Radiation safety assessment of a system of small reactors for distributed energy.

Abstract:

:A passively safe small reactor for a distributed energy system, PSRD, is an integral type of light-water reactor with a thermal output of 100 or 300 MW aimed to be used for supplying district heat, electricity to small grids, and so on. Candidate locations for the PSRD as a distributed energy source are on-ground, deep underground, and in a seaside pit in the vicinity of the energy consumption area. Assessments of the radiation safety of a PSRD were carried out for three cases corresponding to normal operation, shutdown and a hypothetical postulated accident for several siting candidates. Results of the radiation safety assessment indicate that the PSRD design has sufficient shielding performance and capability and that the exposure to the general public is very low in the case of a hypothetical accident.

journal_name

Radiat Prot Dosimetry

authors

Odano N,Ishida T

doi

10.1093/rpd/nci208

keywords:

subject

Has Abstract

pub_date

2005-01-01 00:00:00

pages

95-9

issue

1-4

eissn

0144-8420

issn

1742-3406

pii

115/1-4/95

journal_volume

115

pub_type

杂志文章
  • PARALLELISATION OF THE MODEL-BASED ITERATIVE RECONSTRUCTION ALGORITHM DIRA.

    abstract::New paradigms for parallel programming have been devised to simplify software development on multi-core processors and many-core graphical processing units (GPU). Despite their obvious benefits, the parallelisation of existing computer programs is not an easy task. In this work, the use of the Open Multiprocessing (Op...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncv430

    authors: Örtenberg A,Magnusson M,Sandborg M,Alm Carlsson G,Malusek A

    更新日期:2016-06-01 00:00:00

  • Ratio of aerosol and gases of radioactive chlorine and particle size distribution of aerosol formed by high-energy proton irradiation.

    abstract::To estimate internal doses due to the inhalation of radionuclides produced by the nuclear spallation of the air nuclei in high-energy proton accelerator facilities, the physicochemical properties of radionuclides are very important. Thus, the ratio of aerosol and gases of 38Cl and 39Cl formed by irradiating argon gas-...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm475

    authors: Yokoyama S,Sato K,Manabe K,Noguchi H,Kaneko H,Oki Y,Iida T,Tanaka S

    更新日期:2007-01-01 00:00:00

  • COMPARISON STUDY OF VARIOUS PLASTICS AS THE WALL MATERIAL OF THGEM-BASED MICRODOSEMETERS FOR FAST NEUTRON MEASUREMENTS.

    abstract::To find appropriate substitutions for the expensive plastics of A-150 and rexolite used in the construction of thick gas electron multiplier (THGEM)-based tissue-equivalent proportional counters, in the present work, the responses of a THGEM-based microdosimetric detector made of A-150 and rexolite and three others co...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncw008

    authors: Moslehi A,Raisali G,Lamehi M

    更新日期:2017-04-15 00:00:00

  • Variations in radon concentration in groundwater of Kumaon Himalaya, India.

    abstract::The radon content in groundwater sources depends on the radium concentration in the rock of the aquifer. Radon was measured in water in many parts of the world, mostly for the risk assessment due to consumption of drinking water. The exposure to radon through drinking water is largely by inhalation and ingestion. Airb...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncs186

    authors: Bourai AA,Gusain GS,Rautela BS,Joshi V,Prasad G,Ramola RC

    更新日期:2012-11-01 00:00:00

  • Optimisation of the body composition analyser using the gamma shield and improvement of accuracy using ORNL anthropomorphic phantoms.

    abstract::The analysis of body elements using the prompt gamma rays neutron activation method is a very useful and highly accurate method Lone, M. A., Mughabghab, S. F. and Paviotti-Corcuera, R. Development of a database for prompt gamma-ray neutron activation analysis. Summary Report of the Second Research Coordination Meeting...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nct004

    authors: Araghian N,Rafat-Motavalli L,Miri-Hakimabad H

    更新日期:2013-07-01 00:00:00

  • ISO 4037:2019 VALIDATION OF RADIATION QUALITIES BY MEANS OF HALF-VALUE LAYER AND HP(10) DOSIMETRY.

    abstract::Radiation qualities were characterised and validated at the fully automated X-ray calibration facility of the Individual Monitoring Service at Helmholtz Zentrum München by using half-value layer and Hp(10) dosimetry approaches specified in the updated ISO 4037:2019 standard. As the ISO 4037 contains a somewhat vague d...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncz185

    authors: Bandalo V,Greiter MB,Brönner J,Hoedlmoser H

    更新日期:2019-12-31 00:00:00

  • Characterization of neutron reference fields at US Department of Energy calibration fields.

    abstract::The Health Physics Measurements Group at the Los Alamos National Laboratory (LANL) has initiated a study of neutron reference fields at selected US Department of Energy (DOE) calibration facilities. To date, field characterisation has been completed at five facilities. These fields are traceable to the National Instit...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm012

    authors: Olsher RH,McLean TD,Mallett MW,Seagraves DT,Gadd MS,Markham RL,Murphy RO,Devine RT

    更新日期:2007-01-01 00:00:00

  • Electron spin resonance evaluation of pure CaSO4 and as a phosphor doped with P and Dy.

    abstract::Polycrystalline CaSO4 powder, doped with different elements but mainly rare earths, is one of the most interesting thermoluminescent (TL) materials. Although many electron spin resonance (ESR) analyses have been reported for these materials few studies have been published about the potential of CaSO4 for ESR dosimetry...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006047

    authors: de Jesus EF,Rossi AM,Lopes RT

    更新日期:2002-01-01 00:00:00

  • A THIN-LAYER LIF THERMOLUMINESCENCE DOSEMETER SYSTEM WITH FAST READOUT FOR THE USE IN PERSONAL DOSIMETRY SERVICES.

    abstract::A newly developed thermoluminescence dosemeter system is presented that is suitable for application in fields where personal monitoring of a large number of users is required. The system presented here is intended to be used as the upcoming main dosemeter for whole body dosimetry at the dosimetry service of the MPA NR...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncv478

    authors: Walbersloh J,Busch F

    更新日期:2016-09-01 00:00:00

  • Microdosimetric modelling of the response of thermoluminescence detectors to low- and high-LET ionising radiation.

    abstract::The microdosimetric one hit detector model was applied to calculate the dose response, energy response and relative thermoluminescence (TL) efficiency, eta, of high sensitive LiF:Mg,Cu,P and Al(2)O(3):C detectors after their irradiations by X rays, gamma rays, beta electrons and heavy charged particles (HCP). Microdos...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncl467

    authors: Olko P,Bilski P,Budzanowski M,Czopyk L,Swakon J,Waligorski MP

    更新日期:2006-01-01 00:00:00

  • Neutron spectra unfolding in Bonner spheres spectrometry using neural networks.

    abstract::The neural network method has been used for the unfolding of neutron spectra in neutron spectrometry by Bonner spheres. A back propagation algorithm was used for training of neural networks. 4 mm x 4 mm bare LiI (Eu) and in a polyethylene sphere set: 2, 3, 4, 5, 6, 7, 8, 10, 12, 18 inch diameter have been used for unf...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006158

    authors: Kardan MR,Setayeshi S,Koohi-Fayegh R,Ghiassi-Nejad M

    更新日期:2003-01-01 00:00:00

  • Analysis and improvement of cyclotron thallium target room shield.

    abstract::Because of high neutron and gamma-ray intensities generated during bombardment of a thallium-203 target, a thallium target-room shield and different ways of improving it have been investigated. Leakage of neutron and gamma ray dose rates at various points behind the shield are calculated by simulating the transport of...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncn099

    authors: Hajiloo N,Raisali G,Aslani G

    更新日期:2008-01-01 00:00:00

  • Preliminary study of using imaging plates to map skin dose of patients in interventional radiology procedures.

    abstract::A method using europium-doped BaFBr imaging plates (IPs) has been studied for mapping entrance skin doses during interventional radiology (IR); the mapping is useful for detecting overlap between irradiation fields and determining the most exposed skin areas. IPs, which are two-dimensional radiation sensors made of ph...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch468

    authors: Ohuchi H,Satoh T,Eguchi Y,Mori K

    更新日期:2005-01-01 00:00:00

  • Radical distributions in ammonium tartrate single crystals exposed to photon and neutron beams.

    abstract::The radiation therapy carried out by means of heavy charged particles (such as carbon ions) and neutrons is rapidly becoming widespread worldwide. The success of these radiation therapies relies on the high density of energy released by these particles or by secondary particles produced after primary interaction with ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncu033

    authors: Marrale M,Longo A,Barbon A,Brustolon M,Brai M

    更新日期:2014-10-01 00:00:00

  • Analysis of neutron and photon response of a TLD-ALBEDO personal dosemeter on an ISO slab phantom using TRIPOLI-4.3 Monte Carlo code.

    abstract::TRIPOLI-4.3 Monte Carlo transport code has been used to evaluate the QUADOS (Quality Assurance of Computational Tools for Dosimetry) problem P4, neutron and photon response of an albedo-type thermoluminescence personal dosemeter (TLD) located on an ISO slab phantom. Two enriched 6LiF and two 7LiF TLD chips were used a...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci032

    authors: Lee YK

    更新日期:2005-01-01 00:00:00

  • Nuclear reactions in Monte Carlo codes.

    abstract::The physics foundations of hadronic interactions as implemented in most Monte Carlo codes are presented together with a few practical examples. The description of the relevant physics is presented schematically split into the major steps in order to stress the different approaches required for the full understanding o...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006788

    authors: Ferrari A,Sala PR

    更新日期:2002-01-01 00:00:00

  • COMMITTED EFFECTIVE DOSE DUE TO THE INTAKE OF 40K, 226Ra, 228Ra AND 228Th CONTAINED IN FOODS INCLUDED IN THE DIET OF THE RIO DE JANEIRO CITY POPULATION, BRAZIL.

    abstract::Annual effective dose due to the consumption of 40K, 226Ra, 228Ra and 228Th was estimated from high-resolution gamma spectrometry, food consumption data for the inhabitants of Rio de Janeiro City and dose coefficients published by the ICRP 119. A total of 31 samples of cereals, grains, vegetables, flours, liquid and p...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncx310

    authors: Lopes JM,Garcêz RWD,Filgueiras RA,Silva AX,Braz D

    更新日期:2018-10-01 00:00:00

  • The history of radon from a Swedish perspective.

    abstract::Beginning in the 16th century, what was later found to be radon was thought to be causing sickness among miners. During the first decades of the 20th century, exposure to radon was seen as being healthy. During the 1940s, 1950s and 1960s researchers thought that the gamma radiation in residences could produce genetic ...

    journal_title:Radiation protection dosimetry

    pub_type: 历史文章,杂志文章,评审

    doi:10.1093/rpd/nch318

    authors: Swedjemark GA

    更新日期:2004-01-01 00:00:00

  • Measurement of patient radiation doses in certain urography procedures.

    abstract::Patients are exposed to significant radiation doses during diagnostic and interventional urologic procedures. This study aimed to measure patient entrance surface air kerma (ESAK) and to estimate the effective dose during intravenous urography (IVU), extracorporeal shock-wave lithotripsy (ESWL), and ascending urethogr...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncv185

    authors: Sulieman A,Barakat H,Zailae A,Abuderman A,Theodorou K

    更新日期:2015-07-01 00:00:00

  • Shielding design of a brachytherapy unit at the Korle Bu teaching hospital in Ghana: comparison of theoretical calculations and experimental study.

    abstract::A theoretical study was carried out to re-evaluate the integrity of the biological shielding of (137)Cs brachytherapy unit at the Korle Bu Teaching Hospital, Ghana, and the results were verified by measurement of the dose rates at selected locations. The primary objective was to determine the current state of protecti...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq001

    authors: Arwui CC,Schandorf C,Nani K,Darko EO,Deatanyah P

    更新日期:2010-06-01 00:00:00

  • Characterization Of A Lanthanum Bromide Detector For Eye Lens Dosimetry At The Candu Nuclear Power Plants Based On Direct Measurements Of The Gamma-Ray Spectra.

    abstract::Gamma-ray spectra were measured using a LaBr$_{3}$(Ce) spectrometer during the outage periods, aiming at quantifying the gamma source term of radiation workers' exposure, at the CANDU nuclear power reactors, for the purposes of eye lens dosimetry. The spectra were measured inside the boiler rooms, of the Bruce Power a...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncaa186

    authors: Laranjeiro AS,Bohra F,Byun SH,Atanackovic J,Hanu AR

    更新日期:2020-12-15 00:00:00

  • Radon progeny in hydrometeors at the earth's surface.

    abstract::During atmospheric thermal inversions, dew and hoarfrost concentrate gamma emitting radionuclides of the short-lived (222)Rn progeny ((214)Pb and (214)Bi), causing an increase in the total natural gamma background from the ground. To highlight this phenomenon, a volcanic zone of high (222)Rn flux was studied during th...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncr402

    authors: Voltaggio M

    更新日期:2012-07-01 00:00:00

  • Spatial distribution of indoor radon in Triveneto (Northern Italy): a geostatistical approach.

    abstract::The study of spatial distribution of the indoor radon has assumed in the last years a lot of interest. The geostatistical techniques turn out to be particularly promising. The present work presents the results of a study where around 4000 indoor radon data from Veneto, Friuli Venezia-Giulia and Alto Adige, collected d...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncp252

    authors: Bertolo A,Bigliotto C,Giovani C,Garavaglia M,Spinella M,Verdi L,Pegoretti S

    更新日期:2009-12-01 00:00:00

  • 131I DOSE ESTIMATION FROM INTAKE OF TAP WATER IN THE EARLY PHASE AFTER FUKUSHIMA DAIICHI NUCLEAR POWER PLANT ACCIDENT.

    abstract::In March 2011, the Fukushima Daiichi Nuclear Power Plant Accident occurred and a large amount of radionuclides was released. To study its effect, we estimated the internal exposure due to intake of tap water in the early phase after the accident. As the number of measured values of tap water following the accident was...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncx208

    authors: Kawai M,Yoshizawa N,Suzuki G

    更新日期:2018-04-01 00:00:00

  • Biophysical analysis of radiation induced initial DNA fragmentation.

    abstract::Production of double strand breaks (DSBs) and double-stranded DNA fragments after irradiation with high energy nitrogen ions was simulated with stochastic track generation and a high-order chromatin structure (HOCS) model representing a segment of interphase chromosome. The non-random distribution of DNA fragments is ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006748

    authors: Khvostunov IK,Andreev SG,Eidelman Y

    更新日期:2002-01-01 00:00:00

  • Evaluation of the radioactivity of the pre-dominant gamma emitters in components used at high-energy proton accelerator facilities.

    abstract::At a high-energy, high-intensity proton accelerator facility, the accelerator components inside the beam-line tunnel and the concrete wall of the tunnel are activated due to beam loss during operation. During maintenance work inside the tunnel, radiation emitted from these activated materials can cause exposure to rad...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncl475

    authors: Numajiri M

    更新日期:2007-01-01 00:00:00

  • Neutron dose distribution at the GSI fragment separator.

    abstract::GSI is operating a facility for the production of rare isotopes. Nuclei are produced by fragmentation or fission of the impinging heavy ions with energies of approximately 1 GeV per nucleon. The major part of the primary beam and the produced nuclei is deposited in the components of the Fragment Separator (FRS) and ge...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch210

    authors: Fehrenbacher G,Festag JG

    更新日期:2004-01-01 00:00:00

  • Methodology for Simple Spot Measurement of Equilibrium Equivalent Radon Concentration.

    abstract::Estimation of the effective inhalation dose of short half-life radon progeny requires the quantification of radon equilibrium equivalent activity concentrations (EEC, Ceq). The aim of the present study is to develop new methodology that focuses on spot measurements to determine EEC from single gross alpha counts and d...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncaa176

    authors: Sakoda A,Ishimori Y,Kanzaki N,Tanaka H

    更新日期:2020-11-13 00:00:00

  • Measurement of the magnetic fields of high-voltage substations (230 kV) in Tehran (Iran) and comparison with the ACGIH threshold limit values.

    abstract::Measurements were made according to IEEE standard 644-1994 at a height of 1 m above floor level. It is concluded that none of the measurements exceeded the ACGIH threshold limit value. Among all control rooms the highest measured density amount is 0.69 μT in the control room of Ozgol substation and the lowest is 0.2 μ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq445

    authors: Fard MS,Nasiri P,Monazzam MR

    更新日期:2011-06-01 00:00:00

  • Full spectrum analysis in environmental monitoring.

    abstract::In environmental radiation monitoring, the time-variable natural gamma radiation background complicates the nuclide identification and analysis of a gamma spectrum. A full spectrum analysis based on the noise adjusted singular value decomposition method for the description of the time-variable background and adjustmen...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncu144

    authors: Reinhardt S

    更新日期:2014-08-01 00:00:00