Shielding Effect of Lead Glasses on Radiologists' Eye Lens Exposure in Interventional Procedures.

Abstract:

:To study the shielding effect of radiologists' eye lens with lead glasses of different equivalent thicknesses and sizes in interventional radiology procedures. Using the human voxel phantom with a more accurate model of the eye and MCNPX software, eye lens doses of the radiologists who wearing different kinds of lead glasses were simulated, different beam projections were taken into consideration during the simulation. Measurements were also performed with the physical model to verify simulation results. Simulation results showed that the eye lens doses were reduced by a factor from 3 to 9 when wearing a 20 cm2-sized lead glasses with the equivalent thickness ranging from 0.1 to 1.0 mm Pb. The increase of dose reduction factor (DRF) was not significant whenever increase the lead equivalent of glasses of which larger than 0.35 mm. Furthermore, the DRF was proportional to the size of glass lens from 6 to 30 cm2 with the same lead equivalent. The simulation results were in well agreements with the measured ones. For more reasonable and effective protection of the eye lens of interventional radiologists, a pair of glasses with a lead equivalent of 0.5 mm Pb and large-sized (at least 27 cm2 per glass) lens are recommended.

journal_name

Radiat Prot Dosimetry

authors

Hu P,Kong Y,Chen B,Liu Q,Zhuo W,Liu H

doi

10.1093/rpd/ncw098

subject

Has Abstract

pub_date

2017-04-20 00:00:00

pages

136-140

issue

1

eissn

0144-8420

issn

1742-3406

pii

ncw098

journal_volume

174

pub_type

杂志文章
  • Analysis and improvement of cyclotron thallium target room shield.

    abstract::Because of high neutron and gamma-ray intensities generated during bombardment of a thallium-203 target, a thallium target-room shield and different ways of improving it have been investigated. Leakage of neutron and gamma ray dose rates at various points behind the shield are calculated by simulating the transport of...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncn099

    authors: Hajiloo N,Raisali G,Aslani G

    更新日期:2008-01-01 00:00:00

  • Novel developments in the MOSFET dosemeter for neutron dosimetry applications.

    abstract::The feasibility of large-geometry Metal Oxide Semiconductor Field Effect Transistor (MOSFET) devices has been assessed for both active and passive neutron dosimetry and use in radiotherapy environments. Neutron sensitivity has been enhanced with the use of polymeric cement surrounding the gate region. Neutron activati...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch202

    authors: Price RA,Benson C,Joyce MJ,Kestell DJ,Silvie J

    更新日期:2004-01-01 00:00:00

  • Individual monitoring in mixed neutron/photon fields using a single silicon detector.

    abstract::A device based on a single silicon detector of special converter/detector design optimised for the determination of the neutron dose equivalent is also used for the determination of the photon dose equivalent. While the neutron dose is determined on the basis of signals corresponding to energy depositions above 1.5 Me...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a005962

    authors: Luszik-Bhadra M

    更新日期:2002-01-01 00:00:00

  • Collaboration of local government and experts responding to increase in environmental radiation level due to the nuclear disaster: focusing on their activities and latest radiological discussion.

    abstract::Activities were introduced in Kashiwa city in the Tokyo metropolitan area to correspond to the elevated environmental radiation level after the disaster of the Fukushima Daiichi nuclear power plant. These were based on a strong cooperation between local governments and experts. Ambient dose rate and radioactivity of f...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncv279

    authors: Iimoto T,Nunokawa J,Fujii H,Takashima R,Hashimoto M,Fukuhara T,Yajima T,Matsuzawa H,Kurosawa K,Yanagawa Y,Someya S

    更新日期:2015-11-01 00:00:00

  • Determination of committed effective doses to skin due to ²³⁸U, ²³²Th and ²²²Rn from the application of various Moroccan black soap (Saboun Beldi) samples by members of the general public.

    abstract::(238)U, (232)Th, (222)Rn and (220)Rn concentrations were measured inside various Moroccan black soap samples widely used by the Moroccan population in traditional baths (Hammans) by using both CR-39 and LR-115 type II solid state nuclear track detectors. The measured (238)U, (232)Th, (222)Rn and (220)Rn concentrations...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq275

    authors: Misdaq MA,Outeqablit K

    更新日期:2010-12-01 00:00:00

  • Mechanistic modelling of genetic and epigenetic events in radiation carcinogenesis.

    abstract::Methodological problems arise on the way of radiation carcinogenesis modelling with the incorporation of radiobiological and cancer biology mechanistic data. The results of biophysical modelling of different endpoints [DNA DSB induction, repair, chromosome aberrations (CA) and cell proliferation] are presented and app...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncl463

    authors: Andreev SG,Eidelman YA,Salnikov IV,Khvostunov IK

    更新日期:2006-01-01 00:00:00

  • USE OF CLINICAL EXPOSURE INDEX AND DEVIATION INDEX BASED ON NATIONAL DIAGNOSTIC REFERENCE LEVEL AS DOSE-OPTIMIZATION TOOLS FOR GENERAL RADIOGRAPHY IN KOREA.

    abstract::The International Electrotechnical Commission introduced the concepts of exposure index (EI), target exposure index (EIT) and deviation index (DI) to manage and optimize patient dose in real time. In this study, we have proposed an appropriate method for setting the EIT based on the Korean national diagnostic referenc...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncaa185

    authors: Park H,Yoon Y,Kim J,Kim J,Jeong H,Tanaka N,Morishita J

    更新日期:2020-11-17 00:00:00

  • A study of the correlation between dose area product and effective dose in vascular radiology.

    abstract::The purpose of the multi-centre study was to assess dose area product (DAP) and effective dose of patients undergoing angiography of the lower limbs in Belgium and to investigate the correlation between DAP and effective dose. DAP values were measured in 12 centres and compared with the national diagnostic reference l...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncn050

    authors: Smans K,Struelens L,Hoornaert MT,Bleeser F,Buls N,Berus D,Clerinx P,Malchair F,Vanhavere F,Bosmans H

    更新日期:2008-01-01 00:00:00

  • Response of silicon diode dosemeters to scattered radiation from megavoltage photon beams.

    abstract::Dose response effects of diodes due to the high atomic number of silicon relative to water are investigated. While quality chances in the primary component of a megavoltage beam with depth are minimal. Compton scattered photons are shown to have a substantial effect on the quality leading to their enhanced absorption ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006014

    authors: Yin Z,Hugtenburg RP,Beddoe AH

    更新日期:2002-01-01 00:00:00

  • Photoneutron and capture gamma dose equivalent for different room and maze layouts in radiation therapy.

    abstract::In this paper the effect of treatment room and maze layout on the photoneutron and capture gamma dose equivalent in the maze was studied. MCNPX Monte Carlo (MC) code was used to simulate the Varian 2100 C/D Clinac 18 MV and four different room layouts. Two analytical methods, Wu-McGinley and McGinley, were used for do...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncp303

    authors: Mesbahi A,Ghiasi H,Mahdavi SR

    更新日期:2010-08-01 00:00:00

  • AEROSOL SIZE DISTRIBUTION IN URANIUM PROCESSING FACILITY FOR APPLICATION IN THE ASSESSMENT OF INTERNAL EXPOSURE.

    abstract::In circumstances of inhalation exposure the radiotoxicity of radionuclide depends on the fractional deposition of inhaled activity, which is governed by the aerodynamic characteristics of the particles. Although International Commission on Radiological Protection (ICRP) provides default size distribution parameters fo...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncx231

    authors: Shailesh M,Das T,Prabhat M,Kolekar RV,Gopalakrishnan RK

    更新日期:2018-04-01 00:00:00

  • Radiation exposure during paediatric CT in Sudan: CT dose, organ and effective doses.

    abstract::The purpose of this study was to assess the magnitude of radiation exposure during paediatric CT in Sudanese hospitals. Doses were determined from CT acquisition parameters using CT-Expo 2.1 dosimetry software. Doses were evaluated for three patient ages (0-1, 1-5 and 5-10 y) and two common procedures (head and abdome...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncu321

    authors: Suliman II,Khamis HM,Ombada TH,Alzimami K,Alkhorayef M,Sulieman A

    更新日期:2015-12-01 00:00:00

  • COVERING THE PATIENT'S ARM SUPPORT IN LEAD REDUCED THE RADIATION DOSE RATE TO THE CARDIOLOGISTS DURING PERCUTANEOUS CORONARY INTERVENTIONS: A PHANTOM STUDY.

    abstract::The aim of the study was to estimate organ dose rate reduction to a female anthropomorphic phantom, which simulated the cardiologist, during percutaneous coronary interventions (PCI) when the patient's arm support was covered with 0.4-mm lead foil. Organ dose rates were determined using five radiation detectors insert...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncz292

    authors: Fukuda A,Lin PP

    更新日期:2020-06-24 00:00:00

  • Correlation between thermoluminescence and mechanoluminescence of gamma-irradiated Dy activated potassium and magnesium mixed sulphate.

    abstract::Thermoluminescene (TL) and mechanoluminescence (ML) properties of gamma-irradiated Dy activated potassium and magnesium mixed sulphate have been studied. (K2Mg2:Dy) (SO4)3 samples having different concentrations of Dy were prepared by solid-state diffusion method. Two distinct peaks, the first approximately 130 degree...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci607

    authors: Kher RS,Panigrahi AK,Dhoble SJ,Khokhar MS

    更新日期:2006-01-01 00:00:00

  • Determination of a neutron source position in an unknown homogeneous medium; the 2D case.

    abstract::The localisation of an unknown neutron source in various bulky homogeneous media was studied. For the planar case two (3)He detectors on the opposite faces of a box were used. It is shown that the location of a single small neutron emitting source in a large box can be found to a better than 7% by using two neutron de...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm048

    authors: Dubinski S,Presler O,Alfassi ZB

    更新日期:2007-01-01 00:00:00

  • ELECTRON EYE-LENS OPERATIONAL DOSE COEFFICIENTS.

    abstract::In 2012, the International Commission on Radiological Protection issued a recommendation for a reduced annual eye-lens dose limit in the face of mounting evidence of the risk of cataract induction. This led to worldwide research efforts in various areas including the dose simulation in realistic eye-models, the produc...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncz295

    authors: Dubeau J,Sun J

    更新日期:2020-06-24 00:00:00

  • Overview of physical and biophysical techniques for accident dosimetry.

    abstract::From feedback experience from recent radiation accident cases, in addition to biological dosimetry and physical dosimetry based on Monte Carlo calculations or experimental means, there is a need for complementary methods of dosimetry for radiation accident. Electron paramagnetic resonance (EPR) spectrometry on bones o...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章,评审

    doi:10.1093/rpd/ncq341

    authors: Trompier F,Bassinet C,Della Monaca S,Romanyukha A,Reyes R,Clairand I

    更新日期:2011-03-01 00:00:00

  • THE MAYAK WORKER DOSIMETRY SYSTEM-2013 (MWDS-2013): PHASE II-QUALITY ASSURANCE OF ORGAN DOSE CALCULATIONS.

    abstract::In order to check developed software tools, it was necessary to compare estimates of statistical characteristics of annual absorbed plutonium internal doses obtained by PANDORA and IMBA software with the same original data. The results were compared from dose calculations of five cases with different initial data on p...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncx085

    authors: Vostrotin VV,Birchall A,Zhdanov AV,Puncher M

    更新日期:2017-11-01 00:00:00

  • Usability of VTL from natural quartz grains for retrospective dosimetry.

    abstract::To develop retrospective dosimetry of unexpected radiation accident, basic studies on violet thermoluminescence (VTL) phenomena were conducted using natural quartz grains. All VTL glowcurves of as-received samples did not exhibit peaks <250 degrees C, although for artificially irradiated quartz samples there were VTL ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncl108

    authors: Fujita H,Hashimoto T

    更新日期:2007-01-01 00:00:00

  • DOSE AREA PRODUCT VALUES OF FLUOROSCOPICALLY GUIDED PAIN MANAGEMENT PROCEDURES: COMPARISON OF A BELGIAN TEACHING HOSPITAL WITH NATIONAL DIAGNOSTIC REFERENCE LEVELS.

    abstract::In 2011, national diagnostic reference levels (DRLs) were proposed for pain management fluoroscopic procedures in Belgium. The primary goal of this work is to compare the dose area product values (DAP) recorded at the Saint-Luc University Hospital to these DRLs. From 2012 to 2015, 7664 interventional pain management p...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncx271

    authors: Hustinx N,Steyaert A,le Polain de Waroux B,Forget P

    更新日期:2018-05-01 00:00:00

  • Assessments of medical exposures during interventional radiology procedures.

    abstract::This study aims to contribute to the construction of a scenario regarding patient radiation exposure in Brazilian interventional radiology, aiming to provide data for the future drafting of specific legislation on interventional radiology because there is currently a lack of safety regulations for haemodynamics servic...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncs172

    authors: Navarro VC,Navarro MV,Maia AF

    更新日期:2013-04-01 00:00:00

  • Dosimetry of a set-up for the exposure of newborn mice to 2.45-GHZ WiFi frequencies.

    abstract::This work describes the dosimetry of a two waveguide cell system designed to expose newborn mice to electromagnetic fields associated with wireless fidelity signals in the frequency band of 2.45 GHz. The dosimetric characterisation of the exposure system was performed both numerically and experimentally. Specific meas...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq129

    authors: Pinto R,Lopresto V,Galloni P,Marino C,Mancini S,Lodato R,Pioli C,Lovisolo GA

    更新日期:2010-08-01 00:00:00

  • Liulin-type spectrometry-dosimetry instruments.

    abstract::The main purpose of Liulin-type spectrometry-dosimetry instruments (LSDIs) is cosmic radiation monitoring at the workplaces. An LSDI functionally is a low mass, low power consumption or battery-operated dosemeter. LSDIs were calibrated in a wide range of radiation fields, including radiation sources, proton and heavy-...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq506

    authors: Dachev Ts,Dimitrov P,Tomov B,Matviichuk Y,Spurny F,Ploc O,Brabcova K,Jadrnickova I

    更新日期:2011-03-01 00:00:00

  • A survey on uncertainty in bioassay measurements carried out within the OMINEX project.

    abstract::One of the topics covered by the OMINEX (Optimisation of Monitoring for Internal Exposure) project was to look at the bioassay measurements performed in the European laboratories. Questionnaires on bioassay measurements by alpha spectrometry or inductively coupled plasma-mass spectrometry (ICP-MS) were sent to Europea...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006261

    authors: Hurtgen C,Cossonnet C

    更新日期:2003-01-01 00:00:00

  • Measured proton sensitivities of bubble detectors.

    abstract::The neutron dose equivalent in aircraft is measured using commercial bubble detectors, but at high altitudes there are not only neutrons but also protons. Bubble detectors have been used because they are considered not to be sensitive to protons, but this has been the subject of only a few studies. In this study, by i...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch330

    authors: Takada M,Kitamura H,Koi T,Nakamura T,Fujitaka K

    更新日期:2004-01-01 00:00:00

  • Design of a multi-element TEPC for neutron monitoring.

    abstract::Tissue-equivalent proportional counters (TEPCs) have long been considered suitable candidate instruments for more accurate neutron monitors in nuclear power plants. It has also been recognised that the production of truly light-weight devices based on TEPCs requires further effort directed towards increasing their sen...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq538

    authors: Waker AJ,Aslam,Lori J

    更新日期:2011-02-01 00:00:00

  • AUTOMATIC BRAIN DOSE ESTIMATION IN COMPUTED TOMOGRAPHY USING PATIENT DICOM IMAGES.

    abstract::This study aims to develop an Automatic Brain Dose Estimation (ABDE) methodology for head computed tomography examinations. The ABDE is to be applied first to an anthropomorphic Alderson phantom to obtain a Correction factor (Cf) between the ABDE and the direct absorbed brain dose using dosemeters positioned within th...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncaa006

    authors: Gharbi S,Labidi S,Mars M

    更新日期:2020-07-02 00:00:00

  • Calculation and Validation of the Response Matrix for a Neutron Multisphere Spectrometer with an Indium Central Detector.

    abstract::Expansion of accelerator technologies into different application areas brings the need for neutron-field measurements in their vicinity. The measurements of neutron energy spectra and neutron dose rates can be done with the aid of neutron multisphere spectrometers with passive neutron detectors. In addition to the usu...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncx183

    authors: Vlk P,Pavlovic M

    更新日期:2018-04-01 00:00:00

  • Protocols for dosimetry and patient reference levels.

    abstract::Doses in radiology should be as low as reasonably achievable. In order to compare practice in different centres it is necessary to compare patient doses. This can only be undertaken if dosimetry studies are similar. In order to facilitate comparisons, the DIMOND consortium developed a patient dosimetry protocol. Refer...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci715

    authors: Faulkner K

    更新日期:2005-01-01 00:00:00

  • COMPARISON STUDY OF VARIOUS PLASTICS AS THE WALL MATERIAL OF THGEM-BASED MICRODOSEMETERS FOR FAST NEUTRON MEASUREMENTS.

    abstract::To find appropriate substitutions for the expensive plastics of A-150 and rexolite used in the construction of thick gas electron multiplier (THGEM)-based tissue-equivalent proportional counters, in the present work, the responses of a THGEM-based microdosimetric detector made of A-150 and rexolite and three others co...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncw008

    authors: Moslehi A,Raisali G,Lamehi M

    更新日期:2017-04-15 00:00:00