cosmic radiation. The code employs a multiparameter model built upon simulations of cosmic radiation exposure done using the FLUKA Monte Carlo code. AVIDOS calculates both ambient dose equivalent H*(10) and effective dose E for flight r...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncp126

    authors: Latocha M,Beck P,Rollet S

    更新日期:2009-10-01 00:00:00

  • IDACstar: A MCNP Application to Perform Realistic Dose Estimations from Internal or External Contamination of Radiopharmaceuticals.

    abstract::A Monte Carlo-based stand-alone program, IDACstar (Internal Dose Assessment by Computer), was developed, dedicated to perform radiation dose calculations using complex voxel simulations. To test the program, two irradiation situations were simulated, one hypothetical contamination case with 600 MBq of 99mTc and one ex...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncw221

    authors: Ören Ü,Hiller M,Andersson M

    更新日期:2017-04-28 00:00:00

  • Radiative models for the evaluation of the UV radiation at the ground.

    abstract::The variety of radiative models for solar UV radiation is discussed. For the evaluation of measured UV radiation at the ground the basic problem is the availability of actual values of the atmospheric parameters that influence the UV radiation. The largest uncertainties are due to clouds and aerosol, which are highly ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncp211

    authors: Koepke P

    更新日期:2009-12-01 00:00:00

  • On the use of LiF TLD-600 in neutron-gamma mixed fields.

    abstract::A new procedure allowing the separate estimation of neutron and gamma dose in mixed radiation fields has been developed in our laboratory. In this communication, a description of the main features of the discrimination procedure and some preliminary results obtained by its use are presented. The procedure is based on ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm210

    authors: Delgado A,Muñiz JL,Gómez Ros JM,Romero AM,Rodríguez R

    更新日期:2007-01-01 00:00:00