CHARACTERISATION AND EVALUATION OF AL2O3:C-BASED OPTICALLY STIMULATED LUMINESCENT DOSEMETER SYSTEM FOR DIAGNOSTIC X-RAYS: PERSONAL AND IN VIVO DOSIMETRY.

Abstract:

:This study characterises and evaluates an Al2O3:C-based optically stimulated luminescent dosemeter (OSLD) system, commercially known as the nanoDot™ dosemeter and the InLight® microStar reader, for personal and in vivo dose measurements in diagnostic radiology. The system characteristics, such as dose linearity, reader accuracy, reproducibility, batch homogeneity, energy dependence and signal stability, were explored. The suitability of the nanoDot™ dosemeters was evaluated by measuring the depth dose curve, in vivo dose measurement and image perturbation. The nanoDot™ dosemeters were observed to produce a linear dose with ±2.8% coefficient variation. Significant batch inhomogeneity (8.3%) was observed. A slight energy dependence (±6.1%) was observed between 60 and 140 kVp. The InLight® microStar reader demonstrated good accuracy and a reproducibility of ±2%. The depth dose curve measured using nanoDot™ dosemeters showed slightly lower responses than Monte Carlo simulation results. The total uncertainty for a single dose measurement using this system was 11%, but it could be reduced to 9.2% when energy dependence correction was applied.

journal_name

Radiat Prot Dosimetry

authors

Wong JHD,Bakhsh M,Cheah YY,Jong WL,Khor JS,Ng KH

doi

10.1093/rpd/ncz186

subject

Has Abstract

pub_date

2019-12-31 00:00:00

pages

451-460

issue

4

eissn

0144-8420

issn

1742-3406

pii

5606697

journal_volume

187

pub_type

杂志文章
  • Sub-slab depressurisation systems used in the Czech Republic and verification of their efficiency.

    abstract::Design principles for sub-slab depressurisation systems recently used in the Czech Republic for remediating existing buildings are described. Results of an efficiency analysis performed on the basis of data from >60 single-family houses are presented. It was found out that the efficiency varies between 70 and 98 %, wh...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncu219

    authors: Jiránek M

    更新日期:2014-11-01 00:00:00

  • How to prepare head tissue-equivalent liquids for SAR calculations, dosimetry and hyperthermia researches at 900 and 1800 MHz GSM frequencies.

    abstract::The potential harmful effect of electromagnetic fields on human health is an important issue that has been widely discussed in the scientific community. The investigation of temperature rise in human body following exposure to electromagnetic fields has been found impractical in many aspects. Therefore, fabrication of...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncv351

    authors: Sorgucu U,Develi I,Ozen S

    更新日期:2016-03-01 00:00:00

  • Dosimetric monitoring in Ukraine--present status and path to the future.

    abstract::Despite wide use of nuclear energy and radiation sources in industry and medicine, there is no centralised dose accounting system in Ukraine; existing dosimetry services operate obsolete manual thermoluminescence dosemeter (TLD) readers and do not meet modern proficiency standards. Currently, dosimetric monitoring is ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncl128

    authors: Chumak V,Boguslavskaya A

    更新日期:2007-01-01 00:00:00

  • A NEWLY DEVELOPED PHANTOM FOR PHYSICAL QUALITY ASSURANCE OF DENTAL CONE-BEAM COMPUTED TOMOGRAPHY.

    abstract::Two phantoms for a performance evaluation of cone-beam computed tomography (CBCT) were developed and their efficiency was tested. The first phantom, for low-contrast resolution, consisted of an acrylic circular plate with three 0.5-1.0 mm diameter rods. These rods enable the user to visually evaluate the limit of obse...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncy116

    authors: Bamba J,Ishida H,Araki K

    更新日期:2019-05-01 00:00:00

  • Managing Internal Radiation Contamination Following an Emergency: Identification of Gaps and Priorities.

    abstract::Following a radiological or nuclear emergency, first responders and the public may become internally contaminated with radioactive materials, as demonstrated during the Goiânia, Chernobyl and Fukushima accidents. Timely monitoring of the affected populations for potential internal contamination, assessment of radiatio...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncw199

    authors: Li C,Ansari A,Etherington G,Jourdain JR,Kukhta B,Kurihara O,Lopez MA,Ménétrier F,Alves Dos Reis A,Solomon S,Zhang J,Carr Z

    更新日期:2016-09-01 00:00:00

  • The newsletter 'European Research in Radiological Sciences'.

    abstract::The newsletter 'European Research in Radiological Sciences' is jointly published by the European Late Effects Project Group and the European Radiation Dosimetry Group to disseminate information about research projects and activities carried out under the EURATOM Framework Programme. Since May 2003, the Newsletter is o...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch095

    authors: Pihet P,d'Errico F,Dörr W,Gruenberger M,Schofield P

    更新日期:2004-01-01 00:00:00

  • A biokinetic model for predicting the retention of 3H in the human body after intakes of tritiated water.

    abstract::Scarce published data on the long-term excretion of tritiated water from the human body have been re-evaluated in order to develop a biokinetic model describing the retention in the human body of 3H from tritiated water (HTO) that could be used for both prospective and retrospective radiation protection. A three-compo...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006227

    authors: Taylor DM

    更新日期:2003-01-01 00:00:00

  • Different versions of the right answer: the importance of measurement uncertainty in radiation dosimetry.

    abstract::The performance of radiation dosemeters that are issued by approved individual monitoring services generally meet international standards, with typical results within a few tens of per cent of the reference value. Experienced dosimetry practitioners will understand the uncertainties and treat monitoring results with d...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq298

    authors: Gilvin P,McWhan A

    更新日期:2011-03-01 00:00:00

  • ORGAN ABSORBED DOSE ESTIMATION REFLECTING SPECIFIC ORGAN MASSES WITH SIMPLE SCALING OF REFERENCE DOSES USING THE ORGAN MASSES.

    abstract::Estimating organ absorbed doses in consideration of person-specific parameters is important for radiation protection in diagnostic nuclear medicine. This study proposes a straightforward method for estimating the organ dose that reflects a specific organ mass by scaling the reference organ dose using the inverse ratio...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncaa058

    authors: Manabe K,Koyama S

    更新日期:2020-07-24 00:00:00

  • VISUALIZATION OF THE DNA REPAIR PROCESS IN MAMMALIAN CELLS TRANSFECTED WITH EGFP-EXPRESSING PLASMID DNA AFTER EXPOSURE TO X-RAYS IN VITRO.

    abstract::To investigate the repair process of DNA damage induced by ionizing radiation in isolation from various types of cytoplasmic damage, we transfected X-irradiated enhanced green fluorescent protein (EGFP)-expressing plasmid DNA into non-irradiated mammalian cells using lipofectamine. The repair kinetics of the irradiate...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncy241

    authors: Nakaue H,Obata Y,Kaminaga K,Akimitsu N,Yokoya A

    更新日期:2019-05-01 00:00:00

  • Radiation protection at low energy proton accelerators.

    abstract::A sample is provided of the radiological safety issues particular to low energy proton accelerators. 'Low' energy in this context is taken to mean proton energies of less than about 1 GeV. Many of the radiation issues are common to all particle accelerators. Here, those issues are addressed that may require perhaps no...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章,评审

    doi:10.1093/oxfordjournals.rpd.a006619

    authors: Moritz LE

    更新日期:2001-01-01 00:00:00

  • Assessment of occupational exposure to uranium by indirect methods needs information on natural background variations.

    abstract::Urine monitoring is the preferred method to determine exposure to soluble compounds of uranium in workplaces. The interpretation of uranium contents in workers bioassay samples requires knowledge on uranium excretion and its dependence on intake by diet. Exceptionally high concentrations of natural uranium in private ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm155

    authors: Muikku M,Heikkinen T,Puhakainen M,Rahola T,Salonen L

    更新日期:2007-01-01 00:00:00

  • Occupational radiation protection of health workers in imaging.

    abstract::Occupational radiological protection (RP) is still a challenge in several clinical practices. ICRP has included specific recommendations and advice for occupational protection in most of the documents published in recent years and its current programme of work includes the preparation of documents with specific conten...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncu354

    authors: Vano E

    更新日期:2015-04-01 00:00:00

  • Gamma-ray rejection, or detection, with gadolinium as a converter.

    abstract::Gadolinium is a competent neutron conversion material for neutron detection due to its extremely high neutron capture cross section. It differs from the other neutron reactive materials by emitting large amounts of low-energy electrons for the consequent signal generation in a detector. Such low-energy electrons, thou...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncs031

    authors: Kandlakunta P,Cao L

    更新日期:2012-09-01 00:00:00

  • UNATTACHED 212PB FRACTION IN THE WORKER'S BREATHING ZONE AT HIGH THORON CONCENTRATIONS.

    abstract::Classical aerosol physics predicts that it is impossible to observe noticeable values of the unattached fraction of decay products of thoron at typical concentrations of aerosol particles. The experimental data have shown that the unattached fraction of the thoron decay products in a monazite storage facility is in th...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncaa154

    authors: Zhukovsky M,Vasyanovich M,Onishchenko A

    更新日期:2020-11-27 00:00:00

  • DESIGN DEVELOPMENT OF A PASSIVE NEUTRON DOSEMETER FOR THE USE AT HIGH-ENERGY ACCELERATORS.

    abstract::For the radiation survey at intermediate and high-energy accelerators, there is a need for a neutron dosemeter which provides reliable readings of the neutron dose in a wide energy range for continuous and pulsed radiation. The objective of this development is to find a dosemeter that fulfils the necessary requirement...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncv489

    authors: Sokolov A,Fehrenbacher G,Radon T

    更新日期:2016-09-01 00:00:00

  • Parallel FD-TD simulation of radiobase antennae.

    abstract::The rigorous characterisation of the behaviour of a radiobase antenna for wireless communication systems is a hot topic both for antenna or communication system design and for radioprotection-hazard reasons. Such a characterisation deserves a numerical solution, and the use of a finite-difference time-domain (FD-TD) a...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006699

    authors: Catarinucci L,Palazzari P,Tarricone L

    更新日期:2001-01-01 00:00:00

  • THE IMPACT OF CIRCADIAN RHYTHMS ON MEDICAL IMAGING AND RADIOTHERAPY REGIMES FOR THE PAEDIATRIC PATIENT.

    abstract::Daily rhythmic changes are found in cellular events in cell cycle, DNA repair, apoptosis and angiogenesis in both normal and tumour tissue, as well as in enzymatic activity and drug metabolism. In this paper, we hypothesize that circadian rhythms need to be considered in radiation protection and optimization in person...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncw328

    authors: Forssell-Aronsson E,Quinlan RA

    更新日期:2017-04-01 00:00:00

  • PRACTICAL METHODS FOR INTERNAL DOSE ASSESSMENT FOR RADIOIODINE INTAKE AFTER THYROID BLOCKING: CLASSIFICATION OF DEGREE OF BLOCKAGE AND DETERMINATION OF INSENSITIVE MEASUREMENT POINT.

    abstract::Iodine thyroid blocking (ITB) suppresses the uptake of iodine to the thyroid and reduces internal doses after radioiodine intake; however, its disturbance of thyroid biokinetics causes considerable uncertainty in the use of dosimetric data intended for assessment of unblocked normal thyroid. To more accurately assess ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncz139

    authors: Kwon TE,Park M,Jung GH,Chung Y,Ha WH,Jin YW

    更新日期:2019-12-31 00:00:00

  • Assessment of the Absorbed Dose in the Kidney of Nuclear Nephrology Paediatric Patients using ICRP Biokinetic Data and Monte Carlo Simulations with Mass-Scaled Paediatric Voxel Phantoms.

    abstract::The aim of this work is to use Monte Carlo simulations and VOXEL phantoms to estimate the absorbed dose in paediatric patients (aged from 2 weeks to 16 y), with normal renal function, to whom technetium-99m-dimercaptosuccinic acid (99mTc-DMSA) was administered, for diagnostic renal scintigraphy purposes; and compare t...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncw096

    authors: Teles P,Mendes M,Zankl M,de Sousa V,Santos AI,Vaz P

    更新日期:2017-04-20 00:00:00

  • Seasonal variation of indoor radon-222 levels in dwellings in Ramallah province and East Jerusalem suburbs, Palestine.

    abstract::This study presents the seasonal variations of indoor radon levels in dwellings located in the Ramallah province and East Jerusalem suburbs, Palestine. The measurements were performed during the summer and winter of the year 2006/2007 using CR-39 solid-state-nuclear-track detectors. The total number of investigated bu...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncr013

    authors: Leghrouz AA,Abu-Samreh MM,Shehadeh AK

    更新日期:2012-01-01 00:00:00

  • Assessments of medical exposures during interventional radiology procedures.

    abstract::This study aims to contribute to the construction of a scenario regarding patient radiation exposure in Brazilian interventional radiology, aiming to provide data for the future drafting of specific legislation on interventional radiology because there is currently a lack of safety regulations for haemodynamics servic...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncs172

    authors: Navarro VC,Navarro MV,Maia AF

    更新日期:2013-04-01 00:00:00

  • SIMULATION OF OSL AND TLD DOSEMETER RESPONSE FOR THE DEVELOPMENT OF NEW EXTREMITY DOSEMETERS.

    abstract::The individual monitoring service at the Helmholtz Zentrum München is currently developing a new eye lens dosemeter to be integrated in radiation protection glasses and a new ring dosemeter using a new BeOSL detector element for extremity dosimetry developed by Dosimetrics. In the design process for the new eye lens d...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncy299

    authors: Hoedlmoser H,Brönner J,Bandalo V,Wahl F,Greiter MB

    更新日期:2019-12-23 00:00:00

  • Radiation exposure and disease questionnaires of early entrants after the Hiroshima bombing.

    abstract::It is popularly known that people who entered into the ground-zero area shortly after the atomic bombings in Hiroshima and Nagasaki suffered from various syndromes similar to acute radiation effects. External exposures from neutron-induced radionuclides in soil have recently been reassessed based on DS02 calculations ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncr370

    authors: Imanaka T,Endo S,Kawano N,Tanaka K

    更新日期:2012-03-01 00:00:00

  • 226Ra AND 228Ra CONCENTRATIONS IN SOILS WITH INTENSE GROUNDWATER IRRIGATION IN AN ARID ENVIRONMENT.

    abstract::The enhancing effect due to long-time irrigation with radium-containing groundwater on soil was investigated in this work. Samples from the Al-Qassim and Hail areas in Saudi Arabia were studied for their 226Ra and 228Ra inventories. Groundwater and soil samples were collected from 32 farms where agricultural activitie...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncz287

    authors: Ebaid YY

    更新日期:2020-06-24 00:00:00

  • Dental CBCT equipment and performance issues.

    abstract::Dental cone beam computed tomography (CBCT), also known as digital volumetric tomography was developed in the late 1990s and is now increasingly available in clinical practice. It can provide high resolution cross-sectional images of teeth and the maxillofacial region with applications in all branches of dentistry. As...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章,评审

    doi:10.1093/rpd/ncs289

    authors: Horner K,Jacobs R,Schulze R

    更新日期:2013-02-01 00:00:00

  • In vivo thyroid 131I monitoring system using an imaging plate.

    abstract::The counting efficiency and detection limit of an in vivo thyroid 131I monitoring system using an imaging plate (IP) were estimated using an anthropomorphic thyroid neck phantom. The counting efficiency of the IP system was approximately constant for thyroid volumes between 11.7 and 20 ml and neck diameters between 10...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006025

    authors: Hirota M,Saze T,Nishizawa K

    更新日期:2002-01-01 00:00:00

  • Risk management policies and practices regarding radio frequency electromagnetic fields: results from a WHO survey.

    abstract::This study aims to describe current risk management practices and policies across the world in relation to personal exposures from devices emitting radiofrequency fields, environmental exposures from fixed installations and exposures in the work environment. Data from 86 countries representing all WHO regions were col...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncu324

    authors: Dhungel A,Zmirou-Navier D,van Deventer E

    更新日期:2015-04-01 00:00:00

  • Hardness ratios of different neutron spectra.

    abstract::Extensive data have been gathered in the past on the response of different detectors, based on the registration of neutron-induced fissions in bismuth, gold, tantalum and thorium by the spark-replica counter and the thin film breakdown counter. These detectors make it possible to exploit the excellent characteristics ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch168

    authors: Tommasino L,Tripathy SP

    更新日期:2004-01-01 00:00:00

  • CONCEPTS OF OPERATIONS FOR A US DOSIMETRY AND BIODOSIMETRY NETWORK.

    abstract::The USA must be prepared to provide a prompt, coordinated and integrated response for radiation dose and injury assessment for suspected radiation exposure, whether it involves isolated cases or mass casualties. Dose estimation for radiation accidents typically necessitates a multiple parameter diagnostics approach th...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncy294

    authors: Dainiak N,Albanese J,Kaushik M,Balajee AS,Romanyukha A,Sharp TJ,Blakely WF

    更新日期:2019-12-31 00:00:00