Population dose in the vicinity of closed Hungarian uranium mine.

Abstract:

:In order to determine the exposure to natural sources of radiation for people in the vicinity of remediated Hungarian uranium mine regional surveys were carried out. The surveys evaluated indoor radon concentrations and outdoor and indoor external gamma dose rates. Radon concentration has been measured with nuclear etched track detectors for 4 months in 129 houses in Kovágószolos and in 23 houses in Cserkút. In some houses measurements have been carried out for a year and the measurement results of the 4 months were corrected according to these. The corrected radon concentrations altered between 15 and 2314 Bq m(-3). An average of 257 Bq m(-3) in Kovágószolos and 125 Bq m(-3) in Cserkút was measured. The average was 434 Bq m(-3) for the 48 houses within 100 m of the passage of the former mine that is under the village of Kovágószolos. The higher values of Kovágószolos are likely to be the result of the influence of mining. The terrestrial gamma-ray dose rate was measured outdoors and indoors at these houses. Values of 139 (62-233) nGy h(-1) and 133 (93-275) nGy h(-1) were measured in Kovágószolos and Cserkút, respectively. The average annual effective doses for the two villages studied were 3 and 5 mSv y(-1), but the maximum value was 40 mSv y(-1).

journal_name

Radiat Prot Dosimetry

authors

Gorjánácz Z,Várhegyi A,Kovács T,Somlai J

doi

10.1093/rpd/nci363

keywords:

subject

Has Abstract

pub_date

2006-01-01 00:00:00

pages

448-52

issue

4

eissn

0144-8420

issn

1742-3406

pii

nci363

journal_volume

118

pub_type

杂志文章
  • ESTIMATION OF EXPOSURE DOSES FOR THE SAFE MANAGEMENT OF NORM WASTE DISPOSAL.

    abstract::Naturally occurring radioactive materials (NORM) wastes with different radiological characteristics are generated in several industries. The appropriate options for NORM waste management including disposal options should be discussed and established based on the act and regulation guidelines. Several studies calculate...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncy041

    authors: Jeong J,Ko NY,Cho DK,Baik MH,Yoon KH

    更新日期:2018-11-01 00:00:00

  • How to prepare head tissue-equivalent liquids for SAR calculations, dosimetry and hyperthermia researches at 900 and 1800 MHz GSM frequencies.

    abstract::The potential harmful effect of electromagnetic fields on human health is an important issue that has been widely discussed in the scientific community. The investigation of temperature rise in human body following exposure to electromagnetic fields has been found impractical in many aspects. Therefore, fabrication of...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncv351

    authors: Sorgucu U,Develi I,Ozen S

    更新日期:2016-03-01 00:00:00

  • Radiation protection at low energy proton accelerators.

    abstract::A sample is provided of the radiological safety issues particular to low energy proton accelerators. 'Low' energy in this context is taken to mean proton energies of less than about 1 GeV. Many of the radiation issues are common to all particle accelerators. Here, those issues are addressed that may require perhaps no...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章,评审

    doi:10.1093/oxfordjournals.rpd.a006619

    authors: Moritz LE

    更新日期:2001-01-01 00:00:00

  • The resulting skin dose in two-view mammography examinations.

    abstract::The entrance surface dose (ESD) (skin dose) and its variation due to overlapping radiation fields at mammography have been experimentally investigated on patients during two-view mammography screening examinations of both breasts and on phantoms of silicon gel. Measurements were done using multiple thermoluminescence ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq077

    authors: Adliene D,Cibulskaite I,Laurikaitiene J,Adlys G

    更新日期:2010-04-01 00:00:00

  • Review of retrospective dosimetry techniques for external ionising radiation exposures.

    abstract::The current focus on networking and mutual assistance in the management of radiation accidents or incidents has demonstrated the importance of a joined-up approach in physical and biological dosimetry. To this end, the European Radiation Dosimetry Working Group 10 on 'Retrospective Dosimetry' has been set up by indivi...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章,评审

    doi:10.1093/rpd/ncq499

    authors: Ainsbury EA,Bakhanova E,Barquinero JF,Brai M,Chumak V,Correcher V,Darroudi F,Fattibene P,Gruel G,Guclu I,Horn S,Jaworska A,Kulka U,Lindholm C,Lloyd D,Longo A,Marrale M,Monteiro Gil O,Oestreicher U,Pajic J,Rakic B

    更新日期:2011-11-01 00:00:00

  • Thorium isotopic analysis by alpha spectrometry.

    abstract::The technique of alpha spectrometry is used to detect alpha particles and to determine their energy. In this way the technique is able to provide simultaneously quantitative information (i.e. the activity) and qualitative information (the identity) on any radionuclide that emits an alpha particle. The longer-lived nat...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006646

    authors: Gingell T

    更新日期:2001-01-01 00:00:00

  • Method of thermoluminescent measurement of radiation doses from micrograys up to a megagray with a single LiF:Mg,Cu,P detector.

    abstract::On the basis of the newly discovered behaviour of LiF:Mg,Cu,P detectors at high and ultra-high doses, a new method of thermoluminescence (TL) measurement of radiation doses ranging from micrograys up to a megagray, has been recently developed at the Institute of Nuclear Physics (IFJ). The method is based on the relati...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq339

    authors: Obryk B,Bilski P,Olko P

    更新日期:2011-03-01 00:00:00

  • Study on the response of indigenously developed CaSO4:Dy phosphor-based neutron dosemeter.

    abstract::In the present paper, we report the indigenous development of a neutron-sensitive thermoluminescent dosemeter (TLD) based on CaSO4:Dy Teflon TL disc. The study includes indigenous development of a neutron dosemeter and its response in terms of operational quantity to different energies of neutrons under various irradi...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncp019

    authors: Bakshi AK,Pradhan AS,Kher RK,Srivastava K,Varadharajan G,Chatterjee S,Sathian V

    更新日期:2009-01-01 00:00:00

  • No evidence for a low linear energy transfer adaptive response in irradiated RKO cells.

    abstract::It has become increasingly evident from reports in the literature that there are many confounding factors capable of modulating radiation-induced non-targeted responses, such as the bystander effect and the adaptive response. In this paper, we examine recent data which suggest that the observation of non-targeted resp...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq487

    authors: Sowa MB,Goetz W,Baulch JE,Lewis AJ,Morgan WF

    更新日期:2011-02-01 00:00:00

  • Review of international standards for dosemeters.

    abstract::International standards for radiation protection dosemeters are published by the International Electrotechnical Commission and the International Organization for Standardization. Several standards exist side by side, although they treat the same measuring task, and specify different requirements, so that dosemeters of...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章,评审

    doi:10.1093/rpd/ncm331

    authors: Behrens R,Ambrosi P

    更新日期:2008-01-01 00:00:00

  • Recent results of irradiations of DIS-1 dosemeters with an XR200 X-ray flash unit.

    abstract::Earlier measurements have revealed that active electronic dosemeters have deficiencies in pulsed fields of ionising radiation due to the counting technique used. The DIS-1 dosemeter uses a promising technology, which should be basically suitable for measurements in pulsed fields. In this paper, first measurements with...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncs265

    authors: Zutz H,Hupe O

    更新日期:2013-05-01 00:00:00

  • Absorbed dose rate estimation for protons, leptons and helium observed with AMS01 experiment in low earth orbit during STS-91 mission.

    abstract::The Alpha Magnetic Spectrometer (AMS01), a high-sensitivity particle spectrometer, was successfully flown for 10 d in June 1998 (STS91) in the orbit of the International Space Station (51.7 degrees, -380 km). A high-statistics dataset of galactic cosmic rays were measured as a function of geomagnetic latitude, includi...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci071

    authors: Ionica M,Alpat B,Ambrosi G,Battiston R,Bertucci B,Burger WJ,Caraffini D,Cecchi C,Dinu N,Esposito G,Fiandrini E,Ionica R,Menichelli M,Pauluzzi M,Zuccon P

    更新日期:2005-01-01 00:00:00

  • In situ occupational and general public exposure to VHF/UHF transmission for air traffic communication.

    abstract::Occupational and general public exposure due to very high frequency (VHF)/ultra high frequency (UHF) transmission centres for verbal communication for air traffic control is investigated in situ for the first time. These systems are used for communication with aircraft, resulting in different human exposure from that ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncs016

    authors: Joseph W,Goeminne F,Verloock L,Vermeeren G,Martens L

    更新日期:2012-09-01 00:00:00

  • CAN HALF VALUE LAYER MEASUREMENTS BE USED TOGETHER WITH THE EFFECTIVE ENERGY TO OBTAIN CONVERSION COEFFICIENTS FOR X-RAY SPECTRA?

    abstract::Conversion coefficients are a substantial vehicle in practical radiation protection to determine the dose (rate) of a given radiation field. According to ICRU report 57, their values shall be obtained by means of spectrometry. This is, however, a time-consuming complicated procedure that cannot be performed by all dos...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncw003

    authors: Behnke B,Hupe O

    更新日期:2017-04-15 00:00:00

  • Shielding Effect of Lead Glasses on Radiologists' Eye Lens Exposure in Interventional Procedures.

    abstract::To study the shielding effect of radiologists' eye lens with lead glasses of different equivalent thicknesses and sizes in interventional radiology procedures. Using the human voxel phantom with a more accurate model of the eye and MCNPX software, eye lens doses of the radiologists who wearing different kinds of lead ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncw098

    authors: Hu P,Kong Y,Chen B,Liu Q,Zhuo W,Liu H

    更新日期:2017-04-20 00:00:00

  • Dosimetric monitoring in Ukraine--present status and path to the future.

    abstract::Despite wide use of nuclear energy and radiation sources in industry and medicine, there is no centralised dose accounting system in Ukraine; existing dosimetry services operate obsolete manual thermoluminescence dosemeter (TLD) readers and do not meet modern proficiency standards. Currently, dosimetric monitoring is ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncl128

    authors: Chumak V,Boguslavskaya A

    更新日期:2007-01-01 00:00:00

  • Radiation Protection Studies for Medical Particle Accelerators using Fluka Monte Carlo Code.

    abstract::Radiation protection (RP) in the use of medical cyclotrons involves many aspects both in the routine use and for the decommissioning of a site. Guidelines for site planning and installation, as well as for RP assessment, are given in international documents; however, the latter typically offer analytic methods of calc...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncw302

    authors: Infantino A,Cicoria G,Lucconi G,Pancaldi D,Vichi S,Zagni F,Mostacci D,Marengo M

    更新日期:2017-04-01 00:00:00

  • On the use of LiF TLD-600 in neutron-gamma mixed fields.

    abstract::A new procedure allowing the separate estimation of neutron and gamma dose in mixed radiation fields has been developed in our laboratory. In this communication, a description of the main features of the discrimination procedure and some preliminary results obtained by its use are presented. The procedure is based on ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm210

    authors: Delgado A,Muñiz JL,Gómez Ros JM,Romero AM,Rodríguez R

    更新日期:2007-01-01 00:00:00

  • A study of the irradiation temperature coefficient for L-alanine and DL-alanine dosemeters.

    abstract::Alanine dosimetry is now well established both as a reference and routine dosemeter for industrial irradiation processing. Accurate dosimetry under the relatively harsh conditions of industrial processing requires a characterisation of the parameters that influence the dosemeter response. The temperature of the doseme...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci543

    authors: Desrosiers MF,Lin M,Cooper SL,Cui Y,Chen K

    更新日期:2006-01-01 00:00:00

  • Neutron and photon fields in the BNCT room with closed beam shutters.

    abstract::The epithermal neutron beam at the LVR-15 reactor was designed for the Boron Neutron Capture Therapy (BNCT) of cancers, but it has also been used for material testing. In the case where the beam is closed with two designed shutters, there is still an indispensable background in the irradiation room, which limits the m...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci112

    authors: Marek M,Viererbl L

    更新日期:2005-01-01 00:00:00

  • Seasonal variation of indoor radon-222 levels in dwellings in Ramallah province and East Jerusalem suburbs, Palestine.

    abstract::This study presents the seasonal variations of indoor radon levels in dwellings located in the Ramallah province and East Jerusalem suburbs, Palestine. The measurements were performed during the summer and winter of the year 2006/2007 using CR-39 solid-state-nuclear-track detectors. The total number of investigated bu...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncr013

    authors: Leghrouz AA,Abu-Samreh MM,Shehadeh AK

    更新日期:2012-01-01 00:00:00

  • Determination of human absorbed dose of 201Tl(III)-DTPA-HIgG based on biodistribution data in rats.

    abstract::To estimate the absorbed dose in normal organs and inflamed tissue following i.v. administration of [201Tl](III)-DTPA-HIgG by using biodistribution data in inflamation bearing rats was attempted. The percentages of injected dose per gram of each organ were calculated. The medical internal radiation dose formulation was...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq172

    authors: Khorrami Moghaddam A,Reza Jalilian A,Hayati V,Shanehsazzadeh S

    更新日期:2010-10-01 00:00:00

  • The use of a figure-of-merit (FOM) for optimisation in digital mammography: a literature review.

    abstract::The use of image quality parameters in digital mammography such as contrast-to-noise ratio (CNR), signal-to-noise ratio (SNR) and detective quantum efficiency (DQE) has been widespread, with the intention of detector evaluation and/or quantitative evaluation of the system performance. These parameters are useful in en...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章,评审

    doi:10.1093/rpd/ncr465

    authors: Borg M,Badr I,Royle GJ

    更新日期:2012-08-01 00:00:00

  • Suppression methods of radon emanation from phosphorus fertiliser and diatomaceous earth.

    abstract::The present paper shows methods to suppress radon emanation from artificial porous materials such as phosphorous fertiliser or diatomaceous earth with a small amount of radium. The basic concept of suppression is making the radon emanation mechanism 'null', which comes from the fact that recoil is the main mechanism o...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm420

    authors: Sasaki T,Gunji Y,Okuda T

    更新日期:2007-01-01 00:00:00

  • Exposure caused by wireless technologies used for short-range indoor communication in homes and offices.

    abstract::In order to estimate typical radio frequency exposures from indoor used wireless communication technologies applied in homes and offices, WLAN, Bluetooth and Digital Enhanced Cordless Telecommunications systems, as well as baby surveillance devices and wireless headphones for indoor usage, have been investigated by me...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm245

    authors: Schmid G,Lager D,Preiner P,Uberbacher R,Cecil S

    更新日期:2007-01-01 00:00:00

  • Design and fabrication of a multipurpose thyroid phantom for medical dosimetry and calibration.

    abstract::A multipurpose anthropomorphic neck phantom was designed and fabricated for use in medical applications. The designed neck phantom is composed of seven elliptic cylindrical slices with a semi-major axis of 14 cm and a semi-minor axis of 12.5 cm, each having the thickness of 2 cm. The thyroid gland, bony part of the ne...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncv359

    authors: Mehdizadeh Naderi S,Sina S,Karimipoorfard M,Lotfalizadeh F,Entezarmahdi M,Moradi H,Faghihi R

    更新日期:2016-03-01 00:00:00

  • Development of a new thoron progeny detector based on SSNTD and the collection by an electric field.

    abstract::The importance of (220)Rn (thoron) progeny for human exposure has been widely recognised in the past decades. Since no stable equilibrium factor was found between indoor thoron and its progeny, and the concentration of thoron progeny varies with time, it is necessary to develop detectors for long-term measurement that...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncr078

    authors: Bi L,Tschiersch J,Meisenberg O,Wielunski M,Li JL,Shang B

    更新日期:2011-05-01 00:00:00

  • NASA Space Radiation Transport Code Development Consortium.

    abstract::Recently, NASA established a consortium involving the University of Tennessee (lead institution), the University of Houston, Roanoke College and various government and national laboratories, to accelerate the development of a standard set of radiation transport computer codes for NASA human exploration applications. T...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci092

    authors: Townsend LW

    更新日期:2005-01-01 00:00:00

  • Practical application of the ICRP Human Respiratory Tract Model.

    abstract::The ICRP Publication 66 Human Respiratory Tract Model (HRTM) has been applied to calculate dose coefficients and bioassay functions using default values of parameters relating to the material and the subjects. The ICRP Task Group on Internal Dosimetry (INDOS) has developed a guidance document on application of the HRT...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006324

    authors: Bailey MR,Ansoborlo E,Guilmette RA,Paquet F

    更新日期:2003-01-01 00:00:00

  • Microdosimetric investigation at the therapeutic proton beam facility of CATANA.

    abstract::Proton beams (62 Mev) are used by the Laboratori Nazionali del Sud of the Italian Institute of Nuclear Physics to treat eye melanoma tumours at the therapeutic facility called CATANA. A cylindrical slim tissue-equivalent proportional counter (TEPC) of 2.7 mm external diameter has been used to compare the radiation qua...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch111

    authors: De Nardo L,Moro D,Colautti P,Conte V,Tornielli G,Cuttone G

    更新日期:2004-01-01 00:00:00