Soil gas radon measurements in a region of the Bohemian Massif: investigations in the framework of an Austrian pilot study.

Abstract:

:Soil gas radon measurements are carried out in a pilot study in three municipalities in Upper Austria. The selected municipalities are characterised by a high radon potential. Sixty measuring sites--well distributed over the region and over the different geological areas--were selected. Additionally, the permeability of the soil was determined where the soil gas samples were taken and at various sites where soil samples were analysed by gamma spectrometry. Long-term soil-gas radon concentration measurements are carried out at several sites to study the long-term behaviour of radon activity concentration in soil, the influence of meteorological parameters and seasonal variations. The final goal of the project is to correlate the collected data with geological data and indoor radon concentration. First results of this ongoing study are presented and discussed.

journal_name

Radiat Prot Dosimetry

authors

Seidel C,Baumgartner A,Ringer W,Gräser J,Friedmann H,Kaineder H,Maringer FJ

doi

10.1093/rpd/ncr089

subject

Has Abstract

pub_date

2011-05-01 00:00:00

pages

329-32

issue

2-3

eissn

0144-8420

issn

1742-3406

pii

ncr089

journal_volume

145

pub_type

杂志文章
  • Uncertainty evaluation of radon measurements with LR115 detector and spark counter.

    abstract::To evaluate the uncertainties for nuclear track detectors used in radon measurements, a full understanding is required of the physical phenomena involved and the behaviour of the instruments utilised in the measuring process. As it concerns the LR115 nuclear track detector, an overall evaluation of uncertainty was giv...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch361

    authors: Campi F,Caresana M,Ferrarini M,Garlati L,Palermo M,Rusconi R

    更新日期:2004-01-01 00:00:00

  • Hearing aids' electromagnetic immunity to environmental RF fields.

    abstract::In this work, the electromagnetic interference on hearing aids was evaluated. Electromagnetic (EM) immunity tests on different types of hearing aids were carried out, using signals of intensity and modulation comparable to those present in the environment. The purpose of this work is to characterise the interference, ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch052

    authors: Facta S,Benedetto A,Anglesio L,d'Amore G

    更新日期:2004-01-01 00:00:00

  • 131I DOSE ESTIMATION FROM INTAKE OF TAP WATER IN THE EARLY PHASE AFTER FUKUSHIMA DAIICHI NUCLEAR POWER PLANT ACCIDENT.

    abstract::In March 2011, the Fukushima Daiichi Nuclear Power Plant Accident occurred and a large amount of radionuclides was released. To study its effect, we estimated the internal exposure due to intake of tap water in the early phase after the accident. As the number of measured values of tap water following the accident was...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncx208

    authors: Kawai M,Yoshizawa N,Suzuki G

    更新日期:2018-04-01 00:00:00

  • Radiation safety assessment of a system of small reactors for distributed energy.

    abstract::A passively safe small reactor for a distributed energy system, PSRD, is an integral type of light-water reactor with a thermal output of 100 or 300 MW aimed to be used for supplying district heat, electricity to small grids, and so on. Candidate locations for the PSRD as a distributed energy source are on-ground, dee...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci208

    authors: Odano N,Ishida T

    更新日期:2005-01-01 00:00:00

  • The TSL neutron beam facility.

    abstract::A new quasi-monoenergetic neutron beam facility has been constructed at The Svedberg Laboratory (TSL) in Uppsala, Sweden. Key features include a neutron energy range of 11-175 MeV, high fluxes, user flux control, flexible neutron field size and shape, and spacious and easily accessible user area. The first results of ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm006

    authors: Prokofiev AV,Blomgren J,Byström O,Ekström C,Pomp S,Tippawan U,Ziemann V,Osterlund M

    更新日期:2007-01-01 00:00:00

  • DEVELOPMENT OF A NEW SECONDARY STANDARD FOR H*(10).

    abstract::A secondary standard for ambient dose equivalent, H*(10), is necessary for the dissemination of the unit Sievert (Sv), but there is no such standard commercially available currently. Furthermore, the measurement of H*(10) instead of calculating H*(10) from air kerma and conversion coefficients is needed for unknown ra...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncz296

    authors: Bairlein K,Behnke B,Hupe O

    更新日期:2020-06-24 00:00:00

  • Biokinetics of radionuclides and treatment of accidental intakes.

    abstract::This paper describes the objectives and reviews the progress of EULEP Working Party 5, convened under the auspices of the European Union's Fifth Framework Programme, to 'cluster' two EU-supported contracts, Biokinetics and Dosimetry of Internal Contamination (BIODOS (EU Contract FIS5-1999-00214)) and Radionuclide Biok...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006318

    authors: Taylor DM,Stradling GN,Ménétrier F

    更新日期:2003-01-01 00:00:00

  • Ratio of aerosol and gases of radioactive chlorine and particle size distribution of aerosol formed by high-energy proton irradiation.

    abstract::To estimate internal doses due to the inhalation of radionuclides produced by the nuclear spallation of the air nuclei in high-energy proton accelerator facilities, the physicochemical properties of radionuclides are very important. Thus, the ratio of aerosol and gases of 38Cl and 39Cl formed by irradiating argon gas-...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm475

    authors: Yokoyama S,Sato K,Manabe K,Noguchi H,Kaneko H,Oki Y,Iida T,Tanaka S

    更新日期:2007-01-01 00:00:00

  • Dose-image quality optimisation in digital chest radiography.

    abstract::A range of techniques has been developed in conventional radiography for the chest, because of technical difficulties in imaging the wide variation of tissue densities. These techniques can differ significantly in tube potential selection, for scatter reduction and in application of manual or automatic exposure contro...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch546

    authors: Doyle P,Martin CJ,Gentle D

    更新日期:2005-01-01 00:00:00

  • TWO NEW SINGLE-EXPOSURE, MULTI-DETECTOR NEUTRON SPECTROMETERS FOR RADIATION PROTECTION APPLICATIONS IN WORKPLACE MONITORING.

    abstract::This communication describes two new instruments, based on multiple active thermal neutron detectors arranged within a single moderator, that permit to unfold the neutron spectrum (from thermal to hundreds of MeV) and to determine the corresponding integral quantities with only one exposure. This makes them especially...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncw349

    authors: Gómez-Ros JM,Bedogni R,Bortot D,Domingo C,Esposito A,Introini MV,Lorenzoli M,Mazzitelli G,Moraleda M,Pola A,Sacco D

    更新日期:2017-04-01 00:00:00

  • Non-human Primate Total-body Irradiation Model with Limited and Full Medical Supportive Care Including Filgrastim for Biodosimetry and Injury Assessment.

    abstract::An assessment of multiple biomarkers from radiation casualties undergoing limited- or full-supportive care including treatment with filgrastim is critical to develop rapid and effective diagnostic triage strategies. The efficacy of filgrastim with full-supportive care was compared with results with limited-supportive ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncw176

    authors: Ossetrova NI,Blakely WF,Nagy V,McGann C,Ney PH,Christensen CL,Koch AL,Gulani J,Sigal GB,Glezer EN,Hieber KP

    更新日期:2016-12-01 00:00:00

  • Development and validation of a technique for the determination of 226Ra and 228Ra by liquid scintillation in liquid samples.

    abstract::Radium isotopes are dispersed in the environment according to their physicochemical characteristics. Considering their long half-lives and radiological effects, (226)Ra and (228)Ra are very important issues in radiological protection. In Brazil, radium isotopes represent an exposure problem both in nuclear fuel cycle ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq434

    authors: Fernandes PC,Sousa WO,Julião LM,Dantas BM

    更新日期:2011-03-01 00:00:00

  • Experimental simulation of A-bomb gamma ray spectra for radiobiology studies.

    abstract::Improved radiation protection of humans requires a better understanding of the mechanisms of radiation action and accurate estimates of radiation risk for both internal and external radiations. The Japanese atomic bomb survivors represent one of the most important sources of human data on the late carcinogenic effects...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006532

    authors: Pattison JE,Hugtenburg RP,Charles MW,Beddoe AH

    更新日期:2001-01-01 00:00:00

  • The response of a bonner sphere spectrometer to charged hadrons.

    abstract::Bonner sphere spectrometers (BSSs) are employed in neutron spectrometry and dosimetry since many years. Recent developments have seen the addition to a conventional BSS of one or more detectors (moderator plus thermal neutron counter) specifically designed to improve the overall response of the spectrometer to neutron...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch187

    authors: Agosteo S,Dimovasili E,Fassò A,Silari M

    更新日期:2004-01-01 00:00:00

  • A quality control programme for medical X-ray films in India.

    abstract::Medical X-ray films are continued to be the major image receptors in diagnostic radiology in India. About 9×10⁶ m² of medical X-ray films are used per annum for diagnostic imaging in India, and its magnitude may further increase as the number of diagnostic X-ray units is increasing rapidly. A national quality control ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq595

    authors: Sharma R,Sharma SD

    更新日期:2012-01-01 00:00:00

  • Thermoluminescent dosemeters based on TLD-500 detectors for control of neutron fields.

    abstract::The results of a study dealing with detection of neutrons in thermoluminescent (TL) photon radiation detectors, type TLD-500, based on an anion-defective corundum have been reported. The detection method uses the transformation of neutron radiation into gamma radiation arising when neutrons are captured by cadmium nuc...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a005951

    authors: Nikiforov SV,Kortov VS,Milman II

    更新日期:2002-01-01 00:00:00

  • Transfer of alkaline earth elements in mothers' milk and doses from 45Ca, 90Sr and 226Ra.

    abstract::An international programme of work is currently under way to develop methods for calculating doses to infants from ingestion of radionuclides present in mothers' milk. This paper considers the special case of the alkaline earth elements. Models have been developed for 45Ca, 90Sr and 226Ra and the sensitivity of result...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006239

    authors: Smith TJ,Phipps AW,Fell TP,Harrison JD

    更新日期:2003-01-01 00:00:00

  • In vivo thyroid 131I monitoring system using an imaging plate.

    abstract::The counting efficiency and detection limit of an in vivo thyroid 131I monitoring system using an imaging plate (IP) were estimated using an anthropomorphic thyroid neck phantom. The counting efficiency of the IP system was approximately constant for thyroid volumes between 11.7 and 20 ml and neck diameters between 10...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006025

    authors: Hirota M,Saze T,Nishizawa K

    更新日期:2002-01-01 00:00:00

  • Effective dose to a patient undergoing coronary angiography.

    abstract::Detailed data relating to patient dose have been acquired for 18, randomly chosen, patients undergoing coronary angiographies. During the procedure, dose-area product (DAP), kV and beam collimation were recorded for each projection. Total DAP, fluoroscopy time and number of cine frames were also noted. Patient effecti...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006466

    authors: Lobotessi H,Karoussou A,Neofotistou V,Louisi A,Tsapaki V

    更新日期:2001-01-01 00:00:00

  • Air kerma to HP(3) conversion coefficients for photons from 10 keV to 10 MeV, calculated in a cylindrical phantom.

    abstract::In the framework of the ORAMED project (Optimization of RAdiation protection for MEDical staff), funded by the European Union Seventh Framework Programme, different studies were aimed at improving the quality of radiation protection in interventional radiology and nuclear medicine. The main results of the project were...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncs269

    authors: Gualdrini G,Bordy JM,Daures J,Fantuzzi E,Ferrari P,Mariotti F,Vanhavere F

    更新日期:2013-05-01 00:00:00

  • Canadian national internal dosimetry performance testing programme: results of the pilot programme.

    abstract::This paper describes the design and construction of a new performance testing programme that was implemented in Canada in 2008. The Canadian Regulator (Canadian Nuclear Safety Commission) had determined that their licensees, in addition to participating in the existing in vivo and in vitro performance tests, needed to...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncp088

    authors: Kramer GH

    更新日期:2009-06-01 00:00:00

  • A new position recording system for the partial-body counter at KIT.

    abstract::The position of detectors used for partial-body counters relative to a measured person has considerable influence on the counting efficiency of low-energy photon emitters. To minimise reading errors and enhance reproducibility of position data, an electronic position recording system was installed in the partial-body ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq416

    authors: Hegenbart L,Breustedt B

    更新日期:2011-03-01 00:00:00

  • A study of the irradiation temperature coefficient for L-alanine and DL-alanine dosemeters.

    abstract::Alanine dosimetry is now well established both as a reference and routine dosemeter for industrial irradiation processing. Accurate dosimetry under the relatively harsh conditions of industrial processing requires a characterisation of the parameters that influence the dosemeter response. The temperature of the doseme...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci543

    authors: Desrosiers MF,Lin M,Cooper SL,Cui Y,Chen K

    更新日期:2006-01-01 00:00:00

  • Would children be adequately protected by existing intervention levels during a radionuclear emergency?

    abstract::The question arises as to whether radiation standards and guidelines set for adults are sufficiently protective of children. To answer this question, published literature values have been used to calculate radiation doses to children and adults from external and internal exposure to a suite of 30 radionuclides commonl...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq202

    authors: Tracy BL

    更新日期:2010-11-01 00:00:00

  • International action plan on the radiation protection of patients.

    abstract::Realising that the major part of radiation protection efforts had been directed for over half a century at radiation protection of workers, and that there are major issues in relation to medical exposure, which contributes to over 95 % of the dose to the global population from man-made sources, with increasing individ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncr258

    authors: Rehani MM,Holmberg O,Ortiz López P,Mettler F

    更新日期:2011-09-01 00:00:00

  • Dosimetry of a set-up for the exposure of newborn mice to 2.45-GHZ WiFi frequencies.

    abstract::This work describes the dosimetry of a two waveguide cell system designed to expose newborn mice to electromagnetic fields associated with wireless fidelity signals in the frequency band of 2.45 GHz. The dosimetric characterisation of the exposure system was performed both numerically and experimentally. Specific meas...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq129

    authors: Pinto R,Lopresto V,Galloni P,Marino C,Mancini S,Lodato R,Pioli C,Lovisolo GA

    更新日期:2010-08-01 00:00:00

  • Discrimination between natural and other gamma ray sources from environmental gamma ray dose rate monitoring data.

    abstract::In this study, a method to discriminate between natural and other γ-ray sources from environmental γ-ray dose rate monitoring data was developed, and it was successfully applied to actual monitoring data around nuclear facilities. The environmental dose rate is generally monitored by NaI(Tl) detector systems in the lo...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncv265

    authors: Kumagai K,Ookubo H,Kimura H

    更新日期:2015-11-01 00:00:00

  • EFFECT OF PATIENT SIZE, ANATOMICAL LOCATION AND MODULATION STRENGTH ON DOSE DELIVERED AND IMAGE-QUALITY ON CT EXAMINATION.

    abstract::To study the effect of patient size, anatomical location and modulation strength (MS) on image-quality and delivered dose of CT scans acquired with automatic-exposure-control system (AEC). Four anthropomorphic phantoms (three paediatric and one thin adult) were studied, and normal and obese adults were simulated by pl...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncx055

    authors: Greffier J,Larbi A,Macri F,Beregi JP,Pereira F

    更新日期:2017-12-01 00:00:00

  • Radiation protection at Hadron therapy facilities.

    abstract::The Italian National Centre for Oncological Hadrontherapy is currently under construction in Pavia. It is designed for the treatment of deep-seated tumours (up to a depth of 27 cm of water equivalent) with proton and C-ion beams as well as for both clinical and radiobiological research. The particles will be accelerat...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncr242

    authors: Pelliccioni M

    更新日期:2011-07-01 00:00:00

  • Experimental simulation of A-bomb gamma ray spectra: revisited.

    abstract::It has been reported recently that the A-bomb gamma ray spectra received by the colon of the average Japanese survivor of Hiroshima and Nagasaki may be experimentally simulated using a hospital-based Philips SL15 linear accelerator. The simulated A-bomb gamma radiation may be used in radiobiology experiments to determ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch320

    authors: Pattison JE,Payne LC,Hugtenburg RP,Beddoe AH,Charles MW

    更新日期:2004-01-01 00:00:00