ISO 4037:2019 VALIDATION OF RADIATION QUALITIES BY MEANS OF HALF-VALUE LAYER AND HP(10) DOSIMETRY.

Abstract:

:Radiation qualities were characterised and validated at the fully automated X-ray calibration facility of the Individual Monitoring Service at Helmholtz Zentrum München by using half-value layer and Hp(10) dosimetry approaches specified in the updated ISO 4037:2019 standard. As the ISO 4037 contains a somewhat vague description of the half-value layer procedure, we extended it to be more constrained and thus less subjective in its implementation. We specify both the measurement and data analysis steps performed in order to provide reproducible half-value layer results and compare the results with the Hp(10) dosimetry-based validation approach specified in the ISO 4037 as an alternative for field validation. Finally, we discuss the implications of our results and the extended procedure on validation and the recent changes to the ISO 4037.

journal_name

Radiat Prot Dosimetry

authors

Bandalo V,Greiter MB,Brönner J,Hoedlmoser H

doi

10.1093/rpd/ncz185

subject

Has Abstract

pub_date

2019-12-31 00:00:00

pages

438-450

issue

4

eissn

0144-8420

issn

1742-3406

pii

5606699

journal_volume

187

pub_type

杂志文章
  • Physical image quality comparison of four types of digital detector for chest radiology.

    abstract::Image quality for similar exposure conditions has been compared for two computed radiography (CR) systems (needle-based and conventional storage phosphor) and two flat-panel (DR) systems from different manufacturers mainly devoted to chest radiology. Image quality was assessed with a contrast-detail object and acrylic...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncn026

    authors: Fernandez JM,Ordiales JM,Guibelalde E,Prieto C,Vano E

    更新日期:2008-01-01 00:00:00

  • RADON SURVEY IN SCHOOL AND ESTIMATION OF EFFECTIVE DOSE USING CORRECTED RADON CONCENTRATION.

    abstract::Radon exposure in schools is different from that in dwellings because the residence pattern is very different each other. So, when effective dose is calculated in schools, different approach should be considered from in dwellings. The aim of this study was to estimate actual effective dose due to inhaled radon conside...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncx216

    authors: Lee ER,Chang BU,Kim YJ

    更新日期:2018-04-01 00:00:00

  • Radiation doses potentially received on-board aeroplanes during recent solar particle events.

    abstract::Because the doses received on-board aeroplanes are now monitored to fulfil legal requirements in some countries, including the European Community, the models to calculate doses received during solar events have left their purely academic status to become a part of operational systems as well. The present work consider...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci356

    authors: Lantos P

    更新日期:2006-01-01 00:00:00

  • CHARACTERISATION AND EVALUATION OF AL2O3:C-BASED OPTICALLY STIMULATED LUMINESCENT DOSEMETER SYSTEM FOR DIAGNOSTIC X-RAYS: PERSONAL AND IN VIVO DOSIMETRY.

    abstract::This study characterises and evaluates an Al2O3:C-based optically stimulated luminescent dosemeter (OSLD) system, commercially known as the nanoDot™ dosemeter and the InLight® microStar reader, for personal and in vivo dose measurements in diagnostic radiology. The system characteristics, such as dose linearity, reade...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncz186

    authors: Wong JHD,Bakhsh M,Cheah YY,Jong WL,Khor JS,Ng KH

    更新日期:2019-12-31 00:00:00

  • DEVELOPMENT OF A NATIONAL EMERGENCY PLAN FOR MEDICAL DIAGNOSTICS AND THERAPY OF DETERMINISTIC EFFECTS AFTER RADIATION ACCIDENTS.

    abstract::The focus of nuclear emergency planning in Austria has been so far on mitigating effects of widespread contamination (e.g. after NPP accidents); however, these plans did not contain provisions on the medical management of an acute radiation syndrome. To close this gap, a 'Medical Radiation Emergency Plan' was created ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncw210

    authors: Ziegler A

    更新日期:2016-09-01 00:00:00

  • Assessment of radiation doses to Australian participants in British nuclear tests.

    abstract::Between 1952 and 1957, the UK exploded a total of 12 nuclear devices in Australia, and also conducted about 600 'minor trials' that did not involve a nuclear explosion. Over 16 000 Australian servicemen and civilians were involved in the UK tests in Australia. This paper reports the estimation of doses that the Austra...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncp164

    authors: Crouch P,Robotham FR,Williams G,Wise K

    更新日期:2009-09-01 00:00:00

  • Evaluation of solid state nuclear track detector stacks exposed on the international space station.

    abstract::The aim of the study was to investigate the contribution of secondary neutrons to the total dose inside the International Space Station (ISS). For this purpose solid-state nuclear track detector (SSNTD) stacks were used. Each stack consisted of three CR-39 sheets. The first and second sheets were separated by a Ti pla...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch140

    authors: Pálfalvi JK,Akatov Y,Szabó J,Sajó-Bohus L,Eördögh I

    更新日期:2004-01-01 00:00:00

  • Radiation protection issues for laser-based accelerators.

    abstract::Radiation particles, besides their application to fundamental research, are widely applied in all fields of science (medicine, material science, chemistry, etc.). Up to today the radiations were produced by radiation sources such as accelerators, X-ray tubes, radioactive sources with the well-known problems of costs, ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncr239

    authors: Esposito A

    更新日期:2011-07-01 00:00:00

  • Maximum likelihood estimates of mean and variance of occupation radiation doses subjected to minimum detection levels.

    abstract::Data collection and its analysis in the field of nuclear safety is an important task in the sense that it powers the improvement of safety as well as reliability of the plant. Thus, occupational exposure data analysis is presented to measure the safety or reliability of radiation protection of a given facility. It als...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm483

    authors: Datta D,Singh S,Johnson BE,Kushwaha HS

    更新日期:2008-01-01 00:00:00

  • Comparative analysis between radiation doses obtained by EPR dosimetry using tooth enamel and established analytical methods for the population of radioactively contaminated territories.

    abstract::A comparative analysis of radiation doses determined by tooth enamel electron paramagnetic resonance (EPR) spectroscopy and by an acknowledged analytical method is performed for individual doses and for average doses in population of some settlements of the Bryansk region (Russia), which have been contaminated after t...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncu132

    authors: Ivannikov AI,Skvortsov VG,Stepanenko VF,Zhumadilov KSh

    更新日期:2014-06-01 00:00:00

  • A TLD-based personal dosemeter system for aircrew monitoring.

    abstract::Evaluation of LiF:Mg,Ti thermoluminescence dosemeters (TLDs) according to the high-temperature ratio (HTR) method enables the determination of the dose-average linear energy transfer (LET), the mean quality factor and the dose equivalent in mixed radiation fields of unknown composition. The neutron contribution is ass...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch209

    authors: Hajek M,Berger T,Vana N

    更新日期:2004-01-01 00:00:00

  • The response of a bonner sphere spectrometer to charged hadrons.

    abstract::Bonner sphere spectrometers (BSSs) are employed in neutron spectrometry and dosimetry since many years. Recent developments have seen the addition to a conventional BSS of one or more detectors (moderator plus thermal neutron counter) specifically designed to improve the overall response of the spectrometer to neutron...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch187

    authors: Agosteo S,Dimovasili E,Fassò A,Silari M

    更新日期:2004-01-01 00:00:00

  • Assessment of radiographic screen-film systems: a comparison between the use of a microdensitometer and a drum film digitiser.

    abstract::A high-end drum film digitiser (Tango, Germany) and a calibrated linear microdensitometer developed by PTB were used to assess the modulation transfer function (MTF) and the noise power spectra (NPS) of 3 mammographic screen film systems at optical density levels of 0.8, 1.5 and 2.5. The use of a drum scanner to asses...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch563

    authors: Verdun FR,Pachoud M,Bergmann D,Buhr E

    更新日期:2005-01-01 00:00:00

  • Studies of patient doses in interventional radiological examinations.

    abstract::In Russia, especially in big cities like St. Petersburg, the annual number of interventional radiological (IR) examinations for both diagnostic and treatment purposes is increasing continuously. However, IR examinations might involve high patient doses and even the risk of skin injures that should be prevented. In thi...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章,多中心研究

    doi:10.1093/rpd/ncq021

    authors: Sarycheva S,Golikov V,Kalnicky S

    更新日期:2010-04-01 00:00:00

  • Non-targeted effects of radiation: bystander responses in cell and tissue models.

    abstract::The standard paradigm for radiation effects in cellular systems has involved direct damage to DNA and in particular, DNA double strand breaks as the triggering lesions leading to mutation, cell death and transformation. Recently, however, a growing body of evidence has reported non-targeted effects, which are not a di...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006768

    authors: Prise KM,Belyakov OV,Newman HC,Patel S,Schettino G,Folkard M,Michael BD

    更新日期:2002-01-01 00:00:00

  • Ethical issues in radiology: perspectives from the Christian tradition.

    abstract::The Christian ethical tradition introduces a number of key values into the clinical context. Moreover, although some denominational differences exist, these are essentially differences of emphasis rather than of substance. Among the central values which the Christian tradition promotes are: the dignity of the person, ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncp044

    authors: Hogan L

    更新日期:2009-07-01 00:00:00

  • Long-term measurements of radon equilibrium factor in Greek dwellings.

    abstract::The time variation of the radon equilibrium factor F was measured every four hours in the Nuclear Technology Laboratory of the Aristotle University of Thessaloniki (in northern Greece) during October 1998-April 1999. The time dependence of the mean weekly value of radon equilibrium factor F is relatively small. During...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006143

    authors: Clouvas A,Xanthos S,Antonopoulos-Domis M

    更新日期:2003-01-01 00:00:00

  • Experiences in methods to involve key players in planning protective actions in the case of a nuclear accident.

    abstract::A widely used method in the planning of protective actions is to establish a stakeholder network to generate a comprehensive set of generic protective actions. The aim is to increase competence and build links for communication and coordination. The approach of this work was to systematically evaluate protective actio...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch258

    authors: Sinkko K,Hämäläinen RP,Hänninen R

    更新日期:2004-01-01 00:00:00

  • Modelling the 137Cs ingestion dose from consumption of marine fish in Hong Kong.

    abstract::This paper presents a compartmental model for estimating the ingestion dose, due to 137Cs, arising from the consumption of marine fish in Hong Kong. 137Cs is one of the more important radionuclides released in routine liquid effluents discharged from the Guangdong Nuclear Power Station at Daya Bay, which began commerc...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006710

    authors: Poon CB,Au SM

    更新日期:2002-01-01 00:00:00

  • Natural radioactivity levels of geothermal waters and their influence on soil and agricultural activities.

    abstract::All over the world geothermal sources are used for different purposes. The contents of these waters are important to understand positive/negative effects on human life. In this study, natural radioactivity concentrations of geothermal waters were investigated to evaluate the effect on soils and agricultural activities...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nct220

    authors: Murat Saç M,Aydemir S,Içhedef M,Kumru MN,Bolca M,Ozen F

    更新日期:2014-01-01 00:00:00

  • OCCUPATIONAL DOSE DURING ADULT INTERVENTIONAL CARDIOLOGY: FIRST VALUES WITH PERSONAL ACTIVE DOSIMETERS IN CHILE.

    abstract::The objective of this article is to present initial occupational dose values using digital active personal dosimeters for medical staff during adult interventional cardiology procedures in a public hospital in Chile. Personal dose equivalent Hp(10) over the lead apron of physician, nurse and radiographer were measured...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncy057

    authors: Ubeda C,Morales C,Gutiérrez D,Oliveira M,Manterola C

    更新日期:2018-12-01 00:00:00

  • Validating a MCNPX model of Mg(Ar) and TE(TE) ionisation chambers exposed to 60CO gamma rays.

    abstract::For an accurate determination of the absorbed doses in complex radiation fields (e.g. mixed neutron-gamma fields), a better interpretation of the response of ionisation chambers is required. This study investigates a model of the ionisation chambers using a different approach, analysing the collected charge per minute...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm484

    authors: Roca A,Nievaart VA,Moss RL,Stecher-Rasmussen F,Zamfir NV

    更新日期:2008-01-01 00:00:00

  • Energy dependence of W values of protons in water.

    abstract::The W values of protons in water vapour were measured for energies from 1 keV to 100 keV with uncertainties lower than 1%. To study the energy and phase dependence of W values, the W values of protons in water vapour and liquid water were calculated for energies from 0.1 keV and 10 MeV and then compared to the experim...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006798

    authors: Willems G,Back WY,Grosswendt B

    更新日期:2002-01-01 00:00:00

  • EFFECTIVE INDOOR DOSE OF GAMMA RADIATION FROM BUILDING MATERIALS: COMPARISON OF SEVERAL METHODS FOR ESTIMATION AND POSSIBLE UNDERESTIMATE.

    abstract::This paper compares several methods for estimation of the effective indoor dose of gamma radiation from building materials. It was found that specific dose ratios proposed for 3 cm thick layers in one recommendation gives 2.8 times lower value of gamma dose than other methods. The most common case is that granite has ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncaa125

    authors: Krmar M,Milić K,Arsenić I,Hansman J

    更新日期:2020-10-16 00:00:00

  • Eu-doped CsBr phosphor as a new optically-stimulable phosphor material for medical X-ray imaging sensor.

    abstract::CsBr phosphor ceramics doped with different luminescence centres such as In2O3, Eu2O3, EuCl3, SmCl3, TbCl3, GdCl3 or NdCl3 as the candidate for a new optically-stimulable phosphor for medical X-ray imaging sensor were prepared using a conventional ceramic fabrication process. It was found that X-ray-irradiated Eu-dope...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci515

    authors: Kurata N,Kubota N,Takei Y,Nanto H

    更新日期:2006-01-01 00:00:00

  • Qualifying the use of RIS data for patient dose by comparison with DICOM header data.

    abstract::A system was developed in 2008 to calculate patient doses using Radiology Information System (RIS) data and presents these data as a patient dose audit. One of the issues with this system was the quality of user-entered data. It has been shown that Digital Imaging and Communication in Medicine (DICOM) header data can ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncr352

    authors: Wilde R,Charnock P,McDonald S,Moores BM

    更新日期:2011-09-01 00:00:00

  • DEVELOPMENT AND APPLICATION OF SOLID FORMS OF CaSO4:Dy THERMOLUMINESCENT DOSEMETERS IN RADIATION PROTECTION DOSIMETRY-A REVIEW.

    abstract::CaSO4:Dy is a reliable high-sensitive themoluminescent phosphor useful for low-level and high-level radiation measurements as it exhibits fading free linear dose response with a single glow peak at ~230°C in these dose regions. For large-scale radiation protection dosimetry service, it is embedded in Teflon matrix wit...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章,评审

    doi:10.1093/rpd/ncx287

    authors: Lakshmanan A

    更新日期:2018-10-01 00:00:00

  • Effective dose to a patient undergoing coronary angiography.

    abstract::Detailed data relating to patient dose have been acquired for 18, randomly chosen, patients undergoing coronary angiographies. During the procedure, dose-area product (DAP), kV and beam collimation were recorded for each projection. Total DAP, fluoroscopy time and number of cine frames were also noted. Patient effecti...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006466

    authors: Lobotessi H,Karoussou A,Neofotistou V,Louisi A,Tsapaki V

    更新日期:2001-01-01 00:00:00

  • Long-term monitoring of radiation exposure of employees in the department of nuclear medicine (Szczecin, Poland) in the years 1991-2007.

    abstract::Occupational radiation exposure is a hazard that should be avoided or at least minimised. This study aimed to evaluate the radiation exposure of nuclear medicine department employees monitored during the 1991-2007 period, and to investigate the relationship between the annual effective doses of the personnel and the n...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq117

    authors: Piwowarska-Bilska H,Birkenfeld B,Listewnik M,Zorga P

    更新日期:2010-08-01 00:00:00

  • Relative radiological risks derived from different TENORM wastes in Malaysia.

    abstract::In Malaysia technologically enhanced naturally occurring radioactive materials (TENORM) wastes are mainly the product of the oil and gas industry and mineral processing. Among these TENORM wastes are tin tailing, tin slag, gypsum and oil sludge. Mineral processing and oil and gas industries produce large volume of TEN...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq577

    authors: Ismail B,Teng IL,Muhammad Samudi Y

    更新日期:2011-11-01 00:00:00