AEROSOL SIZE DISTRIBUTION IN URANIUM PROCESSING FACILITY FOR APPLICATION IN THE ASSESSMENT OF INTERNAL EXPOSURE.

Abstract:

:In circumstances of inhalation exposure the radiotoxicity of radionuclide depends on the fractional deposition of inhaled activity, which is governed by the aerodynamic characteristics of the particles. Although International Commission on Radiological Protection (ICRP) provides default size distribution parameters for work place aerosols, inhaled aerosol characteristics may be different depending on the physical and chemical conditions of aerosol generation process. The present study is undertaken to determine the particle activity-size distribution during operation of various significant processes of uranium metal production facility of Bhabha Atomic Research Centre (BARC). Activity median aerodynamic diameter (AMAD) and its geometric standard deviation (GSD) were estimated for these process areas for uranium aerosol particles. The AMAD varied from 3.2 to 10.06 µm and GSD ranged from 1.5 to 3.0. Also, the obtained size distribution was tested by Pearson's chi-squared distribution test method to ascertain the assumption that the particle size distribution is best described by log-normal relationship.

journal_name

Radiat Prot Dosimetry

authors

Shailesh M,Das T,Prabhat M,Kolekar RV,Gopalakrishnan RK

doi

10.1093/rpd/ncx231

subject

Has Abstract

pub_date

2018-04-01 00:00:00

pages

119-124

issue

2

eissn

0144-8420

issn

1742-3406

pii

4566638

journal_volume

179

pub_type

杂志文章
  • A recoil-proton spectrometer based on a p-i-n diode implementing pulse-shape discrimination.

    abstract::A recoil-proton spectrometer was created by coupling a p-i-n diode with a polyethylene converter. The maximum detectable energy, imposed by the thickness of the totally depleted layer, is approximately 6 MeV. The minimum detectable energy is limited by the contribution of secondary electrons generated by photons in th...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch237

    authors: Agosteo S,D'Angelo G,Fazzi A,Foglio Para A,Pola A,Ventura L,Zotto P

    更新日期:2004-01-01 00:00:00

  • A family of statistical distributions for modelling occupational radiation doses in low dose occupations.

    abstract::New statistical distributions have been defined to describe occupational exposures to ionising radiation. These distributions are particularly useful in modelling occupations where most doses are low. The maximum likelihood method was used for parameter estimation and has been adapted to allow doses that are recorded ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncl045

    authors: Sont WN

    更新日期:2006-01-01 00:00:00

  • Specific features of the influence of high-energy electron beams on the luminescent properties of undoped and Nb, Fe-doped Al₂O₃ crystals.

    abstract::The influence of 10 MeV high-current electron beams accelerated by the M-30 microtron on the luminescent properties of the α-Al₂O₃, Al₂O₃:Nb and Al₂O₃:Fe crystals has been studied. The effect of the long-term phosphorescence at room temperature has been found that can be used to monitor electron and gamma accelerator ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncu213

    authors: Maslyuk VT,Megela IG,Okunieva TO,Pekar JM,Pekar VJ

    更新日期:2014-11-01 00:00:00

  • Assessment of natural radioactivity concentrations and gamma dose rate levels in Kayseri, Turkey.

    abstract::This study assesses the level of background radiation for Kayseri province of Turkey. Natural radionuclide activity concentrations in soil samples were determined using high-resolution gamma spectroscopy. Outdoor gamma dose measurements in air at 1 m above ground level were determined using a portable gamma scintillat...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncr023

    authors: Otansev P,Karahan G,Kam E,Barut I,Taskin H

    更新日期:2012-01-01 00:00:00

  • A micro-gap, air-filled ionisation chamber as a detector for criticality accident dosimetry.

    abstract::A micro-gap air-filled ionisation chamber was designed for criticality dosimetry. The special feature of the chamber is its very small gap between electrodes of only 0.3 mm. This prevents ion recombination at high dose rates and minimises the influence of gas on secondary particles spectrum. The electrodes are made of...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nct323

    authors: Murawski Ł,Zielczyński M,Golnik N,Gryziński MA

    更新日期:2014-10-01 00:00:00

  • Contribution of indirect effects to clustered damage in DNA irradiated with protons.

    abstract::Protons are the dominant particles both in galactic cosmic rays and in solar particle events and, furthermore, proton irradiation becomes increasingly used in tumour treatment. It is believed that complex DNA damage is the determining factor for the consequent cellular response to radiation. DNA plasmid pBR322 was irr...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncv159

    authors: Pachnerová Brabcová K,Štěpán V,Karamitros M,Karabín M,Dostálek P,Incerti S,Davídková M,Sihver L

    更新日期:2015-09-01 00:00:00

  • Ratio of aerosol and gases of radioactive chlorine and particle size distribution of aerosol formed by high-energy proton irradiation.

    abstract::To estimate internal doses due to the inhalation of radionuclides produced by the nuclear spallation of the air nuclei in high-energy proton accelerator facilities, the physicochemical properties of radionuclides are very important. Thus, the ratio of aerosol and gases of 38Cl and 39Cl formed by irradiating argon gas-...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm475

    authors: Yokoyama S,Sato K,Manabe K,Noguchi H,Kaneko H,Oki Y,Iida T,Tanaka S

    更新日期:2007-01-01 00:00:00

  • Development of a new passive integral dosemeter for gamma ray monitoring using an imaging plate.

    abstract::A new passive integral dosemeter for gamma ray monitoring is being developed using an imaging plate (IP). In the application of IPs to dosimetry, a fading effect causes serious problems. The fading is considered to be caused by the recombination or holes and charges trapped shallowly in the F centres, which have sever...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006396

    authors: Ohuchi H,Yamadera A,Baba M

    更新日期:2003-01-01 00:00:00

  • Soil gas radon measurements in a region of the Bohemian Massif: investigations in the framework of an Austrian pilot study.

    abstract::Soil gas radon measurements are carried out in a pilot study in three municipalities in Upper Austria. The selected municipalities are characterised by a high radon potential. Sixty measuring sites--well distributed over the region and over the different geological areas--were selected. Additionally, the permeability ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncr089

    authors: Seidel C,Baumgartner A,Ringer W,Gräser J,Friedmann H,Kaineder H,Maringer FJ

    更新日期:2011-05-01 00:00:00

  • Gamma-ray emitting test sources for Portal Monitors used for homeland security.

    abstract::The National Institute of Standards and Technology developed a new set of test sources for testing of portal monitors against the ANSI standard N42.35-2004. The design and source specifications are provided in this work. ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch422

    authors: Lucas L,Pibida L,Unterweger M,Karam L

    更新日期:2005-01-01 00:00:00

  • Modelling the energy-loss mechanism of charged particles in organic solids.

    abstract::The present study examines the energy-loss mechanism of charged particles in organic solids as determined by the inelastic interactions with the electronic sub-system of the target. The dielectric approach was applied to non-conducting valence electrons while an appropriate binary collision theory was used for core-el...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a005836

    authors: Emfietzoglou D

    更新日期:2002-01-01 00:00:00

  • IDACstar: A MCNP Application to Perform Realistic Dose Estimations from Internal or External Contamination of Radiopharmaceuticals.

    abstract::A Monte Carlo-based stand-alone program, IDACstar (Internal Dose Assessment by Computer), was developed, dedicated to perform radiation dose calculations using complex voxel simulations. To test the program, two irradiation situations were simulated, one hypothetical contamination case with 600 MBq of 99mTc and one ex...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncw221

    authors: Ören Ü,Hiller M,Andersson M

    更新日期:2017-04-28 00:00:00

  • Collaboration of local government and experts responding to increase in environmental radiation level due to the nuclear disaster: focusing on their activities and latest radiological discussion.

    abstract::Activities were introduced in Kashiwa city in the Tokyo metropolitan area to correspond to the elevated environmental radiation level after the disaster of the Fukushima Daiichi nuclear power plant. These were based on a strong cooperation between local governments and experts. Ambient dose rate and radioactivity of f...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncv279

    authors: Iimoto T,Nunokawa J,Fujii H,Takashima R,Hashimoto M,Fukuhara T,Yajima T,Matsuzawa H,Kurosawa K,Yanagawa Y,Someya S

    更新日期:2015-11-01 00:00:00

  • Photoneutron and capture gamma dose equivalent for different room and maze layouts in radiation therapy.

    abstract::In this paper the effect of treatment room and maze layout on the photoneutron and capture gamma dose equivalent in the maze was studied. MCNPX Monte Carlo (MC) code was used to simulate the Varian 2100 C/D Clinac 18 MV and four different room layouts. Two analytical methods, Wu-McGinley and McGinley, were used for do...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncp303

    authors: Mesbahi A,Ghiasi H,Mahdavi SR

    更新日期:2010-08-01 00:00:00

  • DETERMINATION OF THE TOTAL EFFECTIVE DOSE OF EXTERNAL AND INTERNAL EXPOSURE BY DIFFERENT IONIZING RADIATION SOURCES.

    abstract::The purpose of the research is to develop an integrated technique for determining the effective dose (E) of external and internal exposure by different sources of ionizing radiation. The proposing technique for determining the total effective dose is based on three methods of calculation. The first one is multiplying ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncz170

    authors: Kudryashev VA,Kim DS

    更新日期:2019-12-31 00:00:00

  • Field tests using radioactive matter 2.

    abstract::Results of field tests with explosive dispersal of a radioactive substance (RaS) are presented. The paper deals with tests exploiting artificial obstacles as a continuation and expansion of the tests used in this study performed in free area described previously. The essential goal of the tests was to estimate the dis...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncs209

    authors: Rulik P,Prouza Z,Hovorka J,Beckova V,Cespirova I,Fronka A,Helebrant J,Hulka J,Kuca P,Skrkal J

    更新日期:2013-04-01 00:00:00

  • A Monte-Carlo code for the detailed simulation of electron and light-ion tracks in condensed matter.

    abstract::In an effort to understand the basic mechanism of the action of charged particles in solid radiation dosimeters, we extend our Monte-Carlo code (MC4) to condensed media (liquids/solids) and present new track-structure calculations for electrons and protons. Modeling the energy dissipation process is based on a model d...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci671

    authors: Emfietzoglou D,Papamichael G,Karava K,Androulidakis I,Pathak A,Phillips GW,Moscovitch M,Kostarelos K

    更新日期:2006-01-01 00:00:00

  • The effect of Mg, Cu and P impurities on dose response of LiF:Mg,Cu,P phosphors: simulation versus experiments.

    abstract::In this research, the effect of magnesium (Mg), copper (Cu) and phosphorus (P) impurities on dosimetry response of LiF:Mg,Cu,P phosphors is studied experimentally and by the simulation procedure. In the experimental procedure, LiF:Mg,Cu,P phosphors in the powder form were synthesised by chemical co-precipitation metho...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncv002

    authors: Mohammadi K,Khayat O,Afarideh H

    更新日期:2016-01-01 00:00:00

  • Development of a voxel phantom of Japanese adult male in upright posture.

    abstract::A Japanese voxel phantom in upright posture, JM2, has been developed on the basis of CT images of a healthy Japanese adult male. Body characteristics of JM2 were compared with those of the supine voxel phantom, JM, previously developed using CT images of the same person. Differences were found in the shapes of the spi...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm272

    authors: Sato K,Noguchi H,Endo A,Emoto Y,Koga S,Saito K

    更新日期:2007-01-01 00:00:00

  • Validation of a Monte Carlo efficiency calibration procedure for a partial body counter system with a voxel model of the LLNL torso phantom.

    abstract::Virtual models of real phantoms used with Monte Carlo methods facilitate the calibration and other studies associated with whole-body and partial-body counting systems. In this investigation, a voxel model of an LLNL torso phantom, available physically in the in vivo laboratory at KIT, was created from computed tomogr...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncp030

    authors: Hegenbart L,Marzocchi O,Breustedt B,Urban M

    更新日期:2009-02-01 00:00:00

  • Development of an electrolysis system for tritium enrichment in superficial water samples.

    abstract::Tritium present in the environment gradually decreased in the last decades and nowadays it has reached extremely low activity concentrations. The purpose of the present work is the implementation of a tritium enrichment system in water samples using electrolytic techniques and pure nickel and iron electrodes. In the p...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncp244

    authors: Garbarino G,Magnoni M,Bertino S,Losana MC

    更新日期:2009-12-01 00:00:00

  • Fetal radiation dose in computed tomography.

    abstract::The connection between recorded volumetric CT dose index (CTDI vol) and determined mean fetal dose (Df) was examined from metal-oxide-semiconductor field-effect transistor dose measurements on an anthropomorphic female phantom in four stages of pregnancy in a 64-slice CT scanner. Automated tube current modulation kept...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncv097

    authors: Kelaranta A,Kaasalainen T,Seuri R,Toroi P,Kortesniemi M

    更新日期:2015-07-01 00:00:00

  • Transition from screen-film to computed radiography in a paediatric hospital: the missing link towards optimisation.

    abstract::In paediatrics, the risks associated with ionising radiation should be a major concern, due to children's higher susceptibility to radiation effects. Measure entrance skin dose (ESD) in chest and pelvis X-ray projections and compare the results with the 'European guidelines on quality criteria for diagnostic radiograp...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncr355

    authors: Paulo G,Santos J,Moreira A,Figueiredo F

    更新日期:2011-09-01 00:00:00

  • DNA fragments induction in human fibroblasts by radiations of different qualities.

    abstract::Experimental data on DNA double strand break (DSB) induction in human fibroblasts (AG1522), following irradiation with several radiation qualities, namely gamma rays, 0.84 MeV protons, 58.9 MeV u(-1) carbon ions, iron ions of 115 MeV u(-1), 414 MeV u(-1), 1 GeV u(-1), and 5 GeV u(-1), are presented. DSB yields were me...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncl389

    authors: Esposito G,Belli M,Campa A,Cherubini R,Cuttone G,Dini V,Furusawa Y,Gerardi S,Simone G,Sorrentino E,Tabocchini MA

    更新日期:2006-01-01 00:00:00

  • RADIOACTIVE REMEDIATION OF AQUATIC ECOSYSTEMS USING MICROALGAE.

    abstract::Radionuclides that have entered the environment through nuclear weapon tests, nuclear accidents or other human activities represent an ecological hazard. Many decontamination techniques are technically and financially demanding and often not environmentally beneficial. A suitable alternative is bioremediation techniqu...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncz221

    authors: Galanda D,Tatarová D,Kuruc J,Gaálová B,Slimáková J

    更新日期:2019-12-31 00:00:00

  • Variability of radiocaesium inventory in Fukushima soil cores from one site measured at different times.

    abstract::The Fukushima Daiichi Nuclear Power Plant (FDNPP) accident has resulted in the deposition of radioactive contamination of soils mainly by (134)Cs and (137)Cs. The contaminated areas are of a great concern since external radiation may lead to significant long-term doses to humans and animals. External dose rate above g...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncv276

    authors: Mishra S,Sahoo SK,Arae H,Sorimachi A,Hosoda M,Tokonami S,Ishikawa T

    更新日期:2015-11-01 00:00:00

  • Microdosimetric evaluation of the neutron field for BNCT at Kyoto University reactor by using the PHITS code.

    abstract::In this study, microdosimetric energy distributions of secondary charged particles from the (10)B(n,α)(7)Li reaction in boron-neutron capture therapy (BNCT) field were calculated using the Particle and Heavy Ion Transport code System (PHITS). The PHITS simulation was performed to reproduce the geometrical set-up of an...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq511

    authors: Baba H,Onizuka Y,Nakao M,Fukahori M,Sato T,Sakurai Y,Tanaka H,Endo S

    更新日期:2011-02-01 00:00:00

  • A pilot study of the dependence of radon concentration on the tectonic structures, using simple geophysical methods.

    abstract::It is well known that there are great variations in radon concentrations in the soil gas on building sites. The concentration may sometimes vary by more than two orders of magnitude. The tectonic structure of the bedrock is one of the factors that influence the intensity of the radon outflow. The simple ARES geophysic...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncr070

    authors: Thinova L,Fronka A,Rovenska K

    更新日期:2011-05-01 00:00:00

  • Radical distributions in ammonium tartrate single crystals exposed to photon and neutron beams.

    abstract::The radiation therapy carried out by means of heavy charged particles (such as carbon ions) and neutrons is rapidly becoming widespread worldwide. The success of these radiation therapies relies on the high density of energy released by these particles or by secondary particles produced after primary interaction with ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncu033

    authors: Marrale M,Longo A,Barbon A,Brustolon M,Brai M

    更新日期:2014-10-01 00:00:00

  • Analysis of the reliability of the local effect model for the use in carbon ion treatment planning systems.

    abstract::In radiotherapy with carbon ions, biological effects of treatments have to be predicted. For this purpose, one of the most used models is the local effect model (LEM) developed at the Gesellschaft für Schwerionenforschung (GSI), Germany. At the Istituto Nazionale di Fisica Nucleare, Italy, the reliability of the last ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq407

    authors: Russo G,Attili A,Bourhaleb F,Marchetto F,Peroni C,Schmitt E,Bertrand D

    更新日期:2011-02-01 00:00:00